VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

Similar documents
AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

ELFOEnergy Extended Inverter

ELFOEnergy Duct Inverter

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

ELFOEnergy Extended Inverter

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

VERTICAL WATER RECESSED TERMINAL UNIT

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LZA High efficiency air to water heat pumps with HP compressor

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air-to-water scroll chillers

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

ELFOEnergy Edge. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XMi RANGE HIGH SEASONAL EFFICIENCY

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP

CRIMSON & CRIMSON MAX

LZT High efficiency air to water heat pumps with E.V.I. compressors

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

ELFOEnergy Magnum - Heat pump

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Water chillers water/water type SIGMA Technical information manual

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ELFOSPACE BOX "CASSETTE" TYPE TERMINAL UNIT

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

Advance Split

HT V2 HT Split

WZH Ground source heat pumps

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

Blue Box Epsilon Echos +

30RH B Nominal cooling capacity kw Nominal heating capacity kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

AWR MTD2 XE. Versions

HYDRONIC RESIDENTIAL

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

High temperature air-to-water heat pumps

ELFOEnergy Ground Medium 2 - Multifunction

Air Cooled Chillers & Heat Pumps WinPACK HE-A

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PRODUCT GUIDE

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

TCHE-THHE TCEE

AQUASNAP JUNIOR 30RHV

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Neosys Product catalogue

Transcription:

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Operation only in heating Operation up to -18 C Reduced energy consumption Water production from 60 C to -10 C external air *Due to its high efficiency, "Vulcan'" may be eligible for heat pump subsidies in Your Country. Please contact Your tax office or utility. WBAN (R-407C) Size Heating [kw] 41 14,9 61 19,3 81 26,3 REPLACE: BT05I016GB-09 The heating of the future respects the environment. The VULCAN heat pump series represent an important stage in the development of this type of unit. They feature the most up-to-date advances in technology, standing out for: EFFICIENCY thanks to its special construction, the WBAN series ensures high energy efficiency also in extreme working conditions; SELF-ADAPTING the evolved electronics implemented adapt the operating parameters of the chiller to the load conditions of the system it is installed in, optimising consumption, noise and the working life of the components; EASE OF INSTALLATION each unit is supplied as standard with a complete hydronic assembly and is completely tested in the factory; installation is consequently quick and easy. CERTIFIED QUALITY SYSTEM UNI EN ISO 9001:2008 According to the UNI EN 14511:2008

PERFECT FOR RESIDENTIAL EUROVENT ENERGY EFFICIENCY CLASSIFICATON CLASS A IN HEATING MODE PERFECT FOR HEATING AND UNDERFLOOR HEATING Thanks to its characteristics the unit can be used both in traditional systems with TERMINAL UNITS and in systems with EMBEDDED UNDERFLOOR PIPING with higher efficiency than traditional units. TOP NOISELESSNESS FOR A SUPERIOR COMFORT EUROVENT ENERGY EFFICIENCY CLASSES WATER: 30/35 C AIR 7 C D.B. / 6 C W.B. Noise is one of the most critical factors of this type of unit. The application of special regulation logic enables to adapt the fan operating speed to the system load and to the external air temperature. In this way you can optimize the energy efficiency and guarantee the lowest possible noise level, especially during evening and night hours, when the air temperature is lower and sensitivity to noise is greater. WATER FILTER - SUPPLIED AS STANDARD (external installation) Steel mesh mechanical filter positioned at the exchanger inlet. Suitable for filtering water and trapping the impurities present in the water circuit. ICE PROTECTION SYSTEM A special measure in the refrigerating circuit prevents ice from forming in the base of the air exchanger. STANDARD-SUPPLIED USER KEYPAD The remote keyboard allows unit start and stop, Summer/Winter setting, 2 selections of ambient temperature, one of "COMFORT" temperature where the set point is visualized only on board, an other of "ECO" temperature that decreases in winter mode and increases in summer mode the set point and the hidric /cooling/electric circuit alarm signal. The connection is done with a shielded cable 3 x 0.34mm2 max 100m which is connected with the unit. Thanks to its pleasant aspect it can be installed in ambient. Electric - refrigerating - water alarm signals Check comfort-economic-test control SUMMER-WINTER-OFF signals SUMMER-WINTER-OFF control 2

STANDARD UNIT SPECIFICATIONS COMPRESSOR Hermetic orbiting scroll compressor complete with motor over-temperature and over-current devices and protection against excessive gas discharge temperature. Fitted on rubber antivibration mounts and complete with oil charge. A oil heater is automatically switched on at the compressor shut-down to prevent oil dilution by the refrigerant. STRUCTURE Structure made from "aluzink" plate, providing excellent mechanical characteristics and extensive corrosion strength PANELLING External panels in prepainted aluminium especially indicated in outdoor installation due to its superior resistance to corrosion avoiding periodic painting. Side panels are easily removable and allow complete access to unit components. Internal sound proof lining reduces sound pressure levels. INTERNAL EXCHANGER Direct expansion heat exchanger, braze-welded AISI 316 stainless steel plates with large exchange surface and complete with external heat and anti-condensate insulation. The exchanger comes complete with: - antifreeze heater to protect the water side exchanger, preventing the formation of frost if the water temperature falls below a set value. EXTERNAL EXCHANGER Heat exchange coil with aluminium fins and copper tubes in staggered rows. The coils are complete with integral subcooling circuit which assures the correct refrigerant feeding of the expansion valve. Available in different options as per optional list. The unit is fitted as standard with coil protection grills. FAN Propeller fans with aluminium pressure die-cast blades, directly driven by single-phase external rotor electric motor complying with VDE 0530/12.84, complete with thermal protection, IP 54 class according to DIN 40 050 norm. The impellers are housed in aerodynamically shaped nozzles to increase the efficiency and minimize the sound level, and protected by fan guards. REFRIGERANT CIRCUIT The circuit is complete with: - filter dryer - expansion device - high pressure switch - low pressure switch - liquid receiver - 4-way reverse cycle valve - Ice Protection System: system to prevent ice on the bottom of air coil TRAY Thermoformed ABS condensate collection tray fitted with drain pipe. ELECTRICAL PANEL The Power Section includes: - compressor and fan fuses only on unit 230/1/50 - compressor circuit breaker only on unit 400/3/50 - compressor control contactor - main door lock isolator switch - In sizes 41 230/1/50, the soft starter is included standard. The control section includes: - microprocessor control - variable fan speed control for operation at low ambient temperatures - automatic defrost control - set point compensation with outside temperature probe - set point compensation with 4-20 ma signal - high refrigerant gas pressure pre-alarm function that in many cases prevents the unit from being shut-down - compressor overload protection and timer - relay for remote cumulative fault signal - management of electrical heating elements - double temperature management - domestic water valve control - electronic for Elfo Control system (optional) REMOTE KEYPAD FOR USER remotable control keypad, including: - SLEEP button for optimised night-time operation - ON/OFF and alarm reset buttons - signal led electric circuit alarm - signal led refrigerant circuit alarm - hydraulic circuit alarm signal led The remote keypad connection for user to the unit is set using a 3 x 0.34 mm 2 screened cable. Maximum distance 100m. HYDRAULIC CIRCUIT - stainless steel mesh mechanical filter. - centrifugal pump - diaphragm expansion vessel - water side safety valve - water fill assembly with pressure gauge - drain valve - differential pressure switch, water side ACCESSORIES SYSTEM ACCESSORIES - 00 litres hydraulic breaker - hose kit for connection to chiller/heat pump. With connections of 1" - hose kit for connection to chiller/heat pump. With connections of 1 1/4" - radiant panels management kit with 1" connections - Kit for management of radiant panels with connections of 1 1/4" - 500 litres domestic hot water kit - boiler control kit - electronic wall-mounting room thermostat ACCESSORIES SEPARATELY PROVIDED: - rubber antivibration mounts - domestic hot water kit control - serial communication module to supervisor (MODBUS) - phase monitor - local control portable keypad with cable 1,5 metres CONFIGURATION CODE ( 1 ) ( 2 ) ( 3 ) ( 4 ) ( 5 ) ( 6 ) WBAN 41 400TN CCS - HYGU - - (1) VOLTAGE Supply voltage 400/3/50+N(400TN) 400TN = 400/3/50+N Supply voltage 230/1/50(230M) only size 41 (2) ENERGY EFFICIENCY High Energy efficiency 41 400TN CCS (Standard) - (Standard) HY GU (St andard) - (Standard) - (Standard) 61 230M CCCA EH246-3WV SFSTR4N 81 CCCA1 CCCC (3) CONDENSING COIL Standard condenser coil (CCS) standard Copper / aluminium condenser coil with acrylic lining (CCCA) Copper / aluminium condenser coil with Fin Guard treatment (Silver) (CCCA1) Copper /copper condenser coil (CCCC) (4) AUXILIARY ELECTRIC HEATING ELEMENTS Integration heating elements: not required (-) standard Modular integration electric heater 2-4 and 6kW (EH246) (5) HYDRONIC GROUP UTILITY SIDE Hydronic group utility side (HYGU) standard Hydronic group utility side: not required (-) (6) 3-WAY VALVE Three-way valve: not required(-) standard Three-way valve (3WV) for sanitary hot water (7) SOFT STARTER Disposal for inrush current reduction: not required (-) standard Disposal for inrush current reduction, for unit 400/3/50+N(SFSTR4N) Disposal for inrush current reduction, for unit 400/3/50+N In sizes 41, 230/1/50, the soft starter is included standard. 3

GENERAL TECHNICAL SPECIFICATIONS Size 41 61 81 HEATING Heat output (40/45 C _ 7 C D.B. / 6 C W.B.) 1 kw 14,9 19,3 26,0 Compressor power input (40/45 C - 7 C D.B. / 6 C W.B.) 1 kw 3,99 5,37 7,27 Total power input 2 kw 4,51 5,82 8.27 COP(Eurovent 40/45 C_ 7 C D.B. / 6 C W.B.) 1 3,45 3,39 3,32 COP (UNI EN 14511:2008; 30/35 C _7 C D.B. / 6 C W.B.) HIGH EFFICIENCY 3 4,10 4,14 4,10 COMPRESSOR Type of compressors SCROLL SCROLL SCROLL No. of Compressors Nr 1 1 1 Std Capacity control steps Nr 1 1 1 Oil charge (C1) l 1,4 1,7 4 Refrigerant charge (C1) kg 4 4,2 5,5 Refrigerant circuits Nr 1 1 1 INTERNAL EXCHANGER Type of internal exchanger 4 PHE PHE PHE No. of internal exchangers Nr 1 1 1 Water flow rate (Internal Exchanger) 1 l/s 0,71 0,92 1,21 Useful pump discharge head 1 kpa 24 50 83 Water content l 2 2,2 2,7 EXTERNAL SECTION FANS Type of fans 5 AX AX AX Number of fans Nr 2 2 4 Standard air flow l/s 1780 1780 2500 Installed unit power kw 0,16 0,16 0,16 CONNECTIONS Water fittings 1"GAS F 1"GAS F 1"GAS F HYDRAULIC CIRCUIT Max water side pressure kpa 550 550 550 Safety valve calibration kpa 600 600 600 EXPANSION VESSEL Expansion vessel capacity l 5 5 5 Maximum water side pressure kpa 600 600 600 Nitrogen buffer pressure kpa 150 150 150 No. of expansion vessels Nr 1 1 1 POWER SUPPLY Standard power supply V 230/1/50 400/3/50+N 400/3/50+N NOISE LEVELS Sound pressure level (1 m) db(a) 58 60 64 DIMENSIONS Length mm 1120 1120 1526 Depth mm 524 524 557 Height mm 1176 1176 1224 Packing volume m3 0,9 0,9 1,4 STANDARD UNIT WEIGHTS Shipping weight kg 153 160 270 Operating weight kg 150 157 266 Shown data are referred to units working in perfect installation and exchangers' cleaning conditions. (1) Data referred to the following conditions : - outlet water internal exchanger 45 C - outdoor air temperature 7 C DB - 6 C WB DT=difference between inlet/outlet water temperature = 5 C (2) Total input is obtained from compressor input + fan input (3) The indicated COP values were calculated in compliance with the provisions of standard EN 14511-1:2008. (4) PHE = plates (5) AX = axial-flow fan (6) The size 41 is available with supply voltage 400/3/50 + N 4

OPERATING LIMITS (HEATING) EXTERNAL EXCHANGER Max air temperature inlet (WB) 1 C 40 40 40 Min air inlet temperature (W.B.) 2 C -18-17 -17 INTERNAL EXCHANGER Min. water outlet temperature 3 C 20 20 20 Max water outlet temperature 4 C 60 60 60 Water thermal head (min / max) C 3 / 8 3 / 8 3 / 8 ATTENTION: IN CASE OF PREDOMINANT WINDS, WINDBREAK BARRIERS ARE NECESSARY. Shown datas are referred to units working in perfect installation and exchangers' cleaning conditions. (1) water to internal exchanger 41/46 C summer operation, with fan speed control device (2) water to internal exchanger */55 C (3) outdoor air temperature 7 C DB - 6 C WB (4) Outdoor air temperature: -10 C D.B./ -10.5 C W.B. 65 60 55 50 Tw [ C] = HEAT EXCHANGER OUTLET WATER TEMPERATURE Ta = OUTSIDE AIR TEMPERATURE ( C) W.B. (1) THE SHADED AREA SHOWS OPERATION WITH AIR FLOW RATE IN MODULATION Tw ( C) 45 40 35 30 ( 1 ) 25 20 15-20 -15-10 -5 0 5 10 15 20 25 30 35 40 45 Ta ( C) ELECTRICAL DATA VOLTAGE: 230/1/50 Size 41 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Circulator A 1,2 F.L.A. - Total A 30.5 F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Circulator kw 0,3 F.L.I. - Total kw 6.2 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A 45 Power supply 230/1/50 Hz +/-6% Voltage unbalance: max 2 % The circulator is included in the total values calculation The units are compliant with the provisions of European standards CEI EN 60204 and CEI EN 60335. In case of abnormal conditions, the device does not limit the current, providing the torque necessary at the compressor starting.. ELECTRICAL DATA VOLTAGE: 400/3/50+N Size 41 61 81 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Circulator A 1,2 2,1 3,2 F.L.A. - Total A 10,5 15,8 22,9 F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Circulator kw 0,3 0,4 0,7 F.L.I. - Total kw 5,3 7,5 11,1 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A 66,5 104,4 104,8 Power supply 400/3/50 (+ NEUTRAL) +/- 6% Maximum Phase Unbalance: 2% The circulator is included in the total values calculation For non standard voltage please contact Clivet technical office The units are compliant with the provisions of European standards CEI EN 60204 and CEI EN 60335. 5

CORRECTION FACTOR FOR ANTIFREEZE SOLUTIONS % ethylene glycol by weight 5% 10% 15% 20% 25% 30% 35% 40% Freezing temperature C -2,0-3,9-6,5-8,9-11,8-15,6-19,0-23,4 Safety temperature C 3,0 1,0-1,0-4,0-6,0-10,0-14,0-19,0 Cooling Capacity Factor Nr 0,995 0,990 0,985 0,981 0,977 0,974 0,971 0,968 Compressor input Factor Nr 0,997 0,993 0,990 0,988 0,986 0,984 0,982 0,981 Internal exchanger Glycol solution flow Factor Nr 1,003 1,010 1,020 1,033 1,050 1,072 1,095 1,124 Pressure drop Factor Nr 1,029 1,060 1,090 1,118 1,149 1,182 1,211 1,243 The correction factors shown refer to water and glycol ethylene mixes used to prevent the formation of frost on the exchangers in the water circuit during inactivity in winter. FOULING CORRECTION FACTOR INTERNAL EXCHANGER m² C/W F1 FK1 0.44 x 10^(-4) 1,00 1,00 0.88 x 10^(-4) 0,97 0,99 1.76 x 10^(-4) 0,94 0,98 F1 = Heat power correction factor FK1 = Compressor power input correction factor PUMP PERFORMANCE Dp DP (kpa) 140 130 120 110 100 90 80 70 60 50 40 30 20 41 10 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) 61 81 CURVE OF DISCHARGE HEAD WITH HYDRONIC ASSEMBLY DP[KPA]=USEFUL DISCHARGE HEAD Q[L/S]= WATER-FLOW RATE THE HEADS ARE INTENDED AS AVAILABLE AT THE UNIT CONNECTIONS EXCHANGER PRESSURE DROPS 90 41 80 70 Dp DP (kpa) 60 50 40 30 20 10 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) Q (l/s) 61 81 DP = PRESSURE DROP Q = WATER FLOW SIZE 41 61 81 Minimal flow [l/s] 0,48 0,64 0,83 Maximum flow [l/s] 0,73 0,92 1,21 6

HEATING PERFORMANCE Size Ta ( C) DB/WB INTERNAL EXCHANGER WATER OUTLET TEMPERATURE ( C) 35 40 45 50 55 60 kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe 41 61 81-15 / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2-15 / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2-15 / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2 7,15 2,83 7,46 3,12 7,76 3,40 8,06 3,68 8,36 3,96 - - 8,94 2,89 9,15 3,20 9,36 3,52 9,57 3,83 9,78 4,14 9,98 4,45 10,0 2,94 10,2 3,27 10,3 3,59 10,5 3,92 10,7 4,24 10,8 4,57 10,7 2,97 10,8 3,31 11,0 3,64 11,1 3,98 11,3 4,31 - - 13,1 3,12 13,2 3,48 13,3 3,84 13,4 4,20 13,5 4,56 - - 14,7 3,24 14,8 3,62 14,9 3,99 15,0 4,37 15,2 4,74 - - 15,7 3,32 15,8 3,70 15,9 4,09 16,1 4,47 - - - - 8,36 3,45 9,63 3,94 10,9 4,44 12,2 4,94 13,4 5,43 - - 11,2 3,60 11,9 4,07 12,6 4,55 13,3 5,02 13,9 5,49 14,6 5,97 12,8 3,70 13,2 4,17 13,7 4,64 14,1 5,11 14,5 5,58 14,9 6,05 13,9 3,77 14,1 4,24 14,4 4,71 14,7 5,19 14,9 5,66 15,2 6,13 17,3 4,03 17,2 4,54 17,2 5,05 17,1 5,57 17,1 6,08 17,1 6,59 19,4 4,23 19,4 4,80 19,3 5,37 19,3 5,94 19,2 6,51 - - 20,7 4,36 20,7 4,97 20,7 5,59 20,7 6,21 - - - - 9,43 4,58 10,6 5,24 11,7 5,91 12,8 6,57 13,9 7,23 - - 14,2 4,77 14,9 5,47 15,5 6,17 16,2 6,87 16,9 7,57 17,6 8,26 16,7 4,89 17,2 5,62 17,7 6,34 18,2 7,07 18,7 7,79 19,1 8,52 18,3 4,97 18,7 5,71 19,1 6,46 19,5 7,20 19,9 7,95 20,2 8,69 23,0 5,25 23,3 6,08 23,5 6,91 23,8 7,74 24,0 8,57 - - 25,6 5,47 25,9 6,37 26,3 7,27 26,7 8,17 27,1 9,07 - - 26,8 5,59 27,3 6,55 27,8 7,50 28,3 8,45 - - - - Ta = External exchanger air intake temperature kwt = Heating capacity (kw) kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C Data listed in the tables are based on plate exchangers without fouling and clean coils. For different situation it is necessary to use adeguate correction factors. INTEGRATED HEATING CAPACITIES Air temperature external exchanger inlet C (D.B. / W.B.) -5 / -5.4 0 / -0.6 OTHERS 5 /3.9 Heating capacity multiplication coefficient 0,89 0.88 1 0.94 To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kwt value in the heating performance tables by the following coefficient. SOUND LEVELS Size Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level 63 125 250 500 1000 2000 4000 8000 db(a) db(a) 41 54 62 67 69 70 66 58 45 58 73 61 55 63 69 71 72 68 59 47 60 75 81 60 68 73 75 76 72 64 51 64 79 Measures according to ISO 3744 regulations, with respect to the EUROVENT 8/1 certification. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Data referred to the following conditions : - unit at full load - outlet water internal exchanger 45 C External air temperature : 7 C D.B./6.0 C W.B. 7

ACCESSORIES Each accessory is marked by a configuration code, e.g. CMMBX. If the last letter is X, it means that the accessory is provided sepaseparately. If the code does not contain the letter X, the accessory is installed at the factory. HEOH - HIGH EFFICIENCY ONLY IN HEATING Option for energy optimization of the units, including the circulating pump use in direct current. This option is available only with the full optional version. WBAN (R-407C) COP 230/1/50 EN14511 14511-1.2008 :2004 COP 400/3/50 EN14511 14511-1.2008 :2004 41 61 81 4,10 - - 4,14 4,14 4,10 The table summarizes the values of COP calculated in accordance with the law UNI EN14511:2008 * Due to its high efficiency, "Vulcan'" may be eligible for heat pump subsidies in Your Country. Please contact Your tax office or utility. AVAILABLE HEAD TO THE SYSTEM [kpa] 100 90 80 70 81 DP (kpa) 60 50 40 30 41 61 20 10 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) Q [L/S] = WATER FLOW RATE DP [KPA] = USEFUL STATIC PRESSURE SYSTEM CIRCULATOR ABSORPTION CURVE Pcirc [kw] 0,28 81 0,27 0,26 0,25 0,24 0,23 0,22 0,21 0,20 0,19 61 0,18 0,17 0,16 0,15 0,14 41 0,13 0,12 0,11 0,10 0,09 0,08 0,07 0,06 0,05 0,04 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 Q [l/s] PCIRC [KPA] = ELECTRIC POWER ABSORBED Q [L/S] = WATER FLOW RATE 8

CCCA - Copper / aluminium condenser coils with acrylic lining The copper/aluminium evaporator coils with acrylic lining can be used in the room where the ambient air contains a concentration of salt and other not very aggressive agents. Configuration Detail CCCA1 - Copper / aluminium condenser coils with Fin Guard (Silver) treatment The Fin Guard Silver, for finned exchanger, is a polyurethane vernish waterproof (for waterworks, see and discharge water). It is also resistant to oil products and other different solvents. It hasn't any effects on the air side pressure drops. Configuration Detail CCCC - Copper / copper condenser coils The copper/copper condensing coil allows a better resistence to the natural agent like salt and sulphureous vapours. Configuration Detail EH246 - Modular integration electric heater 2-4 and 6kW HEATING ELEMENT WATER-SIDE PRESSURE DROP On request the unit can be provided with integration heating elements. Different powers can be selected based on needs. The electrical heating elements are immersed in a small 1-litre tank equipped with a safety thermostat The heating elements are activated by means of an on/off button as a main or additional component based on a temperature threshold, based on parameters defined at first start up. DP (kpa) 33.0 31.0 29.0 27.0 25.0 23.0 21.0 19.0 17.0 15.0 13.0 11.0 9.0 7.0 5.0 3.0 1.0 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q (l/s) Q = WATER FLOW DP = PRESSURE DROP THE PRESSURE DROPS SHOWN IN THE GRAPH ARE TO BE SUBTRACTED, WITH PARITY OF FLOW RATE, FROM THE USEFUL STATIC PRESSURE. IF THE RESULT IS LESS THAN THE PRESSURE DROPS OF THE SYSTEM, IT IS ADVISABLE TO INSTALL AN EXTERNAL PUMP THAT ENSURES THE NECESSARY STATIC PRESSURE. Configuration Detail 9

3WV - Three-way valve Built-in 3-way valve for domestic hot water The unit is provided with a 3-way on/off valve to divert the flow of water to a hot water storage tank. Activation of the 3-way valve takes place by means of closure of a dry contact on the electrical board of the unit. As soon as this function is enabled, the set point of the unit is placed at the value established by the appropriate parameter in the electronic control. Pressure drop three-way valve (1) UNIT ELECTRIC PANEL (2) EXPANSION VESSEL (3) WATER SIDE SAFETY VALVE (4) PUMP (5) THREE-WAY VALVE (6) TERMINAL UNITS (7) UNDERFLOOR HEATING (8) WATERWORKS WATER INLET (9) SANITARY WATER Dp (kpa) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0,5 0,7 0,9 1,1 1,3 1,5 1,7 1,9 2,1 2,3 2,5 2,7 2,9 3,1 Q (l/s) PRESSURE DROP THREE-WAY VALVE Q = WATER FLOW DP = PRESSURE DROP THE PRESSURE DROPS SHOWN IN THE GRAPH ARE TO BE SUBTRACTED, WITH PARITY OF FLOW RATE, FROM THE USEFUL STATIC PRESSURE. IF THE RESULT IS LESS THAN THE PRESSURE DROPS OF THE SYSTEM, IT IS ADVISABLE TO INSTALL AN EXTERNAL PUMP THAT ENSURES THE NECESSARY STATIC PRESSURE. Configuration Detail (-) Unit without hydronic assembly The unit can be requested without circulating pump, expansion vessel, safety valve water side and filling assembly. Configuration Detail PMX - Phase monitor The phase monitor allows to check the right presence of electric supply phases for 400/3/50 units. 10

SFSTR4N - Disposal for inrush current reduction HYDRONIC Disposal for inrush current reduction, for unit 400/3/50+N Starting up a motor directly can overload the electricity network, with start-up currents up to 8 times the nominal current. Thanks to the breakaway current reduction device, start-up takes place gradually, with the start-up current being limited during this period of time. The start-up current can therefore be reduced to 3.5-4 times the nominal current, meaning that the power systems and protection devices can be sized with lower parameters. In sizes 41 230/1/50, the soft starter is included standard. Configuration Detail PBLC1X - Service handset for local control with 1.5-metre cable The service keyboard is necessary for the unit programming and setting. These operations must be done by qualified personnel without compromising the operation of the whole unit. The service keyboard is supplied with a connection cable of 1,5 m lenght. CMMBX - Serial communication module to supervisor (MODBUS) The serial communication module to supervisor (MODBUS) is connected with the principal module through a comb connection (see lay-out on electrical panel). In this way the remote assistance and supervision are available through standard MODBUS protocol. It is possible to connect to a single supervisor system up to 127 units. The connection to PC must be obtained through a converter RS485/232; the serial port RS232 admits as maximum a 10 m length. The serial communication module to supervisor (MODBUS) is necessary when the unit is connected to ELFOCONTROL. AMRX - Rubber antivibration mounts The rubber antivibration mounts reduce the vibrations of compressor during its operation and they are installed at the base toe. 11

SYSTEM ACCESSORIES KTFL1X - Hose kit for connection to chiller/heat pump. With connections of 1" The kit is composed of: Two hoses, length 300 and diameter 1, required for connection of the machine to the system. This kit can be used for heat pumps from 4 to 18kW KTFL2X - Hose kit for connection to chiller/heat pump. With connections of 1 1/4" The kit is composed of: Two hoses, length 300 and diameter 1 ¼, required for connection of the machine to the system. This kit can be used for heat pumps from 19 to 30kW KBQRE5X - 500 litres domestic hot water kit The kit is composed of: - Storage tank in Fe360b and internal vitrification treatment in accordance with DIN 4753.3, external insulation in stiff polyurethane and exchange coil xx m2, maximum operating pressure 6 bar - Electrical heating element 4 kw for possible integration and anti-legionellosis cycle for boiler of 500 litres. - Electronic module for the management of the production of domestic hot water: DHW temperature setting, setting of time period for production of domestic hot water with priority based on a minimum temperature, management of anti-legionellosis cycle, control for three-way valve, management of the electrical heating element. The electronic module dialogues with the heat pump through the serial communication cable. - Three-way deviator valve 1 1/4 and non-return valve 1 1/4 to be installed in the system - Serial connection cable twisted and shielded for networks RS485 AGW22/24 with a length of 15 metres. - Serial communication card CMMBX to be connected in the heat pump Dimensions of boiler of 500 litres: 760 x 1690mm If this accessory is requested, the unit cannot be provided with the three-way valve installed on board. This is because it is to be installed on the system, near the hot water heater. KITERAX - Room thermostat Wall-mounted weekly electronic timer thermostat with summer, winter night adjustment. Range of adjustment +2 C/+35 C. Dimensions 123X88X23 mm. 12

KVMSP1X - Radiant panels management kit with 1" connections KVMSP2X - Kit for management of radiant panels with connections of 1 1/4" (KVMSP1X)The kit is made up of: 1 Mixer valve with three-point modulating actuator. Power box and modulating valve connection Temperature probe to be installed on the outlet of the radiator panels (l=20metres) Thermostat of maximum temperature 55 C Control for circulation pump to the radiator panel This kit may be used with 4-18kW heat pumps (KVMSP2X)The kit is made up of: 1 1/4 Mixer valve with three-point modulating actuator. Power box and modulating valve connection Temperature probe to be installed on the outlet of the radiator panels (l=20metres) Thermostat of maximum temperature 55 C Control for circulation pump to the radiator panel This kit may be used with 19-30kW heat pumps KVICX - Boiler control kit The kit is composed of: -Pair of two way motorized valves for boiler cut-off -Pair of two way motorized valves for heat pump cut-off Valve control electrical junction box KSAX - 100 litres hydraulic breaker Storage tank Fe360b and anti-corrosion treatment with organic enamelling, external insulation with polyurethane and polyethylene mat, thickness 50 mm maximum of operation 6 bar. Diameter 500 Height 900 N 8 connections CACSX - Domestic hot water kit control The module makes it possible to control the temperature of a domestic hot water tank, not provided by Clivet. The adjustment module comes with 2 temperature probes, 1 safety thermostat, power circuit and heating element control with protections against short circuits (the heating element is not provided by Clivet) and the installation box. As opposed to the control of domestic hot water performed directly by the machine electronics, the kit makes it possible to set re-fill time periods and anti-legionella cycles, and to manage a re-circulation pump on the storage tank. The storage tank must be suitably sized based on the combination with the selected heat pump. 13

PLUMBING DIAGRAM Heat pump + radiators + domestic hot water FAN COIL / RADIATORS HEAT PUMP SANITARY WATER PLUMBING DIAGRAM Heat pump + radiators + radiant panels + domestic hot water FAN COIL / RADIATORS HEAT PUMP RADIANT PANELS SANITARY WATER PLUMBING DIAGRAM Heat pump + radiators + radiant panels + domestic hot water + boiler BOILER FAN COIL / RADIATORS HEAT PUMP RADIANT PANELS SANITARY WATER 14

DIMENSIONAL DRAWING HYDRONIC 1120 524 2 12 7 5 10 2 3 12 8 5 1176 13 6 357 14 11 11 80 1 157 107 55 98 9 685 100 1137 M N W3 6 10 W4 (15) 500 1 "G" O 476 P W1 4 W2 3 (15) 150 (1) COMPRESSOR (2) ELECTRICAL PANEL (3) INTERNAL EXCHANGER (4) EXTERNAL EXCHANGER (5) FAN (6) PUMP (7) EXPANSION VESSEL (8) WATER OUTLET 1" GAS (9) WATER INLET 1" GAS (10) ECONOMISER EXCHANGER (11) CONDENSATE DISCHARGE (12) AUXILIARY ELECTRIC HEATERS (OPTIONAL) (13) 3-WAY VALVE WATER LINE (OPTIONAL) (14) SANITARY WATER OUTLET 1"F GAS (OPTIONAL) (15) CLEARANCE ACCESS RECOMMENDED (G) BARYCENTRE Size 41 61 M mm 466 457 N mm 671 680 O mm 224 226 P mm 252 250 Length mm 1120 1120 Depth mm 524 524 Height mm 1176 1176 W1 kg 42 45 W2 kg 29 30 W3 kg 47 50 W4 kg 33 33 Operating weight kg 150 157 Shipping weight kg 153 160 15

DIMENSIONAL DRAWING 1526 557 12 2 7 5 10 12 2 3 5 1224 8 6 13 242 177 117 11 11 80 1 60 14 9 1065 106 124 M N W3 6 10 5 5 W4 (15) 500 O 1 "G" P 508 W1 W2 3 (15) 150 1543 4 (1) COMPRESSOR (2) ELECTRICAL PANEL (3) INTERNAL EXCHANGER (4) EXTERNAL EXCHANGER (5) FAN (6) PUMP (7) EXPANSION VESSEL (8) WATER OUTLET 1" GAS (9) WATER INLET 1" GAS (10) ECONOMISER EXCHANGER (11) CONDENSATE DISCHARGE (12) AUXILIARY ELECTRIC HEATERS (OPTIONAL) (13) 3-WAY VALVE WATER LINE (OPTIONAL) (14) SANITARY WATER OUTLET 1"F GAS (OPTIONAL) (15) CLEARANCE ACCESS RECOMMENDED (G) BARYCENTRE Size 81 M mm 526 N mm 1017 O mm 266 P mm 242 Length mm 1526 Depth mm 557 Height mm 1224 W1 kg 92 W2 kg 48 W3 kg 83 W4 kg 43 Operating weight kg 266 Shipping weight kg 270 CLIVET SPA Feltre (BL) - Italy Tel. + 39 0439 3131 Fax + 39 0439 313300 info@clivet.it CLIVET UK LTD Fareham, Hampshire - UK United Kingdom Tel. + 44 (0) 1489 572238 Fax + 44 (0) 1489 573033 info@clivet-uk.co.uk CLIVET SAS France Tel. + 33 (0)1 69202575 Fax + 33 (0)1 69206076 info.fr@clivet.com CLIVET ESPAÑA S.A. Madrid - España Tel. + 34 91 6658280 Fax + 34 91 6657806 info@clivet.es CLIVET GmbH Norderstedt - Germany Tel. + 49 (0) 40 32 59 57-0 Fax + 49 (0) 40 32 59 57-194 info.de@clivet.com CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel. + 31 (0) 33 7503420 Fax + 31 (0) 33 7503424 info@clivet.nl CLIVET RUSSIA Moscow, Russia Tel. + 74956462009 Fax + 74956462009 info.ru@clivet.com CLIVET MIDEAST FZC Dubai Silicon Oasis - Dubai,UAE Tel. + 97 14 3208499 Fax + 97 14 3208216 info@clivetme.com CLIVET AIRCONDITIONING SYSTEMS (P) LTD Mumbai 400 072 (INDIA) Tel + 91-22 - 6193 7000 Fax + 91-22 - 6193 7001 sales.india@clivet.com