CONTENTS. Important Safety Instructions page 2

Similar documents
Tankless Electric Water Heater MS-C2PSU Series

ELECTRIC WATER HEATER HT382E55

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

Operating and assembly manual: Electric instantaneous flow heater Admiral

DHC-E TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN

Flow Factor ~

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

PRO SERIES IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

OPERATING AND INSTALLATION MANUAL

Installation and Operation Guide

OPERATING AND INSTALLATION MANUAL

OPERATION AND INSTALLATION

Installation and Operation Guide

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

OPERATION & INSTALLATION MANUAL

SAVE THESE INSTRUCTIONS

Installation and Operation Guide

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

SEIH7KTS1,SEIH9KTS1 SEIH11KTS1. Installation Manual. Issue STROM- ELECTRICAL.

EEMAX HOME ADVANTAGE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

EEMAX PROADVANTAGE ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL

EEMAX ProAdvantage Series 1

Eemax, Inc. Electric Tankless Water Heaters

APW-VAP-150P High Pressure Cleaner Operator Manual

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Installation Instructions for. OmniFount

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

OPERATION AND INSTALLATION

INSTALLATION AND OPERATION MANUAL

Installation Instructions for. CattleMaster Series Fountains

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Installation Instructions

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Dishwasher Installation Manual

Manifold Installation Controller MIC-180. Installation and Operation Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

SEISCO MOUNTING CLEARANCES

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

OPERATOR S MANUAL & PARTS LIST

SCHWAN INSTALLATION GUIDE

SMARTBOOST IMPORTANT SAFETY INFORMATION

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Installation Instructions

Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

PJ130S High Pressure Cleaner

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

INSTALLATION INSTRUCTIONS

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

IMPORTANT INSTRUCTIONS READ & SAVE

Installation Instructions for. OmniFount

TH100 Three in One Instant Hot Water Tap

Installation Instructions for. OmniFount

Models Series Series

Installation Instructions

Installation Manual SEIHTP1, SEIHTM1. Issue SEIHTM1 Model Shown STROM- LIMITED.

Installation Instructions

Models Series Series

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

SEISCO - MOUNTING CLEARANCES

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

INSTANT-FLOW C-MICRO WATER HEATER

GARAGE VAC OWNERS MANUAL READ BEFORE OPERATING YOUR SYSTEM

PORTABLE TANKLESS GAS WATER HEATER INSTRUCTION MANUAL GA5MILITAR MODEL

OPERATION AND INSTALLATION

Operating Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

Tankless Water Heater

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Gallery Electric Fireplaces

User Manual. Ceramic Cooktop Model : CRSF745

This manual provides many important safety points. Please read it carefully and follow the instruction rules.

SAFETY INSTRUCTIONS & OPERATION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL TANKLESS WATER HEATER

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Handshower, Hose & Handshower Accessories

Installation Instructions

EH W Pressure Washer

Installation Instructions

ELECTRIC FLAT PANEL FIREPLACE HEATER

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

IMPORTANT INSTRUCTIONS

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Transcription:

Please read and follow the installation and operation instructions carefully, to ensure the long life and reliable operation of this appliance. CONTNTS Important Safety Instructions -------------------------------------------------------------------------------- page 2 lectrical Diagram------------------------------------------------------------------------------------------------ page 3 Technical Data and Product Structure----------------------------------------------------------------------page 4 Installation Guideline---------------------------------------------------------------------------------------------page 6 Operation Instructions ------------------------------------------------------------------------------------------page 10 Trouble-shooting---------------------------------------------------------------------------------------------------page 11 Normal Maintenance----------------------------------------------------------------------------------------------page 12 CANADA USA UV Corp NPV group LLC Markham, Ontario Akron, Ohio 1-866-833-2247 1-800-561-6838

WARNINGS This is not a do-it-yourself project. Failure to have this appliance installed by a licensed plumber and electrician will void all warranties. Under no circumstances should you attempt to install, repair or disassemble the Advantage tankless electric water heater without first shutting off all power to the unit directly at the circuit breaker box. Installation of this product is restricted to indoor locations only by licensed plumbing or electrical contractors. Important Safety Instructions 1. The installation must be in compliance with the National lectrical Code, your local electrical and plumbing codes. 2. This appliance must be ARTHD/GROUNDD. 3. All wiring and installation must be supervised by a qualified electrician. 4. CAUTION: This product has more than one power-supply connection point. Disconnect all power supplies before servicing. 5. This appliance is not intended for use by persons (include children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 6. This appliance MUST be permanently connected to the fixed circuit breaker and it must be installed vertically. DO NOT install this appliance near to flammable materials or strong magnetic fields. 7. This appliance is forbidden to be switch on if you think it may be frozen, as this could result in serious damage to the unit. Wait until you are sure that it has completely thawed out before you switch it on. 8. Please feel the outlet hot water temperature with hand to make sure it is suitable for showering before taking shower to avoid getting scalded. 9. Before connecting pipes to the water heater hoses, it is extremely important to FLUSH the pipes to wash away all plumbing paste or residue in the pipes. 10. The heating chamber is treated with composite nano insulation material; it is natural if there might be a bit of smell or green blue smoke when the unit is used for the first time. 11. If there is damage to the wire, you must contact qualified electrician to replace it with dedicated wire from our authorized dealers. 12. CAUTION: FOR HOUSHOLD AND INDOOR US ONLY 13.CAUTION:Risk of electric shock,connct ONLY TO A CIRCUIT THAT IS PROTCTD BY A GROUND. 14.Save these instructions.

Product Features The Advantage tankless electric water heaters are incorporated with patented technology with multi-safety devices. The unit has the following features. 1. Tankless, instantaneous heating for on demand hot water, No pre-heating. No stand-by heating loss. energy-saving. 2. Micro-computer control, Adopting patented heating technology. Water is completely separated from electricity by multi-layers of composite nano insulation material. 3. Overtemperature protection: when the outlet water temp. reaches over 153 /67, the electricity will be cut off to avoid getting scalded and the screen displays 1. The appliance will start to work automatically when the temp. drops to the set temperature. 4. Malfunction of sensor- when there is malfunction with the temperature sensor, the heater stops working and displays 3 5. Conversion between degree Fahrenheit and degree Celsius. lectrical Diagram MODL ADV120FDCH THRMAL CUT-OUT 95 L1 T1 R1 CONTROL SYSTM L2 T2 R2 OUTLT TMP.SNSOR DISPLAY SCRN INLT TMP.SNSOR FLOWMTR RMARK: J:RLAY R:HATING SYSTM T:TRIAC ADV150FDCH ADV180FDCH THRMAL CUT-OUT 90 L1 T1 R1 L1 CONTROL SYSTM L2 T2 R2 OUTLT TMP.SNSOR DISPLAY SCRN INLT TMP.SNSOR FLOWMTR RMARK: J:RLAY R:HATING SYSTM T:TRIAC

ADV210FDCH ADV240FDCH ADV270FDCH THRMAL CUT-OUT 90 L1 T1 R1 L1 L1 CONTROL SYSTM T2 R2 L2 T3 R3 OUTLT TMP.SNSOR DISPLAY SCRN INLT TMP.SNSOR FLOWMTR RMARK: J:RLAY R:HATING SYSTM T:TRIAC AC 240V/60Hz Technical Data Model ADV120FDCH ADV150FDCH ADV180FDCH ADV210FDCH ADV240FDCH ADV270FDCH Phase 1 1 1 1 1 1 Voltage V 240 240 240 240 240 240 Wattage kw 12 15 18 21 24 27 Max. Amp. load A 50 63 75 88 100 113 Min. required circuit breaker A 60 2 X 40 2x50 3 X 40 3 X 40 3 X 50 Min. wire size AWG cooper 8 2 X 8 2 X 8 3 X 8 3 X 8 3 X 8 Min. water flow to activate GPM / L/min. 0.85/ 3.2 0.85 / 3.2 0.85 / 3.2 0.85 / 3.2 0.85 / 3.2 0.85 / 3.2 Weight kg 3.6 5.3 5.3 5.5 5.5 5.5 Product Dimensions mm 385x260x93 385x260x93 385x260x93 385x260x93 385x260x93 385x260x93 Water connections NPT 1/2 3/4 3/4 3/4 3/4 3/4 Note: *suitable recognized strain relief means shall be provided when the product installed.

285mm 285mm Product Inner Structure MODL ADV120FDCH 260mm Display screen UP DOWN ON/OFF Display screen L1 L2 ADV150FDCH ADV180FDCH 260mm bottom case heating chamber control board Display screen UP DOWN ON/OFF Display screen Temp.sensor L1 L2 L1 L2 flowmeter Terminal blocks

285mm ADV210FDCH ADV240FDCH ADV270FDCH 260mm bottom case heating chamber control board Display screen UP DOWN ON/OFF Display screen Temp.sensor L1 L2 L1 L2 L1 L2 flowmeter Terminal blocks Installation Guideline The installation must be in compliance with the National lectrical Code, your local electrical and plumbing codes. 1. Make sure the appliance is intact, and the fittings are complete. 2. Please make sure the main power supply, water pressure, grounding condition, amp meter and wire reach the standard of installation requirement. 3. The appliance must be connected to properly grounded dedicated branch circuits of proper voltage rating. Ground must be brought to the ground at the circuit breaker panel. 4. This appliance MUST be permanently connected to the fixed circuit breaker. If you don t use the heater, please switch off the circuit breaker. 5. DO NOT install this appliance near flammable materials or a strong magnetic field. The unit must only be mounted in a VRTICAL position near by the water fittings. When installing new unit please connect water fittings and turn water on so water flows through unit before turning POWR ON. Installation Location & Method Fixed installation on the wall Locate an appropriate place on a section of wall as above mentioned.

Fig 1 Front and back of the appliance Fig 2 Remove screw which fixed the bracket on back of the appliance. Fig 3 Remove the bracket from the appliance Fig 4 Hold the back bracket hanger in position against the wall and mark the three mounting holes. Drill three holes of 6.00mm diameter, the distance between every two holes is 100mm. (Put plastic anchor in the hole, fix

the bracket on the wall. and secure the hanger using the screws supplied or an appropriate alternative method). Fig 5 Undo screws on appliance to remove the front cover, Carefully use hands to pull out the screen row line plug before removing the front cover.

Fig 6 Fix the appliance to the bracket which was nailed to the wall, Make sure the unit bracket is secured onto the back metal hanger correctly L1 L2 L1 L2 L1 L2 Fig 7 Connect the cable to the terminal blocks, please notice the guidance logo below the terminal blocks. ADV120FDCH will be connected to one circuit breaker, ADV150FDCH, ADV180FDCH, will be connected to two circuit breakers, ADV210FDCH, ADV240FDCH, ADV270FDCH will be connected to three circuit breakers. L1 L2 L1 L2 L1 L2 Fig 8 Please plug in the screen row line plug, then affix the front cover on appliance, screw in place.

Fig 9 install the rubber seal ring. Connect the water pipe to the water inlet and water outlet connections, please remember to Water connections 1. All water pipe must comply with national and applicable state and local water pipe codes. 2. The unit should be connected directly to the main water supply. Flush pipe with water to remove any debris or loose particles 3. It is required that 1/2 NPT water connections be used with model ADV120FDCH, use 3/4 NPT water connections with the following models ADV150FDCH, ADV180FDCH, ADV210FDCH, ADV240FDCH, ADV270FDCH 4. Please remember to install rubber seal rings at the connections. When all water connections are completed, check for leaks and take corrective action before proceeding. lectrical connection 1. All electrical work must comply with national and applicable state and local electrical codes 2. All units must be connected to a properly grounded dedicated branch circuit of proper voltage rating. 3. Before beginning any work on the electric installation, be sure that main breaker panel switch is OFF to avoid any danger of electric shock, all mounting and plumbing must be completed before proceeding with electrical hook-up. 4. ADV120FDCH can be connected to a single circuit, use a supply cable protected by a double pole breaker 5. ADV150FDCH, ADV180FDCH, require two independent circuits. Use two supply cables protected by two separate double pole breakers. 6. ADV210FDCH, ADV240FDCH, ADV270FDCH, require three independent circuits. Use three supply cables protected by three separate double pole breakers. 7. While feeding the cable to terminal blocks, please make sure the metal wire ends and the terminal blocks touch completely. Then tighten the screws to make sure there is full contact and the current can go through. Operation Instructions 1. Turn on the circuit breaker to bring electrical power to the unit. 2. Open water faucet for a few minutes until water flow is continuous and all air is purged from water pipes. The unit must be operated after the breakers are turned on. 3. After the unit is supplied with power, a beep sound can be heard and LD lights for 2 seconds, no other display, the appliance keeps standby. 4. Press to turn ON/OFF the appliance. When the unit is ON, LD displays actual water temperature of the

outlet. When the appliance is not operating, the screen will switch to the screen saver after 5 seconds. The display screen light will be off. Touch the screen, it will return to operating mode 4. Press and to adjust the outlet temperature. Temperature setting range is 30--52 C/ 86-125. If the unit has been paused, You may initially get a short burst of very hot water while you turn on again. Please run the water through for a few seconds to let the temperature settle down. Please check hot water with hand before you taking a shower. If the unit will not be used in winter, drain out water completely so that the heater will not FRZ. Please periodically clean inlet strainer and the shower to keep a free water flow. 5, Press to convert the temperature display between fahrenheit degree and degree celsius. 6. There is a automatic memory function to avoid repetitive operation, while you turn on the appliance, the default set temp. will be the same as last time it was set. Trouble-shooting Problems Possible Causes Corrective Actions 1. Inlet and outlet fittings leaking A. Fittings are not tight B. Rubber washer worn-out A. Tighten fittings. B. Change rubber washer. 2. LD no signal A. Power not connected. B. LD damaged. A. Connect power to the unit. B. Change LD. 3. Functional keys not working A. No water out from shower. B. Water pressure too low. C. Key or PCB damaged. A. Open valve to get water. B. Open valve to get pressure. C. Change key or PCB. 4. Water too hot A. Too high temperature set. B. Water flow too little. A. Set a lower temperature. B. Open valve more. 5. Water too cold A. Low temperature set. B. Water flow too much. A. Set a higher temperature. B. Reduce water flow. 6. Outlet gets water smaller and smaller. Inlet strainer or shower clogged. Clean strainer and shower. 7. LD displays 1 Outlet temp. is over 67 /153 A, Reduce the temperature B, Turn up the water flow 8. LD displays 3 Temperature sensor failure Please contact with your local dealer 9. Display overload Inlet water flow is too high. Reduce the inlet water flow 7 and 8 should only be performed by qualified electrician. The person who initially installed the unit is the best one to contact for help.

Normal Maintenance Note: Do not attempt to repair this water heater yourself. Call a service person for assistance. Always turn off all power supply to the unit. Turn off all circuit breakers supplying power to the appliance *please note some units are connected multiple circuit breakers. Turn OFF ALL WATR SUPPLY and ALL POWR SUPPLY. This unit does not require any regular maintenance. However, to ensure consistent water flow, it is recommended to follow the following procedures. 1. Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head. 2. There is a built in filter screen at inlet connection which should be cleaned from time to time. Please turn off the water flow before doing this.