Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Similar documents
SYX660 Commissioning Guide V Page 1 of 55

CP CP

Schneider Electric Erie T155 Series

SYX66x Commissioning Guide V Page 1 of 61

RF Programmable Room Thermostat Installation Instructions

TC-5231 Series, TC-5232, & TC-5241 Series

Programmable Room Thermostat Installation Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

Electronic Dual Cylinder Thermostat Installation Instructions

Heating controller with optimisation functions

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

PRELIMINARY EDITION

Odyssey. issue 01c. system manual

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Electronic timeswitch

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Feature Summary. I. System

RVL480. Heating Controller

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

LC2200 Level Controller Installation and Maintenance Instructions

G a

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RE-PR3-E-27 3-Phase Panel Mount 27kW

TK-1801, TK-1811 TK-1801, TKR-1811

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

LC3000 Level Controller Installation and Maintenance Instructions

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

Room thermostats with LCD for wall mounting

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Corrigo E. Second generation which contains all applications and languages

RVL481. Heating Controller. including d.h.w. heating

ECL Comfort V a.c. and 24 V a.c.

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Two-Channel Gas Controller

ES-LCD User Control SD Card Location

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

4 in 1 Digital Thermostat Control

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Oxygen (O2) Single-Point Gas Detection System

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

LORAIN CIP 4890/48120 DC Power System

RVL470. Heating Controller. Use. Functions. Series B

Tri-Stack Smart System

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

SMART THERMOSTAT WITH HOT WATER CONTROL

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

BC3250. Blowdown Controller

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

Process Alarm Module RTA 421

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

I/A Series 716C 1/16 DIN Temperature Controller

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

ST9400A User Guide. Features

D A R A - 4. Data Aire Relay Auto-Changeover

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Self-learning Room Temperature Controller

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

ECL Comfort V a.c. and 24 V a.c.

ES3247B. 3 Channel Programmer. User and Installation Instructions

UNC100 Integra Manual

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

ECL Comfort V a.c. and 24 V a.c.

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

BX444-Mc Gas Detector

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

RVP310. Heating Controller. Building Technologies HVAC Products

Room controllers with manual forced ventilation function

Series Temperature Controller Instruction Sheet

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

evotouch Controller Installation evotouch

Room thermostat with Auto Timer, Option External Input

CS-11 LCD Timeswitch: Central Time Control of Multiple Thermostats

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Installation & User Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Installation, Operating and Maintenance Manual

THX-DL Data Logger USER & INSTALLATION MANUAL V

AUTO CM CM USER GUIDE

Room thermostat with Auto Timer, Option External Input

Transcription:

Satchwell DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL DC1100 Specification No. 04-03-105 The DC1100 energy controller is a self configuring optimiser/ compensator capable of controlling one or two boilers in sequence with HWS time control. The DC1100 provides the best routines for efficient temperature control in small buildings. It is designed for easy installation and operation in the small/medium commercial property and encompasses the major control requirements of current Building Regulations. Fundamentally, the controller recognises the application by the sensors that are connected to it, so therefore it is self-configuring. The use of sensible default settings, and a self-adaptive optimiser and compensator, means that the system can be set to work after installation by programming the required temperatures and times. The controller will automatically fine tune, matching the building s requirements. Used either for controlling one boiler or two boilers in sequence with optional automatic weekly rotation, it provides stable control conditions, eliminating boiler short cycling during light load conditions. All the DC1100 s settings are accessible for adjustment, by entering a password. The simplicity does not stop there. Easy access to override the control, either by means of a front panel mounted switch, or by a remote switch unit, allows the heating to be turned on and off without the need to change the settings at the unit. In addition, one outside sensor can pass information to other DC1100s on the same site. DC1100C Specification No. 04-03-106 The DC1100C is only available as a replacement for an existing DC1100C controller. The DC1100C model allows the building to be economically and simply monitored remotely for maintenance and energy management purposes. Using the well established DC COMMS Estate Management software used by the DC2100C controller, this product can be incorporated into an existing system where this software is already installed. Connected by a telephone network and modems, access to the current performance of the heating system can be achieved. Historical records of temperature are taken at regular intervals and, perhaps most importantly, alarm information is available so that corrective measures can be taken with minimum delay, perhaps in the event of the boiler failing to fire in the morning. Full access to the controller settings allows alterations to be made via the modem link. FEATURES Self configuring controller Self adaptive optimum start Self adaptive optimum stop Day economy switch off sequence control Weekly boiler rotation Valve compensation compensation Valve/ compensation Self-adaptive compensator option Adjustable space temperature reset on compensator Night set back (space or flow temperature) Variable pump overrun Hot water time channel Multi-stage frost protection Valve/Pump summer exercise Holiday scheduling BST/GMT auto clock change Summer/Winter operation Front panel selector auto / summer / cont / frost / service Remote override facility Alarm indicator Remote communications capability (DC1100C only) Data Sheets DS 1.955 - Theta II & DC Sensors DS 3.401 - ALM Actuator DS 3.215 - ARM Actuator DS 3.005 - AVUM Actuator DS 3.201 - RM Actuator DS 2.042A - DC1100 Controller Wiring and Commissioning Information DS 2.043 - DC1100 Remote Switch Unit

SPECIFICATIONS Type: DC1100 Self Configuring Optimiser/Compensator (04-03-105) DC1100C Self Configuring Optimiser/Compensator with remote communications capability (04-03-106) Power Supply: Consumption: Fuse: Relay Ratings: 230Vac 50Hz 15VA 160mA T 250V SPNO 3A resistive 1A inductive 230Vac Ambient Temperature Limits: 0 C to 50 C Storage Temperature: -10 C to 60 C Max: Ambient Humidity: Control Range: -20 C to 120 C Accuracy: Resolution: Weight: Complies with EC Directives: Up to 95% RH non-condensing ± 0.2 C 0.1 C 1.2kg EMC, LVD ACCESSORIES DC1100 Remote Switch Unit (Part No. 04-03-109) RB1 Interface Relay (Part No. 03-21-001) COMPATIBLE DEVICES Sensors: A701 Room Temperature (see DS 1.955 for details) A702 Outside Air Temperature (see DS 1.955 for details) A703 Immersion Temperature with pocket (see DS 1.955 for details). A704 Pipe Surface Temperature (Strap-on) (see DS 1.955 for details) Actuators: ALM (see DS 3.401 for details) ARM (see DS 3.215 for details) AVUM (see DS 3.005 for details) RM (see DS 3.201for details) CONSTRUCTION Case: Protection Class: IP 40 Conduit Entries: Indication: Mounting: Plastic with transparent perspex lid 20.5mm knock-out cable entries LCD Panel providing continuous information on the DC1100 control status. Displays current date and time, one of the system temperatures and the current control action. The LCD can be used to view alarms, and in SET programming mode, the LCD is used to display setting information. A column of LEDs indicate the status of the controller, including alarms. Panel or wall mounting. Panel cut-out 186mm x 137mm with a depth clearance of 87mm at the rear. INPUTS Outside air temperature return sensor flow sensor Space sensors (2 max.) Digital input to provide for controller override OUTPUTS No. 1 No. 2 Pump Valve open Valve close Hot water 2

LCD DISPLAY SCHEMATIC TERMINAL DETAILS ** Fri 2nd Jan ** Space 1 13:33 22.0 C 18 Live Occupation A large front panel display normally shows the time, date, a selected temperature and the current operating status. It is also used to view alarms and change settings. Four keys (Up, Down, Exit and Enter) adjacent to the display are used to change settings within the controller. These are used when the front panel selector switch is set to SET. 17 16 15 14 13 Neutral Earth Hot water No.2 Valve Close 230Vac 12 Valve Open 230Vac EXIT ENTER 11 10 Pump No.1 9 Remote Switch 8 Compensated Flow FRONT PANEL SWITCH 7 Sensor Common SET 6 5 Return Flow AUTO SUMMER Earth Stud 4 3 Outside Air Sensor Common CONT 2 Space 2 FROST 1 Space 1 SERVICE The front panel switch allows control selection. This ranges from normal automatic control of heating and hot water to summer operation of hot water only, constant heating, frost protection only and a set position to change times and temperatures. A service mode allows for plant maintenance without alteration of controller settings. Input Wiring: Screened Twisted Pair, Screen Earthed at Stud only. LED INDICATORS Six LEDS indicate which functions are on, clearly showing the controller s status, and a seventh LED displays a number of operating faults: 1 2 Pump Valve open Valve close Hot water Alarm REMOTE SWITCH UNIT (Part No. 04-03-109) The Remote Switch Unit provides a means of overriding the normal control of the controller by switching the controller into one of four modes (AUTO, SUMMER, HEATING ON, HOLIDAY). This is a repeat of the function on the controller front panel switch, but allows remote operation from some convenient location. The override switch is operable only when the controller front panel switch is in the AUTO position. WARNING - ELECTRICAL SHOCK HAZARD. THIS CONTROLLER OPERATES FROM A 230Vac MAINS SUPPLY AND PROVIDES SWITCHED 230Vac OUTPUTS. ALWAYS ISOLATE THE MAINS SUPPLY FROM THE UNIT BEFORE REMOVING THE CONTROLLER FROM THE WIRING BASE. 3

TYPICAL APPLICATION DETAIL Optimisation and boiler sequence control Hot water (Option 1) A703 DC1100 A702 A701 No.1 No.2 Equipment Schedule DC1100 controller A701 Space sensor A702 Outside sensor A703 flow sensor DC1100 Features Self adaptive optimum start Optimum stop Day economy sequence control Weekly boiler rotation Pump overrun 2 Stage frost protection Pump exercise routine Holiday scheduling BST/GMT auto clock change Summer/Winter selection Alarms Options 1. Fixed time start of HWS - see hot water applications (DS 2.042A) 2. Remote Auto/Summer/Heating On/Holiday selection switch 3. Additional Space sensor for averaging 4. return sensor for frost protection 5. A704 Strap on sensor available as an alternative to the A703 Immersion sensor Controller Connection Detail Screened Cable 1 3 4 5 7 10 11 14 16 17 18 L N E 230Vac A701 Space A702 Outdoor A703 Flow No.1 Pump No.2 Earth Stud Sensor Screen Connections omitted for clarity WARNING - SEE SCHEMATIC DETAILS Note: Auxiliary relays/starters may be required if switching currents exceed 3A resistive, 1A inductive. Refer to DS 2.042A for other applications. WARNING - ELECTRICAL SHOCK HAZARD. THIS CONTROLLER OPERATES FROM A 230Vac MAINS SUPPLY AND PROVIDES SWITCHED 230Vac OUTPUTS. ALWAYS ISOLATE THE MAINS SUPPLY FROM THE UNIT BEFORE REMOVING THE CONTROLLER FROM THE WIRING BASE. 4

DIMENSION DETAILS 144 191 12 106 178 Dimensions in mm 137mm 186mm Panel Cut-out details. Allow 87mm depth. WARNINGS - ELECTRICAL SHOCK HAZARDS. THIS CONTROLLER OPERATES FROM A 230Vac MAINS SUPPLY AND PROVIDES SWITCHED 230Vac OUTPUTS. ALWAYS ISOLATE THE MAINS SUPPLY FROM THE UNIT BEFORE REMOVING THE CONTROLLER FROM THE WIRING BASE. WARNING - THIS PRODUCT CONTAINS A NICKEL-METAL HYDRIDE BATTERY WHICH IS COMPLETELY SAFE WHILST IN NORMAL USE. THE BATTERY MUST BE DISPOSED OF IN AN AUTHORISED LANDFILL SITE. Cautions Do not apply any mains or other voltages until the wiring is complete and has been checked by a qualified technician. If any equipment covers have to be removed during the installation of this equipment, ensure that they are refitted after installation to comply with UL and CE safety requirements. Do not exceed maximum ambient temperature. Interference with parts under sealed covers invalidates guarantee. Design and performance of Schneider Electric equipment is subject to improvement and therefore liable to alteration without notice. Information is given for guidance only and Schneider Electric does not accept responsibility for the selection and installation of its products unless information has been given by the Company in writing relating to a specific application. A periodic system and tuning check of the control system is recommended. Please contact your local sales office for details. On October 1st, 2009, TAC became the Buildings business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. Copyright 2010, Schneider Electric All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. All rights reserved. DS 2.042 02/10 Schneider Electric Malmö, Sweden +46 40 38 68 50 Satchwell Helpline +44 0) 1628 741100 product.support@buildings.schneider-electric.com www.schneider-electric.com/buildings