MSM - Expansion modules

Similar documents
THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Universal fault annunciator for panel mounting

Panel Mounted Fault Annunciator Series

Parameterisable compact fault annunciator with permanent display

Window facia fault annunciators

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Remote alarm indicator and test combination MK2430

ME 3011C / Alarm Indication / Quick Reference Guide

Universal fault annunciator for panel mounting

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Insulation fault evaluator EDS460-DG

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

AO Annunciator Module

Annunciator Unit SACO 16 D1. Product Guide

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Annunciator unit. Application

Analog Annunciator Unit SACO 16 A3. Product Guide

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

REA 105 Arc Protection Module. Operator s Manual

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Ordering Key. Dielectric strength

Soft Starter Centrifugal Pump Soft Starter Series

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Interface and EOL Modules 8

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Operating Manual VMD420

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

VAMP 120 & 121. Arc flash detection units. Product picture

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Installation / Monitoring Technique

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Multi-Gas-Controller MGC2

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Danfoss gas detection units

Operating Manual RCM420

TCM-2 Thyristor Control Module DATA SHEET

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

IT system floor-standing distribution

Monitoring Devices 11/1

Overload relays. General descriptions. Configuration of the front

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

VAMP 121. Arc protection unit. User manual

Wind Alarm Instrument x.x0x

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Rules for Intruder Alarm Systems

XP95 Sounder VAD Base

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

PHOTOELECTRIC AMPLIFIER SERIES

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

ACS-30-EU-EMDR- 10-MOD

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

ACCS-30. Multipoint commercial heat-tracing control system

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

On the job around the clock 24/7: Fire detection systems

Safety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

C-Bus Four Channel Analogue Output Unit Installation Instructions

Ultrasonic Proximity Sensor

Engineering Guideline. pac- Carriers Type Universal

Operating Manual TR600

CMD420 / CMD421 Series

Connections, displays and operating elements C D E G H. Installing the control unit

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

System 9000TS Sequence of Events Recorder

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

Protecting you and your home

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Transcription:

MSM - Expansion modules Transistor- and relay modules for devices of the MSM-product family Free assignment of the output arrays to the input arrays of the annunciator Triggering of relays or transistor outputs in- or output parallel to the fault annunciator Triggering of the transistor outputs according to the LED-display of the fault annunciator possible On option relay groups available as NC and / or NO - contacts Signal voltage and supply voltage range 12 V... 250 V AC/DC Connection between annunciator and expansion module with preconfectioned buscable DIN-rail housing Plug-in connection terminals 05.12.2009 Datasheet MSM-EM-DB-UK-003

MSM-EM General system description For different application cases, e.g. for providing PCS-contacts or control of a mosaiq, it is necessary to enlarge annuciators from the MSM-product family with additional outputs. Therefore relay-modules RM16 and transistor modules TM16 were developed. Mountable on DIN-rail the modules are connected to the annuciator via CAN-bus. Versions: Output groups Assignment of output groups Function of outputs Connenction to the fault annunciator RM 16 TM 16 The modules are delivered in the three following equipment configurations of relays: 16 normally closed contacts (NC) 16 normally open contacts (NO) 8 NC- / 8 NO-contacts Each 8 relays are forming an output group. Group 1 (A1... A8) Group 2 (A2... A16). There is only one variant delivered with plus-switching transistors. Each 8 outputs are forming an output group. Group 1 (A1... A8) Group 2 (A9... A16). Each group consists again of 2 subgroups with 4 transistor outputs per each By DIP switch the output groups are assigned freely to the array of inputs of a fault annunciator. By DIP switch the triggering of every output group can be set up The connection between module and annunciator is made by preconfectioned cables with RJ45-plugs. Function of the outputs Description Static, Static parallel to output Dynamic parallel to output Sequence Output follows the assigned input on the annunciator. The output is triggered as long as the according alarm is lining up. By an upcoming alarm on the input the output is set. The output is reset by acknowledgement of the alarm or receding of the alarm. The output displays the state of the corresponding LED at the fault annunciator statically. The output is reset when the alarm has receded and is acknowledged (LED flashes or shines steadily). The output displays the state of the corresponding LED at the fault annunciator dynamically. The output follows the LED. If the LED flashes, the output also changes its state in the same rhythm. The output is set when the LED shines steadily. This function is only available with transistor module. By the prerequisition that there is no negation of the outputs a set output means a High-signal at the transistor module or a pulled-in relay at the relay module. A Low-signal at the transistor module or a released relay correspond to a reset output. The outputs are not triggered by the lamp test of the fault annunciator. Page 2 of 8

expansion modules DIP-switch assignment of the relay module To configure a relay module there are 10 DIP-switches on the bottom-side of the module. With the DIPswitch 1... 5 the output group 1 (A1...A8) and with the DIP-switch 6... 10 the output group 2 (A9... A16) is configured Assignment to input Relay triggering of this group Group inversion DIP-Switch 1/6 2/7 3/8 4/9 5/10 1 8 static no OFF OFF OFF OFF OFF static yes OFF OFF OFF ON OFF static parallel to output no OFF OFF OFF OFF ON static parallel to output yes OFF OFF OFF ON ON no OFF ON ON OFF OFF yes ON ON ON ON OFF 9 16 static no ON OFF OFF OFF OFF static yes ON OFF OFF ON OFF static parallel to output no ON OFF OFF OFF ON static parallel to output yes ON OFF OFF ON ON no OFF ON ON OFF ON yes ON ON ON ON ON 17 24 static no OFF ON OFF OFF OFF static yes OFF ON OFF ON OFF static parallel to output no OFF ON OFF OFF ON static parallel to output yes OFF ON OFF ON ON no OFF ON ON ON OFF 25 32 static no ON ON OFF OFF OFF static yes ON ON OFF ON OFF static parallel to output no ON ON OFF OFF ON static parallel to output yes ON ON OFF ON ON no OFF ON ON ON ON 33 40 static no OFF OFF ON OFF OFF static yes OFF OFF ON ON OFF static parallel to output no OFF OFF ON OFF ON static parallel to output yes OFF OFF ON ON ON no ON ON ON OFF OFF 40 48 static no ON OFF ON OFF OFF static yes ON OFF ON ON OFF static parallel to output no ON OFF ON OFF ON static parallel to output yes ON OFF ON ON ON no ON ON ON OFF ON Page 3 of 8

MSM-EM State of relay contacts The state of the relay contacts is represented in the following table in dependence of the alarm inputs, the type of the relay contacts and the position of the DIP switch inverted DIP-switch inverted (4 or 9) Relay contact designed as Relay contact if alarm present Relay contact if alarm not present OFF normally open closed open open OFF normally closed open closed closed ON normally open open closed open ON normally closed closed open closed The state of relay contacts is dependent on: the group assignment (Input group of fault annunciator and output group of relay module) the control of relays (static, dependent on ackn. - parallel to Input or static parallel to output) the type of relay contacts (NO-/NC-contacts) normal or inverted (yes or no) Relay contact without supply voltage DIP-switch assignment of the transistor module On the front of the module there are two sets of DIP-switches S1.1... S1.8 and S2.1... S2.8. With switch set 1 the output group 1 is configured and with switch set 2 the output group 2. The meaning of each DIP-switch is identical on both groups. DIP- Meaning Switch 1 4 Assignment output group of the transisitor module to an input group of the fault annunciator DIP-Switch 1 2 3 4 Inputs OFF OFF OFF OFF 1 8 ON OFF OFF OFF 9 16 OFF ON OFF OFF 17 24 ON ON OFF OFF 25 32 OFF OFF ON OFF 33 40 ON OF ON OFF 41 48 5 Negation of the outputs of a group OFF - Normal (Outputs follow the fault annunciator according to the function set on the outputs) ON - Outputs get inverted 6... 8 Function of the outputs DIP-Switch 6 7 8 Function OFF OFF OFF static OFF OFF ON dependent on ackn. ON OFF OFF static parallel to output OFF ON OFF dynamic parallel to output Page of 8

expansion modules Technical Data Mechanical data Assembly DIN-rail TS35 (EN 50 022) Protection class Plastic / IP 20 Connection pluggable connection terminals Conductor cross section rigid or flexible without wiresleeves 0,2... 2,5 mm 2 with wiresleeves 0,25... 2,5 mm 2 CAN-Bus-connenction Plug Buscable RJ45 Ethernet patchcabel Cat5 IEC11801 Environmental condition Operating temperature Storage temperature Permissible relative humidity= -20 C... +60 C -20 C... +70 C 75% on average over the year; on 56 days up to 93% relative humidity On duty condensation is not permitted [Check: 40 C,93%rF > 4days] Electromagnetic compatibility Noise immunity acc. to EN 61000-4-2,3,4,5,6,12 Noise irradiation acc. to EN 61000-3-3, EN 55011 Relay module Dimensions incl. terminals (WxHxD) Weight Supply voltage 100 mm x 100 mm x 110 mm approx. 0,37 kg see table Key Nominal voltage Voltage range Power consumption 0 12 V AC/DC 10 19 V DC 8 13 V AC < 4 W 1 24 V AC/DC 19 37 V DC 14 26 V AC < 4 W 2 5 48 V AC/DC 60 V DC 110 V AC/DC 220 V AC/DC 37 73 V DC 26 51 V AC 100 370 V DC 85 264 V AC < 4 W < 7 W Load on relay contacts Dielectric strength of alternating voltage All circuits except: Relay contacts against each other and CAN-Bus-interface Dielectric strength of alternating voltage Relay contacts against each other and CAN-Bus-interface Resistance to surge voltage all circuits except for: Relay contacts against each other and CAN-Bus-interface 24... 250 V AC 2 A 110 V DC 0,5 A 220 V DC 0,3 A 4 kv RMS / 50 Hz 1 min 500 V RMS / 50 Hz 1 min 2,5 kv; 1,2 / 50 µs; 0,5 J; acc. to IEC60255-5:2000 Page 5 of 8

MSM-EM Transistor module Dimensions incl. terminals (WxHxD) Weight Nominal supply voltage Supply voltage range Power consumption Load on transistor outputs 70 mm x 107 mm x 117 mm Note: Depth plus bus cable approx. 0,24 kg 24 V DC 10... 32 V DC 1 W + load current maximum 500 ma per output Dimensional drawing RM 16 Dimensions in mm Terminal assignments RM 16 Page of 8

expansion modules Dimensional drawing TM 16 Dimensions in mm Terminal assignments TM 16 Subject to changes without prior notice Page of 8

MSM expansion modules Order description Relay module designed with 16 NO contacts Article-No Type Supply voltage 58MSMRM16000 MSM-RM-16-0-00 12 V AC/DC 58MSMRM16100 MSM-RM-16-1-00 24 V AC/DC 58MSMRM16200 MSM-RM-16-2-00 48 V AC/DC / 60 V DC 58MSMRM16500 MSM-RM-16-5-00 110-220 V AC/DC 58MSMRM16X00 MSM-RM-16-X-00 Supply voltage over CAN-Bus Transistor module with 16 contacts Article-No Type Supply and output voltage 58MSMTM16100 MSM-TM-16-1-00 24 V DC To connect the first expansion module to the fault annunciator a bus cable with 3m length is enclosed in delivery. When connecting additional modules please be advised to order cables listed in the following table depending to your installation conditions. Article no K118-0.25 K118-0.50 K118-2.00 K118-3.00 Length 0,25 m 0,50 m 2,00 m 3,00 m The full functionality of the transistor modules is only guaranteed in combination with the following versions of the BSM or respective relay modules: BSM with CAN-Bus connection from version 04912001.002 BSM with CAN-Bus connection and parameterization interface from version 05217001.001 MSMRM from version 04b23001.001 If you like to combine transistor modules with older devices, EES is providing an update service for charge to the versions listed above. On request please contact our service-team. Contact Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 71522 Backnang Germany Phone. +49 (0) 7191.182-0 Fax. +49 (0) 7191.182-200 info@ees-online.de www.ees-online.de