Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

Similar documents
Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Manual Supplement. Product/System Title: Premium Clean Room Monitor. Contents of this manual supplement include:

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

SUREFLOW ROOM PRESSURE CONTROLLER MODELS BAC

SUREFLOW ADAPTIVE OFFSET CONTROLLER MODELS BAC

RPM1600 Series Room Pressure Monitors

PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

Critical Environments. Model FHC50/FHM10. Fume Hood Controller/Monitor. Operation and Service Manual. P/N , Revision B October 2010

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30

PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

PRESSURA ROOM PRESSURE MONITOR MODELS 8630-SM 8630-PM

Digital Precise Air Control - DPAC

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

MicroTech Self-Contained Air Conditioning System

Analog Room Pressure Monitor RPC Series

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

Metasys Integrator TITUS Application

ASHRAE Guideline 36 Advanced HVAC Control Sequences

DACC - NMDA BUILDINGS


Rev UltraSite User s Guide BCU Supplement

Rosemount 3051S MultiVariable Transmitter

I/O ZONE 560/583 USERS GUIDE

OVEN INDUSTRIES, INC.

SEQUENCE OF OPERATIONS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Tri-Stack Smart System

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

2017 products.koer.com Page 1 of 14

Metasys Integrator Cleaver-Brooks Application

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Verasys System Operation Overview Technical Bulletin

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

1.0 Digital Controller

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Metasys Integrator Airflow Application

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MARVEL MINI HVAC MICROPROCESSOR CONTROLLER

York 25-Ton VAV Rooftop Unit

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

BACnet MODBUS N2 LON Description Type Point Description Name # Object Type Register Type ID SNVT # Name SNVT Read Only

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Product Manual SZ1145

MicroTech Unit Ventilator

Toxic Gas Detection. Model F12. Toxic Gas Detection

Instruction, Operation, and Maintenance: Controls Software Versions: R37+

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

VCB-X Modular Service Tool Technical Guide. VCB-X Controller Code: SS1051 Version 2.0 Requires Service Tool Code: SS1041 Version 2.

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Multiview Monitor / Controller

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

InfinityPro. Control System for Rapid Engineering, LLC Air Handlers. User, Operation & Troubleshooting Manual

Product Manual SZ1144

Feature Summary. I. System

Installation, Operation, and Maintenance Manual

Sequence of operation

MARVEL PREMIUM HVAC MICROPROCESSOR CONTROLLER

CLEANROOM MONITOR CR3A Network - Installation Instructions

RSMV Technical Guide

- Data Brochure Universal Reset Module 423

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

MicroTech Rooftop/RMC

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions

Rev B, 9/2/2009. Kodiak Chiller Overview

IPCM INTELLIGENT PRESSURE CONTROL MODULE INSTALLATION AND OPERATIONS MANUAL FOR CONSTANT PRESSURE CONTROL APPLICATIONS VERSION 1.0

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

BACnet Programmable TEC (PTEC) VAV Chilled Beam with Demand Control Ventilation (CO2) and Floating or Analog Output Owner s Manual

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Control board manual. Version Control adjustment and operation instructions

Installation & Calibration Guide

MARVEL MINI HVAC MICROPROCESSOR CONTROLLER

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

200i/KN2, KN4 Firmware Revision Sheet

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

MVE TS Controller (Touch Screen)

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers)

Reference Guide for Microprocessor Controller

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Accuracy by Design Products for the HVAC Professional

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Electro-Sentry. Users Manual

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

- Data Brochure Universal Reset Module 422

Transcription:

Model Number: Product/System Title: 8635-ST Static Pressure Controller Contents of this manual supplement include: 1) Sequence of operation 2) Description of new software items 3) Deleted software menu items 4) Menu structure drawing 5) Wiring diagram Page 1 of 9 Released 2/13/02

Sequence of Operation The Model 8635-ST unit is a static pressure controller primarily to be used to control the static pressure in a duct. This controller measures the duct static pressure, and modulates a damper or VFD to obtain a desired pressure setpoint. Page 2 of 9 Released 2/13/02

Description of New Software Items Menu Item SETBACK SETBACK LOW ALM Description The SETBACK item is used to set the static pressure setpoint under setback conditions. This is a second control setpoint, activated by the switch input or digital communications. The SETBACK LOW ALM item sets a setback or second low pressure alarm set point. A setback low alarm condition is defined as when the duct static pressure falls below the SETBACK LOW ALM set point. This item is enabled when the SWITCH INPUT contacts closure, pins 11 and 12, is closed, or the RS-485 communications send the appropriate command. SETBACK HIGH AL The SETBACK HIGH AL item sets a setback or second high pressure alarm set point. A setback low alarm condition is defined as when the duct static pressure rises above the SETBACK HIGH AL set point. This item is enabled when the SWITCH INPUT contacts closure, pins 11 and 12, is closed, or the RS-485 communications send the appropriate command. MINIMUM SETPOINT TRANSDUCER OUTPUT NOTE: The MINIMUM SETPOINT item is used to set the minimum damper position or VFD output as a percent. This value can range from 0% to 100%, with a default of 0%. The TRANSDUCER OUTPUT item is used to set the transducer output voltage range. This item can be set at either 0-10V or 0-5V. For transducers with a 2-10V output, the 0-10V setting can be used. Similarly, for transducers with a 1-5V output, the 0-5V setting can be used. Page 3 of 9 Released 2/13/02

MAX PRESSURE SENSOR ZERO CONTROL SIG The MAX PRESSURE setting is used to set the upper limit of the pressure transducer. This item can be set from 10 Pa to 5000 Pa (0.10 inches of water to 20.00 inches of water). The default value is 500 Pa (2.0 inches of water). The SENSOR ZERO item is used to establish the pressure sensor zero pressure point. A zero point needs to be established prior to using the pressure measurement output. The 8635-ST needs to have a SENSOR ZERO established on initial setup. This procedure is detailed in the CALIBRATION section of the model 8635-C manual, under FLOW STATION PRESSURE TRANSDUCER ZERO The CONTROL SIG item displays the current control output signal as a number between 0 and 255. To test the control output, press the / keys until either 0 or 255 shows on the display. Note the position of the static pressure control damper. If display reads 0, press the key until 255 is shown on the display. If the display reads 255, press the key until 0 is shown on the display. The damper should have changed from the full open to the full closed position, or from the full closed to the full open position. If not, see hardware section Control system is not controlling in the model 8635-C manual. Page 4 of 9 Released 2/13/02

Deleted Software Menu Items The following items have been replaced or eliminated in the 8635-ST: SETPOINTS MENU ALARM MENU CONFIGURE MENU CALIBRATION MENU DIAGNOSTICS MENU REM SETPOINT VENT MIN SET TEMP MIN SET TEMP LOW TEMP HIGH REM LOW ALM REM HIGH ALM MIN SUP ALM DOOR DELAY EXH DUCT AREA SUP DUCT AREA FLO STA TYPE TOP VELOCITY ROOM VOLUME SENSOR SPAN EXH FLO ZERO SUP FLO ZERO ELEVATION CONTROL SUP CONTROL EXH SENSOR INPUT EXH FLOW IN SUP FLOW IN TEMP INPUT Page 5 of 9 Released 2/13/02

Menu Structure Manual Supplement SETPOINTS ALARM CONFIGURE CALIBRATION SETPOINT SETBACK MINIMUM SETP LOW ALM HIGH ALM SETB LOW ALM SETB HIGH AL ALARM RESET AUDIBLE ALM ALARM DELAY MUTE TIMEOUT DISPLAY AVG UNITS TRANSD. OUTP MAX PRESSURE SENSOR ZERO CONTROL INTERFACE DIAGNOSTICS SPEED SENSITIVITY CONTROL SIG OUTPUT MODE KC VALUE TI VALUE TD VALUE NET PROTOCOL NET ADDRESS CONTROL SIG ANALOG OUT SENSOR INPUT SWITCH INPUT LOW ALM REL HIGH ALM REL Figure 6: Menu Items - Model 8635 - ST Controller Page 6 of 9 Released 2/13/02

Wiring Diagrams Manual Supplement MODEL 8635 - C - STA STA STATIC CONTROL OPTION WIRING DIAGRAM - ELECTRIC 21 22 23 24 25 26 Page 7 of 9 Released 2/13/02

MODEL MODEL 8635 8635-ST - C - STA STATIC CONTROL OPTION WIRING DIAGRAM - ELECTRIC 21 22 23 24 25 26 Page 8 of 9 Released 2/13/02

MODEL MODEL 8635 8635-ST - C - STA STATIC CONTROL OPTION WIRING DIAGRAM - PNEUMATIC 21 22 23 24 25 26 Page 9 of 9 Released 2/13/02