CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Similar documents
CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Protection and Control of Solid Fuel Boilers

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Manual and installation instructions. Function. Operating phase

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Solar heating systems

STORAGE WATER HEATERS

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

sustainable energy solutions

Technical Product Guide

Trade Product List 2013 BIOMASS ACCESSORIES

Control valves for floor heating systems. Floor Heating Manifolds

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

ModuSat TP. Energy. Heat Interface Units

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

Systems for central heating

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Wood Boiler Plumbing Schematics

The Meibes concept for the specialist: Easier. Quicker. More successful.

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

Roth fixed-value control set with high-efficiency pump

Description of functions

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

HERZ Differential Pressure Control Valve 4002

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Installation and instruction manual SOLAR STATION

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

General System Layout Sketch

Spare parts list. Hydraulic compactor RC

BOILER COMPLETE FORCED CIRCULATION SYSTEMS. solair. Inspired by the sun. Save your energy.

ecocirc E1 Domestic hot water / Sanitary pumps Unequalled economically! Only 8 Watt!

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Thermostatic valve bodies

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

Components for solar heating systems

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

WOOD CHIP/PELLETS HEATING SYSTEMS

HERZ Regulating valve 4002

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Metering systems 0548EN April 2014

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Pressure washers K 2 Basic

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Laddomat. Mixing valves for solid fuel boilers. Version 1.01

ultracirc Domestic hot water / Sanitary pumps Instant hot water at every faucet More comfort Saves water and energy

product overview ProControl

Standard. thermostatic valve body without presetting

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

K K 2.120, ,

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Smart temperature control solutions

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

MANUAL. Page 1/44

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Products K 2 Home. Technical data

FHM-Cx Mixing Shunts for Floor Heating

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GASTEC QA. Approval Requirements 69-1

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Mikrotherm. Manual Radiator Valves With presetting

MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

Domestic Hot Water Tank

Wet and dry vacuum cleaners NT 25/1 Ap

K 2 K 2, ,

manifold, for radiators

K 2 Car. K 2 Car, ,

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION HYDRONIC PIPING

Powerstock Storage Tank

FHM-Cx Mixing Shunts for Floor Heating

Flow Switches. Series VHS, VKS, VH

PARTS MANUAL Rev 1.00B DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

RA 2000 Series RA 15/6T & TB Conversion Valve

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

FSW300 Series Flow Switch

K 2 Premium Car & Home

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

floor convectors PRACTIC floor convectors

Thermotech underfloor heating

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

Transcription:

Instruction Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN v 1.1

CONTENTS: 1 Introduction 3 2 Connection dimensions of CS TSV MIX Regulus 3 3 Function description of CS TSV MIX Regulus 6 4 Schematic hydraulic diagram of CS TSV MIX Regulus 6 5 Variants of CS TSV MIX Regulus 6 6 Components of CS TSV MIX Regulus 6 7 Function description of the TSV3B valve 7 8 Description of the 3-way mixing valve 7 9 G 6/4 Pumps 7 10 M21 actuator for mixing valve 8 11 Optional accessories 8-2 -

1 Introduction CS TSV MIX Regulus Pump Station makes boiler installation easier. It contains all the important components necessary for boiler protection and proper operation in both space- and water heating. It is designed to be mounted directly on a boiler fl ow piping or on a wall. This pump station is designed for solid-fuel boilers with an accumulation tank, enabling sanitary water heating in a storage tank. 2 Connection dimensions of CS TSV MIX Regulus inner thread inner thread outer thread outer thread - 3 -

Components of CS TSV MIX Regulus Pump Station with codes: 12675 [12678, 12676, 13178, 11605, 7700, 11606, 8118, 12210, 12207, 12211, 12208] or or with actuator - 4 -

or Code Item name Qty Unit 7049 T-piece, brass, 1 FFF 3 pcs 8197 T-piece, brass, reducer, 1 x 3/4 FFF 1 pcs 7092 Ball valve, 1,M-F 2 pcs 5597 Coupling for pump, 6/4-1 F-F, brass, incl. gaskets 3 pcs 7691 Hex head plug, brass, 1 M 2 pcs either 12355 TSV3B thermostatic valve with nut, G6/4, 55 C, DN 25 G1 F 1 pcs or 12356 TSV3B thermostatic valve with nut, G6/4, 65 C, DN 25 G1 F 1 pcs 7048 Nipple, 1, brass 5 pcs buď 10630 3-way mixing valve, 1 F 1 pcs or with 10630 9193 230V actuator for mixing valve, 120s, 5Nm, three point on/off 1 pcs 6969 Nipple, 1, thick wall 2 pcs 8198 Male pipe adapter, 1 to Cu 22, brazing 3 pcs 12212 Male pipe adapter, 3/4 to Cu 22, brazing 1 pcs 7105 Copper pipe, 22x1, semi-hard, 5m 0,2 m 9710 Gasket for pump union nut, 6/4 4 pcs 10989 5-layer cardboard fl ap box, 840x300x150, 300x830 division 1 pcs either 12128 Yonos Para 25/1-6 RKC circ. pump, 180mm, 6/4 2 pcs or 12402 ALPHA2 L 25-60 180 circ. pump, 1x230V, class A 2 pcs or 7859 ST 25/7-180-9h-6/4 circ. pump 2 pcs - 5 -

3 Function description of CS TSV MIX Regulus CS TSV MIX keeps the return temperature to a boiler at 55 C [65 C] which prevents condensation and boiler tarring. Water for the heating system (i.e. power for the heating system) is mixed in a 3-way valve, either a manually operated one, or an electronically controlled valve. Heat surplus is stored in the accumulation tank and used automatically when the boiler extinguishes. 4 Schematic hydraulic diagram of CS TSV MIX Regulus TS 1 BOILER STORAGE WATER HEATER ACCUM. TANK 2 3 Key: TS - heating system TV - domestic hot water SV - cold water E - expansion vessel B - manometer ZV- - zone valve, normally open NO 1 Safety assembly for a heating system, code 9797. The assembly contains a manometer, air release valve and a safety valve. In case these components are already installed on the boiler, this assembly is not needed. 2 A storage water heater can be connected to the pump station. 3 An accumulation tank can be connected to the pump station. Optional accessories 5 Variants of CS TSV MIX Regulus Model TSV temper. Pump Mix. valve actuator Code CS TSV MIX 55 YP 26/1-6 55 C Yonos Para 25/1-6 RKC No 12675 CS TSV MIX 65 YP 26/1-6 65 C Yonos Para 25/1-6 RKC No 12678 CS TSV MIX 55 P YP 26/1-6 55 C Yonos Para 25/1-6 RKC Yes 12676 CS TSV MIX 65 P YP 26/1-6 65 C Yonos Para 25/1-6 RKC Yes 13178 CS TSV MIX 55 ST 25/7 55 C Star ST 25/7 No 11605 CS TSV MIX 65 ST 25/7 65 C Star ST 25/7 No 7700 CS TSV MIX 55 P ST 25/7 55 C Star ST 25/7 Yes 11606 CS TSV MIX 65 P ST 25/7 65 C Star ST 25/7 Yes 8118 CS TSV MIX 55 Alpha 55 C Alpha2 L 25-60 No 12210 CS TSV MIX 65 Alpha 65 C Alpha2 L 25-60 No 12207 CS TSV MIX 55 P Alpha 55 C Alpha2 L 25-60 Yes 12211 CS TSV MIX 65 P Alpha 65 C Alpha2 L 25-60 Yes 12208-6 -

6 Components of CS TSV MIX Regulus» heating system pumps» TSV3B thermostatic mixing valve» 2 ball valves for connection to a heating system» 3-way mixing valve for a heating system» mixing valve actuator (for the version with actuator only) 7 Function description of the TSV3B valve [12355-55 C or 12356-65 C] TSV B thermostatic mixing valve is fitted with an integrated thermostatic element that will close the A inlet (from a heating system), if the return water to the boiler ( AB outlet) is colder than nominal. As soon as the nominal temperature is reached, the thermostat starts opening the A inlet slowly and mixing the cold return water with the hot water from the B inlet (boiler outlet) with the aim to reach the nominal return temperature ( AB outlet). At the same time, it closes the B inlet, limiting so the hot water fl ow coming from the by-pass till its complete tight closure. Thanks to this, no balancing valve is needed. The Thermostatic mixing valve is made of brass, sealing of the element and body plug are made of EPDM, sealing of closing plug is made of NBR. 8 Description of the 3-way mixing valve A 3-way mixing valve mixes heating water for a heating system to a required temperature. Mixing is done by a circular segment rotor. The rotor turning angle used for regulation is about 90 and corresponds to a scale from 0 to 10 (without stops it can rotate 360 ). 9 G 6/4 Pumps: Wilo Star ST 25/7-180mm, G6/4 [7859] Wilo Yonos Para 25/1-6 RKC, 180mm, G6/4 [12128] Grundfos ALPHA2L 25-40, 180mm, G6/4 [12402] Design Wet running circulation pumps with threaded joints. Selectable speed steps for output adjustment. Application All hot-water heating systems, industrial circulation systems, cold water circulation systems and A/C units. - 7 -

Wilo Star ST 25/7-180mm, G 6/4, code 7859 Wilo Yonos Para 25/1-6 RKC, 180mm, G 6/4, code 12128 Grundfos ALPHA2L 25-60, 180mm, G 6/4, code 12402 10 M21 actuator for mixing valve [code 9193] Technical data: Power supply - 230V/ 50Hz Torque - 5Nm Shift time - 120s El. protection - IP42 11 Optional accessories a) Safety assembly for a heating system [code 9797] The assembly contains a manometer, air release valve and a safety valve. In case these components are already installed on the boiler, this assembly is not needed. b) Regulus storage water heaters - model lines RBC, R2BC, RGC, R2GC, NBC, N2BC, RDC and R2DC c) Accumulation tanks - model lines PS, PS E, PSWF, PS2F, PS N, PSWF N, PS2F N, HSK, DUO E and DUO E2. 09/2014 REGULUS spol. s r.o. Do Koutů 1897/3 http://www.regulus.eu 143 00 Praha 4 E-mail: sales@regulus.cz CZECH REPUBLIC