TOWER TTG OPEN FRONT TTG OR6 TTG OR9 TTG OR12

Similar documents
BTGRF GLASS TOWER SERIES

BTGRF GLASS TOWER SERIES

TOWER COUNTER TOP STG

Operating Current. Height mm

Contents. NT & TAS - For orders in these states please add 5% transport surcharge to your purchase price 1-K. Price Guide - February 2017

Retail Merchandising Units

FOOD CABINETS. heated refrigerated ambient FOOD CABINETS

Energy Efficient. Flexible Design Options.

WM-4510HZD Installation Instructions

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Refrigerated Display Cabinet Installation and Operating Manual

B900/ BME900/ SKOPE Gen2: Two Door Chiller

All Freestanding SxS Refrigerators

APARTMENT MAINTENANCE SERIES

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Upright freezer V 60Hz ccl 4. Block condenser Aspera compressor grp. 38. Upright freezer compr. grp 38. Version: Date: Initials: Description:

UNIVERSAL 750 PRE-MIX DISPENSER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

A ROUGH GUIDE TO CONSTRUCT A PASSIVE SOLAR AIR HEATER

CABINET PARTS For Model: IST (White)

EXPLODED VIEWS & PARTS LISTS

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

Installation Instructions

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

CABINET PARTS For Models: ET18GKXBW00, ET18GKXBN00 (White) (Almond)

ELECTROLUX ELECTRONICALLY CONTROLLED COMPACT SIDE BY SIDE REFRIGERATOR

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

G-10f/GCG-10f UPRIGHT COOLER

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel)

CABINET PARTS For Model: IRT (White)

RPI Industries, Inc.

Mobile Air Conditioner Instruction Manual Model TC-N9KM

ER MANUAL FOR YOUR BAUMATIC

Flexible Food Service Solutions

INSTALLATION AND OPERATION MANUAL

Heated Display Cabinet Installation & Operating Instructions

361 RFD DOORS 2 \ Item # Part # - - Description. Description. Item # Part #

Global. Refrigeration, INC. QUALITY REFRIGERATION PRODUCTS Grant Avenue, Cleveland, OH

CLe-series Dishwashers

EXPLODED VIEWS & PARTS LISTS

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

Installation Instructions

SERVICE MANUAL FOR MODEL RM-10

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

RF0809 SERVICE FLASH. Frost Build Up On Upright Freezer Door Dyke SERVICE FLASH BRAND MODEL/SERIAL # CAUSE

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Silver on Black) 106.

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

User Manual. Commercial Refrigerator And Freezer User s Manual

Pegasus Series 2/1 Underbench GN

Catering & Purpose Made Equipment

CABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

SERVICE MANUAL FOR MODEL RM-26

Optimax Refrigerated Retail Merchandisers

CABINET PARTS For Models: ASD2522WRS07 (Stainless)

Rotary XL (558 Series) and Classic (548 Series)

Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets. Heated Cabinets. Blast Chillers. Blast Chillers/ Freezers

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Please read the following installation instructions first after purchasing this product or transporting it to another location.

DOCUMENT TABLE OF CONTENTS

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

CABINET PARTS For Models: ASD2522WRW03, ASD2522WRB03, ASD2522WRS03, ASD2522WRD03 (White) (Black) (Stainless) (Universal Silver)

F o o d S e r v i c e

Installation Instructions

CABINET PARTS For Models: KSBP25FKSS01 (Stainless Steel)

CABINET PARTS. For Models: KSRT25CRWH00, KSRT25CRBT00, KSRT25CRBL00, KSRT25CRSS00 (White) (Biscuit) (Black) (Stainless Steel)

CABINET PARTS. For Models: ASD2522WRW01, ASD2522WRB01, ASD2522WRS01, ASD2522WRD01 (White) (Black) (Stainless) (Universal Silver)

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

CABINET PARTS For Model: KSSO36FMX01 (Etched Aluminum)

General Display. Upright glass door fridges with ActiveCore technology + All the added options

Installation Instructions

SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

CME1856W Service Parts

CABINET PARTS For Models: KSCS25FKSS00 (Stainless Steel)

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

GCG-26c. Instruction Manual. G-Series Cooler

Installation & Service Manual

Optimax Refrigerated Retail Merchandisers

CABINET PARTS. For Models: GS5SHAXNQ02, GS5SHAXNT02, GS5SHAXNB02, GS5SHAXNS02, GS5SHAXNL02 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

CABINET PARTS For Model: KSF26C6XYY00 (Monochromatic Stainless)

Installation. Professional Built-in Hoods

Refrigeration Systems Handbook

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Mega Top Sandwich Prep Table Manual

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

CABINET PARTS For Models: KSRP25QDWH01, KSRP25QDAL01, KSRP25QDBL01 (White) (Almond) (Black)

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

Integral Kit Instructions

WESTINGHOUSE ELECTRONICALLY CONTROLLED A SERIES COMPACT SIDE BY SIDE REFRIGERATORS

ET14JKXAW01, ET14JKXAN01, ET14JKYAW01, ET14JKYAN01

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Transcription:

TOWER TTG OPEN FRONT 745 OR TTG OR6 TTG OR9 TTG OR12 394 434 205 750 Open front Three adjustable glass shelves Stainless steel hinged rear doors Deck forced refrigeration Double glazed glass ends Ticket strips on shelves and base Undershelf and canopy LED lights Pull down night blind 1500 925 178 397 528 710 750 206 195 120 600 900 1200 1500 Rear intake and extract ventilation system 745 OH TTG OH6 TTG OH9 750 Open front heated Four adjustable shelves Individual shelf heating Deck forced heating Single glazed Ticket strips on shelves and base Undershelf and canopy LED lights 1500 400 595 555 600 900 710 750 Page 1

TOWER TTG SPECIFICATIONS CABINET DIMENSIONS & SPECIFICATIONS MODEL CABINET SHELVING SHELVES SIZE FREQUENCY REFRIGERANT OPERATING CURRENT CONNECTION VOLTAGE PACKED FOR SHIPPING LENGTH (MM) DEPTH (MM) HEIGTH (MM) TOP 2ND 3RD 4TH BASE(WXD) 50/60 HZ LENGTH (MM) DEPTH (MM) HEIGTH (MM) WEIGHT (KG) TTGOR6 600 750 1500 3+BASE 490X295 790X325 790X415 NA 545X515 50/60 HZ 134A 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 830 1670 192 TTGOR9 900 750 1500 3+BASE 790X295 790X325 790X415 NA 845X515 50/60 HZ 134A 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 830 1670 246 TTGOR12 1200 750 1500 3+BASE 1090X295 1090X325 1090X415 NA 1145X515 50/60 HZ 134A 5.4AMP 10AMP 3 PIN PLUG 220~240V 1300 830 1670 300 TTGOH6 600 750 1500 4+BASE 490X255 490X335 490X415 490X415 548X595 50/60 HZ NA 9.3AMP 15AMP 3 PIN PLUG 220~240V 700 830 1670 132 TTGOH9 900 750 1500 4+BASE 790X255 790X335 790X415 790X415 848X595 50/60 HZ NA 14.6AMP 20AMP LEAD ONLY 220~240V 1000 830 1670 170 Maximum shelf load weight 15kg spread evenly Page 2

TOWER TTGOR6 Page 3

TOWER TTGOR9 Page 4

TOWER TTGOR12 1200 746 38 117 120 370 1103 B 1500 25 199 206 205 57 48 48 500 500 394 434 528 808 178 1197 A-A 709 750 Page 5

TOWER TTGOH6 498 349 52 602 A 46 746 351 150 1496 25 144 116 116 116 123 841 82 20 397 575 A A-A Page 6

116 TOWER TTGOH9 798 348 52 52 902 A 746 351 397 575 150 25 144 1496 841 124 82 46 116 116 20 Page 7 897 A A-A 549 708 750

DRAINAGE - OPTIONAL To Waste The condensate waste pipe may be plumbed directly to the building drainage system Condensate drain pipe To Waste Water Drain Page 8

BTG REAR VENTILATION Rear Ventilation Rear intake and extract ventilation system Side mounted compressor Front can be fully covered with custom panel joinery to suit environment Separation To Wall A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall Ambient air intake through right rear internally ducted through condenser face Exhaust air extract internally ducted trough left rear to enviroment Page 9

BTG OPTIONAL FRONT VENTING Standard Configuration as shipped Back to back with front venting Standard rear grill Standard front baffle Air flow intake from left rear side and exhaust through right rear side Optional Configuration - Front to Front Against a wall with front venting Rear grill removed and replaced with solid panel Front baffle panel removed and discarded Front grill detached and re-attached after configuration change Page 10 Air flow intake from left front side and exhaust through right front side

PLACEMENT GUIDES NO AIR FLOW CLEAR FLOW AIR FLOW BLOCKED too much chilled air around coil can create excessive ice build up CORRECT AIR FLOW INCORRECT AIR FLOW Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor Blocked air flow will retard operation on both HOT and COLD units Ensure trays or plates are not blocking air flow at rear Natural disruptive air flow such as cross winds can disturb the air curtain on open fronted units causing cooling to fail Locations to avoid : - Close to shop front exterior - In a high wind - In an outsdie location - Near any source producing excessive heat - In direct sunlight - Service units more frequently in dusty or polluted areas Page 11

PLACED IN BENCH DETAIL Dropped Into Benchtop Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit. MODEL CUT OUT SIZE Support Support BTG6 615 X 720 BTG9 915 X 720 BTG12 1215 X 720 Placed Into Benchtop from rear Parts removed Castors, front and side panels removed. Rear panels / grill remain for personnel safety. Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example. Support Page 12

COPS CLIP ON PANEL SYSTEM Easy install option to eliminate a nib wall Simply roll in and clip on Clip on panels offered in 16 mm MDF Melteca finish in two colour options with a gloss or matt finish 600/900/1200/100 lengths options with end panels Black Gloss or Matt White Gloss or Matt Page 13

COPS CLIP ON PANEL SYSTEM Clips screw fixed to panel Bottom edge sits flush with bottom of panel end panels Double sided velcro Integrated Clip System - Bracket fixing to joinery panels Page 14

SELF SERVICE SYSTEM SELF SERVICE SYSTEM Each unit is self contained Roll-in - Roll-out Install in minutes No on site joinery work required Ease of cleaning and servicing Mobile and flexible Easy to upgrade front panel design Custom branding strip Rear service or against wall All parts as optional component kits Ideal solution for temporary events Optional bottom shelf kit for chilled units Ensure chilled units are kept well ventilated Vent required through front panel Optional bottom meltica shelf kit - BY OTHERS Optional rear loading shelf kit 200mm deep Optional bottom meltica shelf kit - BY OTHERS Page 15

180 mm BTG ACCESSORIES Top Mounted Controller Panel For against wall installations Sold individually Base Tray - Heated Units Stainless Steel For heated units Sold in pairs Price Tabs Stainless Steel Write on with marker or adhesive tape Measure 60mm x 30mm Sold in packs of 20 Tong Holder Stainless Steel Drop into counter tray race Sold individually 100 mm 190 mm 80 mm Bag Holder 220 mm 105 mm Front and Rear Work Shelves Stainless Steel Sold individually 600-900 mm - 1200 mm - 1500 mm 300 mm Front Castor Extension Kit Increases cabinet height to 1660mm 75 mm 190 mm 600-900 mm - 1200 mm - 1500 mm 250 mm Rear Set of four, uses existing castors, includes fixing bolts and washers 280 mm 370 mm Humidity Dish Stainless Steel Perforated lid is removable 90 mm Page 16

TICKET STRIP End Profile Ticket Strip Stainless Steel Fits over front of shelves Lengths CABINET LENGTH MM TICKET STRIP LENGTH 600 475 900 775 1200 1075 Price Tabs Stainless Steel Write on with marker or adhesive tape Measure 60mm x 30mm Sold in packs of 20 Page 17

BTG ACCESSORIES OR Units - Rear door locking plate For against wall or back to back installations used to prevent rear hinged doors from being opened. Rear door handles are removed and discarded and plate is screwed in place. OR OH Units - Unit Spacer For OH and OR units. Provides a 100mm space between open fronted heated and chilled units to prevent the transfer of hot and cold air which can reduce proformance. Attached to the bottom side of one unit using exisitng screws on side panel. screws are removed and spacer is screwed in place. 100mm Page 18

MERCHANDISE TRAY Merchandise Tray Clip on stainless steel tray for all free standing units Attached to front of unit Built in ticket strip Angled base for maximum display Page 19

COLOUR WRAP OPTIONS COUNTER TOP MODEL - CURVED OR SQUARE all exterior visible areas covered DROP IN COUNTER TOP MODEL - CURVED OR SQUARE - all exterior top visible areas covered FREE STANDING - CURVED OR SQUARE all exterior visible areas covered FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE all exterior top visible areas covered 2mm gap left around rear frame Rear of units cut around serial number plate, exhaust fan and controller WRAP TRIMMINIG Page 20