Elektra F GB NO FR

Similar documents
1130 Recommended. 300 Min. 600 Recommended A B C D E F min

Original instructions. Panther 6-15 kw

OPTIFLAME ELECTRIC INSET FIRE

Original instructions AR

Original instructions. Thermoplus

Original instructions. Infrared heater IRCF...17

Original instructions. Thermoplus PL RU

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Original instructions. SIRe Basic Quick guide. SIReB

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Installation Instructions & Operating Manual IMPORTANT

SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

MICATHERMIC PANEL HEATER

OPERATING INSTRUCTIONS

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

FIGARO. 08/52543/0 (UK) Issue 1

Radiant Heater. Instruction Manual QH-200 N13275

IHC

Panel Heater Slim 1.5kw MODEL: NDK15-12K

2kW ELECTRIC HEATER WITH REMOTE CONTROL NEBRASKA NEBRASKA

OWNER'S MANUAL CERAMIC HEATER FAN ITEM NO.: MG-MTPTC113

Original instructions PAECS NO DE ES

2.8KW ELECTRIC FAN HEATER

Original instructions PAEC3200 NO DE ES

26 FIREBOX EN RU UA FR

200W Frostwatch Radiant Heater Operation Manual

2kw Remote Control Electric Fire. User and Installation Instructions

Convection Panel Heater

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ASSEMBLY AND INSTRUCTION MANUAL (EN)

5KW ELECTRIC FAN HEATER

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation and Operating Manual

OWNERS INSTRUCTION MANUAL

3KW ELECTRIC FAN HEATER

AC500T, AC1000T, AC1500T, AC2000T

Contact Details. Please note that some of the contact details on this PDF document may not be current.

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

ST E /ST E / ST E / ST E ST E / ST E / ST E

15KW ELECTRIC FAN HEATER

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

30KW ELECTRIC FAN HEATER

Curved Metal Panel Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CELSI ELECTRIFLAME XD

SP16. 08/50740/1 (UK) - Issue 1

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

General Care and Safety Guide

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

CERAMIC FAN HEATER URBAN

CERAMIC TOWER FAN HEATER PL2000

Convection Panel Heater

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

Professional HEPA Air Cleaner

METAL CERAMIC FAN HEATER

PH1000T PH1500T PH2000T

OPERATING INSTRUCTION MANUAL

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

OWNER S MANUAL OIL FILLED HEATER MODEL:NY-13A1L READ AND SAVE THESE INSTRUCTIONS

_00_0217 Printed in China.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

PLUG-IN PERSONAL CERAMIC FAN HEATER

Contact Details. Please note that some of the contact details on this PDF document may not be current.

OPERATING INSTRUCTIONS

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

IMPORTANT SAFETY INFORMATION:

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

General Care and Safety Guide

General Care and Safety Guide

16 XD Mk2 Inset Electric Fire

Imperial Electric Fires

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

Series: Convection WiFi

155mm. 820mm. 540mm E D. 940mm. 600mm

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

Classic Electric Stove

CI921 Integrated Tumble Dryer Installation, Use and Maintenance

instructions OIL FILLED RADIATOR V V and V551225

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

QUALITY SPACE HEATERS

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

AC25. Art.nr:

USER MANUAL KAHTP22XXXA

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

Micro Furnace. Ceramic Disc Heaters. Instruction Booklet

Oil-filled Radiator NY23EC-11L User Manual

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

WALL MOUNTED ELECTRIC FIREPLACE (heat blowing from the front series)

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

IMPORTANT SAFETY INFORMATION:

HS&S Alert No: 103 Date: 9 March 2017

INSTALLATION & USER INSTRUCTIONS

User and maintenance manual

Transcription:

SE... 9 GB... NO... FR... 5 DE... FI... 9 IT... NL... PL... 5 ES... RU... 9 SE GB NO FR DE FI IT NL PL ES RU Denna produkt är endast lämpad för välisolerade utrymmen eller sporadisk användning. This product is only suitable for well insulated spaces or occasional use. Dette produktet er bare egnet for velisolerte rom eller sporadisk bruk. Ce produit ne peut être utilisé que dans des locaux bien isolés ou de manière occasionnelle. Dieses Produkt ist nur für gut isolierte Räume oder für den gelegentlichen Gebrauch geeignet. Tämä tuote soveltuu ainoastaan hyvin eristettyihin tiloihin tai satunnaiseen käyttöön. Il presente prodotto è adatto solo a ambienti correttamente isolati o ad un uso occasionale. Dit product is uitsluitend geschikt voor goed geïsoleerde plaatsen of voor incidenteel gebruik. Ten produkt jest odpowiedni tylko do sporadycznego użytku lub do stosowania w dobrze izolowanych pomieszczeniach. Este producto está indicado únicamente en lugares abrigados o para una utilización puntual. Прибор пригоден к применению в местах с достаточной степенью теплоизоляции или для периодического обогрева. 8

ELF, ELF, ELF ELF9, ELF9 05/5 5 5 00 80 5 0 90/55 Fig.

Technical specifications Type Output* Output steps [kw] ) Distance to fan: 5 metres. Voltage Amperage Motor Airflow Sound level * [db(a)] [kw] [V] [A] [W] [m /h] [ C] ELF 0/ // 0V~ 9,/.5 50 00 8 ) ELF 0/ // 0V~ 8.0/5.5 0 00 5 ) ELF 0/ // 00V~.8/9. 0 00 5 ) ELF9 9 0/ /.5/9 0V~./.9 80 000 55 ) 5 0 ELF9 9 0/ /.5/9 00V~./. 80 000 55 ) 5 0 t * Weight [kg] t = Temperature rise of passing air at maximum heat output.

Elektra F 0V~ ELF Element/Værmeelement/Element/Elementii/Element/Heizelement/ Verwarmingselement Fläktmotor/Ventilator/Viftemotor/Puhallinmoottori/ Fan motor/ Gebläse motor/moteur de ventilateur/ventilatornotor Brytare/Afbryder/Bryter/Katkaisin/Switch/Schalter/Interrupteur/ Schakelaar Termostat/Termostat/Termostat/Termostaatti/Thermostat/Thermost/Thermostat/ Thermostaat Överhettningsskydd/Overophedningsbeskytter/Overhetingsvern/Ylikuumenemissuoja/ 5 Overheating cut-out/überhitzungschutz/protection contre la surchauffe/ Oververhittningsthermostaat Kontaktor/Kontaktor/Kontaktor/Kontaktori/Contactor/Schutz/Contacteur/Relais Start/Start/Start/Käynnistys/Start/Start/Démarrer/Start

Elektra F 0V~ ELF Element/Værmeelement/Element/Elementii/Element/Heizelement/ Verwarmingselement Fläktmotor/Ventilator/Viftemotor/Puhallinmoottori/ Fan motor/ Gebläse motor/moteur de ventilateur/ventilatornotor Brytare/Afbryder/Bryter/Katkaisin/Switch/Schalter/Interrupteur/ Schakelaar Termostat/Termostat/Termostat/Termostaatti/Thermostat/Thermost/Thermostat/ Thermostaat Överhettningsskydd/Overophedningsbeskytter/Overhetingsvern/Ylikuumenemissuoja/ 5 Overheating cut-out/überhitzungschutz/protection contre la surchauffe/ Oververhittningsthermostaat Kontaktor/Kontaktor/Kontaktor/Kontaktori/Contactor/Schutz/Contacteur/Relais Start/Start/Start/Käynnistys/Start/Start/Démarrer/Start 5

Elektra F 00V~ ELF Element/Værmeelement/Element/Elementii/Element/Heizelement/ Verwarmingselement Fläktmotor/Ventilator/Viftemotor/Puhallinmoottori/ Fan motor/ Gebläse motor/moteur de ventilateur/ventilatornotor Brytare/Afbryder/Bryter/Katkaisin/Switch/Schalter/Interrupteur/ Schakelaar Termostat/Termostat/Termostat/Termostaatti/Thermostat/Thermost/Thermostat/ Thermostaat Överhettningsskydd/Overophedningsbeskytter/Overhetingsvern/Ylikuumenemissuoja/ 5 Overheating cut-out/überhitzungschutz/protection contre la surchauffe/ Oververhittningsthermostaat Kontaktor/Kontaktor/Kontaktor/Kontaktori/Contactor/Schutz/Contacteur/Relais Start/Start/Start/Käynnistys/Start/Start/Démarrer/Start

Elektra F 0V~ ELF9 Element/Værmeelement/Element/Elementii/Element/Heizelement/ Verwarmingselement Fläktmotor/Ventilator/Viftemotor/Puhallinmoottori/ Fan motor/ Gebläse motor/moteur de ventilateur/ventilatornotor Brytare/Afbryder/Bryter/Katkaisin/Switch/Schalter/Interrupteur/ Schakelaar Termostat/Termostat/Termostat/Termostaatti/Thermostat/Thermost/Thermostat/ Thermostaat Överhettningsskydd/Overophedningsbeskytter/Overhetingsvern/Ylikuumenemissuoja/ 5 Overheating cut-out/überhitzungschutz/protection contre la surchauffe/ Oververhittningsthermostaat Kontaktor/Kontaktor/Kontaktor/Kontaktori/Contactor/Schutz/Contacteur/Relais Start/Start/Start/Käynnistys/Start/Start/Démarrer/Start 8 Kondensator/Kondensator/Kondensator/Kondensaattori/Capacitor/Kondensator/ Condensator,5µF

Elektra F 00V~ ELF9 Element/Værmeelement/Element/Elementii/Element/Heizelement/ Verwarmingselement Fläktmotor/Ventilator/Viftemotor/Puhallinmoottori/ Fan motor/ Gebläse motor/moteur de ventilateur/ventilatornotor Brytare/Afbryder/Bryter/Katkaisin/Switch/Schalter/Interrupteur/ Schakelaar Termostat/Termostat/Termostat/Termostaatti/Thermostat/Thermost/Thermostat/ Thermostaat Överhettningsskydd/Overophedningsbeskytter/Overhetingsvern/Ylikuumenemissuoja/ 5 Overheating cut-out/überhitzungschutz/protection contre la surchauffe/ Oververhittningsthermostaat Kontaktor/Kontaktor/Kontaktor/Kontaktori/Contactor/Schutz/Contacteur/Relais Start/Start/Start/Käynnistys/Start/Start/Démarrer/Start 8 Kondensator/Kondensator/Kondensator/Kondensaattori/Capacitor/Kondensator/ Condensator µf 8

GB Application area The fan heater is approved for rooms where there is a risk of fire, such as carpenter s workshops and farms. For portable use. The fan heater should be installed for easy maintenance and inspection. The heaters are supplied with a flexible cable and a three-phase plug. The fan heater is tested and approved according to the EMC- and SEMKO regulations and is CE compliant. Protection class: IP5 (unit) / IP (plug). The casing and heating rods are made of stainless steel SS0. Start Before starting the unit, make sure that the fan, heating rods and protection grille are free from dust and that nothing is obstructing the air flow. The unit must be restarted with the black button on the front of the unit (or with the start button on the external control panel) if : The unit has been shut off After power or safety cut-out The overheat protection has tripped out Operation The unit is equipped with mechanic thermostat room temperature control and can be used as a local space heater according to Ecodesign Regulation (EU) 05/88. The fan is running constantly unless the output selector is set in 0 position. The heat output is controlled by the built-in thermostat (0 +5 C). The on/off mode, and half or full heat output can be controlled with the output selector on the unit. Off Only fan Fan + half output Fan + full output Mounting Mount the enclosed brackets according fig. on page. Overheating Note! Opening the heater cover should only be done by a qualified installer. The heater is equipped with an overheat protection with manual reset. If it is released due to overheating, reset as follows: Disconnect the power with the fully isolated switch. Investigate the matter and repair the fault. Reset cut-out by opening the lid and pressing Mounting and assembly instruction the red button until a click is heard. Put on the lid and make sure that the screws are tightened to ensure full protection. Restart with the black button on the front panel If the fault continues, please contact a qualified technician. Safety cut-out If the installation is protected by means of a safety cut-out, which trips when the appliance is connected to RCD, this may be due to moisture in the heating element. When an appliance containing a heating element, has not been used for a long period and is stored in a damp environment, moisture can enter the element. This should not be seen as a fault, but is simply rectified by connecting the appliance to the mains supply via a socket without a safety cutout, so that the moisture can be driven out of the element. The drying time can vary from a few hours to a few days. As a preventive measure the heater should occasionally be run for a short time when it is not being used for an extended period of time. Maintenance Note! Opening the heater cover should only be done by a qualified installer. Always disconnect the power supply before opening the cover or doing any maintenance work. The appliance should be cleaned reguarly both inside and outside, to prevent overheating and risk of fire but also to guarantee long life of the heater. Note! To keep the protection class it is very important to tighten the screws properly when the lid is put back again after installation or maintenance. When the screw has reached the rubber gasket, continue another / turns.

GB Elektra F Packaging Packaging materials are chosen with consideration to environment and are therefore recyclable. Handling of product at end of working life The symbol below implies this product may contain substances necessary for functionality of product but potentially dangerous for the environment. The product should not be disposed mixed with general household waste but delivered to a designated collection point for environmental recycling. Please contact local authority for further details of your nearest designated collection point. Safety instructions Incorrect installation and/or incorrect usage of the fan heater can be hazardous. Warning! Always disconnect the fan heater berfore opening the cover or doing any electrical work. Incorrect installation can lead to personal injury. Opening the heater cover etc should only be done by a qualified installer This fan heater must not be used next to a shower, bath or swimming pool. Place the fan heater away from flammable materials Ensure that the area around the intake and exhaust grille is kept free from material which could obstruct the air flow through the unit! The unit must not be covered fully or partially with clothes, or similar materials, as overheating can result in a fire risk! The fan heater is fitted with a cable that, in the event of damage, must be changed by a qualified installer. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Children of less than years should be kept away unless continuously supervised. Children aged from years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. CAUTION Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. The guarantee is only valid if the units are used in the manner intended by the manufacturer and in accordance with the installation and maintenance instructions.

Main office Frico AB Tel: + 8 00 Box 0 SE- Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se 08-0-08 HH/CH