TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Similar documents
TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

GridScan/Mini. Installation and Operation Manual. English Pages 1 14 Deutsch Seiten Français Pages Español Páginas 41 53

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

OPTISENS TUR 2000 Technical Datasheet

Laser Collimated Beam Sensor

Laser Distance Sensor Type M Analog-Output

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Phone: Fax: Web:

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

General Purpose Photoelectric Sensor

ILLUMINATORS SIL SERIES INDUSTRIAL ILLUMINATORS

2 General Application Photoelectric Sensors

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

R2310. Infrared Thermometer. Instruction Manual

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Square D Clipsal Outdoor Light-Level Sensor

O P Style Meter with Optical Sensor Switch

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Commercial Series TriTech Motion Detector. Reference Guide

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

The Affordable, All-Purpose Sensor That's EZ To Use!

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

RSMFM-2R MULTIFUNCTIONAL

Automatic Self-Adjusting General Purpose Sensor

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Increased safety and reducing energy consumption with the motion control RPI 01

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

SENSOR SOLUTIONS FOR DOORS

onlinecomponents.com

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Retro-reflective Sensing range: 0mm to 2000mm

LED Flood 50W LED floodlight. user manual

OWNERS MANUAL OPERATION GUIDE

GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

North Dakota State University Laser Safety

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Operating Manual MS220DA

UNIVERSAL COMPACT SENSORS

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

INSTRUCTION MANUAL. Handy Controller Exclusive for SF4B / SF4B<V2> Series. SFB-HC Ver.2.1 FUNCTION CANCEL ENTER

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

FIRERAY 5000 range USER GUIDE

Applications PL- N Series Lens Type Sensor Type Serial Number

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Retroreflective sensor with polarization filter

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Important Safety Notice

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

2 Specialty Application Photoelectric Sensors

SENSOR SOLUTIONS FOR DOORS

DMFPM-2R MULTIFUNCTIONAL

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

CEILING SPEAKER SYSTEM

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Snifter ATEX22 VERSION. User Manual. Distributor

Manual. Belt Sander BSL 115/E. ProxxonTools.com

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Safety, Installation, and Operation Manual

SYNRAD Laser Safety 101

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

DT1101A / DT1102A / DO110xA Automatic fire detectors

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

Open-area Smoke Imaging Detection (OSID)

A-MIP 100 Installation and Operating Manual

RE-PR3-E-27 3-Phase Panel Mount 27kW

Quadrature Speed and Direction Sensors

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Doors & Gates sensors Product overview

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Dual Laser InfraRed (IR) Thermometer

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

SPACEMOTION SERIES SMM 01

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Transcription:

Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 200808 English Pages 2-12 110 605 130208 V 1.1

Contents 1. About this manual 2 1.1 Measurements 2 1.2 Related documents 2 1.3 CEDES headquarters 2 2. Safety information 3 2.1 Non-intended use 3 3. Symbols, safety messages 3 3.1 Safety message categories 3 4. Introduction 4 4.1 Application examples 4 4.2 Features of the TLS 500 4 4.3 Type description 4 5. Overview 5 5.1 Delivery package 5 5.2 TLS 500 product overview 6 5.3 Detection area dimensions 6 6. Configuration 6 6.1 N-type 6 6.2 P-type 6 6.3 VR-type 7 6.4 Correction factor 7 7. Installation 7 8. Electrical connection 8 8.1 Semiconductor output 8 8.2 Test input 8 9. Timing diagram 9 10. Start-up 9 10.1 Test run 9 11. LED signals 10 12. Troubleshooting 10 13. Maintenance 10 14. Disposal 10 15. Technical data 11 16. Dimensions 12 16.1 Mounting bracket dimensions 12 1. About this manual This 'TLS 500 Installation and Operation Manual', with metric and US measurements is the original version. The version number is printed at the bottom of each page. To make sure you have the latest version, visit www.cedes.com from where this manual and related documents can be downloaded. 1.1 Measurements Unless stated otherwise, measurements are given in mm (non-bracketed numbers) and inches (numbers in brackets). 1.2 Related documents TLS 500 datasheet en Part No. 001 181 en TLS 500 Quickguide en de fr it es pl zh Part No. 112 015 1.3 CEDES headquarters CEDES AG Science Park CH-7302 Landquart Switzerland 2 CEDES AG reserves the right to modify or change technical data without prior notice. CEDES V 1.1

English 2. Safety information IMPORTANT! READ BEFORE INSTALLATION! The TLS 500 was developed and manufactured using state-of-the-art systems and technologies. However, injury and damage to the sensor can still occur. To ensure safe operating conditions: Read all enclosed instructions and information. Follow the instructions given in this manual carefully. Observe all warnings included in the documentation and attached to the sensor. Do not use the sensor if it is damaged in any way. Keep the instruction manual on site. The TLS 500 should only be installed by authorized and fully trained personnel! The installer or system integrator is fully responsible for the safe integration of the sensor. It is the sole responsibility of the planner and/or installer and/or buyer to ensure that this product is used according to all applicable standards, laws and regulations in order to ensure safe operation of the whole application. Any alterations to the device by the buyer, installer or user may result in unsafe operating conditions. CEDES is not responsible for any liability or warranty claim that results from such manipulation. Failure to follow instructions given in this manual and/or other documents related to the TLS 500 may cause customer complaints, serious call backs, damage, injury or death. 2.1 Non-intended use The TLS 500 must not be used for: The safeguarding of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications, otherwise serious injury or death or damage to property may occur! 3. Symbols, safety messages Symbol Meaning Single instruction or measures in no specific order 1. Instructions in specific order 2. 3. List, in no order of importance Reference to a chapter, illustration or table within this document Important: Important information for the correct use of the sensor 3.1 Safety message categories Warning of serious health risks Warning Serious health risks Highlights critical information for the safe use of the sensor. Disregarding these warnings can result in serious injury or death. Follow the measures highlighted by the triangle-shaped arrows Consult the safety information in Chapter 2 of this manual Caution of possible health risks Caution Possible health risks Highlights critical information for the safe use of the sensor. Disregarding these warnings can result in injury. Follow the measures highlighted by the triangle-shaped arrows Consult the safety information in Chapter 2 of this manual Notice of damage risk Notice Risk of damage Disregarding these notices can lead to damage to the sensor, the controller and/or other devices. Follow the measures highlighted by the triangle-shaped arrows CEDES V 1.1 3

4. Introduction CEDES' ultra-compact TLS 500, which is only half the size of a matchbox, monitors the approach areas to automatic doors and escalators, detecting intending users and ensuring comfortable and safe operation. It can also be used to safeguard the dangerous area between sections of folding doors often found on public transportation. Its elegant design allows it to blend in perfectly with any application s surroundings. This, alongside its easy mounting and alignment, make it the ideal door sensor for the widest variety of automatic doors. Its incredible reliability, combined with robust construction, adjustable range and optional automatic blanking of stationary objects, means the TLS 500 offers a very impressive price/performance ratio. 4.1 Application examples Approach to escalators Door opener Touchless switch Safeguarding of automatic door edges 4.2 Features of the TLS 500 Measures just 32 22 27.5 mm (1.26 0.87 1.08 in) Electronics housed in an elegant matt-black unit Easy mounting and alignment Plug-and-play thanks to intelligent software Discreet green/red LEDs indicate the sensor's status Range from 0.2 m to 6 m (0.65... 19.7 ft) Insensitive to ambient light up to 100 000 Lux 4.3 Type description TLS 500 x xxx xx Output logic LO Light on DO Dark on Output type PNP NPN Sensor type N Standard P Adjustable recalibration time VR Adjustable range Figure 2: TLS 500 type description Figure 1: A typical TLS 500 application environment 4 CEDES V 1.1

English 5. Overview The TLS 500 measures the reflection from objects compared with background reflection. Any change in the values is detected as an object and the output switches. During startup the TLS 500 takes a background light measurement and saves this as a reference value. When an object enters the detection area, the reflection value changes. The bigger the difference in light reflection between the object and the background, the easier it is to detect said object. High contrast between objects and background results in high sensitivity. CAuTION Damage to the eye Although the TLS 500 does not emit dangerous amounts of infrared light, long exposure to intense infrared light sources can result in damage to the eyes. To avoid any risks: Never look directly into the active infrared emitter from a close distance. Figure 3: Two TLS 500-VRs monitoring an escalator approach Figure 4: TLS 500-N monitoring an automatic sliding door 5.1 Delivery package Each delivery package contains: 1 TLS 500 sensor 1 mounting bracket 2 mounting screws 1 blue screwdriver 1 quick installation guide Figure 5: TLS 500 components CEDES V 1.1 5

5.2 TLS 500 product overview 1 6. Configuration Notice Mechanical damage to the TLS 500 Do not turn the potentiometers beyond their mechanical limits 3 2 Figure 6: TLS 500 overview 1 Mounting bracket 2 Optical window 3 Toothing for sensor alignment 4 Connection cable 5 Potentiometer 5 4 1. The potentiometer on the back of the TLS 500 is covered by a flap Chapter 5.2. Lift the rubber flap at the back of the TLS 500 carefully with the slotted side of the blue screw driver provided. 2. Using the screw driver, turn the potentiometer to either fully left or fully right. 3. Set the potentiometer to the correct value according to the application Figure 8 (P-type) or Figure 9 (VR-type) 4. Put the flap back over the cover 6.1 N-type 5.3 Detection area dimensions The detection area dimensions of the sensor depend on application, installation, mounting heights and settings. All measurements in mm (normal numbers) and inches (in brackets) TLS 500 sensor The N-type needs no configuration; the recalibration time is fixed at 10 s. Recalibration time means the time until an immobile person or object is accepted by the sensor as background. 6.2 P-type With the P-type, the recalibration time can be adjusted from 3 s up to 180 s. Recalibration time means the time until an immobile person or object is accepted by the sensor as background. 7 3 s 10 s l = 2000 (78.75) detection area 180 s 60 s 30 s Figure 8: Configuring the TLS 500 P-type (in seconds) 240 (9.4) Figure 7: Detection area dimensions 6 CEDES V 1.1

English 6.3 VR-type With the VR-type, the operation range (in m and inches) can be adjusted. 0.2 m (8 in) 1.5 m (4 ft 11 in) 3.0 m (9 ft 10 in) 4.5 m (14 ft 9 in) 6.0 m (19 ft 8 in) Figure 9: Configuring the TLS 500 VR-type (in m and in) 6.4 Correction factor Due to different background reflections, a correction factor has to be taken into account for setting the sensing distance. Reference material Correction factor f Kodak white 1.0 Kodak grey 0.6 Bright concrete 0.6... 0.8 Dry gravel 0.4... 0.5 Dark carpet 0.3... 0.5 Grey plastic fl oor (PVC etc.) 0.4... 0.8 Bright wood, brown cardboard 0.7... 0.8 Glass, metal plate 90 1.2... 2.0 Black fl oor, asphalt 0.4... 0.5 Cotton white 0.5... 0.7 Dull black card board 0.1... 0.3 Applies only when beam axis is perpendicular to surface Example: TLS 500-VR on a wooden floor Mounting height 3 m Correction factor 0.7... 0.8 Range setting 3 m / 0.7 0.8 = 3.75... 4.3 m 7. Installation WARNINg Electrical and mechanical hazards Electrical shock and unexpected mechanical movement can cause serious injury or death. Before installing and configuring the TLS 500 make sure the controller and all relevant devices are powered off Use only specifi c and approved tools Follow all applicable safety measures Do not over-tighten the mounting screws Do not drill additional holes into the TLS 500 If the TLS 500 must be readjusted, the main power supply must be switched off and marked as out of service Carry out the system installation according to the following steps: 1. Switch off main power for the installation area and mark it clearly with OUT OF SERVICE. 2. Fix the mounting bracket onto to the chosen location using the mounting screws. 16 mm (0.63 in) 8 mm (0.31 in) Ø 4 mm (0.16 in) Ø 3 mm Ø 3mm (0.12 in) Figure 10: (0.12 in) Mounting bracket fixing 3. Open the potentiometer flap on the back of the TLS 500. Figure 11: Opening the TLS 500 potentiometer flap CEDES V 1.1 7

4. Snap the TLS 500 into the mounting bracket. 6. Close the potentiometer flap. Figure 12: Snapping on the TLS 500 mounting bracket Figure 14: Closing the TLS 500 potentiometer flap 5. Adjust potentiometer and sensor alignment (VR- and P-types only) Chapter 6. 7. Connect the other end of the cable (open wires) to the controller. For detailed controller wiring Chapter 8. 8. Verify your settings by switching on the power and performing a test run Chapter 10.1. Figure 13: Potentiometer adjustment and alignment 8. Electrical connection TLS 500 USP (10... 30 VDC) brown Controller GND (0 VDC) blue Output black P-type + N-Type: Test signal white Figure 15: TLS 500 connection diagram 8.1 Semiconductor output The TLS 500 is available as a PNP or NPN version with either a dark-on (DO) or light-on (LO) type. The DO output is ON when an object or person is detected, OFF if the detection area is free. The LO output is OFF when an object or person is detected, ON if the detection area is free Chapter 9. Notice Possible damage to the semiconductor output PNP outputs need a pull-down resistor (10... 47 kω) NPN outputs need a pull-up resistor (10... 47 kω) 8.2 Test input TLS 500 performs a test cycle as follows: The illumination is switched off and the sensor recognizes the change and switches the output. Important: Please be aware that this works only with the N- and P-type when they see the floor. The test input cannot be used with the VR-type and has to be connected to USP. 8 CEDES V 1.1

English 9. Timing diagram Power supply Object detection Test input HIGH LOW Object No object HIGH LOW Test active Output PNP-LO / NPN-DO Output PNP-DO / NPN-LO HIGH LOW HIGH LOW t 1 t 2 t 3 t 5 t 4 Figure 16: TLS 500 timing diagram Time Value Power-up time t 1 < 150 ms Response time t 2 < 150 ms Release time t 3 < 150 ms Response time test input t 4 < 150 ms Value Output HIGH USP - 4 V Output LOW < 4 V Table 2: TLS 500 value table Time at test t 5 > t 4 Table 1: TLS 500 timing table 10. Start-up 1. Switch on mains and/or power up the controller. 2. Check if LED lights up Chapter 11. 3. Perform a test run with the controller using the test input Chapter 10.1. 10.1 Test run It is recommended to perform a test run with the controller: 1. Switch the test input to LOW. 2. Check the output s response Chapter 9. Important: Check the detection area of the sensor. If adjustments to the sensor calibration are needed, switch off main power and/or the controller again for your own safety. CEDES V 1.1 9

11. LED signals The TLS 500 uses a red and a green LED to indicate its status. LED signals differ between the various types of TLS 500. TLS 500 type No object Object detected PNP-DO Red LED on Green LED on PNP-LO Green LED on Red LED on NPN-DO Red LED on Green LED on NPN-LO Green LED on Red LED on Table 3: LED signals Example of LED signals for TLS 500 N-NPN-LO: Green LED on = no object detected Red LED on = object detected. The sensor cannot differentiate between an object and a person. Therefore any object entering the detection field is also detected. When an object or person does not move for more than 10 s (recalibration time), the TLS 500 accepts this object as background and switches the output to free again. The green LED lights up. green red 12. Troubleshooting Sensor status Object is in detection area but the LED indicates 'no object' No LED visible LED is blinking (N or P-type only) Detection area is free but the LED signals object detected Action Make sure the detection area length is set correctly (VR-type only) Check the sensor range in relation to the correction factor Check if the sensor is inactivated through a permanent test signal Check electrical connections Sensor sees no floor or the floor is specular (extremely reflective) Check sensor range setting (VR-type only) Make sure ambient light conditions are stable If a problem persists, please contact your local CEDES representative. Visit www.cedes.com for contact data. 13. Maintenance red green Although the TLS 500 does not need regular maintenance, a periodical functional check is strongly recommended as follows: Check the mounting position and detection area of the sensor. Clean the optical window with a soft towel and a little soapy water. < 10 s > 10 s Notice Damage to the optical window Never use any solvents, cleaners or mechanically abrasive towels or highpressure water to clean the sensor. Figure 17: LED status for the TLS 500 N-NPN-LO 14. Disposal The TLS 500 should only be replaced if a similar protection device is installed. Disposal should be carried out using the most up-to-date recycling technology according to local regulations and laws. There are no harmful materials used in the design and manufacture of the sensor. Traces of such dangerous materials may be found in the electronic components but not in quantities that are harmful. 10 CEDES V 1.1

English 15. Technical data Optical Max. operating range (on Kodak white) 6 m Diameter of active light spot at 2 m distance 0.24 m Aperture angle ±3.5 Min. distance to background 0.2 m Recalibration time (N-type) 10 s Recalibration adjust time (P-type) 3... 180 s Max. ambient light 100,000 Lux Mechanical Dimensions (w h d) 32 24 22 mm Housing material Polycarbonate (UL 94-V0) Housing color Black (other colors upon request) Enclosure rating IP65 Operating temperature range 40 C... +60 C Relative humidity (non-condensing) 0... 95 % Electrical Supply voltage USP Current consumption at 24 VDC Output Output logic Max. power-up time Max. response time Max. test response time 10... 30 VDC 12 ma PNP or NPN Light-on (LO) or dark-on (DO) 150 ms 150 ms 150 ms Connection cable and electrical connection Length 2 m Diameter Ø 3.4 mm Material PVC, black Wires AWG26 brown USP (10... 30 VDC) blue GND (0 V) black Output white Test input (N- and P-type) If no test signal is available, connect white wire with USP General EMC emission EN 61000-6-3:2007 EMC immunity EN 61000-6-2:2005 Shock EN 60068-2-27:2009 Vibration EN 60068-2-6:2008 RoHS 2011/65/EU Certificate CE CEDES V 1.1 11

English 16. Dimensions These are the most important dimensions of the TLS 500. Metric measurements (all dimensions in mm) 24.7 32 Rotates through 360 22 27.2 39.2 37.1 us measurements (all dimensions in inches) 0.97 1.25 Rotates through 360 (0.87) 1.07 1.57 1.46 16.1 Mounting bracket dimensions Dimensions in mm and inches (in brackets) Ø 3mm (0.12 in) 16 mm (0.63 in) 8 mm (0.31 in) (0.12 in) Ø 4 mm (0.16 in) Ø 3 mm CEDES AG, Science Park CH-7302 Landquart Phone: +41 81 307 2323 Fax: +41 81 307 2325 info@cedes.com www.cedes.com