F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Similar documents
Integrated Automation Instrumentation & Terminal Devices

June Copyright Climatec

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Applications. Features & Benefits ULTRASONIC WATER METER

Residential Fire Meter

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

ANEMOMETER 4403-RF-BAT

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

TrueAlarm Analog Sensing

FCHM Hydromatic Pump Control Module

Electronic Flow Switches

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Accomplish Maximum Green Results in Commercial Buildings #

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Speed and Frequency Seite 1 von 7

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

for Drinking Water Systems

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

A. Detail drawing M1 Standard Chilled Water Schematic 1.03 DESCRIPTION OF THE PULLMAN CAMPUS CENTRAL CHILLED WATER LOOP SYSTEM:

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

University of Delaware

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Sitron s CF Line of Flow Switch Monitors

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

TR FLEXMAG 4050 C Electromagnetic flow meter for single use processes

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Integrated Process Solutions. Series 49. Thermal Management System

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Automatic Isokinetic Sampler ST5

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Domestic Pump Condensate Transfer Equipment

AS950 REFRIGERATED SAMPLERS

Bosch Greentherm Series

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Ramsey Motion Monitoring Systems

HIGH CAPACITY PRODUCT LINE

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

SECTION PACKAGED HEAT TRANSFER SYSTEM

PARTICULATE EMISSION MONITORING

WASTEWATER Online UV%Transmission Analyzer

Model gffoz Process Ozone Sensor (In-Line)

PRODUCT CONFORMITY CERTIFICATE

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Section B Field Instruments

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

MagMaster MFE flowmeters feature an innovative multifrequency

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Modular Supply Make-Up Air Unit

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

HIGH CAPACITY PRODUCT LINE

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Glass Tube Variable Area Flowmeter

When reliability is vital. Alemite Carbon Shield TM Systems deliver

TYPE VL/VLS VERTICAL INLINE PUMPS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

EVMSU - Vertical Multistage Pumps. Product Catalog

Acrison. Model 515 Polyelectrolyte Preparation Module. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

Custom Design TYPE CS

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Wind vane 425. Datasheet. Version 1.1

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

VIEW. Matters. Magnetic Level Indicators Series. with. indicator. The. 200º viewing angle. 200º viewing angle

PIONEERS IN AIR VACUUMS

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

TrueAlarm ES Analog Sensing

Electronic Pressure Digest. Pressure and Temperature Transmitters

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

TrueAlarm Analog Sensing

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

SENTRA Series Water Unit

E340 BOILER CONTROL INSTALLATION MANUAL

Technical Publication. Monitor Your Pump for Process Efficiency By Jim Delee, Sr. Member Technical Staff, Fluid Components International

TIMER CONTROLLED DRAINS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

TECHNICAL. Series 18. Pump Packages

Lynergy Comfort Control SCR Electric Heater Application Guide

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Inductive Conductivity

5. CONDENSATE PUMPS/UNITS

Taco 00 Series Cartridge Circulators

PRODUCT CONFORMITY CERTIFICATE

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Series 5000 Hydrazine Analyzer Model 60002

Transcription:

ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to order and individually wet-calibrated. And yet, the innovative insertion style design makes it affordable to fully instrument the entire plant providing the real-time flow data critical to improving performance and efficiency. In addition, these meters can be installed with no interruption to existing services during installation. F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger. STREAMLINED SENSOR HEAD AND SLENDER STEM allow for hand insertion of the meter while under pressure. INTEGRAL HOT-TAP DESIGN is standard for all insertion flow meters and allows insertion and removal without interrupting flow. Meters are hand-insertable. No special installation tools are required. PATENTED TURBINE ROTATION SENSING SYSTEM translates turbine rotation into electronic impulses without the need for magnets that impede rotation and attract rust. Hot Tap Adapter LOW MASS TURBINES require very little energy to rotate. This makes them responsive to small changes in flow and significantly enhances their low flow performance. PRECISION SHAFT & BEARING SYSTEM incorporates sapphire thrust and axial bearings installed on highly polished tungsten carbide shafts. When coupled with the low mass turbines, this system virtually eliminates shaft and bearing wear even after many years of continuous service.

F-1200 Series Dual Turbine Meters Provide all the features of the F-1100 series single turbine meters, plus significantly improved accuracy in limited straight pipe runs. By averaging the speed of rotation of two turbines with opposite helixes, the F-1200 minimizes the effect of swirl, the most common flow distortion caused by pipe bends and elbows. This makes the F-1200 more forgiving when installed in cramped central plant piping systems. Suitable for pipe sizes 2 ½ and larger. FOUR STANDARD MODELS TO MEET YOUR NEEDS F-1100 and F-1200 series flow meters are available in four different models, each specifically designed to interface with your building control system. Each is also provided with a dedicated output signal suitable for use with ONICON display modules or BTU meters. F-1100 / F-1200: FREQUENCY OUTPUT Frequency output versions of the meter provide a single linear 0-15 VDC square wave signal that is proportional to flow. This high resolution output signal (up to 300 Hz) is specifically designed to interface with ONICON peripheral devices such as BTU meters and displays. F-1110 / F-1210: ANALOG OUTPUT These models provide two factory calibrated analog signals for reporting flow rate data; an active 4-20 ma output and a 0-10 VDC output. This meter also has a frequency output. F-1111 / F-1211: ISOLATED ANALOG OUTPUT These models provide the same output signals as the F-1110 / F-1210 models, except that the analog signals are electrically isolated from input power and earth. This meter also has a frequency output. F-1130 / F-1230: SCALED OUTPUT The F-1130 and F-1230 provide a precision scaled pulse output for totalizing flow. The output is scaled to one pulse per a specific unit volume; i.e. one pulse per 10 gallons, or one pulse per 100 liters, etc. The output is an electrically isolated solid state dry contact switch. This meter also has a frequency output.

APPLICATIONS Chilled water, hot water and closed loop condenser water for HVAC Pumped steam condensate Domestic / municipal water Process water and water mixtures GENERAL SPECIFICATIONS SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) ACCURACY ± 0.5% of reading at calibrated velocity ± 1% of reading from 3 to 30 ft/s (10:1 range) ± 2% of reading from 0.4 to 20 ft/s (50:1 range) PRESSURE DROP Less than 1 psi at 20 ft/s in 1 ½ pipe, decreasing in larger pipes and lower velocities MAXIMUM OPERATING PRESSURE 400 psi MAXIMUM LIQUID OPERATION TEMPERATURE Standard - 180 F continuous, 200 F peak Optional - 280 F continuous, 300 F peak SUPPLY VOLTAGE 24 ± 4 VAC / VDC OPERATING RANGE FOR COMMON PIPE SIZES F-1100 / F-1200 SERIES 0.17 to 20 ft/s, ±2% accuracy begins at 0.4 ft/s Pipe Diameter Flow Rate GPM Nominal Pulses Per Gallon 1 ¼ 0.8-95 191 1 ½ 1-130 155 2 2-210 79 2 ½ 2.5-230 57 3 4-460 37 4 8-800 21 6 15-1,800 8.8 8 26-3,100 5.1 10 42-4,900 3.2 12 60-7,050 2.3 14 72-8,600 1.8 16 98-11,400 1.4 18 120-14,600 1.1 20 150-18,100 0.86 24 230-26,500 0.58 30 360-41,900 0.37 36 510-60,900 0.25

Turbine Flow Meter Application Guide APPLICATION LOCATION & PIPE SIZE MODEL (SIGNAL TYPE) REQUIRED OPTIONS DISPLAY Chilled Water Hot Water (280o F) Condenser Water (closed loop) Make-up Water HVAC APPLICATIONS ¾ -1 (0.8 to 38 gpm) F-1310 (analog)* None 1 ¼ - 2 F-1110 (analog) 316 SS for HW over 250o F 2 ½ and up with developed flow 2 ½ and up with undeveloped flow due to short pipe runs F-1110 (analog) F-1210 (analog) 1 ¼ - 2 F-1130 (pulse) 316 SS for non-metallic pipe Check project specifications for required features. System-10 Domestic Hot Water Domestic Cold Water Choose single or dual based on straight pipe run F-1130 or F-1230 (pulse) Steam Condensate Typically small pipes F-1130 or F-1330 (pulse) Boiler Feed Water (to 280o F) Municipal Water Process Water Process Cooling Process Cooling Low Conductivity Typically small pipes 1 ¼ and up with developed flow 2 ½ and up with undeveloped flow due to short pipe runs F-1130 (pulse) MUNICIPAL WATER F-1111 (iso-analog) F-1211 (iso-analog) PROCESS APPLICATIONS 1 ¼ - 2 F-1111 (iso-analog) 2 ½ and up with developed flow 2 ½ and up with undeveloped flow due to short pipe runs 1 ¼ and up with developed flow F-1111 (iso-analog) F-1211 (iso-analog) F-1111 (iso-analog) 316 SS wetted metal components are required for insertion type meters in these applications. D-100 NSF61 Version D-100 316 SS wetted metal components typically required. Requires 316 SS welded construction and low conductivity option. D-100 * F-1300 series are inline turbine meters. Available Peripheral Equipment Accurate energy measurement is essential for managing complex central energy plants, and ONICON System-10 BTU Meters provide that accuracy. ONICON displays turn any flow meter into a complete flow measurement station. Options range from simple wall mounted indicators to sophisticated network interface options like the D-100. System-10 D-100 D-1200

Flow Meter Specifications for Central Energy Plant Applications FLOW METER SPECIFICATION FOR: Chilled Water, Heating HW, Closed Loop Condenser Water PROVIDE AN ONICON MODEL F-1210 DUAL TURBINE FLOW METER complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. The flow meter shall have two contra-rotating axial turbines, with electronic impedance-based sensing and an averaging circuit to reduce measurement errors due to swirl and flow profile distortion. Wetted metal components shall be nickel-plated brass (unless optional 316 SS is otherwise specified). Optional 316 SS construction is required for HW applications operating over 250º F, and for any application in non-metallic pipe. The maximum operating temperature shall be 280º F, 300º F peak. Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within ± 0.1% and traceable to N.I.S.T.*. The manufacturer s certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 0.5% of rate at the calibrated velocity, within ± 1% of rate over a 10:1 turndown (3.0 to 30 ft/s) and within ± 2% of rate over a 50:1 turndown (from 0.4 to 20 ft/s). The flow meter shall include two integral analog output(s), 4-20 ma, 0-10 V, (Optional 0-5 V). The flow meter shall be covered by the manufacturer s two-year warranty. Optional Btu Meter: Provide an ONICON System-10 BTU Meter. The Btu meter shall provide the following points both at the integral LCD and as outputs to the building control system: energy total, energy rate, flow rate, supply temperature and return temperature. Note to engineer regarding open loop condenser water applications: ONICON recommends the model F-3500 insertion electromagnetic type flow meter for open loop applications. FLOW METER SPECIFICATION FOR: Make-up Water, Pumped Condensate, Boiler Feed, Boiler Blow-down PROVIDE AN ONICON MODEL F-1130 TURBINE FLOW METER complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. Turbine rotation shall be detected by electronic impedance-based sensing (non-magnetic). For pipe sizes 2 ½ and larger with less than 30 straight pipe diameters available, provide an ONICON Model F-1230 flow meter, with two contra-rotating axial turbines, and an averaging circuit to reduce measurement errors due to swirl and flow profile distortion. Wetted metal components shall be 316 SS. The meter shall be rated for maximum operating temperature of 280º F, 300º F peak. Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within ± 0.1% and traceable to N.I.S.T.*. The manufacturer s certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 0.5% of rate at the calibrated velocity, within ± 1% of rate over a 10:1 turndown (3.0 to 30 ft/s) and within ± 2% of rate over a 50:1 turndown (from 0.4 to 20 ft/s). The flow meter shall include an integral isolated dry-contact switch output that is factory scaled to meet the frequency requirements of the building management system based on application-specific flow rates. The flow meter shall be covered by the manufacturer s two-year warranty. Optional Flow Display: Provide a D-100 Flow Display with network interface for local or remote indication of flow rate and total. Note: When optional flow display is specified, use flow meter models F-1100 and F-1200 in lieu of F-1130 and F-1230. Note to engineer regarding pumped condensate and boiler blow-down: Pipe must be equipped with back-flow prevention, and it must be completely filled. This technology is not suitable for gravity flow condensate return systems. * National Institute of Standards and Technology 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 0468-6 www.onicon.com sales@onicon.com 04-18