Panel Mounted Fault Annunciator Series

Similar documents
Panel Mounted Fault Annunciator Series

Window facia fault annunciators

Panel Mounted Fault Annunciator Series

Universal fault annunciator for panel mounting

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Parameterisable compact fault annunciator with permanent display

Panel Mounted Fault Annunciator Series

MSM - Expansion modules

Panel Mounted Fault Annunciator Series

Universal fault annunciator for panel mounting

Annunciator Unit SACO 16 D1. Product Guide

Annunciator unit. Application

Analog Annunciator Unit SACO 16 A3. Product Guide

ME 3011C / Alarm Indication / Quick Reference Guide

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Connections, displays and operating elements C D E G H. Installing the control unit

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Remote alarm indicator and test combination MK2430

1.7. Insulation fault evaluators EDS460/490 EDS461/491

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

REA 105 Arc Protection Module. Operator s Manual

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

AO Annunciator Module

Multi-Gas-Controller MGC2

M1000 Alarm Annunciator

System 9000TS Sequence of Events Recorder

DRAFT 20 October 2014

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Interface and EOL Modules 8

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Process Alarm Solutions

M2500 Engine Controller Installation Manual

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

FCCP 200: Fume-cupboard indicator and monitor

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

Insulation fault evaluator EDS460-DG

Dew point set DS 400

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

AIS750 Series Alarm Annunciator

ACTIVE INFRARED BARRIER

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

/8 DIN Level Indicator

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Call stations and extensions

Products no longer available

ADW 535 Line type heat detector

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Labkotec Ice Detector

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Lift Station Level Controller

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

TCM-2 Thyristor Control Module DATA SHEET

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

M2000 Engine Controller

Soft Starter Centrifugal Pump Soft Starter Series

ASD 535 Aspirating smoke detector

GMA200-MW4. User Manual. Gas detection controller for wall mounting

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Operating Manual RCM420

GPS or DCF 77. DTS Masterclock

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

SIL725 Safety Annunciator

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

On the job around the clock 24/7: Fire detection systems

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

System 9000TS Event Recorder

Danfoss gas detection units

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

System 9000TS Sequence of Events Recorder

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Original operating instructions Safety switch with guard locking AC901S AC902S

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Gas Controller Module GC-06

SCAN200E USER S MANUAL

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Solution F2. Fire Alarm Control Panels one step ahead.

SmartAlarm Annunciator

The EN54 Part 2 & 4 Fire System

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

APPLICATION DATA SHEET

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

NU2 Smart Power Supply (SPS) Manual

A.M.I. J3500, J3500RS. PLC CENTRALIZATION TECHNICAL ALARMS with text display. Technical Alarm. FUNCTION : years

VACIE REFERENCE GUIDE REVISION 1.2.6

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

RAYCHEM NGC-30 COMPONENTS

Galaxy Pulsar Plus Digital Battery Plant Controller

Fire and Gas Monitoring Panel ST7-HV

Transcription:

Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case of power failure Cascading of multiple devices to an annunciating system with up to alarms possible Sealed front panel, protection class IP Integrated push buttons, function inputs, function relays, self-monitoring and internal horn All established reporting sequences implemented, USM parameterisable by Web-Server USM with communication interfaces acc. to IEC 00--0/0 or IEC 0 Optional integrated repeat-relays or DIN-rail modules for forwarding of single alarms Supply and signal voltages from V 0 V AC/DC Redundant power supply in two voltage ranges available as option Very bright bicolour-leds with large viewing angle and slide-in pockets for individual labelling of LEDs and push buttons Labelled plug-in screw terminals..0 Datasheet Datenblatt MSM-BSMUSM-DB-UK-00

BSM / usm General system description - annunciator variants The fault annunciator is available in three different categories: BSM-C: Basic version BSM-P: Software-parameterisable version USM: Annunciator with protocol interfaces The annunciators can be provided in different sizes with,,,, 0 or signal inputs. The signal inputs are arranged in groups of alarms each. The sealed front contains push buttons, bicolour-led-displays (red/green) and slide-in pockets for labelling strips. The functions alarm acknowledgement, horn acknowledgement and lamptest are fixed assigned to the buttons for BSM-C and can be parameterized freely for BSM-P and USM. The two function inputs are used according to the chosen alarm sequence (e.g. external acknowledgement). The integrated function relays are realized as change-over contacts. They are used for alarm specific functions (e.g. collective report or triggering of an external horn) as well as for signaling of malfunction through an alive-contact. All annunciators of the series BSM and USM provide a status retention in the case of power failure. This means, after power restoration the annunciator will commence the alarm processing with the alarm status of the moment of power failure. For parallel to input- or output forwarding of the single alarms by repeat-relays, two options are available:. Integration of additional relay cards ( NO contacts each) for use as repeat output. For parameterisable annunciators BSM-P and USM the relays can be freely assigned. The relay cards are available as an option and have to be considered respectively when ordering.. Connection of external relay modules through CAN-Bus interface. Further details to these expansion modules can be found in the separate datasheet MSM-EM-DB-UK. Further explanations to the implemented alarm sequences can be found in separate document Description of alarm sequences (document name SM-MA-ZI-UK). BSM-C: Basic version In the basic version, configuration of the annunciator is done by DIP-switches. The following settings can be done: Alarm sequence (first-up, no-first-up or operation indication) NO- or NC-principle of the inputs cardwise ( inputs) Horn triggering by subsequent alarms Master/slave configuration and assignment of address for cascaded annunciator system The function inputs, push buttons and function relays have the following fixed functions: Function input - external horn acknowledgement Function input - external acknowledgement Button - horn acknowledgement Button - acknowledgement Button - lamp test Button - no function assigned Relay - collective report Relay - no function assigned Relay - external horn Relay - watchdog-contact page of

panel-mounted fault annunciator Default Settings Collective report Horn Horn lock - static / parallel to output - retriggerable by subsequent alarm and manual acknowledgement - none BSM-P: Parameterisable version In addition to the characteristics of the basic version the BSM-P can be parameterised through a USB-interface and can be cascaded with additional annunciators through CAN-Bus. A description of the cascading functionality can be found at the end of this section. Parameterisation To allow for further application specific settings, every annunciator BSM-P can be parameterised by PC-software. In addition to the settings by DIP-switch numerous additional settings are available: For each single alarm channel the following parameters can be set: Signal name (labelling) Operation indication (status indication, LED green) or fault annunciation (LED red) NO- or NC-principle for each signal input Debouncing delay Alarm delay Defluttering Assignment to collective reports, or Horn triggering The alarm sequence can be compiled from the following components: First-up or no-first-up alarm - or -frequency-flashing or status indication page of

BSM / usm The following settings can be done for the horn triggering: Function Option Description Internal horn Active Internal horn is activated. Inactive Internal horn is deactivated. Horn triggering Retriggerable Horn is triggered by subsequent alarm, even if there are already alarms at issue. Not retriggerable Horn is triggered by subsequent alarms only if no alarms are at issue. Horn lock Inactive Horn can always be acknowledged. Active Horn can only be acknowledged once the alarm has been acknowledged. Horn acknowledge Manual (continuous tone) Horn is acknowledged manually by button or function input. Automatic (pulse tone) Horn is acknowledged automatically according to the set time. The different alarm sequences use different options for forming collective reports. In principle, the following variants may be used: Function static / input-parallel static / output-parallel static / dynamic / input-parallel static / dynamic / output-parallel dynamic static / input-parallel / resettable static / output-parallel / resettable Procedure The collective report is set with the first incoming alarm and resets with the last receding alarm. The collective report is set with the first incoming alarm. Once all alarms have receded and been acknowledged the collective report is reset. The collective report is set with the first incoming alarm. For each subsequent alarm, the collective report is reset for approx. 0. s and then set again. Once all alarms have receded the collective report is reset permanently. The collective report is set with the first incoming alarm. For each subsequent alarm, the collective report is reset for approx. 0. s and then set again. Once all alarms have receded and been acknowledged the collective report is reset permanently. The collective report is activated for approx. 0. s with each incoming alarm. The collective report is set with the first incoming alarm and resets with the last receding alarm or when acknowledged. The collective report is set with the first incoming alarm and reset independently from the state of the alarms by acknowledgement. The following functionalities are assignable for the buttons and functional inputs: Multiple assignments are possible: Acknowledgment lamps Group*), or Reset Group*), or Acknowledgement Horn Lamptest of the in total functional relays can be assigned with functions. The th relay is fixed designed as a live relay. Multiple assignments are possible: Collective report, or Triggering of an external horn Control of relays by a functional input ( or ) Triggering through one of the buttons (statically, as long as a button is pressed or as a bistable relay, toggles on each pressing of a button) Inversion of the relay function is possible *) A group is formed from all alarms that are triggering the same collective report. page of

panel-mounted fault annunciator Cascading With the cascading functionality up to four devices can be grouped to an annunciating system by connecting the devices via CAN-Bus interface. One device works as master and the connected devices work as slave. Thus systems with up to signal inputs (*) can be realized. Thus, the connected devices will be processing as a virtual compound annunciator with common signalling (alarm sequence, forming of collective reports and horn triggering). Acknowldegement as well as output of the collective reports and horn triggering can arbitrarily be assigned to any of the buttons or relays respectively of the compound system. When creating an annunciating system, please note that the master device has to be bigger or equal to the slave devices. As slave devices within a cascaded system, annunciators of the type BSM-C or BSM-P can be used. MSM-relay-modules cannot be connected to cascaded annunciators. General design of a cascaded fault annunicator system: Master CAN-Bus Slave Slave Slave Examples: Possible Not possible The parameterization is done at once via the browser-based software. Only the master device has to be connected, the parameterization will automatically be distributed to the slave devices. page of

BSM / usm USM: Annunciator with protocol interfaces The USM resembles the BSM-P in general functionality. For communication with superior or inferior systems (e.g. SCADA or control systems) the USM is equipped with one or two communication cards. The communication cards provide the following interfaces: Card (equipped as standard) x Ethernet / RJ x RS (optional RS) / pluggable terminal x USB-A x CAN-Bus / RJ x USB-B (factory interface) Card (optionally equipped) x Ethernet / RJ (alternatively available as optic interface of SC-type) x RS / pluggable terminal Through these interfaces the annunciators can be connected to third party systems by use of the following protocols: IEC 00--0 (annunciator is IEC-slave) IEC 00--0 (annunciator is IEC-server) IEC 0 (annunciator is IEC-server) The annunciator can establish connections to a maximum number of clients (multilink). The combination of different of the above mentioned protocols within one annunciator is possible.. USM as acquisition device SCADA System SCADA System SCADA System IEC 00--0/0 Client IEC 00--0 IEC 00--0 USM USM0 USM0 IEC 00--0/0 Server In the application example above, the USM annunciators work as acquisition devices, which process and display alarms locally. In addition the alarms are forwarded to the SCADA level through IEC 00--0 or -0. The alarm channels can either be triggered from the galvanic signal input or from the IEC interface. Which of these options is used, can be parameterized individually for each channel. Acknowledgement through the IEC interface is possible as well. page of

schalttafeleinbau-störmelder panel-mounted fault annunciator. USM as indication device USM IEC 00--0 IEC 00--0 Server In this application example the USM processes and displays alarms that are retrieved from the IEC interface. Thus, a secondary wiring of the alarms is not necessary. IEC 00--0 Client. USM in IEC 0 structures: In automated substations information from field- and protection devices are transmitted through the protocol IEC 0. In addition, various specific single point alarms are available which - depending on the type of information - need to be tranmitted to the SCADA system or to other devices on field or station level.the annunciators of the series USM adopt this rag-man functionality and provide these single point information on the integrated IEC 0 server. Individual reports and datasets can be configured easily which contain all relevant information about the alarm and device status. SCADA System IEC 00--0 Gateway With the optionally available software license IEC 0 the USM can be integrated into IEC 0 structures. IEC 0 Protection Devices USM The USM provides an integrated web-server. Thus the parameterization can be done via network with all current web browsers. All annunciator and interface parameters are available on the web-server and can be parameterized through it. No additional software or special cables are required! Service-access and online-monitoring are additional functions that are provided by the integrated web-server. page of

BSM / usm Labelling Labelling of the annunciator is done by means of designation strips that can be inserted beneath the cover foil after removing the front frame. The designation strips with signal names can be created and printed directly from the parameterisation interface or generated manually from labelling strips in Word-format. available Options The annunciators can be equipped with the following available options:. Internal relay-cards The optionally integrated relay cards ( NO contacts each) are independent from the function relays of the annunciator and can dependent of the annunciator version be used for the following functions:. In- or output-parallel multiplication and forwarding of single alarms within the annunciator without connection of external MSM-modules. Output of the collective report or external horn triggering. Triggering of the relays from the IEC-interface (only available for USM) The assignment of the relays depends from the version of the respective annunciator: BSM-C BSM-P USM - assignment of repeat relays : to signal inputs - assignment of repeat relays to signal inputs individually parameterisable - individual parameterisation which input triggers the relay or if the relay is triggered from the IEC-interface The eight normally open contacts on a relay card have one common root. The triggering and function of the relays can be parameterized by DIP-switch and by means of the parameterization software or web-server, respectively. Parameterisable settings are e.g. inversion of the signals or wipe duration for pulse outputs. page of

panel-mounted fault annunciator Available variants: BSM/USM 0-R BSM/USM -R BSM/USM -R BSM/USM * BSM/USM 0-R BSM/USM * * With the BSM/USM and BSM/USM devices internal relays cards (which means relays contacts) can be provided.. Redundant power-supply Independent from the primary power supply of the device a second, redundant power supply can be integrated into the fault annunciator. Two different voltage variants are available: 0 V AC/DC 0 0 V AC/DC The voltage level of the redundant power supply can be chosen independently from the voltage level of the primary power supply. Both primary and redundant power supplies are included in the self-monitoring of the annunciator and any malfunctions are signalized on the watchdog-contact and the OK-LED. Additionally the application of the supply voltage for both power supplies is indicated by a LED each on the rear side of the device. For the annunciators of the series USM the breakdown of a power supply is also transmitted on the communication interface. page of

BSM / usm technical Data Supply voltage U Sup Key Rated voltage Voltage range 0 V AC/DC 0 V DC or V AC V AC/DC V DC or V AC V AC/DC or 0 V DC V DC or V AC 0 V AC/DC or 0 V AC/DC 00 0 V DC or V AC Signal voltage U Sig Key Rated voltage [V AC/DC] Threshold for alarm Inactive [V AC/DC] Active [V AC/DC] Maximum permitted voltage [V AC/DC] Input current per input @ rated voltage [ma] 0, 0,, 0, E 0, 0 0 0, H 0 0, 0 00 0 0, If not otherwise specified the given information for alternating voltage are referring to a sinusoidal alternating voltage with a frequency of 0/0 Hz Power consumption Number of Power consumption [W] channels BSM BSM with integrated repeat relays USM USM with integrated repeat relays < < < < 0 < < < < < < < 0 < < < < 0 < * 0 < < < < < < < < * * The power consumption of - and -way annunciators with integrated repeat relays refers to a maximum number of relay cards ( relays). General data Buffer time in the event of failure / short circuit 00 ms * response delay BSM- -C 00 ms response delay BSM- -P, USM adjustable ( ms h) Flashing frequency single frequency flashing Hz slow flashing 0, Hz Load capacity of relay contacts... 0 V AC A; 0 V DC 0, A; 0 V DC 0, A Ethernet interface 00 Base-T / RJ * Storage of the last state of inputs and sequence in the event of power failure. page 0 of

panel-mounted fault annunciator Mechanical Data Type BSM/USM 0 0- -R* Front frame H x W x D [mm] Front panel [mm] Depth with front frame and terminals [mm] Weight [kg] x x x 00 approx. 0,0 x x x 00 approx. 0, - -R*/** - -R* x x x 00 approx. 0,0 0 0- -R* x x x 00 approx.,00 * BSM/USM- -R are variants with integrated repeat relays. ** An annunciator with signal inputs and/or nd interface card can only be realised in the variant wide (housing x mm, please refer also to variant overview on page ). Mounting panel mounting Required installation depth 0 mm Minimum horizontal gap between devices mm Connection terminals pluggable Wire cross section rigid or flexible Without wire sleeves 0,..., mm With wire sleeves 0,..., mm Ambient environment Operating ambient temperature -0 C... +0 C Storage temperature -0 C... +0 C Duty cycle 00 % Protection class at the front IP Protection class at the rear IP 0 Humidity % r.h. max. on average over the year; up to % r.h. during days; condensation during operation not permitted [Test:0 C, % r.h. > days] page of

BSM / usm Dielectric strength Voltage dielectric strength RS/RS interface against Digital inputs Relay contacts Supply (0 / 0V AC/DC) Supply ( / / V AC/DC) Relay contacts against each other Impulse withstand strength RS/RS against Digital inputs Relay contacts Supply Relay contacts against each other kv AC / 0 Hz min kv AC / 0 Hz min,0 kv AC / 0 Hz min,0 kv AC / 0 Hz min 00 V / 0 Hz min, kv ;, / 0 µs; 0, J; acc. to IEC0-:000, kv ;, / 0 µs; 0, J; acc. to IEC0-:000, kv ;, / 0 µs; 0, J; acc. to IEC0-:000 00 V ;, / 0 µs; 0, J; acc. to IEC0-:000 Electromagnetic Compatibility Noise immunity acc. to DIN EN 000--:00- DIN EN 000--:00-0 DIN EN 000--:00-0 DIN EN 000--:00-0 DIN EN 000--:00-0 DIN EN 000--:00-0 Noise irradiation acc. to DIN EN 000--:00-0 DIN EN 0:00- The devices are designed and manufactured for industrial applications according to EMC-standard. page of

panel-mounted fault annunciator terminal assignment USB CAN.. CAN CAN X X CAN CAN X X X X Live 0 Relay X Supply - + N L X S ON CFG S ON CFG X X SDP COM LAN USM SDP X BSM-P X S0 ON Signal Inputs BSM/USM0 X0 S0 ON Repeat Relays BSM/USM0-R X0 S ON X Function Input and Signal Inputs X BSM/USM S0 ON Repeat Relays X BSM/USM-R S ON Signal Inputs X BSM/USM S ON Repeat Relays X BSM/USM-R S ON Signal Inputs X BSM/USM S0 X ON Repeat Relays S ON Signal Inputs X BSM/USM0 S ON Repeat Relays X BSM/USM0-R S ON Signal Inputs X0 BSM/USM Subject to technical changes without prior notice. page of

BSM / usm ordering Code BSM-C Basic version The spacers ( X ) in the ordering code can be filed in according to the following overview: B x x x x C x x x 0 Number of Signal Inputs 0 Signal Inputs Signal Inputs* Signal Inputs Signal Inputs 0 0 Signal Inputs Signal Inputs Supply Voltage V AC/DC - 0 V AC/DC 0-0 V AC/DC Signal Voltage V AC/DC - 0 V AC/DC 0 V AC/DC H V AC/DC 0 V AC/DC LED-Colour D Bicolour-LED, colour parameterisable (red, green) X Customized mixed assembly of single-coloured LEDs Integrated Repeat-Relays 0 no repeat relays R repeat relays (for annunciator with signal inputs) R repeat relays (for annunciator with signal inputs)** R repeat relays (for annunciator with signal inputs) R 0 repeat relays (for annunciator with 0 signal inputs) Redundant Power Supply 0 no redundant power supply - 0 V AC/DC 0-0 V AC/DC B C 0 Ordering Code *) Also available in wide housing ( x mm). **) -channel annunciators with integrated repeat relay are available in wide housing ( x mm) only. Example for ordering BCDR0 BSM with signal inputs Supply voltage 0 V Signal voltage 0 V Bicolour-LEDs Repeat-relays Redundant power supply 0 V For BSM with and signal channels the option integrated repeat relays is not available. page of

panel-mounted fault annunciator BSM-P - Parameterisable Version The spacers ( X ) in the ordering code can be filled in according to the following overview: B x x x x P x x x 0 Number of Signal Inputs 0 Signal Inputs Signal Inputs* Signal Inputs Signal Inputs 0 0 Signal Inputs Signal Inputs Supply Voltage V AC/DC - 0 V AC/DC 0-0 V AC/DC Signal Voltage V AC/DC - 0 V AC/DC 0 V AC/DC H V AC/DC 0 V AC/DC LED-Colour D Bicolour-LED, colour parameterisable (red, green) X Customized mixed assembly of single-coloured LEDs Integrated Repeat-Relays 0 no repeat relays R repeat relays (for annunciator with signal inputs) R repeat relays (for annunciator with signal inputs)** R repeat relays (for annunciator with signal inputs) R 0 repeat relays (for annunciator with 0 signal inputs) repeat relays (independent from no. of signal inputs) repeat relays (independent from no. of signal inputs) Redundant Power Supply 0 no redundant power supply - 0 V AC/DC 0-0 V AC/DC B P 0 Ordering Code *) Also available in wide housing ( x mm). **) -channel annunciators with integrated repeat relay are available in wide housing ( x mm) only. Example for ordering BPDR0 Parameterisable BSM with signal inputs Supply voltage 0 V Signal voltage 0 V Bicolour-LEDs Repeat-relays Redundant power supply 0 V For BSM with and signal channels the option integrated repeat relays is not available. page of

BSM / USM USM Annunciator with protocol interfaces The spacers ( X ) in the ordering code can be filled in according to the following overview: U x x x x W x x x x Number of Signal Inputs A Signal Inputs B Signal Inputs* C Signal Inputs D Signal Inputs E 0 Signal Inputs F Signal Inputs Supply Voltage V AC/DC - 0 V AC/DC 0-0 V AC/DC Signal Voltage V AC/DC - 0 V AC/DC 0 V AC/DC H V AC/DC 0 V AC/DC Device Type E Acquisition device Protocol Interface Card W IEC00--0/-0 Protocol Interface Card 0 not equipped W IEC00--0/-0*** L IEC00--0/-0 with optical interface (Type SC)*** LED-Colour D Bicolour-LED, colour parameterisable (red, green) X Customized mixed assembly of single-coloured LEDs Integrated Repeat-Relays 0 no repeat relays R repeat relays (for annunciator with signal inputs) R repeat relays (for annunciator with signal inputs)** R repeat relays (for annunciator with signal inputs) R 0 repeat relays (for annunciator with 0 signal inputs) repeat relays (independent from no. of signal inputs) repeat relays (independent from no. of signal inputs) Redundant Power Supply 0 no redundant power supply - 0 V AC/DC 0-0 V AC/DC U W Ordering Code *) Also available in wide housing ( x mm). **) -channel annunciators with integrated repeat relay are available in wide housing ( x mm) only. ***) -channel annunciators with nd interface card are available in wide housing ( x mm) only. Ordering Code ZLICP0 - License key for IEC 0 communication Example for ordering UBEW0DR USM with signal inputs Supply voltage 0 V / Signal voltage 0 V. Interface card IEC 00--0/0. Interface card not equipped Bicolour-LEDs / Repeat-relays / Redundant power supply 0 V For USM with and signal channels the option integrated repeat relays is not available. Up to max. integrated relay cards can be equipped. These relays can be assigned to inputs or triggered from the interface.