Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es
Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es
INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically designed for supplies with a 0.6/1 kv voltage service range in energy & control applications. The most commonly used configurations are: RV. Unarmoured Cables RVMV. Steel Wire ed Cables RVSV. Corrugated Steel Tape ed Cables RVFV. Steel Tape ed Cables According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN 50200 & UNE-EN 50362 Fire retardant. IEC 60332-3 Cat. C & UNE-EN 50266 Cat. C Flame retardant. IEC 60332-1 (UNE-EN 60332-1-1) & IEC 60332-2 (UNE-EN 60332-1-2) Low Smoke Emission. IEC 61034 (UNE-EN 61034) Halogen free. IEC 60754 (UNE-EN 50267) OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN 60811-2-1 & UIC 895 OR Configurations with different types of armours and materials Conductores Tecnológicos S.A. 3 www.contecsa.es
POWER CABLES RV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. Suitable for outdoor and indoor services, they can be installed in ducts, trays or conduits. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Conductores Tecnológicos S.A. 4 www.contecsa.es
POWER CABLES RVMV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ thermoplastic (Low Smoke Zero Galvanized steel wires. *OPTION, aluminium wires. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ thermoplastic (Low Smoke Zero Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The steel armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium wires Conductores Tecnológicos S.A. 5 www.contecsa.es
POWER CABLES RVSV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Steel corrugated tape. Thickness: from 0.15 to 0.50 mm. *OPTION, Aluminium corrugated tape. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium corrugated tape Conductores Tecnológicos S.A. 6 www.contecsa.es
POWER CABLES RVFV 0.6/1 KV Construction: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. * OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Poly ethylene). *OPCIONAL, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Steel tape helicoidally placed. Thickness: from 0.15 to 0.50 mm. *OPTION, aluminium tape helicoidally placed. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSHZ Application & Properties: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour of steel tape helicoidally placed provides very high mechanical and anti rodent protection with high flexibility. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. Standards: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium tape helicoidally placed Conductores Tecnológicos S.A. 7 www.contecsa.es
Rev. 0 (01/12/2009) If you want to know more about us, please visit www.contecsa.es Conductores Tecnológicos S.A. 8 www.contecsa.es