DC/DC Converter. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden

Similar documents
Power Supply, Built-In DC/DC. XP POWER L L C SUITE E DYER RD SANTA ANA, CA United States

EU Declaration of Conformity

Component Switching Power Supply. XP POWER L L C Suite E DYER RD Santa Ana, CA USA

Laptop Computer (OLPC)

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

Certificate of Compliance

CERTIFICATE. No. P Order No Page 1/2

CB TEST CERTIFICATE. Personal Computer. Acer Computer (Shanghai) Limited 3F, No. 168 Xizang Medium Road Huangpu District, Shanghai CHINA

File E Vol. 1 Sec. 93 Page 1 Issued: and Report Revised:

Certificate of Compliance

Independent controlgears

Certificate of Compliance

EU Declaration of Conformity

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

EU Declaration of Conformity

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Power Supply for building-in TH-10280, THAILAND. See page 2. 0 Additional Information on page 2

DIN Rail Power Supply. Refer to page 2. [8] Additional Information on page 2. Input: Vac; 12 A; 50-60Hz Output: 24 V de; 40 A

Test Report issued under the responsibility of:

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Amendment to Test Report

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

CERTIFICATE. No. P Order No Page 1/2

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

File E Project 97SC January 21, 1998 REPORT

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Test Report issued under the responsibility of:

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU750P701U1U; OLU750P701U1A

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

Installation and converting instructions to another gas type T4530, T4650

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

This is a preview - click here to buy the full publication COMMISSION ELECTROTECHNIQUE INTERNATIONALE INTERNATIONAL ELECTROTECHNICAL COMMISSION

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Consumer Products Services Germany GmbH Türkheim Germany

ENEC NO2187. Nemko hereby grants the following manufacturer as licensee the right to affix this ENEC mark on the product(s) specified below.

Provläsningsexemplar / Preview TECHNICAL REPORT

IECEE OPERATIONAL DOCUMENT

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Declaration of Conformity

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Test Report Iec En Household And Similar

UL TEST REPORT AND PROCEDURE

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU700P142U1A; OLU700P142U1U

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Datasheet - AZM 161SK-12/12RK-024

AS/NZS :2016

COVER PAGE FOR TEST REPORT

1 BUSINESS ENVIRONMENT OF THE CEN/TC

This document is a preview generated by EVS

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

English version. Central Secretariat: rue de Stassart 35, B Brussels

Illuminated Stopper Station Push Button

AS/NZS IEC :2013

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/52

This document is a preview generated by EVS

GETINGE CLEAN SINK DOSING (CSD)

INTERNATIONAL STANDARD

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

This document is a preview generated by EVS

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

SOUTH AFRICAN NATIONAL STANDARD

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. August 2015

Certificate of Compliance

ISO/TS TECHNICAL SPECIFICATION

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Record of Amendments. Version Date Amendment Section/page affected

INTERNATIONAL STANDARD

No. KM First Issued: 23/03/1998 Latest Issue: 11/08/2010 Page 5 of 9

Datasheet - AZM 161SK-12/12RK-024

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. July 2017

What does doesn t a power supply have to comply with these days!

Emotron M10 Shaft Power Monitor. Instruction manual English

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

WIO200 Water in oil sensor

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

AUGUST 2016 CONTENTS:

Global Conformity Assessment of Photovoltaic systems

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

TEST REPORT IEC60529 Edition TD990426C02

Transcription:

Ref. Certif. No. DK-29983-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2 ème page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) CERTIFICAT D'ESSAI OC DC/DC Converter ERICSSON AB FAROGATAN 6 STOCKHOLM, SE-164 80 Sweden ERICSSON AB FAROGATAN 6 STOCKHOLM, SE-164 80 Sweden SHANGHAI ERICSSON ELECTRONICS CO LTD 33 FUHUA RD JIADING DISTRICT SHANGHAI, 201818. China Additional Information on page 2 See Page 2 Ericsson Type of Manufacturer's Testing Laboratories used Type de programme du laboratoire d'essais constructeur Model / Type Ref. Ref. De type PKD 4118 SIOD, PKD 4118 SIODN, PKD 4210 SI, PKD 4218 SI, PKD 4218 SIN, PKD 4218 SIOA, See Page 2 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2 ème page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d'essais numéro de référence qui constitue partie de ce Certificat Additional Information on page 2 IEC 60950-1(ed.2), IEC 60950-1(ed.2);am1 E210157-A8-CB-3 issued on 2012-12-24 This CB Test Certificate is issued by the National Certification Body Ce Certificat d'essai OC est établi par l'organisme National de Certification Date: 2012-12-24 Signature: UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Jan-Erik Storgaard rd 1/2

Ref. Certif. No. DK-29983-UL Model Details: PKD 4118 SIOD,PKD 4118 SIODN,PKD 4210 SI,PKD 4218 SI,PKD 4218 SIN,PKD 4218 SIOA,PKD 4218 SIOAN,PKD 4218HE SI,PKD 4218L ASI,PKD 4218LE SI,PKD 4218N ASI,PKD 4319 SI,PKD 4319 SIN,PKD 4510 ASI,PKD 4510E SI,PKD 4511 ASI,PKD 4210 SIN,PKD 4311 SI,PKD 4311 SIN,PKD 4318G ASI,PKD 4318H ASI,PKD 4319 ASI where "SI" suffix for PKD-E series could be replaced by "SRI" or "SPBI" Ratings: Input: All models 36-75Vdc Output: 1. 3.3Vdc/26W, 2. 5.0Vdc/30W, 3. 1.5Vdc, 30W, 4. 1.8Vdc/36W, 5. 2.5Vdc/38W, 6. 2.5Vdc/30W, 7. 1.0Vdc/20W, 8. 1.2Vdc/24W, 9. 1.8Vdc/25W, 10. 1.5Vdc/21W, 11. 1.2Vdc/17W, 12. 3.3Vdc/50W, 13. 5Vdc/50W, 14. 1.2Vdc/24W, 15. 1.5Vdc/21W, 16. 3.3Vdc/50W No ratings are required on the product Additional Information: Model/Type reference: 1. PKD 4210 SI or SIN, 2. PKD 4311 SI or SIN, 3. PKD 4318H ASI, 4. PKD 4318G ASI, 5. PKD 4319 ASI, 6. PKD 4319 SI or SIN, 7. PKD 4218N ASI, 8. PKD 4218L ASI, 9. PKD 4218 SI or SIN, 10. PKD 4218 SIOA or SIOAN, 11. PKD 4118 SIOD or SIODN, 12. PKD 4510 ASI, 13. PKD 4511 ASI, 14. PKD 4218LE SI, 15. PKD 4218HE SI, 16. PKD 4510E SI Additionally evaluated to EN 60950-1:2006/A11:2009/A1:2010/A12:2011; National Differences specified in the CB Test Report. Additional information (if necessary) Information complémentaire (si nécessaire) UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Date: 2012-12-24 Signature: Jan-Erik Storgaard 2/2

Issue Date: 2012-12-24 Page 1 of 54 Report Reference # E210157-A8-CB-3 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements E210157-A8-CB-3 Date of issue... : 2012-12-24 Total number of pages... : 54 CB Testing Laboratory... : Address... : Applicant's name... : Address... : Test specification: UL International Polska Sp. z o.o. Aleja Krakowska 81, 05-090 Sekocin Nowy, Poland ERICSSON AB FAROGATAN 6 SE-164 80 STOCKHOLM SWEDEN Standard... : IEC 60950-1:2005 (2nd Edition); Am 1:2009 Test procedure... : Non-standard test method... : Test Report Form No.... : Test Report Form originator... : CB Scheme N/A IEC60950_1B SGS Fimko Ltd Master TRF... : 2010-04 Copyright 2010 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this test Report is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Issue Date: 2012-12-24 Page 2 of 54 Report Reference # E210157-A8-CB-3 Test item description... : Trade Mark... : DC/DC Converter Ericsson Manufacturer... : Model/Type reference... : Ratings... : ERICSSON AB FAROGATAN 6 SE-164 80 STOCKHOLM SWEDEN 1. PKD 4210 SI or SIN, 2. PKD 4311 SI or SIN, 3. PKD 4318H ASI, 4. PKD 4318G ASI, 5. PKD 4319 ASI, 6. PKD 4319 SI or SIN, 7. PKD 4218N ASI, 8. PKD 4218L ASI, 9. PKD 4218 SI or SIN, 10. PKD 4218 SIOA or SIOAN, 11. PKD 4118 SIOD or SIODN, 12. PKD 4510 ASI, 13. PKD 4511 ASI, 14. PKD 4218LE SI, 15. PKD 4218HE SI, 16. PKD 4510E SI, where "SI" suffix for PKD-E series could be replaced by "SRI" or "SPBI", Input: All models 36-75Vdc Output: 1. 3.3Vdc/26W, 2. 5.0Vdc/30W, 3. 1.5Vdc, 30W, 4. 1.8Vdc/36W, 5. 2.5Vdc/38W, 6. 2.5Vdc/30W, 7. 1.0Vdc/20W, 8. 1.2Vdc/24W, 9. 1.8Vdc/25W, 10. 1.5Vdc/21W, 11. 1.2Vdc/17W, 12. 3.3Vdc/50W, 13. 5Vdc/50W, 14. 1.2Vdc/24W, 15. 1.5Vdc/21W, 16. 3.3Vdc/50W No ratings are required on the product

Issue Date: 2012-12-24 Page 3 of 54 Report Reference # E210157-A8-CB-3 Testing procedure and testing location: [x] CB Testing Laboratory Testing location / address... : UL International Polska Sp. z o.o. Aleja Krakowska 81, 05-090 Sekocin Nowy, Poland [ ] Associated CB Test Laboratory Testing location / address... : Tested by (name + signature)... : Hubert Koszewski Approved by (name + signature)... : Michal Siudowski [ ] Testing Procedure: TMP Tested by (name + signature)... : Approved by (+ signature)... : Testing location / address... : [ ] Testing Procedure: WMT Tested by (name + signature)... : Witnessed by (+ signature)... : Approved by (+ signature)... : Testing location / address... : [ ] Testing Procedure: SMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : Testing location / address... : [ ] Testing Procedure: RMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : Testing location / address... : List of Attachments National Differences (41 pages) Enclosures (17 pages) Summary of Testing: All Applicable tests according to the referenced standard(s) have been carried out Summary of Compliance with National Differences: Countries outside the CB Scheme membership may also accept this report. List of countries addressed: AT, BE, BG, BY, CA, CH, CZ, DE, DK, ES, EU, FI, FR, GB, GR, HU, IE, IL, IT, JP, KR, NL, NO, PL, PT, RO, SE, SG, SI, SK, UA, US

Issue Date: 2012-12-24 Page 4 of 54 Report Reference # E210157-A8-CB-3 The product fulfills the requirements of: EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011

Issue Date: 2012-12-24 Page 5 of 54 Report Reference # E210157-A8-CB-3 Copy of Marking Plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.

Issue Date: 2012-12-24 Page 6 of 54 Report Reference # E210157-A8-CB-3 Test item particulars : Equipment mobility...: Connection to the mains...: Operating condition...: Access location...: Over voltage category (OVC)...: Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: IT testing, phase-phase voltage (V)...: - Class of equipment...: Considered current rating of protective device as part of the building installation (A)...: for building-in No direct connection to mains continuous No operator access permitted. Intended for building -in OVC II N/A Pollution degree (PD)...: PD 2 IP protection class...: No Special Application to be determined in end product IP X0 Altitude of operation (m)...: 2000 Altitude of test laboratory (m)...: 130 Mass of equipment (kg)...: <0.5 Possible test case verdicts: - test case does not apply to the test object... : N / A - test object does meet the requirement... : P(Pass) - test object does not meet the requirement... : F(Fail) Testing: Date(s) of receipt of test item...: 2007-06-25 Date(s) of Performance of tests...: 2010-11-22 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. Manufacturer's Declaration per Sub Clause 6.25 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory and a declaration form the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... Not Applicable When differences exist, they shall be identified in the General Product Information section. Name and address of Factory(ies): SHANGHAI ERICSSON ELECTRONICS CO LTD 33 FUHUA RD JIADING DISTRICT

Issue Date: 2012-12-24 Page 7 of 54 Report Reference # E210157-A8-CB-3 SHANGHAI 201818 CHINA GENERAL PRODUCT INFORMATION: Report Summary All applicable tests according to the referenced standard(s) have been carried out. Product Description USR/CNR The products covered by this report are dc-to-dc converter switch mode power supplies, Models PKD 4xxx. May be followed by suffix ASI, SI, SIN, SIOA, SIOAN, SIOD or SIODN. They are provided with terminal pins for connection to their nominal rated dc source of supply and output connections. Model Differences ASI = Surface-mount, Insulated, Selectable Negative or Positive remote control logic. SI = Surface-mount, Insulated, Positive remote control. SIN = Surface-mount, Insulated, Negative remote control. SIOA = Surface-mount, Insulated, Optional output 1.5V (A), Positive remote control. SIOAN = Surface-mount, Insulated, Optional output 1.5V (A), Negative remote control. SIOD = Surface-mount, Insulated, Optional output 1.2V (D), Positive remote control. SIODN = Surface-mount, Insulated, Optional output 1.2V (D), Negative remote control. L and H = different output voltages (1.2V and 1.5V), E = the new series (PKD-E) The only difference between an old PKD series and a new PKD-E series schematic diagram is the component numbers and the layout. PKD-E series and the PKD series have the same electrical rating and foot print, the difference is mechanical: PKD is build on a ceramic board with all components on the pin side and a lead frame welded on top, PKD-E is build on a fiber glass board with all components on the top side and it has no pins. For PKD-E models suffix SI indicates surface-mount, Insulated, Selectable Negative or Positive remote control logic and SRI suffix indicates the same suited for leaded soldering, suffix SPBI indicates use of solder paste with lead (Pb). Additional Information The label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it shall not be affixed to products prior to such an approval. E210157-A8-CB-3-Reissue (12CA68488) This report is a reissue of CBTR Ref. No.: E210157-A8-CB-2, CB Test Certificate Ref. No. DK-21050 due to standard upgrade to IEC 60950-1 2 Edition + Amenmend 1 and EN 60950-1:2006 +A1:2010 +A11:2009 +A12:2011. Based on the previously conducted testing and the review of product technical documentation including photos, schematics, wiring diagrams and similar, has been determined that the product continues to comply with the standard No tests conducted under this investigation due to reissue of CB Test Report Ref. No. E210157-A8-CB-2. All required tests were carried out under the original investigation

Issue Date: 2012-12-24 Page 8 of 54 Report Reference # E210157-A8-CB-3 This test report should be read in conjunction with the original report number: - E210157-A8-CB-1 issued 2005-05-09 with CB Cert. No. DK-8744 issued 2005-05-18. - E210157-A8-CB-1 with Amendment 1 issued 2007-09-26 with CB Cert. No. DK-8744-A1 issued 2007-10- 01. Testing was not considered necessary based on review of schematics, construction and component specifications. This report has been re-issued, due to: - The standard has been upgraded to IEC 60950-1 2nd Edition. - CBTL has been changed from UL Demko to UL Poland. - Applicant & Manufacture changed from ERICSSON POWER MODULES AB / LM ERICSSONS VAG 30, SE-126 25 STOCKHOLM SWEDEN to ERICSSON AB / ISAFJORDSGATAN 16B, STOCKHOLM SE-164 80, SWEDEN - List of factories has been updated. Factory name changed from SHANGHAI ERICSSON SIMTEK ELECTRONICS CO LTD to SHANGHAI ERICSSON ELECTRONICS CO LTD. Factory location 'PROXY ELECTRONICS AB' has been deleted. Technical Considerations The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 (which includes all European national differences, including those specified in this test report). The transformer in the converter is not relied on for providing any insulation. It provides Functional insulation only. -- Output voltages remain within SELV limits, even with internally generated non-selv voltages. This was demonstrated by performing Abnormal Tests including single component failure and functional insulation bypass with various grounding conditions, and with the input and output floating. In all cases the output voltage did not exceed SELV. -- All models are evaluated and tested for use at altitude up to 5 000 m based on consideration that FUNCTIONAL INSULATION is employed in te product and tested by method 5.3.4 c). -- The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: Maximum Case Temperature of 90 C -- Engineering Conditions of Acceptability When installed in an end-product, consideration must be given to the following: These components have been evaluated for FUNCTIONAL INSULATION only between input-output. -- When the DC-DC converter is supplied by ELV and SELV respectively, the following is considered: a) when the input comply with ELV the output of the DC/DC converter may be considered ELV; b) when the input comply with SELV, the output of the DC/DC converter remains at SELV under normal and abnormal operation condition. -- For cases when the supply voltage is higher than 60Vdc up to and including 75Vdc the following must be adhered: The input source to the DC/DC Converter must:, a) Be separated from primary circuit by DOUBLE/REINFORCED INSULATION (SELV or TNV-2 circuit), or, b) Be separated from primary circuit and earth by minimum BASIC INSULATION and the SELV circuits reliably connected to main earth terminal. -- Output voltages remain within SELV limits, even if the input supply voltage is up to 75Vdc and considering the source is centralized d.c. power system (DC mains voltage) treated as TNV-2 circuit

Issue Date: 2012-12-24 Page 9 of 54 Report Reference # E210157-A8-CB-3 (> 60 Vdc up to and including 80 Vdc). This has been confirmed by evaluation per sub-clause 2.2.4, sub-clause 2.3.2 and 5.3.4 and demonstrated by e.g. fault condition testing, where the functional insulation barriers have been short circuited and by electric strength test conducted across insulation. -- The power supply shall be installed in compliance with the enclosure, mounting, spacing, casualty, and segregation requirement of the ultimate application. -- The following secondary output circuits are at non-hazardous energy levels: All Outputs -- The power supply terminals and/or connectors are: Suitable for factory wiring only -- The maximum investigated branch circuit rating is: 15 A external fuse was used during the tests. -- The investigated Pollution Degree is: 2 -- The following end-product enclosures are required: Mechanical, Fire -- The following components require special consideration during end-product Thermal (Heating) tests due to the indicated maximum temperature measurements during component-level testing: Transformer M1(99.2 C) -- The end-product Electric Strength Test is to be based upon a maximum working voltage of: 101.9V peak, 42.2Vrms -- The DC/DC converter shall be protected by a 15 A time lag fuse in end-product. -- Models PKD series listed in this report were tested to confirm that under normal and single fault conditions the output operates within SELV limits (in accordance with sc 2.2.4.) When these converters are supplied by an ELV circuit AND the output is connected to main protective earthing, the functional insulation provided in the DC-DC converter is sufficient insulation. -- The following Production-Line tests are conducted for this product: Electric Strength for models with base plate. -- The following secondary output circuits are SELV: All outputs -- Abbreviations used in the report: - normal condition... N.C. - single fault condition...s.f.c - operational insulation... OP - basic insulation...bi - basic insulation between parts of opposite - supplementary insulation...si polarity: BOP - double insulation... DI - reinforced insulation...ri Indicate used abbreviations (if any)