PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

Similar documents
80 Watts FLANGE FINISH

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

OPTIONAL LENS 2 FLANGE FINISH

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

USAI ADJUSTABLE. Lighting

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

PROJECT INFORMATION PROJECT DATE TYPE

1" Regress Trim DELIVERED PERFORMANCE - Downlight

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION PROJECT

PROJECT INFORMATION FLANGE FINISH

DATE TYPE 40 DELIVERED PERFORMANCE

BeveLED 2.1 PROJECT INFORMATION

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

NanoLED NXT Cylinder LNRP3 Surface

SliverLED Round Downlight, 1 Regress SR11

SliverLED Round Adjustable, Wet Location SR21W

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

Field changeable between Trimmed / Trimless / Millwork

Field changeable between Trimmed / Trimless / Millwork

BeveLED Cylinder LBRP6 Surface

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

True Zero Conceal - Z3SA-C 3 Square Adjustable

BeveLED Cylinder LBRP6 Pendant

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

BeveLED Mini Trimless Acoustical - B3RDP

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

PROJECT DATE FLANGE FINISH

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3SD 3 Square Downlight

BeveLED Mini - B3RD 3 Round Downlight

BeveLED Mini - B3RA 3 Round Adjustable

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

Micro Wall Wash Trimless - MWL

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

IHOL-6DR / IRD600 6 Gravity LED Downlight

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Classix 6" 6" Round Adjustable C3

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Classix 6" 6" Round Adjustable C3M

Evoke Square Downlight

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Round Adjustable C3

RFP Grand Entry Canopies Addendum 002 Issued July 16, 2013

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Essenza. Square Downlights

Essenza. Round Downlights

Grüv Flare Regressed. Recessed Linear LED

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Evoke Square Downlight

Performance Chart Electrical Data

Performance Chart Electrical Data

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Performance Chart Electrical Data

Evoke Square Adjustable HP

Evoke Round Downlight

Hornet HP. Round Glass Downlight

Etch 2' x 2' Recessed LED

Performance Chart Electrical Data

Transcription:

Beve 5.0 MAX OUTPUT PROJECT INFORMATION PROJECT DATE TYPE Beve 5.0 Recessed Downlight - Beve 5.0 provides maximum delivered lumens and optical performance through the optimization of thermal, optical, and science in a 6 aperture. Best-in-class quality downlighting for high ceiling applications and projects where more light is needed. 1 REGRESS DELIVERED PERFORMANCE Beve 2.1 1 REGRESS 40 Watts 60 Watts 80 Watts 1" Regress 4-7/8 Ø 6 Ø 7 Ø 1" Regress Bevel Finish Flange Finish Color Rendering 80+ 80+ 80+ Lumens per Watt 85 77 70 Source Lumens 4000 5400 6650 Delivered Lumens 3400 4600 5675 Color Consistency 2 Step MacAdam Ellipse Performance based on: 3000K, 50 beam CCT MULTIPLIER 2700K 3000K 3500K 4000K 80+ 80+ 80+ 80+ Color Rendering Index CRI CRI CRI CRI Multiplier for Lumen Output 0.91 1.00 1.00 1.09 DEEP REGRESS DELIVERED PERFORMANCE Beve 2.1 DEEP REGRESS 40 Watts 60 Watts 80 Watts Deep Regress 2 1 2" Regress Color Rendering 80+ 80+ 80+ Lumens per Watt 72 65 60 Source Lumens 4000 5400 6650 Delivered Lumens 2875 3875 4800 Color Consistency 2 Step MacAdam Ellipse 67º Cutoff Bevel Finish Flange Finish Performance based on: 3000K, 50 beam CCT MULTIPLIER 2700K 3000K 3500K 4000K 80+ 80+ 80+ 80+ Color Rendering Index CRI CRI CRI CRI Multiplier for Lumen Output 0.91 1.00 1.00 1.09 4-7/8 Ø 6 Ø 7 Ø 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT ORDERING INFORMATION 1 REGRESS DEEP REGRESS HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: W - B1- S - 10 - LRTD6-9040 - C2-27KS - 50 - NC1-277V - DIML2 - CB27 TRIM ORDERING INFORMATION TRIM OPTION BEVEL STYLE LENS FLANGE FINISH Round Downlight 1" Regress Round Downlight Deep Regress 1 REGRESS W Wet location 1 DEEP REGRESS W Wet location 1 1 Wet location, use with B1 and B2 trims only. B1 1" Regress Bevel, Painted Die Cast Matches Flange Finish AB1 1" Regress Bevel, Black Anodized AC1 1" Regress Bevel, Clear Matte Anodized B2 2-1/2 Regress Bevel, Painted Die Cast 3 Matches Flange Finish AB2 2-1/2 Regress Bevel, Black Anodized 3 AC2 2-1/2 Regress Bevel, Clear Matte Anodized S Solite (provided standard) F Frosted 01 Clear Matte (AC Bevel only) 02 Black Anodized (AB Bevel Only) 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) HOUSING ORDERING INFORMATION ENGINE HOUSING CODE WATTAGE CODE COLOR REFLECTOR HOUSING TYPE LRTD6 C2 LRTD6 9040 40W 9060 60W 9080 80W See performance chart for precise lumen information. C2 27KS 2700K, 80+ CRI 30KS 3000K, 80+ CRI 35KS 3500K, 80+ CRI 40KS 4000K, 80+ CRI 2 Step MacAdam ellipse is standard for all 1 REGRESS 40 40 beam 50 50 beam 60 60 beam 80 80 beam C35 35 beam Comfort Cutoff C40 40 beam Comfort Cutoff C55 55 beam Comfort Cutoff C70 70 beam Comfort Cutoff NC1 New Construction 1-1/8 Maximum Ceiling Thickness NC2 New Construction 2-3/8 Maximum Ceiling Thickness DEEP REGRESS NC2 New Construction 2-3/8 Maximum Ceiling Thickness SELECT ONE VOLTAGE 120V 277V 120V DIMMING OPTIONS For use with 120V or 277V DIML2 0-10V dim, 10% (provided standard) DIML4 Lutron A 3-wire/ECO, 1% DIML6A Eldo 0-10V, 0.1%, logarithmic / Lutron controls DIML6B Eldo 0-10V Linear, 0.1%, linear controls DIML6E Eldo 0-10V, 1%, logarithmic/lutron controls DIML6F Eldo 0-10V, 1%, linear controls DIML7 Eldo DALI, 0.1% DIML8 Eldo DMX, 0.1% 2 For use with 120V only DIML3 Lutron A 2-wire, 1% 120V only 2 Note: N/A with 80W ACCESSORIES CB27 27" C-Channel Bars CB52 52" C-Channel Bars EML Emergency battery 3 EMLW Emergency battery, wet location 3 3 Requires above ceiling access for service 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT HOUSING INFORMATION NC2 HOUSING BELOW IS FOR USE WITH 1 REGRESS TRIMS & DEEP REGRESS TRIMS New Construction Housing - NC2 (40W) New Construction Housing - NC2 - (60W, 80W) 5-5/8 6-5/8 2-3/8 max. ceiling thickness 21 (includes butterfly brackets) 2-3/8 21 (includes butterfly brackets) New Construction w/ Emergency EM 13-5/8 13-5/8 13-5/8 16-1/4 6-3/8 18 6-3/8 18 6-3/8 18 21 NC1 HOUSING BELOW ARE FOR USE WITH 1 REGRESS TRIMS ONLY (NC1 IS NOT AVAILABLE FOR USE WITH DEEP REGRESS) New Construction Housing - NC1 (40W) New Construction Housing - NC1 (60W, 80W) 5-5/8 6-5/8 1-1/8 max. ceiling thickness 21 (includes butterfly brackets) 1-1/8 max. ceiling thickness 21 (includes butterfly brackets) New Construction w/ Emergency EM 13-5/8 13-5/8 13-5/8 16-1/4 6-3/8 18 6-3/8 18 6-3/8 18 21 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT SPECIFICATIONS TRIM: 6 round aperture with a 1 regress or deep regress bevel and 1/2 flange, retained by two mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized gray painted finishes, with flange painted to match. Also available in black or clear matte anodized finishes, with self-finish or contrasting painted flange. Custom colors are available (provide RAL#). Trim is shipped with a solite lens provided standard. Some examples of standard trim finish options for are shown below: B1 - Painted Die Cast Trim 10 - White Bevel & Flange B1 - Painted Die Cast Trim 13 - Statuary Bronze Bevel & Flange B1 - Painted Die Cast Trim 21 - Black Bevel & Flange B1 - Painted Die Cast Trim 28 - Metalized Grey Bevel & Flange AC1 - Clear Matte Anodozed Bevel 01 - Clear Matte Flange AC1 - Clear Matte Anodized Bevel 10 - White Flange AB1 - Black Anodized Bevel 02 - Black Anodized Flange AB1 - Black Anodized Bevel 13 - Statuary Bronze Flange AB1 - Black Anodized Bevel 28 - Metalized Grey Flange AC2 - Clear Matte Anodized Bevel 01 - Clear Matte Flange AC2 - Clear Matte Anodized Bevel 10 - White Flange AB2 - Black Anodized Bevel 02 - Black Anodized Flange AB2 - Black Anodized Bevel 13 - Statuary Bronze Flange AB2 - Black Anodized Bevel 28 - Metalized Grey Flange FIELD REPLACEABLE LIGHT ENGINE: is serviceable through the aperture without tools. All Classic White light engines feature industry leading color consistency within a 2-Step MacAdam s ellipse. FIELD REPLACEABLE DIMMING PER : 0-10V, 100%-10% solid state electronic constant current DIML2 dimming driver with a high power factor provided standard and sources 2mA per 40W fixture and 4mA per 60W or 80W fixture. Specify 120V or 277V. Driver complies with IEEEC62.41 surge protection. Multiple dimming driver options are available; some on-time delay may be experienced, depending on control system used. EMERGENCY: Emergency lighting battery pack with remote charging indicator light requires above ceiling access. Bodine BSL20LV provides 700mA for 90 minutes; delivers ~1500 lumens. EMLW wet location option available with B1 and B2 trims. HOUSING: 1 regress fixture housing options are NC1 and NC2. DEEP regress fixture housing options are NC2 only. NC1 housing is not available with DEEP regress trims. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14 to 24 centers. C-channel bars are optionally available for acoustical ceiling applications. MAXIMUM CEILING THICKNESS: As noted on housing drawings. CEILING CUT OUT: 6-5/8 Ø WARRANTY: Based on IESNA LM80-2008, Beve 5.0 has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. LISTINGS: Dry/Damp. Wet location option available with B1 and B2 trims only. NRTL/CSA-US tested to UL standards. IBEW union made. NOTES: Not for use in corrosive environment. Use of pressure washer voids warranty. Servicable from above. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79. 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT 5.0 DELIVERED PERFORMANCE / 6321 40W 30KS 40 1 Regress / 6321 40W 30KS 50 1 Regress 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT 5.0 DELIVERED PERFORMANCE / 6321 40W 30KS 60 1 Regress / 6321 40W 30KS 80 1 Regress 2015., LLC. Revised 07/18/2016

Beve 5.0 MAX OUTPUT 5.0 DELIVERED PERFORMANCE / 6321 60W 30KS 40 1 Regress / 6321 60W 30KS 50 1 Regress 2015., LLC. Revised 07/18/2016

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D2 / DIML2 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D3 / DIML3 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF2-10ND-120-100% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD-10NXD- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-100%-1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V- GROUND ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D4 / DIML4 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-100% 1% 1 41 1 20 Lutron Nova T NTF-103P- 100% 1% 1 20 1 10 Lutron Nova NF-10-100% 1% 1 41 1 20 Lutron Nova NF-103P- 100% 1% 1 20 1 10 Lutron Vareo VF-10-100% 1% 1 20 1 10 Lutron Skylark SF-10P-, SF-103P- 100% 1% 1 20 1 10 Lutron Diva DVF-103P-, DVSCF-103P- 100% 1% 1 20 1 10 Lutron Ariadni AYF-103P- 100% 1% 1 20 1 10 Lutron Vierti VTF-6A- 100% 1% 1 15 1 7 Lutron Maestro MAF-6AM-, MSCF-6AM- 100% 1% 1 15 1 7 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 15 1 7 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 15 1 7 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 15 1 7 Lutron Interfaces PHPM-3F-120, PHPM-3F-DV 100% 1% 1 41 1 20 Lutron GP Dimming Panels Various 100% 1% 1 41 1 20 277V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-277- 100% 1% 1 44 1 22 Lutron Nova T NTF-103P-277-100% 1% 1 33 1 16 Lutron Nova NF-10-277- 100% 1% 1 44 1 22 Lutron Nova NF-103P-277-100% 1% 1 33 1 16 Lutron Skylark SF-12P-277-, SF-12P-277-3 100% 1% 1 33 1 16 Lutron Diva DVF-103P-277-, DVSCF-103P-277-100% 1% 1 33 1 16 Lutron Ariadni AYF-103P-277-100% 1% 1 44 1 22 Lutron Vierti VTF-6A- 100% 1% 1 33 1 16 Lutron Maestro MAF-6AM-277-, MSCF-6AM-277-100% 1% 1 20 1 10 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 33 1 16 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 33 1 16 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 33 1 16 Lutron Interfaces PHPM-3F-DV 100% 1% 1 88 1 44 Lutron GP Dimming Panels Various 100% 1% 1 88 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D4 / DIML4 Continued NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) GROUND DIMMER: 3 WIRE PHASE DIMMED HOT SWITCHED HOT D4 / DIML4 3 WIRE PHASE DIMMING CAP UNUSED ECOSYS WIRES PURPLE GRAY PURPLE ORANGE V- D4 / DIML4 : Lutron Hi-Lume A-Series Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. E2 E1 D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 WALL CONTROL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE V- 2016., LLC. I2-264-4 Revised 03/22/2017

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIMMING COMPATIBILITY SELECTION GUIDE D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V DIMMING (NO RELAY) CLASS 2 CONTROL WIRES DIMMER: 0-10V RELAY 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- GROUND DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- DIMMER: 0-10V w/ POWER SWITCHING DIML6A, 6B 0-10V DIMMING (NO RELAY) 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D7 / DIML7 and D7E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) V- 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D8 / DIML8 and D8E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D8 / DIML8 and D8E Dimming Driver Wiring D8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = Eldo POWERdrive DMX control dims from 100% to 0.1% D8E = Eldo POWERdrive DMX control dims from 100% to 1% DMX BUS - XLR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. D8 / DIML8 / D8E DMX CONTROLS DMX BUS - XLR CABLE OR SHIELDED DATA CABLE SHIELD DMX (-) DMX (+) 5 PIN XLR JACKS STANDARD 8 BIT DMX 512 CONTROLLER RED BARE V- 2016., LLC. I2-264-8 Revised 08/14/2017