MyGel Mini. Operating Manual Version 1.0. a division of. Electrophoresis System

Similar documents
Vertical Gel Systems-Dual CAT NO: EPS-V0011 & EPS-V0012

ASPIRE Laboratory Aspirator

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Induction Cooktop Product Guide (IC200B)

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

4L Instant Water Boiler Instructions for Use

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

SAFEVIEW-MINI2 TRANSILLUMINATOR

MD-MINI Dry Bath. Instruction Manual

Thermo Scientific Laboratory Products. Every Lab, Every Day

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Corning LSE Benchtop Shaking Incubator

POLYMIX PX-IG 2000 Operating Instructions

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

Stick Mixer with Mini Chopper

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER INSTRUCTION MANUAL

Dual-Hose Portable Air Conditioner User Manual

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Model No. NR-BU303 Series

Let s get brewing. Quick Start Guide

C90 Instruction Manual

WATER KETTLE RHKT-15001(white) RHKT-15002(black) Instruction Manual

Thermo Scientific Laboratory Products. Maximizing Productivity for Every Lab, Every Day

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Semi-Auto Washing Machine

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

SLUSH PUPPiE MACHINE Instructions For Use

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

Instruction Manual Lantern / Design by Carsten Jörgensen

Electron Microscopy Sciences. INSTRUCTIONAL MANUAL CAT & Step Up Slide Warmer

A few simple steps to ensure perfect water, every time.

Ultrasonic Aroma Diffuser AD-SD1-CE

1.7Litre Stainless Steel Kettle

Linkam Scientific Instruments USER GUIDE PE120-AFM. Temperature Controlled Peltier Stage

How to Use and Care for Your Sleek

USER GUIDE. Induction Cooktop NS-IC1ZBK8. Before using your new product, please read these instructions to prevent any damage.

Operating Instructions

Digital Heat Block User Manual

Refrigerated Incubator Model and Operating Instructions

VPMmini. Operator's Manual

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

Incubating Shaker with Cooling

Operating & Installation Instructions Fully Automatic Washing Machine (Domestic use)

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

i-cube Microplate Incubator E10030

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Electron Microscopy Sciences

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Operator's Manual. PCP October 2017

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL


SPLIT TYPE. Instruction manual

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

OPERATING INSTRUCTIONS

Gallery Electric Fireplaces

Instructions for use. Model: X2-30ES

MANUAL OWNER S. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE.

User Manual. Heater/Proofer Cabinets. Models: 177HEAT1836, 177HPI1812, 177HPI1836, 177HPU1812, 177HPU1836

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

Instruction Manual. Cellulose Acetate Tank Catalogue Number CSL-CELLAS

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

GW22731/GW22735/GW22743/GW22746

MPE12FG MPE12FS MC

2 000W CYCLONIC BAGLESS VACUUM

Operation Manual. (Version 1.5.1)

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Electric Hand dryer. Installation and operating manual

Contents Safety instructions...3

12L Dehumidifier Model: HG00923

ConserveWell DROP-IN UNIT

Countertop Clear Ice Maker

CONTENT. 11.Specification

Intelligent Super Toilet AFC230 User Instruction Manual

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

Dehumidifier. User Manual

INSTRUCTIONS AND WARRANTY

JT-SB116JH-G-NA JT-SB116JH-W-NA

Instruction Manual. Bucket Oil Pump

Dome Kettle. polished stainless steel body BTDK120

Operating Instructions Air Conditioner

Register your product ONLINE today

Dual Column Dehydrating Breather Manual

IMPORTANT SAFETY INSTRUCTIONS

User manual of CD-2900 ultrasonic contact lens cleaner

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

USER MANUAL ICE MAKER

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

INSTRUCTIONS AND WARRANTY

Operating Instructions Air Conditioner

STEAM GENERATOR. Model: G-1030ST. Instruction Manual

VISUAL DISPLAY DISPENSER OWNERS MANUAL

Inverter Split-type Room Air Conditioner

Twin Tub Washing Machine OWNER S MANUAL

Transcription:

MyGel Mini Electrophoresis System Operating Manual Version 1.0 a division of

Contents 1. Introduction...1 1.1 Included Component List....1 1.2 Component Diagram......2 1.3 Specifications.....3 2. Installation..... 3 3. Warnings.....5 4. Operating Guide....5 4.1 Control Panel Key Functions.....5 4.2 Gel Preparation......... 5 4.3 Electrophoresis.. 7 5 Maintenance Always disconnect the power cord for cleaning. When cleaning the surfaces of the instrument, use a damp cloth with mild detergent if needed. Do not use any corrosive solutions that could damage plastic.. When cleaning the gel tank, first separate the Power Supply. Use water or neutral cleaner. Use caution them cleaning the areas near the platinum electrodes at the bottom edges of the gel tank. Clean gel casting stands, gel tray and combs with water or a neutral cleaner. 6 Troubleshooting Problem Causes Measures 5. Maintenance...9 6. Troubleshooting......9 Thank you for purchasing the Accuris MyGel Mini Electrophoresis System. No display Power not connected. Switch failure. Controller failure. Check power supply, Unplug and re-attach power cord. Replace switch. Contact Benchmark for repair This operating manual includes a product introduction, operating and safety information. Before using the MyGel, please read this manual in its entirety and be sure to fully understand the features and methods for proper operation. Keep this manual for future reference. Please check the packing list when first opening the box, and if there are any parts missing, damaged, or incorrect, please contact your distributor or Benchmark Scientific s Customer Service Department at 908-769-5555 or by email info@benchmarkscientific.com. No Migration Abnormal Electrophoresis Distance Power switch off No power Incorrect input voltage 9 Turn on power switch Contact Benchmark for repair Check main power supply E1 displayed Lid not closed Seat lid properly Key function failure Control panel switch failure Contact Benchmark for repair

4.3.4 Use an appropriate pipette to dispense samples into the wells of the gel. 4.3.5 Attach the lid. The display screen will light when the lid is properly seated and the power switch is turned on. 1. Introduction The MyGel is a complete horizontal electrophoresis system that includes a power supply that directly connects to a gel tank. The system is designed for separating nucleic acids in agarose gel. All components and accessories are included for casting and running small gels. Before use, please read this operating manual in its entirety. Press to set the run time from 1 to 99 min. For a continuous run, set the timer to 00. Press the Voltage Selection button select the output voltage. Press the Stop/Run button once to start a run. The set output voltage LED will blink to indicate a run is in process. At the end of a timed run, the alarm will beep 3 times, and the display will show Ed to indicate END. Press any key to clear Ed and set up another run. To stop a run in process, press and hold Stop/Run for 1 second. The voltage LED will stop blinking to indicate the run has stopped. to Indication light 1.1 Included Components Power Supply and Tank Assembly Power cord Gel Casting Stand (A) Gel Casting Stand (B) Gel Tray (A) Gel Tray (B) Combs (A) Combs (B) AC transformer * User Manual 2 pcs 4 pcs 2 pcs 2 pcs * Note: only model MyGel E includes the AC transformer. 4.3.6 At the end of an electrophoresis run, turn off the power and open the lid to remove the gel tray. 8 1

1.2 Component Diagram 4.3 Electrophoresis Safety Cover Start/Stop Timer setting Note: Make sure that the MyGel System is installed on a stable and level surface to ensure even sample migration. 4.3.1 Place a prepared gel, together with the gel tray onto the gel bed inside the gel tank. Gel Tray Voltage selection Power switch 4.3.2 Pour an appropriate buffer solution to a level about 3mm above the surface of the gel. Generally, 250-300ml of buffer is required. Migration tank Power Supply Platinum electrode 4.3.3 Connect the power supply to the migration tank and insert the electric plug into an outlet. The electric current cannot be turned on with the lid open. Power inlet Fuse Gel tank 2 7

4.2.3 Pour the gel into the gel tray to make a gel approximately 4mm thick. Each 60x110mm tray requires about 25ml of agarose. 1.3 Product Specifications Model Output voltage Timer MyGel Mini 110V DC35V, DC50V, DC100V 0 ~ 99min MyGel Mini 230V 4.2.3 After the gel has solidified (approximately 20 minutes) hold the two sides of comb and gently lift it out of the gel. The wells should be straight and undamaged. Migration Tank Buffer Volume Comb Specs Gel Casting Stands Gel tray Specs Fuse Dimensions Net weight 2 Installation 120mm 110mm 45mm(inner dimension) 250ml-300ml Teeth width x Teeth thickness x Teeth no.) 3mm 1mm 22 / 5.6mm 1mm 12 3mm 1mm 18 / 5.6mm 1mm 10 10.5cm 6cm and 5cm 6cm (Dimension for each section) 10.5cm 6cm and 5cm 6cm 250V 2A 190mm 130mm 55mm (W D H) 0.45 kg(without AC transformer) 4.2.4 Remove the gel tray with the gel from the stand and place it into the migration tank 2.1.1 Place the electrophoresis system on a smooth, level surface. 2.1.2 Connect one end of the power cord to the instrument and the other end to an appropriate outlet, the input voltage should be between 100~120VAC. 2.2 When the input voltage is 220VAC, use the transformer inline. 6 3

3 Warnings To avoid electrical shock, do not use this product with wet hands. When operating, do not move or bump the system, do not put your finger or any other objects into the migration tank. Do not detach the power supply module from the migration tank when the power is on. Attempting to do so can cause damage. Please carefully read this instruction manual before operation to avoid any personal injury. Only trained laboratory personnel should operate the system. Do not attempt to open or repair the MyGel system. Contact your distributor or Benchmark Scientific for service. Always use the MyGel in an environment with low humidity and low dust, also keep it away from water, direct sunlight / strong light, corrosive gas, high magnetic fields, heaters, fires and other heat sources. 4. Operating guide 4.1 Key Functions Stop/Run----Press momentarily to start a run. Press and hold for 1 second to stop a run. ---------Output voltage selection. -----------Time setting, when time is set at 0,display shows 4.2 Gel Preparation 4.2.1 Place the gel casting stand on a level surface, and place the gel trays into the proper positions in the stand. Note: If the gel tray is not level, the thickness of the gel will not be uniform and migration may be uneven. Gel tray Gel stand The power switch is located on the control box, press I to power on, O to turn off. 4.2.2 Insert the comb into the gel casting stand as per photo on the right Comb Always turn off the power after operation. When not in use, detach the power supply and store it in an area that is free from moisture and dust. 4 5