Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Similar documents
SPM Flex Chemcassette Tape-Based Gas Detector

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Product ProRAE Studio II Version V Operating Systems Windows 7(x86 and x64), Windows 10 Release Date December 2018

Operating Instructions

Touchpoint Pro Flexible Gas Control System

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

AreaRAE Pro Wireless, transportable area monitor Remote visibility on more threats than ever for an enhanced level of real-time situational

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Sensepoint XCL Fixed Gas Detector

Honeywell Analytics. Order List BW Clip & IntelliDoX

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Operating Instructions and Maintenance Manual

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

AreaRAE Plus Wireless, transportable area monitor Visibility on more gas threats than ever all in one versatile, easy-to-use device.

MeshGuard and MeshGuard Gamma

MeshGuard and MeshGuard Gamma

All users are recommended to update their existing ProRAE Guardian (PRG) software to v

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Life Safety Network. Intelligent solutions for advanced requirements

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

User Guide. MeshGuard Gamma

Gas Detection. Touchpoint Plus. A whole new control experience

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Searchpoint Optima Plus

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Operating Instructions

Searchpoint Optima Plus

System 57. An advanced World of intelligent gas detection system management

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Touchpoint Plus. A whole new control experience

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

SPM Flex Single Point Monitor Gas Detector

Product Specifications

White Paper. Critical Considerations for Monitoring Low Levels of Hydrogen Sulfide. by Jacob Spector and Kirk Johnson

System 57. An advanced world of intelligent gas detection system management

MeshGuard TM Monitor User s Guide

Installation Guide and Operating Manual

XNX Universal Transmitter

Installation Guide and Operating Manual Fire Detector with 20-foot Pigtail Cable Model FS RP

SPM Flex Chemcassette Tape-Based Gas Detector

EC FX NH3. A new and improved approach to ammonia gas detection

Fixed-Point Industrial Gas Detection

Multi-Spectrum Digital Electro-Optical Fire Detectors

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Waters 2795 Separations Module

Zareba Unipoint controller

Zareba Sensepoint Pro

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Fixed-Point Industrial Gas Detection

Zareba System Overview

APPLIED. OMA-406R Rackmount Process Analyzer

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Technical Manual. Zareba Sensepoint Gas Detectors

Neotronics portable gas detection. Portable protection from hazardous gas

Waters 2695 Separations Module

Return loss measurement of fiber optic components

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

safe and your operations compliant

Zareba Metro Gas Detector

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Lumidor portable gas detection. Portable protection from hazardous gas

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

OMA-300 Process Analyzer

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Waters 2695D Separations Module

Sieger fixed gas detection. Fixed protection from hazardous gas

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Wireless Alarm Bar TM Installation Guide

Duct Mount. Installation Instructions

600 Range Dialer Installation Manual. Version 1.0

Touchpoint Plus. A whole new control experience

Application Note #451 Revision B June 2012

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

Dräger Pac 5500 Single-Gas Detection Device

3820, 3820i, 4820, 4820i

The New DUSTTRAK II and DRX Aerosol Monitors

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Moxa Proactive Monitoring User s Manual

The New DUSTTRAK II and DRX Aerosol Monitors

hgate Product Catalog

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Transcription:

SPM Flex TM Software Release 1.0.6 1998-1017 Rev 1 5/18 Honeywell Analytics is pleased to announce the release of Version 1.0.6 firmware software for the SPM Flex TM product line. Firmware 1.0.6 Update Firmware update provides improved optics parameter check and optics auto adjustment procedures with extended run time SPM Flex Firmware 1.0.5 and earlier versions allowed only Honeywell service engineers with a secure pass code to perform optics parameter checks and optics auto adjustments. Customer feedback and field trials of SPM Flex Isocyanate units running in customer sites has shown optics adjustment failure and high background failure conditions at customer sites. Firmware change summary The firmware modifications address the optics adjustment for the SPM Flex isocyanate applications without in-line dust filters in dirty or dusty environments. The firmware has been updated to allow optics to use maximum values rather than rejecting maximum calibrations. In dusty or dirty environments, the instrument will continue to monitor, however the expanded range reduces service. Factory Optics Calibration no change Parameter Low Limit High Limit LED Drive 1200 2500 Primary PD 3180 3220 Reference PD 1300 3100 Service Optics Calibration Parameter Low Limit Original Modified High Limit Original Modified LED Drive 1200 3500 Primary PD 3180 2300 3220 Reference PD 1300 3500 3995 Optics Verification Optics Auto Adjust Original Modified Limit White Gray Max 3400 2600 Min 3000 2100 1800 1200 Page 1 of 11

The Optics Verification numbers are going to be proportional to the OAA (Optics Auto Adjust) numbers. Optics verification numbers are same for Factory & Service. User Interface (UI) Menu Changes Menu structure of UI application has been modified so a routine maintenance engineer can access optics adjustment functions and check the optics counts. Optics auto adjustment menu moved up from Maintenance Factory Service menu to Maintenance menu Detailed Diagnostics menu moved from Maintenance Factory Service menu to Review menu Access Level Changes Access level for the menu items below has been changed from Honeywell service engineer to routine maintenance engineer. Optics auto adjustment Detailed diagnostics Page 2 of 11

Installation of Firmware 1.0.6: 1. Insert USB flash drive with Firmware Package Ver. 1.0.6 to the USB Port 2. Go to Update Program Maintenance Mode 3. Select SPMFlex_Package_1.0.6 Page 3 of 11

4. Wait until completion of the Firmware update. Do not power off during update process. Optics Parameter Check Procedure with Optics Test Card: 1. Exit Monitor Mode. Select Monitor Mode Out of monitor mode Main Menu Page 4 of 11

2. To Remove Chemcassette Tape. Select Main Menu Maintenance Open/Close gate Open gate Gate is opened. Remove Chemcassette Tape. Page 5 of 11

3. Insert Optics Card - White Chip. Select Open/Close gate Close gate Gate is closed. Ensure gate is closed. Note: Ensure gate is closed! 4. Check & Record Optics Parameters. Select Maintenance Main Menu Review Mode Detailed diagnostics. Record Optics Parameters. Take Screen Shot. Page 6 of 11

5. To Remove Optics Card. Review Mode. Main Menu Maintenance Open/Close gate Open gate Gate is opened. Remove Optics Card. Note: Remove Optics Card! Page 7 of 11

6. To install Chemcassette tape. Maintenance Open/Close gate Close gate Gate is closed. Install Chemcassette tape. Note: Install Chemcassette tape! 7. To Start Monitoring. Maintenance Monitor Mode Enter monitor mode. Page 8 of 11

Optics Auto Adjustment Procedure with Optics Test Card: 1. Exit Monitoring Mode Enter Maintenance Mode 2. Select Optics Set Up / Auto-Adjust 3. Remove Chemcassette Tape. Insert Optics Card White Chip. Select Continue. Page 9 of 11

4. Remove Optics Card White Chip. Install Chemcassette Tape. Select Continue. #END If for any reason the update was not correctly completed, please contact your local Honeywell Analytics service team. The updates are supplied via USB flash drives and with optics calibration card included. Software update 1.0.6 will not be available via the Website as normal due to the need for an optics calibration card to be able to use the new function. Page 10 of 11

Find out more: www.honeywellanalytics.com www.raesystems.com Contact Honeywell Analytics: Europe, Middle East, Africa Life Safety Distribution GmbH Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Customer Service: Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Fax: 00800 333 222 55 Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Middle East Tel: +971 4 450 5852 (Portable Gas Detection) Americas Honeywell Analytics Distribution Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com RAE Systems by Honeywell Phone: 408.952.8200 Toll Free: 1.888.723.4800 Fax: 408.952.8480 Asia Pacific Honeywell Industrial Safety 7F SangAm IT Tower, 434, Worldcupbuk-ro, Mapo-gu, Seoul 03922, Korea Tel: +82 (0) 2 6909 0300 Fax: +82 (0) 2 2025 0328 India Tel: +91 124 4752700 China Tel: +86 10 5885 8788 3000 analytics.ap@honeywell.com Technical Services EMEA: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com Technical Services ha.us.service@honeywell.com While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This publication is not intended to form the basis of a contract and the company reserves the right to amend the design and specification without notice. Page 11 of 11