PARTNER PRESENTATION 2016
FIRESCREEN - FEEL SAFE Feel safe with Firescreen Firescreen fire curtains ensure direct compartimentalisation in case of fire and prevent fire and smoke from spreading.
FIRESCREEN - FEEL SAFE Firescreen s primary goals are: Protect people Limit damage to buildings and property Avoid interruption in business activity
FIRESCREEN - FEEL SAFE All models: Comply with the requirements of building regulations Are tested in accordance with European EN 1634-1 standard Meet EN 13501-1 regulations reaction to fire
FEATURES Compact Easy to install Lightweight
BENEFITS Gives architects greater design freedom Excellent alternative to classical systems Provides fire protection in accordance with EU standards Is a high quality product
HOW IT WORKS Open position Fire- or smoke signal Self closing
PRODUCTRANGE Firescreen Flame Firescreen Radiation Firescreen Temperature Firescreen Smoke
FIRESCREEN - FLAME Firescreen Flame prevents fire from spreading by containing it. It is based on a robust concept which contains flames effectively. Firescreen Flame fire curtains comply with 1 criteria: E Flame containment in order to maintain structural integrity
REFERENCES Firescreen Flame
FIRESCREEN - RADIATION Firescreen Radiation fire curtains ensure direct compartmentalisation (integrity) and limit heat radiation. Heat radiation: Is a health risk for people Can cause easily flammable materials to ignite Passing through windows and other openings in the façade can cause a fire to spread
FIRESCREEN - RADIATION Firescreen Radiation fire curtains comply with 2 criteria: E Flame containment in order to maintain structural integrity W Heat radiation limitation of a maximum of 15 kw/m² Reaction to fire classification: B-s1,d0
REFERENCES Firescreen Radiation
FIRESCREEN - TEMPERATURE Firescreen Temperature fire curtains offer the highest level of protection. The screens can be used for: Realization of an evacuation route Creating a route for fire fighting organizations As an alternative to building firewalls
FIRESCREEN - TEMPERATURE Firescreen Temperature fire curtains comply with 3 criteria: E Flame containment in order to maintain structural integrity W Heat radiation limitation of a maximum of 15 kw/m² I Thermal insulation from the temperature Reaction to fire classification: B-s1,d0
REFERENCES Firescreen Temperature Fire curtains with EI Fire classification
OPTIONS Powder coating Head Box Side Guides Smoke- and temperature detectors Warning lights and sounders Emergency push botton Detailed drawings
FIRESCREEN - SMOKE Firescreen Smoke curtains ensure a smoke barrier which will limit the movement of smoke and fire gasses. Firescreen Smoke curtains are: 120 minutes smoke resistant up to 600 C suitable for ventilating shafts in combination with smokeand/or heat extraction installations tested in accordance with EN 12101-1
REFERENCES Firescreen Smoke
INTERNATIONAL PROJECTS & REFERENCES Starbucks Göteborg (S) Fire curtains Peab Sverige Arbetsplats Malmö (S) Fire curtains Lusail Carpark Doha (QA) Smoke curtains Universität des Saarlands (D) Fire curtains Sky Key Zürich (CH) Fire curtains Proctor & Gamble Strombeek Bever (B) Fire curtains DM Portservice ApS Glumsø (DK) Fire curtains Amthaus Wien (S) Fire curtains Umbau Alterheim Winterthur (CH) Fire curtains Febelco Conveyors Warehouse Heusden-Zolder (B) Fire curtains Palsgaard Slot Juelsminde (DK) Fire curtains Redevco Korenmarkt Gent (B) Smoke curtains Coop Bygg Mix Øystese (N) Fire curtains Bergen Lufthavn Flesland (N) Fire curtains Arlanda International Airport Stockholm (S) Fire curtains
SERVICE & MAINTENANCE All Fire Safety equipment must be maintained in efficient working order Regular planned preventative maintenance ensures that any defects are found before a critical situation arises Failure to comply with any duty imposed by the law, or any notice issued by the enforcing Authority, is an offence and prosecutions are on the rise Easy money for the dealer!
RESTRICTIONS No installation to the ceiling, concerning all type of fire curtains No installation in wet- or humid environments No high frequency use of fire- and smoke curtains There should be limited draught in the room where the Firescreen fire- and smoke curtains are installed There should always be an alternative escape route/evacuation door(s) EI curtains should be installed on these four type of walls/mounting surfaces: - Brickwork; - Concrete wall, minimum 150 mm thick; - Aerated concrete blockwork wall, minimum 150 mm thick/ density 600 kg/m³; - Steel supporting construction, covered with fireproof plating.
THANK YOU FOR YOUR ATTENTION Zevenheuvelenweg 50 PO box 5036 5004 EA Tilburg The Netherlands T: +31 (0) 13 462 59 59 info@firescreen.com www.firescreen.com