Air Liquide Advanced Technologies Division Sassenage, 38360, France

Similar documents
A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

THE TORE SUPRA CRYOGENIC SYSTEM. Design and operation

The superconducting TF magnetic system of Tore Supra

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

3.2 Cryoplant and Cryodistribution

Measured Performance of Four New 18 K Helium Refrigerators for the LHC Cryogenic System

SPECIFICATION OF FOUR NEW LARGE 4.5 K HELIUM REFRIGERATORS FOR THE LHC

AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS

HELIAL refrigerators. Range of automatic helium refrigerators

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Application Engineering

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Cryogenics for Neutral Beam Injector System

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Study on an environmental simulation system of low/high temperature. for great space

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

EN aquatech.piovan.com

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Test Report No.: Page 2 of 14

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

A 2 K Active Magnetic Regenerative Refrigeration System for Remote Cooling

Remote Helium Cooling Loops for Laboratory Applications

LARGE CRYOGENIC HELIUM REFRIGERATION SYSTEM FOR THE LHC

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Cryogenic refrigeration for the LHC

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Arrangements of cold exchangers or cold accumulators in cryogenic separation or liquefaction plants.

THERMAL ICE STORAGE: Application & Design Guide

Effect of Exhaust Gas Temperature on the Performance of Automobile Adsorption Air-Conditioner

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Performance of an Improved Household Refrigerator/Freezer

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

OPERATIONAL EXPERIENCE ON CRYOGENIC SYSTEMS FOR LARGE-SCALE ACCELERATORS AT CERN

Chapter 9. Refrigeration and Liquefaction

Cooling test results C-side replacement detector

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

(Refer Slide Time: 00:00:40 min)

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Pocket Dilution Cooler

Reliability and availability analysis of a 10 K helium refrigerator

Industrial Oxygen Generation Plant

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ESS Accelerator Cryoplant Process Design

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Heat pump supplemental heating system for motor vehicles

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Last exam / sista tent

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Development of a measurement and control system for a 10 K refrigerator based on Siemens PLC S7-300

10 K Airborne Cryocooler and

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

REFRIGERATED AIR DRYERS

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

A study of Transient Performance of A Cascade Heat Pump System

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Transcription:

Published in AIP Conference Proceedings 1218, pp. 1476-1483 (2010) OPERATION RESULTS OF THE KSTAR HELIUM REFRIGERATION SYSTEM H.- S. Chang1, E. Fauve2, D.-S. Park1, J.-J. Joo1, K.-M. Moon1, K.-W. Cho1, H. K. Na1, M. Kwon1, S.-H. Yang3, and G. Gistau-Baguer4 1 National Fusion Research Center Daejeon, 305-333, Korea 2 Air Liquide Advanced Technologies Division Sassenage, 38360, France 3 Cryogenic Engineering Inc. Goyang, 411-718, Korea 4 Consultant Biviers, 38330, France ABSTRACT The first plasma (100 ka of controllable plasma current for 100 ms) of KSTAR has been successfully generated in July 2008. The major outstanding feature of KSTAR compared to most other Tokamaks is that all the magnet coils are superconducting (SC), which enables higher plasma current values for a longer time duration when the nominal operation status has been reached. However, to establish the operating condition for the SC coils, other cold components, such as thermal shields, coil-supporting structures, SC buslines, and current leads also must be maintained at proper cryogenic temperature levels. A helium refrigeration system (HRS) with an exergetic equivalent cooling power of 9 kw at 4.5 K has been installed for such purposes and successfully commissioned. In this proceeding, we will report on the operation results of the HRS during the first plasma campaign of KSTAR. Using the HRS, the 300-ton cold mass of KSTAR was cooled down from ambient to the operating temperature levels of each cold component. Stable and steady cryogenic conditions, proper for the generation of the first plasma have been maintained for three months, after which, all of the cold mass was warmed up again to ambient temperature. KEYWORDS: Fusion, Tokamak, superconducting magnets, helium refrigeration, supercritical helium, liquid helium. Page 1 of 8

INTRODUCTION After successful commissioning [1], the first task for the HRS was the conditioning of the contaminated cooling channels of the KSTAR cold components to prepare for the cool down and consequent first plasma campaign of KSTAR. The conditioning activities had been accomplished within one week, after which, the cool down of KSTAR was initiated. The cool down itself, which took about 21 days, had been declared to be achieved when the temperature of the return gaseous helium (GHe) collected from the KSTAR cold components reached about 5 K. After turning on the cold GHe compressor and the two supercritical helium (SHe) circulators in order to supply the SC magnets with large SHe mass flow rate values at 4.3 K proper for current charging, the cryogenic conditions for plasma experiments were fulfilled. Except for a major trip, which stopped the whole HRS and required two days for full recovery, such conditions had been maintained for three months in a very stable and steady-state manner. The warm up of KSTAR, which completed the operation cycle of the HRS, took about 14 days and was considered as finished when the GHe temperatures collected from KSTAR were close to 250 K. CONDITIONING, COOL DOWN, AND WARM UP OF KSTAR Conditioning Before starting the cool down, the helium cooling channels of the KSTAR cold components must be conditioned free of any impurities such as air, water, and solvents. Impurities solidify during cool down and later become potential risk factors which can damage the cryogenic turbo-rotating machines (turbines, cold GHe compressor, SHe circulators) and/or clog the tiny helium paths of the cable-in-conduit conductors (CICC) the SC magnet coils and bus-lines (BL) consist of. The conditioning activities had been performed in two phases. First conventional pumping and (GHe) filling had been applied to all cooling channels three times (or more if necessary) until the dew-point of the last filled GHe was less than -65 oc. The results varied between -71 oc and -85 oc. Then, in the case of cooling channels which consist of CICC, such as SC coils and BL, GHe with a maximum mass flow rate of 90 g/s at 18.5 bars (1 bar=105 Pa) had been flushed across and its impurities analyzed. Flushing was stopped when the N2 and H2O concentrations in the GHe downstream the CICC cooling channels indicated less than 5 ppm. Cool Down and Warm Up The cool down of KSTAR was launched after completion of the conditioning works. The temperature of the GHe dedicated for cool down had been adjusted by mixing different temperature levels from the high pressure (HP) GHe stream of the cold box (C/B) and manipulating the cooling power of the expansion turbines. The GHe collected after passing the cooling channels joined the low pressure (LP) return C/B stream, also at different temperature levels in order to keep the C/B temperature distribution as balanced as possible. The SC magnets and BL are implemented with GHe supply/return lines exclusively assigned for cool down and warm up only whereas the thermal shields (TS) and current leads (CL) use the same lines as during normal operation. Special care had been taken during cool down such that the temperature difference between the supply and return GHe did not exceed 50 K and the speed of cool down was not faster than -1 K/hr. Page 2 of 8

FIGURE 1. (a) Cool down and (b) warm up curve of the KSTAR cold components. FIGURE 1(a) shows the temperature evolution of the supply/return GHe during the cool down period. Depending on the minimum GHe temperature required, turbines had been turned on one by one, and the C/B was cooled down along with KSTAR. The temperature difference between the supply and return GHe had been kept below 40 K and the average cool down speed was -0.63 K/hr. A trip which stopped the whole HRS occurred due to a failure of the main power supply when the supply GHe temperature was about 100 K. However, since it was far from liquid helium (LHe) production, the full recovery took only 2 hours after recognizing the cause of the trip. The warm up of KSTAR used the same GHe supply/return strategy as during cool down, except that the supply GHe temperature was increased with time (on the average by +0.73 K/hr). As shown in FIGURE 1(b) the GHe supply to the TS had been terminated when the return temperature was about 200 K. The HRS, and therefore the whole warm up, was stopped when the GHe temperatures collected from the magnets and bus-lines reached 250 K. STEADY STATE OPERATION OF THE HRS During the plasma experiments, for all plants and facilities related to the operation of the KSTAR Tokamak, utmost priority was given to safety and stability. For the sake of operational stability, the HRS had been operated with a cooling capacity much larger than necessary despite higher power consumption and therefore increased operation expenses. Page 3 of 8

FIGURE 2. Operation results of the WCS during the plasma experimental period. Shaded region designate the major TRIP and following recovery term (applies to all figures hereafter). Warm Compression System The warm compression system (WCS), which compresses the GHe to be expanded in the C/B via turbines in order to generate the COLD and collects all evaporated LHe used for cooling, plays the major role in the stable operation of the HRS. As shown in FIGURE 2, the three pressure levels of the WCS had been maintained with only 1~3 % deviation for three months. The by-pass GHe mass flow rate from HP to LP cycle (LPBP) indicates the overcapacity and therefore the operational margin of the WCS. From the viewpoint of the WCS alone, the LPBP mass flow rate, which was almost always kept higher than 100 g/s, corresponds to the excess LHe evaporation (equivalent to 2 kw extra heat load at 4.5 K) that can be handled by the WCS. The major trip and following recovery period highlighted on FIGURE 2 (shaded region) was related to the breakdown of one of the oil pumps. The loss of oil pressure caused the WCS to trip and consequently the trip of the entire HRS. The WCS was equipped with redundant oil pumps allowing quick restart of the system. Nevertheless, two days were required to return KSTAR to normal operating conditions. Cold Box The C/B of the KSTAR HRS is equipped with 6 oil-free static GHe bearing expansion turbines. The C/B is designed to produce an exergetic equivalent cooling power of 9 kw at 4.5 K via quasi-isentropic expansion of the turbines without liquid nitrogen precooling. The turbines were operated fully automatically. The only accessible parameter is their rotational speed which is a result of changing the inlet pressure and consequently processed mass flow rate. Variation of the rotational speed of each turbine had been performed according to attenuation logics related to their stability and safety. Attenuators linked to the level of the LHe storage directly controlled the capacity of the C/B. A three month trend of the rotational speed of the 6 turbines is shown in FIGURE 3. Except for turbine T1, the curves are rising with time which cause is suspected to be some moisture accumulation on the first heat exchanger (HX) block inside the C/B. Periodic peaks in the speed curves occurred whenever one of the double bed 80 K or single bed 20 K adsorbers inside the C/B were regenerated. The turbines were operated at 78~93 % of their maximum rotational speed values which correspond to 48~79 % of the maximum Page 4 of 8

FIGURE 3. Rotational speed curves of the six turbines T1~T6 during the plasma experimental period. TABLE 1. Suction/discharge helium parameters, and related isentropic efficiency of the turbines T1~T6 (measured on 18th July, 2008). For * and ** refer to corresponding parts in the text. Pin (bar) Pout (bar) Tin (K) Tout (K) Efficiency T1 17.69 12.56 195.06 177.6 0.70 T2 10.97 4.83 123.92 98.33 0.74 T3 13.48 4.81 73.48 52.28 ** 0.86 T4 17.57 4.83 48.8 37.62 * 0.57 T5 14.27 1.21 27.8 14.66 0.74 T6 15.39 2.94 8.5 5.55 ** 0.96 cooling capacity. TABLE 1 shows the isentropic efficiencies from the data extracted on 18th of July, 2008. As already mentioned elsewhere [1], turbine T4 was operated at offdesign operating conditions, resulting in a rather low efficiency (*of Table 1), whereas the unusual high efficiency of T3 could be accounted to the uncertainty of the temperature measurements and has almost obviously the same reason in the case of T6 (**of Table 1). By using empirical formulae [2] to get the mass flow rates across the turbines and calculating the enthalpy balance at the cold end of the C/B, the isothermal cooling capacity of the C/B turns out to be about 5~5.5 kw at 4.3 K (temperature of the LHe inside the thermal damper where isothermal cooling takes place) during the plasma experimental period. Distribution Box The distribution box (D/B) converts the cryogenic helium (LHe, SHe, GHe) produced in the C/B into a state proper for cooling the KSTAR cold components by modifying the pressure, mass flow rate, and temperature. Since the cooling of the TS, SC BL, and CL are rather straightforward and mainly consist of supply and return of cryogens, this section will focus on the cooling of the SC magnets during the KSTAR plasma experiments. A schematic cooling scheme of the KSTAR Tokamak from the viewpoint of the D/B is shown in FIGURE 4. GHe (15.8 bar, 42~52 K, 190~220 g/s) was supplied directly from the C/B to the TS and after cooling (14 bar, 52~67 K) returned back to the C/B cycle. The CL were supplied with LHe (4.54 K, 1.35 bar, 5 g/s) from the LHe storage which was heated up to ambient temperature and discharged to the LP cycle of the WCS. These nonisothermal cooling schemes of the TS and CL used on the average an exergetic equivalent Page 5 of 8

FIGURE 4. Cooling scheme of KSTAR. Thick lines designate the helium flow during normal operation. cooling power of 0.9~1.3 kw and 0.5 kw at 4.5 K, respectively. Considering the isothermal cooling capacity, the C/B had been operated on the average at about 7 kw at 4.5 K exergetic equivalent during the KSTAR plasma experimental period. The SC BL were supplied with SHe (7 bar, 5~5.5 K, 40~50 g/s) issued from the C/B which was cooled down to 4.4 K via a HX immersed in the LHe of the so called thermal damper (TD) and its pressure reduced down to 3.5 bar by cryogenic valves. The depressurized and heated SHe (>3 bar, ~5 K) discharged from the SC BL was expanded into the TD at 1.1 bar. The TD is a vessel with a volume of 6 m3 where LHe supplied from the LHe storage is accumulated and vaporized by heat loads generated during the cooling of the SC magnets and BL. FIGURE 5 shows the operation results of the TD during the KSTAR plasma experiments. The temperature of the LHe inside the TD was maintained close to 4.3 K by operating the cold GHe compressor (C9 of FIGURE 4) at 180~220 Hz and thereby FIGURE 5. Operation results of the TD during the plasma experimental period of KSTAR. Page 6 of 8

keeping the vapor pressure close to 1.1 bar. The LHe level of the TD was controlled at 50 % by the LHe supply valve. On the other hand the LHe level of the LHe storage was controlled at 15~20 % by two heaters immersed in the LHe of the TD. The heaters were also linked to the attenuation logic of the WCS LP cycle pressure to reduce their values in case of excess return cold GHe flow due to increased heat load from KSTAR. The large fluctuations of the heater values were mainly due to the LHe supply variation to the CL. To cool the toroidal field (TF) and poloidal field (PF) SC magnets of KSTAR, two closed-loop SHe circuits each with one SHe circulator and three HX s immersed in the LHe of the TD have been set up. The SHe was pressurized from 4.2 bar to 6.5~6.9 bar by the SHe circulators (C1 and C2 of FIGURE 4, respectively) and issued to the serially connected cooling channels of the magnet coils and structures. After pressurization by the circulators and discharge from the magnet coils or structures, the heated SHe was cooled via the HX s (E110/210 and E120/220 or E129/229 of FIGURE 4, respectively) down to 4.4 K. The operation results of the magnet cooling circuits are shown in FIGURE 6. The rotational speed of the circulators, therefore the SHe mass flow rate and pressure head were FIGURE 6. SHe and circulator parameters during the plasma experimental period in case of the (a) TF and (b) PF magnet cooling circuit. Page 7 of 8

held at constant values. Thanks to the effective cooling of the thermo-siphon type LHe/SHe HX s, the temperature values downstream those HX s were always close to 4.4 K, within the measurement accuracy of the temperature sensors (±0.1 K). Since the magnet coils were only partially charged (TF: 15 ka, PF: 4 ka maximum) compared to design values (TF: 35 ka, PF: 21 ka maximum) all the SHe and circulator parameters were almost always very stable. In the case of the TF magnet circuit in FIGURE 6(a), rather periodic fluctuations of the SHe and circulator parameters can be observed. They result from some heat in-leak accumulation due to a too short connection of a pressure safety valve (PSV) with the SHe process line on the secondary distribution box (D/B #2). Since the return SHe lines of the TF and PF magnets are thermally connected to form a 5 K shield inside the cryogenic transfer lines between KSTAR and the D/B, depending on the amount of the heat in-leak, similar fluctuations, distinguished by large drops in the mass flow rate, can be observed in the PF circuit in FIGURE 6(b). However, by cooling the PSV connection point with SHe periodically, it was possible to make the fluctuations happen only when all the magnet coils were discharged during the night shift. Small fluctuations in the PF circuit were due to the fast charging and discharging of the magnet coils and never had visible effects on the TF circuit. Anyway, all those fluctuations scarcely affected the SHe temperature downstream the HX s and it was always possible to maintain a safe and steady state cryogenic operating condition for the SC magnets during the plasma experimental period of KSTAR. CONCLUSION By operating the HRS, the cryogenic conditions proper for charging the SC magnet coils and generating the first plasma of the KSTAR Tokamak had been maintained for three months in a very stable and steady-state manner. Previous commissioning results [1] and cooling capacity margins observed during the first plasma campaign strongly indicate the capability of the HRS to cope with the future 2 MA-plasma-current scenario of KSTAR [3]. ACKNOWLEDGEMENTS This work was supported by the Ministry of Education, Science and Technology under the KSTAR Project. REFERENCES 1. 2. 3. Chang, H.-S. et al., Proceedings of the 22nd ICEC and ICMC Conference 2008, pp. 675-680 (2009). Fauve, E., Functional Analysis of the Cold Box, KSTAR HRS Project Documentation, March 2008. Alekseev A. et al., Thermo-Hydraulic Analysis of the KSTAR Magnet System, KSTAR Project Internal Release Documentation, December 2002. Page 8 of 8