Mini Product Guide.

Similar documents
Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

CONTENTS SENSOR SWITCH

Lighting Control Strategies. to meet code requirements save energy and improve building performance

IECC. nlight Applications Guide.

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Interior Control Solutions

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

National Grid Small Business Program Rebate Manual

Catalog Number. Notes

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Never forget to turn the lights off again. Motion Sensors

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

11.4 lbs (5.2 kg) 13.2 lbs (6 kg) 17.6 lbs (8 kg) ORDERING INFORMATION MODEL LED COLOR TEMP. VOLTAGE LED DRIVER. 4000K (80 CRI) (Std.

Reduce lighting energy costs with controls

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

The Power To Supply... All Your Electrical Products

Product Specifications Dialog Room Controller* (*patent pending)

Sensors and Detectors

Versatile wall switch sensors maximize payback and simplify code compliance

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

0ACDT2000MV Ultasonic/Infared Occ Sensor

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

East Central College

visual environment technologies etcconnect.com

Ever evolving energy code requirements and the large demand for energy

Installation Instructions

ENERGY EFFICIENCY EXPERTS

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

DIMMING WASP Occupancy and Daylight Sensor

Maestro 0 10 V Dimmer Sensor

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Movement-based energy control

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

LIGHTING CONTROLS

ANSI/ASHRAE/IES

3 2 1 A B D F

ANSI/ASHRAE/IES

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

INTEGRATED LIGHTING CONTROLS

GE LightSweep Lighting Control System Guideform Specification

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Code Review TITLE PRESENTED BY POURIA NIKNAM

Wherever the best is needed. Sensors for professionals.

Catalog Number. Notes. Type. IBL Series Lumens Distribution Lens Voltage Color temperature

Maestro Dual-Circuit Occupancy Sensing Switch

Infrared Wall Mount Occupancy Sensor

Code Compliance Commercial Application Guide

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

Lighting Application Guide for K-12 Classrooms

The Power To Supply... All Your Electrical Products

IN2 Lighting Control Devices

miniz Quick Start Guide

Occupancy and Vacancy Sensors

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

VESICA LINEAR SUSPENDED VES L

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Catalog Number. Notes

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

North Hanover Township School District North Hanover Township, New Jersey

H-MOSS. Sensors for an Energy Conscious World

Applied Lighting Controls

Infrared Ceiling Mount Sensor

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

DHL-LP-LED Low Profile LED Linear High/Low Bay

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

WSA120: New Energy Codes and Lighting Controls

Ceiling PIR HS presence detector. Product Guide. Overview. Features

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Energy Management Products

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

Installation Instructions

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Office Title Solutions

SECTION. Occupancy Sensors & Lighting Control Products

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

SECTION LIGHTING CONTROLS

Tri-level Control Sensor

IP65 High Bay Dual Sense Sensor

Sensor Product Guide. Smart Sensing Control Solutions

Transcription:

Mini Product Guide www.acuitybrands.com/sensorswitch

Better Performance Through Advanced Technology 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor Friendly Wiring Passive Dual Technology Passive Dual Technology (PDT) utilizes both digital passive infrared (PIR) detection and Microphonics technology to see occupant motion and hear the sounds occupants make, enabling more effective detection in rooms with obstructions. More effective than sensors with two technologies that only detect motion, such as Ultrasonic and PIR Immune from conditions that typically cause false ons (e.g., non-occupant motion within a space) 100% acoustically passive - no high frequency transmissions, no potential for interference and none of the headaches common with other technologies 2 Sensor Switch

IECC Energy Code Guidelines Sensor Switch sensors can cost-effectively aid in bringing facilities up to energy code compliance. The chart below is an overview of the Code Requirements for Common Building Spaces. Please use this information as a guide. For specific code requirements, please refer to the IECC code. Space Type Control Requirement* Code Provision Code Summary* Private Office Open Office Conference, Meeting, Multipurpose Room Classroom, Lecture Hall, Training Room Manual-On or AutoOn 50% C405.2.1.1.2 Automatically controlled spaces must be controlled to automatically turn the lighting on to not more than 50% power. Full Automatic-On C405.2.1.1.2 Automatically controlled spaces are allowed to turn on to full. On-O f Control Auto-Off 50% Full Auto-Off via Occupancy Sensor C405.2.1.2 C405.2.1.1.1 Occupancy sensors shall automatically reduce lighting in warehouse aisle-ways and open areas by 50% Fixtures must automatically turn off within 30 minutes of all occupants leaving the space. (or) Time-Switch Controls (via System Controller) C405.2.2.1 Each area of the building not provided with occupant sensor controls shall be provided with time switch controls. These areas must also be provided with a manual override switch. Light Reduction Controls C405.2.2.2 Spaces shall have a manual control that allows the occupant to reduce the connected lighting load uniformly by at least 50%. (or) Manual Control (Local Switch) C405.2.2.3 Areas shall incorporate a manual control to allow occupants to turn fixtures off. Daylight Control Daylight- Responsive Controls C405.2.3.1/2 Daylight-responsive controls shall be provided within each space with sidelight and toplight daylight zones totaling > 150W. Sensor Switch 3

Wall Switch Sensors Quick & Easy Energy Savings PIR - Private Restrooms, Copy Rooms, Closets PDT - Private Office, Restroom with Stalls, Small Meeting Rooms Device accommodates powering over ground or neutral connection (patent pending); converts in seconds 100% digital PIR detection & photocell standard Small motion detection to 20 ft & large motion >36 ft Ruggedized assembly, vandal resistant lens standard Compatible w/ LEDs, Fluorescents, CFLs, & Incandescents Fully meets NEC 2011 Section 404.2C neutral requirements Programmable with the Sensor Switch VLP Mobile App! WSX WH WSX VA WSX PDT WH WSX PDT VA WSX 2P WH WSX PDT 2P WH PIR, Auto On (default) or Manual On PIR, Manual On (Vacancy) Only Dual Tech, Auto On (default) or Manual On Dual Tech, Manual On (Vacancy) Only PIR, Dual Relay (Pole 1: Auto On; Pole 2: Manual On) Dual Tech, Dual Relay (Pole 1: Auto On; Pole 2: Manual On) Conversion From Ground Only (No Neutral) To Neutral Wiring: STEP 1: Remove yellow label. STEP 2: Loosen Screws & Remove Metal Link. STEP 3: Connect Ground to Green Screw & Neutral to Silver Screw. 4 Sensor Switch

Low Voltage Sensors Ideal for Spaces Requiring Multiple Sensors Open Office, Classroom, Conference Room, Large Office, Corridor, Large Storage Area, Lobby Small motion sensors best for areas where people are stationary Large motion sensors best for areas with walking traffic Dual Tech detection required for areas with obstructions No sensitivity adjustments required - install and forget Simple push-button time delay adjustment - no tools required Utilizes power pack (PP20) to switch entire circuit Convenient mounting without junction boxes: 360 ceiling enclosure (pictured above, left) surface mounts directly to ceiling tiles 120 wide view enclosure (pictured above, right) directly mounts in a corner or to a wall Options Low Voltage Auxiliary Relay Photocell Override 0-10 VDC Dimming Low Temp / High Humidity Coverage Area* CM 9 CM PDT 9 CM 10 CM PDT 10 WV 16 WV PDT 16 360 Small Motion, PIR, Ceiling Mount 360 Small Motion, Dual Tech, Ceiling Mount 360 Large Motion, PIR, Ceiling Mount 360 Large Motion, Dual Tech, Ceiling Mount 120 Small Motion, PIR, Corner Mount 120 Small Motion, Dual Tech, Corner Mount ~12 ft (3.66 m) radius (~500 ft 2 ) ~24 ft (7.32 m) radius (~2000 ft 2 ) Small motion ~40 ft (12.19 m) Large motion ~70 ft (21.34 m) HW 13 Hallway, Large Motion, PIR, Wall Mount ~70 ft (21.34 m) when mounted at 7 ft (2.13m) *At 9 ft mounting height Power/Relay Packs Provides Low Voltage Power & Switches Lighting Powers up to 14 low voltage sensors & wall stations Rated for 20A lighting or receptacle loads PP20 Power/Relay Pack (120/277 VAC) Sensor Switch 5

Daylight Controllers Maximize Energy Savings Through Daylight Harvesting Meets daylight control code requirements for spaces with significant daylight contribution from windows or skylights Interfaces with low voltage sensors & wall controls Available in on/off or auto-dimming (0-10 VDC) versions Self-Calibrating - capable of finding optimum set-point Easy to Apply - deploy standalone or combine with occupancy sensors CM ADC LSXR ADC CM PC CMR PC Dimming Photocell, Low Voltage, 0-10 VDC, Ceiling Mount Dimming Photocell, Line Voltage, 0-10 VDC, Fixture Mount On/Off Photocell, Low Voltage, Ceiling Mount On/Off Photocell, Line Voltage, Ceiling Mount Low Voltage Switch Interfaces with Sensors to Enable Full Code Compliance Provides code-compliant manual control when applied with low voltage occupancy sensors and relay packs Alternative usage as override switch for auto-on applications Single gang enclosure with 1 or 2 on/off switches Soft-touch tactile control Optional dual manual-on operation 3X option enables unit for multi-way configurations (i.e., 3-way, 4-way, etc.) Optional 0-10 VDC dimming control SPODM SA WH SPODM 2P WH SPODM SA D WH SPODM WH Sensor Interface Switch Manual On (default) Dual Sensor Interface Switch Switch 1 Manual On / Switch 2 Auto On Sensor Interface Switch & 0-10 VDC Dimming Control - Manual On Sensor Interface Switch Auto On (default) 6 Sensor Switch

Fixture Mount Sensors Interchangeable Lenses for Maximum Versatility Warehouses, Distribution Centers, Gymnasiums, Industrial Spaces Integrated mounting bracket drops lens down 3 from chase nipple - no bracket accessory required Single or dual relay versions Single Phase 120/277 VAC and 347 VAC Two Phase 208/240 VAC and 480 VAC Photocell and 0-10 VDC dimming options Highly configurable ordering options Programmable with the Sensor Switch VLP Mobile App! Four Interchangeable Lenses Easy Lens Change #6 Lens High Mount 15 to 45 ft (4.57 to 13.72 m) mounting height #10 Lens Low Mount 7 to 15 ft (2.13 to 4.57 m) mounting height #50 Lens Aisleway bidirectional range of ~1.2 x mounting height #9 Lens Small Motion 8 to 15 ft (2.44 to 4.57 m) mounting height LSXR 610 LSXR 610 HL LSXR 610 P LSXR 610 ADC LSXR 610 2P High Mount 360 Sensor with Accessory Low Bay Lens High/Low Mount 360 Sensor with High/Low Dimming Control Option High/Low Mount 360 Sensor with On/Off Photocell Option High/Low Mount 360 Sensor with Auto Dimming Photocell Option High/Low Mount 360 Sensor with Dual Relay Control Sensor Switch 7

Application Guide The below table lists recommended sensor solutions for common spaces. Information on the full line of Sensor Switch products is available in the full product catalog or online at sensorswitch.com. Solution Options Small Office/Meeting/Break Room Wall Switch Sensor with Dimming WSX PDT D VLP Wall Switch Sensor - Manual On Wall Switch Sensor W/ Dual Relays (Pole 1 Auto On, Pole 2 Manual On) Ceiling 360 Sensor W/ Two Relay Packs And Switch WSX PDT VA WH WSX PDT 2P WH CM PDT 9, PP20 (QTY 2) & SPODM 2P WH Open Office Ceiling 360 Sensor W/ Two Relay Packs & Switch CM PDT 9 (~1 PER 30 X 30 FT AREA),PP20 (QTY 2) & SPODM 2P WH Corridor/Hallway Short Straight Hallways - Dual Hallway Sensors Longer Corridors With Alcoves/Vestibules - Ceiling 360 Sensor L-Shaped - Hallway Sensor & Ceiling 360 Sensor HW 13 (QTY 2) & PP20 (QTY 1) (OPTIONAL WV BR CEILING MOUNT BRACKET) CM 10 (1 PER ~50 FT) & PP20 (1 PER CIRCUIT OR SWITCH LEG) HW 13, CM 10, & PP20 Private Restroom/Closet Wall Switch Sensor WSX WH Ceiling 360 Sensor CM 9 & PP20 Public Restroom Wall Switch Sensor WSX PDT WH Wall Switch Sensor W/ Dual Relays For Light & Fan WSX PDT 2P WH Ceiling 360 Sensor CM PDT 9 & PP20 Classroom Wide View Sensor WV PDT 16, PP20 (QTY 2), & SPODM 2P WH Ceiling 360 Sensor CM PDT 10, PP20 (QTY 2), & SPODM 2P WH One Lithonia Way, Conyers, GA 30012 Phone: 700.922.9000 www.acuitybrands.com 2018 Acuity Brands Lighting, Inc. All Rights Reserved. SSI_8593_1118 8 Sensor Switch