Catalogue Power Cables

Similar documents
Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Catalogue. Instrumentation & Control Cables

Catalogue Telecommunication Cables INTRODUCCIÓN

Telecommunication Cables

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Shipboard & Offshore Cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

BS /1000V XLPE Insulation LSZH Sheath Cables

Tratos Railway Cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

OIL & GAS INDUSTRY OTHER INDUSTRIES

PRODUCT CATALOGUE Norröna

FIRE RESISTANT CABLES

Havells Fire Survival Cables

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Caledonian Flame Retardant Coaxial Cables

Flexible Power Cable DLO

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

High Performance LSZH Fire Resistant Cable

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Caledonian Fire resistant Coaxial Cables

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Power Control Cable Iec

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Evolution of Cable Fire Safety Standards in Australia

Total Fire Solutions. Includes BS 8519 and the updated BS :

LV FIRE RESISTANT CABLES

The Quality Connection. BETAflam Fire Resistant Safety Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Wires, Cables, Cords and Adhesive Tapes

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

CONNECTION SYSTEMS TRANSIT APPLICATIONS

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

fire resistant cables

A Look at General Cable s GenFree II Product Line

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Multi-Core Fire Resistant Cable

INTERNATIONAL STANDARD

ENHANCED FIRE PERFORMANCE CABLE

DNVGL-CP-0399 Edition March 2016

FIRE RESISTANT CABLES FP300

THE TRUE FIRE SURVIVAL CABLE

Cable technology for highest safety requirements

INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION

Low Smoke Zero Halogen

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

STANDARDS INSTALLATION. Certificate No 077m

QUALITY THROUGH EXPERIENCE

SOLAR CABLES. Electric cables for solar PV installations

Introduction.

SECTION ELECTRICAL GENERAL PROVISIONS

DNVGL-CP-0401 Edition February 2016

PRODUCT RANGE.

INTERNATIONAL STANDARD

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

SAS Security and Alarm Safety Cables

FIRE PERFORMANCE CABLE

HELKAMA. Optical Fibre Cables

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

More than Just a Cable Supplier

Compact Module. Category 6A FTP Cabling System 1.1

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

FIRE RESISTANT CABLES FP400

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Firecel Safety Cables

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Caledonian fire Resistant signal & Data cables

Traction Cable Radox 3 GKW

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

(Notices) EUROPEAN COMMISSION

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Nuclear Power Plant LSZH Cable Overview

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Cablosam Tapes for Fire-Resistant Cables

Photovoltaic Cables EN H1Z2Z2-K

Fire Resistant Cables

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

Transcription:

Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es

Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es

INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically designed for supplies with a 0.6/1 kv voltage service range in energy & control applications. The most commonly used configurations are: RV. Unarmoured Cables RVMV. Steel Wire ed Cables RVSV. Corrugated Steel Tape ed Cables RVFV. Steel Tape ed Cables According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN 50200 & UNE-EN 50362 Fire retardant. IEC 60332-3 Cat. C & UNE-EN 50266 Cat. C Flame retardant. IEC 60332-1 (UNE-EN 60332-1-1) & IEC 60332-2 (UNE-EN 60332-1-2) Low Smoke Emission. IEC 61034 (UNE-EN 61034) Halogen free. IEC 60754 (UNE-EN 50267) OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN 60811-2-1 & UIC 895 OR Configurations with different types of armours and materials Conductores Tecnológicos S.A. 3 www.contecsa.es

POWER CABLES RV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. Suitable for outdoor and indoor services, they can be installed in ducts, trays or conduits. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Conductores Tecnológicos S.A. 4 www.contecsa.es

POWER CABLES RVMV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ thermoplastic (Low Smoke Zero Galvanized steel wires. *OPTION, aluminium wires. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ thermoplastic (Low Smoke Zero Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The steel armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium wires Conductores Tecnológicos S.A. 5 www.contecsa.es

POWER CABLES RVSV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Steel corrugated tape. Thickness: from 0.15 to 0.50 mm. *OPTION, Aluminium corrugated tape. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium corrugated tape Conductores Tecnológicos S.A. 6 www.contecsa.es

POWER CABLES RVFV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Steel tape helicoidally placed. Thickness: from 0.15 to 0.50 mm. *OPTION, aluminium tape helicoidally placed. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour of steel tape helicoidally placed provides very high mechanical and anti rodent protection with high flexibility. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium tape helicoidally placed Conductores Tecnológicos S.A. 7 www.contecsa.es

Rev. 0 (01/12/2009) If you want to know more about us, please visit www.contecsa.es Conductores Tecnológicos S.A. 8 www.contecsa.es