Rørsystemer til nedgravning i jord

Similar documents
Fodværn Metoder til prøvning af fodtøj

Railway applications Automated urban guided transport (AUGT) Safety requirements

Åndedrætsværn Prøvningsmetoder Del 7: Bestemmelse af partikelfilterpenetration

Sikring af rumfartsprodukter Fejltræsanalyse Meddelelse om godkendelse af ECSS/IEC 61025

Medicinske termometre Del 2: Termometre med faseskift (punktmatrix)

Fertilizers Determination of ammoniacal nitrogen

Katodisk beskyttelse af stål i beton

Isolerende væsker Måling af relativ permittivitet, dielektrisk tabsfaktor (tan ) og jævnstrømsmodstand

Lastsikring på køretøjer Sikkerhed Del 3: Surringskæder

Belysningsarmaturer Del 2-8: Særlige krav Håndlamper

Viklingstråd Prøvningsmetoder Del 6: Termiske egenskaber

Prøvning af installationers brandmodstandsevne Del 10: Røgspjæld

Bæredygtighed inden for byggeri og anlæg Vurdering af bygningers miljømæssige kvalitet Beregningsmetode

Klæbestoffer Prøvning af peelstyrke af limede prøveemner, fleksibelt materiale mod stift Del 1: Peelstyrke ved 90 afrivningsvinkel

Befæstelseselementer Tynde låsemøtrikker med ikke-metallisk indlæg

Emballage Brailleskrift på emballage til lægemidler

Specifikationer for specielle typer viklingstråd Del 8: Rund kobbertråd lakisoleret med polyesterimid, klasse 180

Transportable vægsave og trådsave til byggepladser Sikkerhed

Plastics Recycled Plastics Characterisation of plastics wastes

Værktøjsmaskiner Sikkerhed Transfer- og specialmaskiner

Krafttransformere Del 2: Temperaturstigning for væskefyldte transformere

Koaksiale kommunikationskabler Del 11: Gruppespecifikation for halvstive kabler med polyethylendielektrikum (PE)

Audio- og videoudstyr samt relateret udstyr Bestemmelse af strømforbrug Del 1: Generelt

Kabelforskruninger til elektriske installationer

Elproducerende vindmøller Del 22: Overensstemmelsesprøvning og certificering

Pumper og pumpeenheder til væsker Almene sikkerhedskrav

Aseptisk behandling af sundhedsplejeprodukter Del 6: Isolationssystemer

Bygningskomponenter og bygningsdele Værdier for termisk isolans og transmissionskoefficient Beregningsmetode

Faste isoleringsmaterialers dielektriske og resistive egenskaber Del 1: Generelt

Brandpumper Centrifugalpumper med ansugningssystem Del 1: Klassifikation Generelt og sikkerhedskrav

Fotovoltaik i bygninger Del 1: BIPV-moduler

Elektriske installationer i skibe Del 353: Kabler til nominelle spændinger på 1 kv og 3 kv

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :2012

Robotter til industrielle omgivelser Sikkerhedskrav Del 1: Robot

Trykbærende udstyr til kølesystemer og varmepumper Del 2: Rør Generelle krav

Jernbaneanvendelser Elektromagnetisk kompatibilitet Del 1: Generelt

Bygningskomponenters termiske ydeevne Dynamisk-termiske egenskaber Beregningsmetoder

Metode til prøvetagning af isolerende væsker

Klassifikation af miljøbetingelser Del 2-1: Miljøbetingelser i naturen Temperatur og fugtighed

Metode til bestemmelse af krævede afstande mellem kondensatorer og modstande med ensrettede afslutninger

Kabelfremføringssystemer Kabelbindere til elektriske installationer (IEC 62275:2013, modificeret)

Animalske og vegetabilske fedtstoffer og olier Prøveudtagning

Vejudstyr Støjafskærmning til dæmpning af trafikstøj Procedurer til vurdering af langtidsydeevne Del 2: Ikke-akustiske karakteristika

Miljøledelse Miljømæssig vurdering af anlægsområder og organisationer

Eurocode 3: Stålkonstruktioner Del 5: Pilotering

Metalliske materialer Tyndplade og bånd Bestemmelse af plastisk tøjningsforhold

Jernbaneanvendelser Kommunikations-, signal- og processystemer Sikkerhedsrelateret kommunikation i transmissionssystemer

Tandpleje Lyspolymeriseringslamper Del 1: Quartz-tungsten-halogenlamper

Evaluering og rutineprøvning i billeddiagnostiske afdelinger Del 3-2: Leveringsprøvning Mammografisk røntgenudstyrs billeddiagnostiske egenskaber

Statiske VAR-kompensatorer (SVC) Prøvning af tyristorventiler

Belysningsarmaturers ydeevne Del 2-1: Særlige krav til LEDbelysningsarmaturer

Belysningsarmaturer Del 2-20: Særlige krav Lyskæder

Højspændingskoblingsudstyr Del 110: Afbrydelse af induktiv belastning

FOR COMMERCIAL USE OR REPRODUCTION

Coatinganlæg Sprøjtekabiner til coating med organiske væsker Sikkerhedskrav

Termoplastiske elastomerer Nomenklatur og forkortelser på termer

Bestemmelse af flammepunkt Pensky-Martens closed cupmetode

Plast Bestemmelse af krybeegenskaber Del 2: Krybning ved trepunktsbøjningsbelastning

Metalliske materialer Trækprøvning Del 1: Prøvningsmetode ved rumtemperatur

Sterilisation af sundhedsplejeprodukter. Del 1: Generelle krav. Dansk standard DS/EN ISO

Sikkerhedskrav til elektrisk måle-, regulerings- og laboratorieudstyr Del 2-091: Særlige krav til røntgenskabe

Overvågnings- og alarmcentraler Del 1: Krav til placering og konstruktion

Plastrørsystemer til vandforsyning samt til dræn og afløb under tryk Polyethylen (PE) Del 4: Ventiler til vandforsyning

Ufyrede trykbeholdere Del 1: Generelt

Vejledende information om anvendelse af kondensatorer, modstande, induktorer og komplette filteranlæg til dæmpning af elektromagnetiske forstyrrelser

Terminologi for VSC-omformere til HVDC-systemer

Bygningsbeslag Panikudgangsbeslag betjent ved vandret stang til brug i flugtveje Krav og prøvningsmetoder

Textilmaskiner Sikkerhedskrav Del 4: Maskiner til fremstilling af garn, tovværk og reb

Vandundersøgelse Ammoniumnitrogen Flowanalyse (CFA og FIA) og spektrometrisk detektion

Brændselsceller Del 2: Brændselscellemoduler

COPYRIGHT Danish Standards Foundation. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN :2012

Øjenoptik Oftalmologiske instrumenter Grundlæggende krav og prøvningsmetoder Del 1: Almene krav gældende for alle typer oftalmologiske instrumenter

Bygningers termiske ydeevne Bestemmelse af bygningers luftgennemtrængelighed Prøvningsmetode med overtryk skabt af ventilator

Sterilisation af sundhedsplejeprodukter Kemiske indikatorer Del 1: Generelle krav

Renovationsvogne og deres løfteanordninger Generelle krav og sikkerhedskrav Del 3: Renovationsvogne med læsning foran

Gasfyrede loftsmonterede rørstrålevarmere med enkeltbrændere, ej husholdning Del 1: Sikkerhed

Pumper Tætningsløse rotodynamiske pumper Klasse 2 Specifikationer

Kosmetik Mikrobiologi Påvisning af Candida albicans

Elproducerende vindmøller Del 26-2: Produktionsbaseret rådighed for vindmøller

Anæstesi- og respirationsudstyr Kompatibilitet med oxygen

Geoteknisk undersøgelse og prøvning - Driftsprøvning Del 12: CPT-sondering

Ikke-aktive kirurgiske implantater Ledimplantater Særlige krav til hofteledsimplantater

Elektrisk rumopvarmning, gulvvarme, karakteristika for ydeevne Definitioner, prøvningsmetoder, dimensionering og formelsymboler

Mobile og faste offshoreenheder Elektriske installationer Del 2: Systemdesign

Geometriske produktspecifikationer (GPS) Overfladebeskaffenhed Areal Del 71: Målenormaler i form af software

Gasflasker Genfyldelige sømløse gasflasker Akustisk emissionsprøvning ved periodisk inspektion

COPYRIGHT Danish Standards Foundation. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN :2012

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN :2012

Isolations- og kappematerialer til lavspændingsforsyningskabler Del 0: Generel introduktion

LPG-udstyr og -tilbehør LPG-fremdrivningssystemer til både, yachter og andre fartøjer

Metalliske materialer Charpy-pendulslagsejhedsprøvning Del 2: Verifikation af prøvningsmaskiner

Højspændingskoblingsudstyr Del 207: Seismisk kvalifikation af gasisolerede koblingssamlinger til nominelle spændinger over 52 kv

Mælk Bestemmelse af frysepunkt Termistorkryoskopmetode (referencemetode)

identifikation Identifikation af terminaler på udstyr, tilslutninger og ledere

Injektionsbeholdere og tilbehør Del 4: Injektionsflasker af støbt glas

Akustik - Måling af støj fra kompressorer og vakuumpumper Teknikermetode (Klasse 2)

Olie- og naturgasindustrien Rørsystemer Prøvningsprocedurer for mekaniske connectors

Primærbatterier Del 2: Fysiske og elektriske specifikationer

Termisk isolering i byggeriet Fabriksfremstillede produkter af ekspanderet perlit (EPB) Specifikation

Forberedelse af prøver til måling af kviksølvindhold i lysstofrør

Transcription:

Dansk standard DS/EN 61386-24 1. udgave 2010-10-26 Installationsrørsystemer til kabelfremføring Del 24: Særlige krav Rørsystemer til nedgravning i jord Conduit systems for cable management Part 24: Particular requirements Conduit systems buried underground

DS/EN 61386-24 København DS projekt: M243983 ICS: 29.120.10 Første del af denne publikations betegnelse er: DS/EN, hvilket betyder, at det er en europæisk standard, der har status som dansk standard. Denne publikations overensstemmelse er: IDT med: IEC 61386-24 ED 1.0:2004. IDT med: EN 61386-24:2010. DS-publikationen er på engelsk. Denne publikation erstatter: DS/EN 50086-2-4:1995 og DS/EN 50086-2-4/A1:2002. DS-publikationstyper Dansk Standard udgiver forskellige publikationstyper. Typen på denne publikation fremgår af forsiden. Der kan være tale om: Dansk standard standard, der er udarbejdet på nationalt niveau, eller som er baseret på et andet lands nationale standard, eller standard, der er udarbejdet på internationalt og/eller europæisk niveau, og som har fået status som dansk standard DS-information publikation, der er udarbejdet på nationalt niveau, og som ikke har opnået status som standard, eller publikation, der er udarbejdet på internationalt og/eller europæisk niveau, og som ikke har fået status som standard, fx en teknisk rapport, eller europæisk præstandard DS-håndbog samling af standarder, eventuelt suppleret med informativt materiale DS-hæfte publikation med informativt materiale Til disse publikationstyper kan endvidere udgives tillæg og rettelsesblade DS-publikationsform Publikationstyperne udgives i forskellig form som henholdsvis fuldtekstpublikation (publikationen er trykt i sin helhed) godkendelsesblad (publikationen leveres i kopi med et trykt DS-omslag) elektronisk (publikationen leveres på et elektronisk medie) DS-betegnelse Alle DS-publikationers betegnelse begynder med DS efterfulgt af et eller flere præfikser og et nr., fx DS 383, DS/EN 5414 osv. Hvis der efter nr. er angivet et A eller Cor, betyder det, enten at det er et tillæg eller et rettelsesblad til hovedstandarden, eller at det er indført i hovedstandarden. DS-betegnelse angives på forsiden. Overensstemmelse med anden publikation: Overensstemmelse kan enten være IDT, EQV, NEQ eller MOD IDT: Når publikationen er identisk med en given publikation. EQV: Når publikationen teknisk er i overensstemmelse med en given publikation, men præsentationen er ændret. NEQ: Når publikationen teknisk eller præsentationsmæssigt ikke er i overensstemmelse med en given standard, men udarbejdet på baggrund af denne. MOD: Når publikationen er modificeret i forhold til en given publikation.

EUROPEAN STANDARD EN 61386-24 NORME EUROPÉENNE EUROPÄISCHE NORM October 2010 ICS 29.120.10 Supersedes EN 50086-2-4:1994 + corr. Feb.2001 + A1:2001 English version Conduit systems for cable management - Part 24: Particular requirements - Conduit systems buried underground (IEC 61386-24:2004) Systèmes de conduits pour la gestion du câblage - Partie 24: Règles particulières - Systèmes de conduits enterrés dans le sol (CEI 61386-24:2004) Installationsrohrsysteme zum Führen von Leitungen für elektrische Energie und für Information - Teil 2-4: Besondere Anforderungen für erdverlegte Elektroinstallationsrohrsystem (IEC 61386-24:2004) This European Standard was approved by CENELEC on 2010-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61386-24:2010 E

EN 61386-24:2010-2 - Foreword The text of the International Standard IEC 61386-24:2004, prepared by SC 23A, Cable management systems, of IEC TC 23, Electrical accessories, was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 61386-24 on 2010-10-01 without any modification. This European Standard supersedes EN 50086-2-4:1994 + corr. Feb.2001 + A1:2001. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-10-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-10-01 This Part 24, which specifies particular requirements for conduit systems buried underground, is to be used in conjunction with EN 61386-1, Conduit systems for cable management Part 1: General Requirements, and its amendments. It was established on the basis of the first edition (2004) of that standard and its Amendment 1 (2000). This Part 24 supplements or modifies the corresponding clauses of EN 61386-1. Where a particular clause or subclause of Part 1 is not mentioned in this Part 24, that clause or subclause applies as far as is reasonable. Where this Part 24 states "addition", "modification" or "replacement", the relevant text of Part 1 is to be adapted accordingly. Subclauses, tables and figures which are in addition to those in Part 1 are numbered starting with 101. A conduit system which complies with this standard, is deemed safe for use when installed in accordance with national wiring regulations, whilst applying the manufactures installation instructions and conduit classification. NOTE The following print types are used: requirements: in roman type test specifications: in italic type notes: in small roman type EN 61386 consists of the following parts, under the general title Conduits systems for cable management: Part 1: General requirements Part 21: Particular requirements Rigid conduit systems Part 22: Particular requirements Pliable conduit systems Part 23: Particular requirements Flexible conduit systems Part 24: Particular requirements Conduit systems buried underground Part 25: Particular requirements Conduit fixing devices Future standards in this series will carry the new general title as cited above. Titles of existing standards in this series will be updated at the time of the next edition. Annexes ZA and ZB have been added by CENELEC.

- 3 - EN 61386-24:2010 Endorsement notice The text of the International Standard IEC 61386-24:2004 was approved by CENELEC as a European Standard without any modification.

EN 61386-24:2010-4 - Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Annex ZA of Part 1 is applicable except as follows: EN 60423, Not applicable EN 60670, Not applicable Addition: Publication Year Title EN/HD Year ISO 161-1 1996 Thermoplastics pipes for the conveyance of fluids - Nominal outside diameters and nominal pressures - Part 1: Metric series ISO 2768-1 1989 General tolerances - Part 1: Tolerances for linear and angular dimensions without individual tolerance indications - - EN 22768-1 1993

- 5 - EN 61386-24:2010 Annex ZB (normative) Special national conditions Special national condition: National characteristic or practice that cannot be changed even over a long period, e.g. climatic conditions, electrical earthing conditions. NOTE If it affects harmonization, it forms part of the European Standard or Harmonization Document. For the countries in which the relevant special national conditions apply these provisions are normative, for other countries they are informative. Clause General Special national condition Denmark According to the installation practice in Denmark conduit systems buried underground have to be in the colour red no 5 according to DS 735 (1982) or red according to IEC 304 (1982).

NORME INTERNATIONALE INTERNATIONAL STANDARD Systèmes de conduits pour la gestion du câblage Partie 24: Règles particulières Systèmes de conduits enterrés dans le sol Conduit systems for cable management Part 24: Particular requirements Conduit systems buried underground CEI IEC 61386-24 Première édition First edition 2004-07 Numéro de référence Reference number CEI/IEC 61386-24:2004

61386-24 IEC:2004 3 CONTENTS FOREWORD...5 1 Scope...9 2 Normative references...9 3 Definitions...9 4 General requirements...9 5 General conditions for tests...9 6 Classification...9 7 Marking and documentation...11 8 Dimensions...13 9 Construction...13 10 Mechanical properties...13 11 Electrical properties...17 12 Thermal properties...17 13 Fire effects...17 14 External influences...19 15 Electromagnetic compatibility...19 Annex A (normative) Classification coding for conduit systems...27 Annex B (normative) Determination of material thickness...27 Figure 101 Impact test apparatus...23 Figure 102 Bending test apparatus...25 Table 101 conduits diameters...19 Table 102 Impact test energy values...21

61386-24 IEC:2004 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION CONDUIT SYSTEMS FOR CABLE MANAGEMENT Part 24: Particular requirements Conduit systems buried underground FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as IEC Publication(s) ). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61386-24 has been prepared by subcommittee 23A: Cable management systems, of IEC technical committee 23: Electrical accessories. The text of this standard is based on the following documents: FDIS 23A/446/FDIS Report on voting 23A/459/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

61386-24 IEC:2004 7 This Part 24, which specifies particular requirements for conduit systems buried underground, is to be used in conjunction with IEC 61386-1, Conduit systems for cable management Part 1: General Requirements 1, and its amendments. It was established on the basis of the first edition (1996) of that standard and its Amendment 1 (2000). This Part 24 supplements or modifies the corresponding clauses of IEC 61386-1. Where a particular clause or subclause of Part 1 is not mentioned in this Part 24, that clause or subclause applies as far as is reasonable. Where this Part 24 states "addition", "modification" or "replacement", the relevant text of Part 1 is to be adapted accordingly. Subclauses, tables and figures which are in addition to those in Part 1 are numbered starting with 101. A conduit system which complies with this standard, is deemed safe for use when installed in accordance with national wiring regulations, whilst applying the manufactures installation instructions and conduit classification. NOTE The following print types are used: requirements: in roman type test specifications: in italic type notes: in small roman type IEC 61386 consists of the following parts, under the general title Conduits systems for cable management: Part 1: General requirements Part 21: Particular requirements Rigid conduit systems Part 22: Particular requirements Pliable conduit systems Part 23: Particular requirements Flexible conduit systems Part 24: Particular requirements Conduit systems buried underground Future standards in this series will carry the new general title as cited above. Titles of existing standards in this series will be updated at the time of the next edition. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. 1 Please note that the generic title of the IEC 61386 series has been changed to Conduit systems for cable management since the publication of Part 1, hence all other parts of the series are now published under this new title.

61386-24 IEC:2004 9 CONDUIT SYSTEMS FOR CABLE MANAGEMENT Part 24: Particular requirement Conduit systems buried underground 1 Scope Replacement: This standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems. This standard applies to metallic, non-metallic and composite systems including threaded and nonthreaded entries which terminate the system. 2 Normative references This clause of Part 1 is applicable except as follows: IEC 60423, Not applicable IEC 60670, Not applicable Addition: ISO 161-1:1996, Thermoplastics pipes for the conveyance of fluids Nominal outside diameters and nominal pressures Part 1: Metric series ISO 2768-1:1989, General tolerances Part 1: Tolerances for linear and angular dimensions without individual tolerance indications 3 Definitions This clause of Part 1 is applicable. 4 General requirements This clause of Part 1 is applicable. 5 General conditions for tests This clause of Part 1 is applicable. 6 Classification This clause of Part 1 is applicable except as follows: Modification: NOTE Annex A is not applicable.