Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Similar documents
DEMA 830 Laundry Master TM Installation Instructions

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

DEMA Nitro Express Ware Wash Chemical Dispenser

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

DEMA Nitro Ware Wash Chemical Dispensing

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

DEMA PROPORTIONER MODEL 167 & 167T INSTALLATION INSTRUCTIONS

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

ENCLOSED UNIT TECHNICAL MANUAL Items # &

INSTRUCTION MANUAL FOR DEMA CHEMASTER TM DM-813-LLL-1T, DM-813-LLL-2T, DM-813-DLL-1T and DM-813-DLL-2T

DEMA 844 Laundry Master Laundry Chemical Dispensing

DEMA CHEMASTER WAREWASH SYSTEM INSTALLATION AND OPERATIONS MANUAL

IMAGE V. Parts and Service Manual

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

DEMA TITAN II WAREWASH CONTROL T.812 & T.813 SERIES

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Harvey Chemiclave EC Series Sterilizers

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

REPLACEMENT PARTS MANUAL

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

REPLACEMENT PARTS MANUAL

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

DISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PolyMax H2-24 Dutch Bucket System

CREWMAN 20 ORB CREWMAN 28 ORB

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

P/N CC-100. Coolant Circulator. Operation manual

ICE/BEVERAGE DISPENSER

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Cool IR. Model C104 - Cooling System. Instruction Manual

Installation Instructions for. OmniFount

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

1-866-PENNERS

MAXUM 5 5 Gallon Box Extractor

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Troubleshooting the MPH 24FP Series Pedestal Hydrant

UNIVERSAL 750 PRE-MIX DISPENSER

SINGLE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Manual Addendum For Dyna-Fog Hurricane ES

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

WAREMAX SERIES. Dosing Systems for Commercial Dishmachines. Contents. WAREMAX Series Dishwasher systems. 4 Priming and Delime Mode.

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Power Eagle 1016/1020. Self Contained Carpet Extractor. Operator and Parts Manual

BUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Auto Top-Off & Ultra-Precise Liquid Level Controller II

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

PARTS LIST RALLY 220 SAVE THESE INSTRUCTIONS

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN

For more Parts Information:

Operator and Parts Manual Nu-1600 Burnisher, Belt Drive Nu-2000 Burnisher, Belt Drive

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

HD-26, HD-36, HD-48 Heated Displays

Installation Instructions for. OmniFount

Model Series Series

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Sacksafoam Heli-Case Operations Manual - Version A Issue Date: April 2017 PLEASE READ BEFORE USING


Please Read and Save These Instructions.

VANGUARD 245 POST-MIX DISPENSER

Drain Cleaning Machine K-39

SELF-CONTAINED POWER MISTER

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

MAXUM Gallon Box Extractor

Instruction Manual. Cheese Warmer with Pump

NHR-25 Feed Hopper with Agitator

CAUTION . CRACKED. SCRATCHED. BOILED DRY. HEATED WHEN EMPTY. USED ON HIGH FLAME. OR EXPOSED ELECTRIC FAILURE TO COMPLY RISKS INJURY

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

STAND ALONE DRYER BASE. Parts Manual

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Parts and Service Manual

Knight Trak II Instruction Manual

On/Off push button locks for filling up mop buckets and automatic scrubbers.

ILLUSTRATED PARTS LIST ENDURO VALVE

MK-660 tile saw OWNER'S MANUAL PARTS LIST & OPERATING INSTRUCTIONS

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Service Parts for models UF424 and UN324

Frontier. Self Contained Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (09-99)

Pump Out Vacuums Polyethylene & Steel

Repair Parts List DISHWASHER MODEL NUMBER MDC4000AWX. When requesting service or ordering parts, always provide the following information:

FIBERPRO SPOTTER CARPET. 3.5 Gallon Carpet Spotter Machine. Operator and Parts Manual E

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

CURTIS Gemini 12 Brewer

Transcription:

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Overview The DEMA Easy Dose is a simple and reliable chemical delivery system. Easy Dose features an electronic control system coupled with up to two electric diaphragm pumps for precise injection of chemical in a variety of applications. Additionally, the system can be coupled with electronic flow meter technology allowing Easy Dose to automatically adjust chemical injection rates based on water line flow conditions. Warnings Installation of DEMA products must meet all applicable electrical codes and regulations established by national, city, county, parish, provincial or other agencies. It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation. For questions, contact a certified electrician. All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS. I 1201 Page 1 of 14

Easy Dose Models Easy Dose can be ordered as a complete system that includes the control unit and the pump unit or control unit and pump units can be ordered individually. The Easy Dose Control module can support 2 pump modules. Each pump module can be individually controlled with a speed control pot. 85AC or 85DC Models are Complete Systems include the control and pump units, flow meter option o If a second pump is required order an 8512 unit 8511 Models are Control Units choose AC or DC o AC accepts 115/230VAC 50/60Hz (comes wire with 115VAC power cord with plug) o DC accepts 12VDC designed to be operated with 12VDC mobile equipment battery (car battery) 85AC.DP2F Complete System Control & Pump Unit Flow Meter Option Flow Meter (Analog) Pump DP2 = 12VDC Diaphragm Pump (1.8GPM open flow) Base Pump Unit (Up to 2 for each control base unit 8510 or 8511) 85AC = 8511.AC Control Unit 115/230VAC Main Power 85DC = 8511.DC Control Unit 12VDC Main Power This model number includes both the control unit and a pump unit in a single shipping package. A second pump unit can be added by ordering a 8512 pump unit shipped in a second package. 8511.AC Control Unit Control Base Unit 8511.AC = UCI with Power Supply 115/230VAC Main Power 8411.DC = UCI w/o Power Supply 12VDC Main Power 8512.DP2F Pump Unit Flow Meter Option Flow Meter (Analog) Pump DP2 = 12VDC Diaphragm Pump (1.8GPM open flow) Base Pump Unit (Up to 2 for each control base unit 8511) I 1201 Page 2 of 14

Packing Kit List The following installation kit parts are included with the Easy Dose. The 85AC and 85DC models include an 8511 and 8512 module. Kit Parts with 8511.AC & 8511.DC Part Number Qty Description 85.109.1 3 Strain Relief (for installing sensor and float switch cables) 58.400.2 3 Nylon Nut (used to mount 85.109.1 strain relief) Kit Parts for 8512 Part Number Qty Description 85.127.1 1 Quill Chemical Injection Fitting (water/irrigation line injection point) 25.115 1 3/8" OD x 20ft LDPE Tubing (for pump discharge to quill) 85.132.1 1 3/8" ID x 20ft PVC Tubing w/strainer (for chemical reservoir to pump inlet) 85.118.1 1 Float Switch Assembly (for shutting off system when chemical reservoir is empty) 76.2.17 1 Tubing clamp (used to secure 85.132.1 tubing to pump inlet fitting) 85.134.1 1 3/8" Barb x 1/2" Stem (used at inlet of pump to connect 85.132.1 tubing) 85.133.2 1 1/2" JG x 1/2" Stem elbow (used to configure a right angle connection at inlet of pump) 85.133.1 1 3/8" JG x 3/8" Stem elbow (used to configure a right angle connection at outlet of pump) 81.16.5 20 Tie Wraps (for securing tubing and cables) 8512.DP2F only (the following is packed with the 8512 kits parts) Part Number Qty Description 85.128.1 1 Flow Meter sight glass/analog (Optional flow meter to determine chemical injection rate) 85.125.1 2 1/2" Mounting Clamp (for mounting 85.128.1 flow meter to wall/vertical surface) Product Specifications Main Power Requirement Control Board Power Pump Motor Output Connection at Control Board Flow Meter Technology Control Connection Float and Flow Switch Connections Power Supply Enclosure Material Environmental Rating Control Module Weight Pump Module Weight Usage Location Easy Dose Product Specifications 115/230VAC 2A/1A 50/60Hz 12VDC 12VDC 10A per pump connection 4 20mA/0 5V (electronic flow meter connection) Dry Contact 115/230VAC 50/60Hz input, 12VDC 25A output Polycarbonate UV Rated IP51 22lbs (10kg) 12lbs (5.4kg) Indoor/Outdoor mounted off ground I 1201 Page 3 of 14

Overall Size Control Module Pump Module Installation WARNING: INSTALLATION OF DEMA PRODUCTS MUST MEET ALL APPLICABLE ELECTRICAL CODES AND REGULATIONS ESTABLISHED BY NATIONAL, CITY, COUNTY, PARISH, PROVINCIAL OR OTHER AGENCIES. IT IS POSSIBLE THAT ELECTRICAL CODES AND REGULATIONS REQUIRE THAT A CERTIFIED ELECTRICAL CONTRACTOR OR ENGINEER PERFORM THE ELECTRICAL INSTALLATION. FOR QUESTIONS, CONTACT A CERTIFIED ELECTRICIAN. ALL ELECTRICAL POWER MUST BE TURNED OFF TO BUILDING CIRCUITS AND ASSOCIATED EQUIPMENT AT ELECTRICAL SERVICE PANELS. LOCKOUT & TAG PROCEDURES MUST BE OBSERVED WHEN PERFORMING ELECTRICAL WIRING PROCEDURES. UNIT MUST BE GROUNDED (EARTHED). Note: Refer to Installation Diagrams on Page 6 & 7 1. Mount the control module and pump module on the wall using the metal brackets that are supplied with each unit. The brackets will space the units from the wall allowing proper ventilation. The following must be considered when picking the location to mount the modules: a. 8511AC Control Module Main power cord is approximately 10ft long. The power cord has an 115V plug, but this can be cut off and the system can be wired to 115/230VAC. The power supply will automatically switch to 115V or 230V. b. 8511DC Control Module Main power cord is approximately 10ft long and has alligator clamps that are designed to connect to a mobile equipment battery (car/truck battery). c. The 8512 pump module has a 10ft long cable that is wired to the 8512 control module. d. The 8512 pump module includes 20 feet each of inlet tubing (1/2 OD), and outlet tubing (3/8 OD). Using chemical lines longer than 20 feet will result in reduced performance. The chemical reservoir and injection point at irrigation line must accommodate the 20ft of inlet and outlet tubing. Tubing can be shortened. I 1201 Page 4 of 14

e. The 8512 pump module chemical tube inlet should be mounted no more than five feet above the bottom of the chemical tank to ensure proper chemical draw. 2. Connect the 8512 pump module cable to the control module. a. Route the cable through one of the cord strain reliefs at the bottom of the 8511 control module. b. Use the Pump Output 1 on control board for pump 1, and if using a second pump, Output 2 on control board for pump 2. Black to negative, white to positive. c. Pull a couple inches of the pump cable into the control enclosure to remove the stress of the electrical connection to the control board. Tighten the nut on the strain relief to secure the pump cable. 3. Install the pump pickup tubing between the chemical reservoir and the pump inlet. The pickup tubing is 3/8 ID with a strainer fitted at one end. The end with the strainer will be installed at the chemical reservoir. a. Connect the 3/8 barb x ½ stem fitting (85.134.1) to the pump inlet by pushing it on to the ½ push on fitting at pump inlet (left side). b. Slip the hose clamp (76.2.13) over the end of the 3/8 ID pickup tubing without the strainer. c. Slide the tubing on to the barb fitting and tighten the hose clamp to secure the chemical pickup tubing to pump inlet. i. The ½ Push on x ½ stem right angle fitting (85.133.2) can be added to direct the tubing connection at a right angle if necessary. The right angle fitting may be helpful when there is limited space around the pump module. d. Route and secure the tubing to the chemical reservoir. Use tie wraps to secure the tubing. To assure optimum pumping performance the chemical inlet tubing must not exceed 20 feet (tubing can be shortened). The tubing should be secured so the strainer is resting on the bottom of the chemical reservoir. 4. Install the pump discharge tubing between the pump outlet and the irrigation line. The discharge tubing is 3/8 OD tubing. a. Connect the discharge tubing to the outlet connection (right side) of the pump module by pushing it into the 3/8 push on fitting at the pump outlet. i. The 3/8 Push on x 3/8 stem right angle fitting (85.133.1) can be added to direct the tubing at a right angle if necessary. The right angle fitting may be helpful when there is limited space around the pump module. b. Route the tubing to the irrigation line injection point. To assure optimum pumping performance the chemical discharge tubing should not exceed 20ft (tubing can be shortened). c. Connect the discharge tubing to the irrigation line using the quill fitting (85.127.1). i. The quill fitting has a ½ male tapered pipe thread. It may be necessary to use a pipe bushing/adapter to accommodate the ½ pipe thread (see Quill Fitting Diagram C). 5. Connect the optional 85.128.1 analog flow meter in line with the discharge tubing. a. The flow meter must be mounted vertically. b. Simply cut the discharge tubing at the desired location. c. Mount the flow meter vertically using the ½ mounting clamps (85.125.1). d. Connect the end of the tubing from pump to the flow meter by pushing the tubing into the 3/8 push on fitting at the bottom/inlet of the flow meter. I 1201 Page 5 of 14

e. Connect the end of the tubing that is going to the quill inlet fitting by pushing the tubing into the 3/8 push on fitting at the top/outlet of the flow meter. 6. Install the chemical reservoir float switch. a. Route the float switch cable through one of the cord strain reliefs at the bottom of the 8511 control module. b. Wire the float switch to the control board at float switch input 1 for the pump 1 and float switch input 2 for pump 2. Each terminal for the float switch should have a wire connected. Wires can be connected to either terminal (no polarity required). c. Enable the float switch function by removing the float switch jumper. The jumper can hang on one of the pins so that it is not misplaced. d. Route the float switch and cable to the chemical reservoir. Secure using tie wraps. e. Install the float switch in the chemical reservoir using the instructions that are included with the float switch. f. It is good practice to test the float switch for proper operation. i. Pump should run when liquid in chemical reservoir is above the pickup tube strainer. ii. Pump should not run when the liquid in chemical reservoir is at or below the pickup tube strainer. Installation Layout Diagram A Bleed Valve (release air during priming) I 1201 Page 6 of 14

Control Board Diagram B Pump Speed Control Pot 1 Pump Speed Control Pot 2 DIP Switches and Diagram 15A Fuses Float & Flow Switch Jumpers + - Main Power + - Pump 1 + - Pump 2 Float Switch 1 Float Switch 2 Flow Switch Flow Meter (4 20mA) Quill Installation Diagram C Valve for bleeding system during priming process. 3/8 OD tubing can be routed back to chemical reservoir Pipe adapter(s) may be required to fit the quill to the irrigation line I 1201 Page 7 of 14

Optional Equipment Flow Switch A flow switch can be added to detect if water is flowing through the irrigation line. This would be used to start or stop the Easy Dose based on irrigation line flow. DEMA DOES NOT OFFER A FLOW SWITCH and the flow switch will need to be ordered from an irrigation or plumbing component supplier. 1. The flow switch needs to be normally open. This means that when water is flowing through the irrigation line, the switch will close and enable the Easy Dose to operate. 2. The flow switch needs to be installed upstream from the chemical injection point (quill). 3. Install a cord strain relief (85.109.1) and backing nut (58.400.2) to the bottom of the control panel (both parts are supplied in the control module kit pack). a. Remove one of the hole plugs in the bottom of the control enclosure. b. Install the cord strain relief through the hole. The cord strain relief should be installed on the outside of the control enclosure. The nut is used to clamp the cord strain relief inside the control module enclosure. c. Route the wiring of the flow switch through the strain relief cord grip. d. Connect the flow switch wiring to the flow switch input terminals. No polarity is required. e. Remove the flow switch input jumper from the two pins and hang on one pin to store the jumper. Keeping the jumper on two pins will not allow for proper flow switch operation. f. Pull a 2 to 3 extra inches of the flow switch wiring into the control enclosure and tighten cord grip to secure the wiring. Flow Meter An electronic flow meter can be added to detect the flow rate of the irrigation line. The electronic flow meter will automatically control the chemical injection rate based on water flow through the irrigation line. DEMA DOES NOT OFFER AN ELECTRONIC FLOW METER and the flow meter will need to be ordered from an irrigation or plumbing component supplier. The electronic flow meter must include a 4 20mA output signal for connection to the Easy Dose. 1. Refer to electronic flow meter instruction guide for proper installation and wiring. 2. DIP switch 1 must be moved to Speed By Ext 3. DIP switch 2 must be moved to 4 20mA I 1201 Page 8 of 14

Programming, Setup & Operation 1. DIP Switches should be set as follows for typical application when not using electronic flow meter technology. a. DIP 1 = set to Speed by Pot b. DIP 2 = either setting will work c. DIP 3 = set to Pump Output d. DIP 4 = independent (float switch for each pump) or combined (one float switch controls both pumps. i. DIP 4 is for when 2 pumps are being used in the application 2. Fill the chemical reservoir with the appropriate chemical/water mixture. 3. Turn the power switch for Easy Dose to the on position. 4. Prime the chemical pickup and discharge lines. a. To assure the best performance assure that the chemical lines are primed all the way to the quill injection point. b. The bleed valve at the quill will need to be opened to release air if the irrigation line is pressurized. 5. With water running through the irrigation line, adjust the speed control knob to obtain the correct injection amount. a. If using the analog flow meter, observe the flow rate. b. If not using the analog flow meter, refer to table below for an approximate injection rate. Control Setting Approximate Flow Rate (GPM) with Water Thin Chemical OPEN 10 PSI 20 PSI 30 PSI 40 PSI 50 PSI 60 PSI 70 PSI 100 1.8 1.7 1.5 1.4 1.3 1.2 1.1 0.8 90 1.7 1.6 1.4 1.3 1.2 1.1 0.1 0.7 80 1.6 1.4 1.2 1.2 1.1 1 0.9 0.6 70 1.4 1.3 1.1 1.1 1 0.9 0.8 0.5 60 1.3 1.2 1 0.9 0.9 0.8 0.7 0.3 50 1.1 1 0.8 0.7 0.7 0.6 0.5 0.1 40 0.9 0.7 0.6 0.5 0.4 0.3 0.2 30 0.6 0.5 0.4 0.3 0.2 0.1 20 0.3 0.1 10 0.1 I 1201 Page 9 of 14

Replacement Parts 8511AC & 8511DC Models See 8511 Easy Dose Replacement Parts Table on Page 11 (Some components for the 8511DC model are shown on next page) I 1201 Page 10 of 14

8511 DC Model See 8511 Easy Dose Replacement Parts Table on Page 11 I 1201 Page 11 of 14

8511 Easy Dose Replacement Parts Item No. DEMA Kit No. Description 1 85.105.1 Enclosure 2 85.109.1 Cord Grip Liquid Tight 3 41.40.3 #6 32 x 1/4" Screw 4 41.40.4 #6 32 x 5/8" Screw 5 83.11.2 Toggle Switch 6 85.111.1 Toggle Switch Guard 7 85.112.1 Switch Cover (8511.AC Only) 85.136.1 Switch Cover (8511.DC Only) 8 40.476.1 Toggle Switch Boot 9 58.400.2 1/2" NPT Nylon Nut 10 85.106.1 Power Supply 12VDC 25A (8511.AC Only) 11 85.107.1 Power Supply Mounting Bracket 12 25.85.1 10 32 x 3/8" Screw 13 85.108.1 Control Board Bracket 14 84.32.1 #6 32 Hex Nut 15 85.123.1 Power Supply Bracket Clip (8511.AC Only) 16 85.124.1 Wire Kit (8511.AC Only) 85.137.1 Wire Kit (8511.DC Only) 17 25.128.6 Power Cord (8511.AC Only) 85.135.1 Power Cable (8511.DC Only) 18 85.110.1 Vented Plug 1" 19 85.104.1 Control Board 20 61.14 Snap Bushing 21 32.2.2 M4 x 6mm Screw (8511.AC Only) 22 85.138.1 Hole plug 0.875" 23 L1762 Electrical Rating Label (8511.AC Only) L1763 Electrical Rating Label (8511.DC Only) 24 L1701 On Off label 25 L897 Electrical Caution label 26 L1702 Inner Door Label 27 L1704 Front Door Label I 1201 Page 12 of 14

8512 Pump Easy Dose Replacement Parts Item No. DEMA Kit No. Description 1 85.113.1 Enclosure 2 85.110.1 Vented Plug 1" 3 85.109.1 Cord Grip Liquid Tight 4 85.139.2 Barrier Strip 2 Position 5 85.115.1 Pump Mounting Bracket 6 85.114.1 Pump 12VDC 1.2 GPM @ 60 PSI 7 25.85.1 #10 32 X 3/8" Screw 8 25.85.6 #10 32 X 1 1/4" Screw 9 58.400.2 1/2" NPT Nylon Nut 10 98.110.1 #10 Flat Washer 11 41.40.4 #6 32 X 5/8" Screw 12 85.120.1 Cable 13 25.124.8 Universal Bushing 1 3/4" 14 58.132.2 JG Stem Fitting 1/2" X 1/2" M NPT 15 81.182.6 Quick Connect Fitting 1/2" X 3/8" JG 16 81.182.4 Quick Connect Fitting 1/2" X 1/2" JG 17 L898 Chemical Caution Label 18 L1703 In/Out Label 19 L1704 Front Door Label I 1201 Page 13 of 14

Warranty Merchandise Returns No Merchandise will be Returned for Credit Without DEMA S Written Permission. Returned Merchandise Authorization Number is Required in Advance of Return. Product Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as o -rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See Merchandise Returns above). I 1201 Page 14 of 14