Whole House Action Guidelines

Similar documents
Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019

Combustion Appliance Safety Testing Guidelines

What is the purpose of the Make Safe Procedure (MSP)?

QUALITY CONTROL INSPECTION GUIDELINES V6.0

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

Southern California Edison and SoCalGas Energy Upgrade California Home Upgrade. SoCalGas

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

Inspection Checklist Mechanical Rough in

COMBUSTION SAFETY BASICS

SAN DIEGO GAS AND ELECTRIC AND SOCALGAS ENERGY UPGRADE CALIFORNIA HOME UPGRADE QUALITY CONTROL INSPECTION GUIDELINES V7.0

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

HOME INSPECTOR EDUCATION EXPO 2016

Inspection Checklist Mechanical Final

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

Summary of Changes to the ESA Program California Installation Standards Manual dated December 2014 (as of 10/30/17)

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO

USER S INFORMATION MANUAL

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

USER S INFORMATION MANUAL

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

CLEARANCES TO COMBUSTIBLES

WARNING FIRE OR EXPLOSION HAZARD.

Carbon Monoxide Safety Information

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

USER S INFORMATION MANUAL

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Manhattan Fire Protection District

Incident Summary #II (#8165) (FINAL)

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

SURE HEAT MANUFACTURING

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Montana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#

Indiana WX Oil Furnace Inspection Guide

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Bosch 80% AFUE Gas Furnace BGS80 Model

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

BPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST

WARNING FIRE OR EXPLOSION HAZARD.

Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

EnergyMeasure HOME DATA COLLECTION FORM

Retrofit Installer-Mechanical

INSTALLATION GUIDE Dual Fuel Ranges

ML180UH SERIES GAS FURNACE WARNING WARNING

Home Energy Retrofit Coordinating Committee (HERCC) Combustion Safety Testing Protocols

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

Combustion Safety Testing: What we learn from Standards and Research. Objectives. Objectives 2/24/2016

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

CHIMNEYS AND VENTS CHAPTER 8

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

LADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

SnuggPro DATA COLLECTION FORM

Integrated Ventilation System

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Building Department Informational Handout

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

TABLE OF CONTENTS. Part I Administrative... 1

2012 INTERNATIONAL FUEL GAS CODE VENTS

The Estate & The Esteem Direct Vent Fireplaces

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Installation Instructions Part No

C O D E S & A M M E N D M E N T S

Canadian Property Inspections

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

I. STRUCTURAL SYSTEMS

Chimney Fire Prevention

Incident Summary (II )

G95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL

Spray Polyurethane Foam and Open-Combustion Appliances

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

USER S INFORMATION MANUAL

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

INSTALLATION AND OPERATING INSTRUCTIONS

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

MBPA Home Performance FIELD DATA COLLECTION FORM

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Venting of Gas Fired Equipment RV

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Pro-Tech Home Inspections

PART 5: HVAC & DHW SYSTEMS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Installation Instructions

PVE SERIES POWER VENTER SYSTEM MANUAL

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Transcription:

for Pacific Gas and Electric Company's (PG&E) Whole House Rebate Progam 12/23/2011 The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event they encounter a safety issue. If any of the items below (e.g. vent termination rules and clearances, or combustion air rules) conflict with the current version of the California Mechanical Code, use the most stringent rule or interpretation. Gas Service Representative (GSR) Call Procedures: Participating contractors may attempt to repair any conditions that caused a Combustion Appliance Safety (CAS) test to fail provided they are properly licensed to do so. If the participating contractor is unable to repair any conditions that caused a CAS test to fail, the participating contractor must call a PG&E Gas Service Representative (GSR) as required by the Action Guidelines below. If a GSR call is required, contact the GSR immediately (before leaving the customer s home). To contact the GSR and schedule a visit, the participating contractor must call PG&E Central Inspection Program (CIP) Dispatch at 1-800-813-1975 during normal business hours or the PG&E Customer Service Line at 1-800-743-5000 after 5:30 PM or on weekends. The participating contractor must also notify the customer of the need for a GSR visit. For situations where a GSR call is not required and the participating contractor is not properly licensed to make the appropriate repair, the participating contractor must arrange for a properly licensed technician to repair the hazard. 1 2 3 4 5 6 7 8 COMBUSTION APPLIANCE (includes NON PG&E sources) NOT affecting the living space. Exception--water heater with vent safety issue, see Line #34. CVA IS INADEQUATE (Include capped Furnace and AWH) or CVA Measure is NOT FEASIBLE to install. DAMPER CLIP MISSING on gas log fireplace, if primary heat source. INACCESSIBLE APPLIANCE is found. Safe access cannot be gained to test any gas appliance, or no access to any appliance in a locked cabinet or room. NON PG&E Natural Gas (i.e. propane) COMBUSTION APPLIANCE that affects the living space. OPEN COMBUSTION WATER HEATER located in sleeping area. UN-VENTED GAS HEATING APPLIANCE BY DESIGN (including catalytic heaters and oven/range top/broiler -- only when used to heat home) in all areas other than sleeping areas. WHOLE HOUSE FAN when gas appliances with standing pilot (water heater/furnace) are in the attic. Pre Weatherization Evaluation Page 1

9 ACCESS DOORS BOTH MISSING from automatic water heater. 10 COMMUNICATION AT Forced Air Unit (FAU) between cold air return and products of combustion that CANNOT be fixed by Contractor. 11 COMPONENTS MISSING ON FURNACE -- appliance doors, combustion chamber door(s), and/or roll out shields. 12 GAS LEAK found for any appliance. 13 14 MICA GLASS/INSPECTION COVER on floor furnace or room heater missing or damaged. NOX ROD EQUIPED FURNACES: --Listed NOX Rod equiped horizontal furnace (1) --Vertical Furnaces with NOX Rods not properly mounted in saddles (laying on top of burners). (1) 15 SOLDERED FLEX CONNECTOR found. 16 17 18 19 20 21 22 UNCAPPED GAS LINE found and Contractor is unable to cap. (1) FURNACE / UN-VENTED GAS HEATING APPLIANCE BY DESIGN (including catalytic heaters) in sleeping area. COMMUNICATION AT FORCED AIR UNIT (FAU) between cold air return and products of combustion that CAN be fixed by Contractor. COMBUSTION VENTILATION AIR (CVA) IS INADEQUATE (Include capped Furnace and AWH) and CVA Measure is FEASIBLE to install. NON OPERATING APPLIANCE found. --Pilot Light off included. --Fireplace non op included. --Oven/Broiler/Range Top appliance group must have all burners non op before calling a GSR. ABANDONED APPLIANCE found (Flex line removed and valve/pipe capped). CVA IS INADEQUATE (Include capped Automatic Water Heater or AWH) and CVA Measure is NOT FEASIBLE to install on AWH not affecting living space. -If Communication is NOT repaired until after communication is repaired until CVA is installed. Page 2

23 NON OPERATING APPLIANCE found. --Oven/Broiler/Range Top Appliance Group, if one burner is operative then none of these appliances are considered non operative --Appliance not affecting living space 24 UNCAPPED GAS LINE found and Contractor is able to cap. Pre Weatherization Evaluation - Appliance Vent ONLY INSTALL Air Sealing AFTER VENT REPAIRED 25 SOLID FUEL CHIMNEY has a flue/vent connection to it. 26 VENT OR FLUE TERMINATION DISTANCE from a door or an operable window of a Dual Pack or Pool Heater is less than 4 ft below, 4 ft horizontally or 1 ft above. 65 Furn. 27 28 WATER HEATER OR FURNACE - VENT OR FLUE TERMINATION DISTANCE from a door or an operable window for a direct vent appliance is less than 9 in for inputs up to 50,000 BTU or 12 in for inputs greater than 50,000 up to 65,000 BTU or forced draft systems are less than 12 in. 50 AWH. 50 Furn. CHARRING of combustibles caused by appliance vent other than a furnace and/or water heater vent. 29 HEATER OR TRASH BURNER IN A RANGE/OVEN/BROILER that is not vented to the outside. -until after Vent Repaired 30 31 32 CHARRING of combustibles caused by furnace and/or water heater vent. DISCONNECTED, MISSING, GAPS, DAMAGED, RUSTED OUT OR INCORECTLY INSTALLED VENT on gas appliances such as water heater / furnace. DRAFT DIVERTER MISALIGNED. When all components (vent, draft diverter, etc.) are in place, but have been knocked out of alignment and can be realigned easily. Includes minor work such as installing tape or screws. -if Vent NOT Repaired see (1) -if Vent NOT Repaired see (1) -If Vent NOT Aligned -until after Vent Repaired -until after Vent Repaired -until after Vent Aligned 33 DRAFT DIVERTER MISSING on natural draft appliances such as water heater. -if Vent NOT Repaired see (1) -until after Vent Repaired Page 3

34 WATER HEATER not affecting the living space with a vent or flue safety issue: --Charring of combustibles --Missing/damaged/rusted out -- draft diverter -if Vent NOT Repaired see (1) 35 36 WATER HEATER DRAFT DIVERTERS -- MULTIPLE are present. EVAPORATIVE COOLER has a water heater vent or flue termination within 10 ft and not 3 ft above. -until after Vent Repaired -until after Vent Repaired 37 EVAPORATIVE COOLER has a furnace vent or flue termination within 10 ft and not 3 ft above, and an Evap Cooler Cover (this includes damper on shared duct system or exterior cover) is not pre-existing, and an Evap Cooler Cover is feasible. -until after Evap Cooler Cover Installed 38 EVAP COOLER has a furnace vent or flue termination within 10 ft and not 3 ft above, and an Evap Cooler Cover is NOT feasible or there is NO damper on a shared duct system. NOTE: If Vent not repaired, advise Customer not to run Furnace and Evap at same time. -until after Vent Repaired 39 40 41 GAS CLOTHES DRYER located within the living space: a. not exhausted to the outside of the building. b. exhausted into another appliance vent system WATER HEATER OR FURNACE VENT OR FLUE TERMINATION DISTANCE is 8 ft or more from a vertical wall or similar obstruction and it does not extend at least 1 ft above the roof. INCLUDES OUTDOOR WATER HEATER that affects the living space and is within 8 ft of a first floor wall, and the vent pipe does not terminate at least 1 ft above the first floor roof. WATER HEATER OR FURNACE VENT OR FLUE TERMINATION DISTANCE is less than 8 ft from a wall above the roof it penetrates, and does not terminate at least 2 ft above any portion of the building/obstruction within 10 ft. Appliance on Testing (Pre or Post Weatherization) -until after Exhaust Fan Vent Repaired -until after Vent Repaired -until after Vent Repaired 42 ALDEHYDE ODOR. (1) Page 4

43 44 45 46 APPLIANCE AMBIENT for furnace is 2 ppm or greater than Room Ambient. Includes Gas Log Heater (Freestanding, Insert, and Direct Vent). (1) APPLIANCE AMBIENT for Oven or Range Top or Broiler is 10 ppm or greater. Test appliance with controls at their highest setting. WIS 24-28 APPLIANCE AMBIENT for Water Heater or Gas Dryer is 10 ppm or greater. FURNACE CHAMBER CHECK found defective heat exchanger, i.e., cracks and or holes, signs of metal fatigue, excessive rust or soot, or burned out recirculation baffles. 47 DELAYED IGNITION. 48 EVIDENCE OF INCOMPLETE COMBUSTION. Excessive amounts of yellow flame (more than 50%), carbon (soot), or rust. 49 50 FLAME INTERFERENCE or distortion when FAF or counter flow wall furnace fan comes on. FLAME ROLL OUT. Continuous and/or Excessive Rollout. Water Heaters and Furnaces only. 51 FLUE READ exceeds CO Standard for Appliance Type based on Addendum 1: --FURNACE: Flue read for forced air furnace, gravity furnace, wall furnace, wall furnace direct vent, floor furnace, vented room heater, gas log heater (freestanding, insert, or direct vent), water heater or gas dryer is 101 ppm or greater (air free) (1) ; --OVEN AND BROILER: Flue read is 226 ppm or greater (as measured) ; --RANGE TOP BURNERS, GRIDDLE and GAS LOG FIREPLACE: Flue read is 26 ppm or greater (as measured). Test appliance with controls at their highest setting. 52 RADIANTS BROKEN on Room Heater. 53 ROOM AMBIENT is 10 ppm or greater. 54 SHORT CYCLING main burner on furnace. 55 SPILLAGE at draft diverter. Footnote: (1) Gas Service Representative (GSR) call required if unable to make same day Vent Repair. Page 5

Job Address EUC Participating Contractor Contractor CSLB LIcense Number CAS Test Date BPI-Certified Professional BPI ID Number BPI Professional Phone By signing above, I hereby attest that I am certified as a BPI Professional, that I personally conducted or supervised the Combustion Appliance Safety test documented on this form, and that reported test results are consistent with observed field conditions. I understand that reporting fraudulent test results may be grounds for exclusion from the PG&E Whole House Rebate Program and that I and/or my company may be held liable for any damages stemming from fraudulent test results. Instructions. This form is intended for use as a CAS data collection form for clipboard field evaluations. It is suitable for either test-in or test-out evaluations. Please enter all field data into the Data Form and upload the completed Excel file with your job submittals. Page 6