Service Parts, Kits and Accessories

Similar documents
Ransome Direct Fired Vaporizers VAPORIZERS & HEATERS RH240 RH50, RH80 & RH120. Direct-Fired LP-Gas Vaporizer. RH200 thru RH1000

Owner's Manual and Instructions

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

INSTALLATION AND OPERATION INSTRUCTIONS

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Owner's Manual and Instructions

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Owner's Manual and Instructions

INSTALLATION AND OPERATION INSTRUCTIONS

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Construction Heater GENERAL HAZARD WARNING

CINCINNATI, OH USA

Owner's Manual and Instructions

User s Manual and Operating Instructions

User s Manual and Operating Instructions

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Parts List for Ener-Radiant XL Tube Heaters

M-11 Series. Installation and Service Manual

e Bath Fan with Light User s Guide

GENERATION 2 QUADRATHERM Heater

Desiccant / Pump Dehumidification System. Model Operating Manual

Hot Surface Ignition. Agricultural Animal Confinement Building Heaters. Installation and Service Guide

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

WARMING AND MERCHANDISING CABINET

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

INSTALLATION AND OPERATING MANUAL

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

e Heater/Exhaust Fan/Light User s Guide

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

MODEL CDB8 INSTALLATION INSTRUCTIONS

DH Series Portable Industrial Unit Blower Air Heaters

e Bath Fan with Light User s Guide

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

READ AND SAVE THESE INSTRUCTIONS

WARMING AND MERCHANDISING CABINET

W6636 East Avenue North, Onalaska, WI USA (608) Fax: (608)

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

MN908 No. 282C Replaces 282B LB7013

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Installation and Maintenance "L" and "LS" Series

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

The Economical, Unitary Infrared Heater Submittal: BH Series

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Sound Cover [ , , , ]

Power Direct Vent PDV(S&T) Models

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

MaxLite LED Vapor Tight Linear Fixture

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

THC- 355DF (Dual Fuel)

CPL Series Pedestal Convection Heater

Construction Heater GENERAL HAZARD WARNING

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

ASSEMBLY INSTRUCTIONS

Repeat procedures for other side.

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

INFRARED RADIANT HEATERS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

MaxLite LED Round Pendant Highbay Series

MODEL 995 STEAM TABLE

Installation & Maintenance Instructions

INFRARED RADIANT TUBE HEATER

ASSEMBLY INSTRUCTIONS

e Bath Fan with Light User s Guide

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Electric Space Heater

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

FLCH4R Garage and Utility Electric Heater

Low-Intensity, Infrared Heating Systems Submittal: HE Series

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Condensate Pump. Installation and Safety Instructions CP-16 CP

Installation & Maintenance Instructions

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

LEAVE THIS MANUAL WITH HOMEOWNER

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

OPERATIONS MAINTENANCE MANUAL

TJERNLUND PRODUCTS, INC.

Steam Humidifier Fan Pack Installation & Maintenance Instructions

55-Gallon Dispenser Package

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

Transcription:

The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components not only used on current production, but also on equipment that is of earlier design. To use the guides properly, you should know the model numbers of the heater and its design sequence. This information is identified on the dataplate. Some models may have the design sequence shown as the 4th digit of the model number. For other models, the dataplate will identify a configuration number. The design sequence is the first digit of the configuration number. In many cases you will find components are common between different designs of the model number. Parts lists and schematics are shown on the following pages for the respective heaters. The parts guides also identify part numbers for the most commonly requested components, wires, and hardware items used on the heaters. If a wire, nut, or screw, etc. is not identified, please contact the L. B. White Co. for parts ordering information. Without Configuration Number MODEL 346K AW075EHP3 SERIAL NO.: Design Sequence Dataplate Comparison A DESI GN A MERI CERT C GA S SSOC A N I ON I AT I FI ED With Configuration Number MODEL AW060 AB250 CONFIGURATION NO. AHPD20000 APPD0004 SERIAL NO.: Design Sequence MAXIMUM INPUT: 75,000 60,000 BTUH TYPE FUEL: PROPANE VAPOR WITHDRAWAL BURNER MANIFOLD PRESSURE 0 IN W.C. AT MAXIMUM INPUT MAXIMUM INPUT: 60,000 250,000 BTUH TYPE FUEL: PROPANE VAPOR WITHDRAWAL BURNER MANIFOLD PRESSURE 0.0 IN W.C. AT MAXIMUM INPUT ELECTRICAL: 5 VOLTS A.C. 60 HZ SINGLE PHASE.4 AMPS MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 6 FT IN. SIDES 6 FT IN. TOP TO CEILING 6 FT IN. BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT VENTILATION: 450 250 CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. MAXIMUM 3.5 INCHES W.C. AND MINIMUM.5 INCHES W.C. GAS SUPPLY PRESSURE ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. POSITION HEATER AWAY FROM LIVESTOCK AGRICULTURAL BUILDING HEATER ELECTRICAL: 5 VOLTS A.C. 60 HZ SINGLE PHASE.5 AMPS MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR FT SIDES FT TOP TO CEILING FT BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT VENTILATION: 050 240 CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. MAXIMUM 3.5 INCHES W.C. AND MINIMUM.5 INCHES W.C. GAS SUPPLY PRESSURE ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. POSITION HEATER AWAY FROM LIVESTOCK AGRICULTURAL BUILDING HEATER A DESI GN A MERI C CERT A N GA S ON ATI I I FI ED SSOC L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI 54650 608/783-569 L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI 54650 608/783-569 August 999 9.-

Model AS040 Item Description Design Sequence Part Number Regulator, Second Stage, Vent Over Side (LP Gas) A 550-06665 Regulator, Single Stage (Natural Gas) A 550-0326 2 Nipple, /2 x 3 /2 A 30-0748 3 Valve, Manual Shut-Off A 30-05548 4 Hose, /2 x 0 ft. A 550-20543 5 Sediment Trap A 500-0085 6 Adapter, /2 NPT x /2 NPS A 30-02894 7 Nipple, 3/8 x /2 A 30-0242 8 Bushing A 30-095 9 Bolt A 30-05576 0 Valve, Gas Control (LP Gas or Natural Gas) A 500-02309 Cap, Pilot A 30-06844 2 Bracket, Terminal Strip A 225-08245 3 Terminal Strip A 20-08253 4 Cover, Terminal Strip A 225-08246 5 Manifold (LP Gas) A 400-08774 Manifold (Natural Gas) A 400-08780 6 Orifice, Burner (LP Gas) A 30-08666 Orifice, Burner (Natural Gas) A 30-08667 7 Burner A 0-08766 8 Thermocouple, 8 in. A 20-0090 9 Tube, Pilot A 40-08769 20 Orifice (LP Gas) A 30-02689 Orifice (Natural Gas) A 30-02740 2 Screw, Pilot A 30-08048 22 Pilot Assembly with Orifice (LP Gas) A 30-02729 Pilot Assembly with Orifice (Natural Gas) A 30-0274 23 Shield, Pilot (LP Gas) A 220-03408 Shield, Pilot (Natural Gas) A 220-06534 24 Switch, High Limit A 20-05566 25 Spacer A 30-08375 26 Clip A 30-0759 27 Door, Burner End () A 27-08759 28 Handle A 40-09297 29 Panel, Air Inlet A 27-08760 30 Panel, Motor Access A 27-0907 3 Case Assembly () A 400-08775 32 Housing, Fan A 400-08988 33 Fan Blade A 30-08746 34 Mount, Motor A 220-08764 35 Spacer A 30-08375 36 Motor A 20-08745 37 Chamber, Heat A 400-08772 38 Holder, Burner A 260-08757 39 Bracket, Manifold A 220-0902 40 Base A 220-08765 4 Cord, Power A 20-08285 () Specify fuel gas type and model number when ordering. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH PART NO. Wire, Harness, High Limit Switch Black 20 in. 430-08768 9.-2 FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw Case 30-02330 August 999

Model AS040 28 3 29 30 27 37 25 24 26 32 23 33 38 34 22 2 20 6 7 4 35 36 9 8 5 39 42 0 2 3 40 6 4 9 5 INSTALLATION OF GAS TRAIN ASSEMBLY FOR NATURAL GAS ONLY 3 2 August 999 8 7 7 8 4 9.-3

Models 346 and 348 Design Sequence Item Description Regulator, Single Stage (LP Gas) E X F X G X H X J X K X Part Number 550-06772 Regulator, Second Stage (LP Gas) X X X X X X 550-06665 Regulator, Single Stage (Natural Gas) X X X X X X 550-0326 Regulator, Second Stage (Natural Gas) X X X X X X 500-06408 2 Hose, /4 in. ID x 0 ft. X X X X X X 550-20543 Hose, /2 in. ID x 0 ft. X X X X X X 400-20504 3 Adapter, /4 NPT x 9/6-8 X X X X X X 30-0098 4 Valve, Manual Shut-Off X X X X X X 30-05548 5 Bushing, 3/8 NPT x /4 X X X X X X 30-0544 6 Bushing, /2 x /4 X X X X X X 30-059 7 Nipple, /2 x /2 X X X X X X 30-02420 8 Bushing, /2 x 3/8 X X X X X X 30-095 9 Nipple, 3/8 x /2 X X X X X X 30-0242 0 Adapter, /2 NPT x /2 NPS X X X X X X 30-02894 Thermostat with Bracket X X X X X X 500-05568 2 Junction Box X X X X X X 20-03230 3 Cover, Junction Box X X X X X X 20-0323 4 Cord, Power, 5 ft. X X X X X X 20-0220 5 Bracket, Thermostat X X X X X X 220-05493 6 Valve, Pilot Gas Control (LP Gas or Natural Gas) () () X X X N/A 500-02309 Valve, Pilot Gas Control (LP Gas) N/A N/A N/A N/A N/A X F20-86302 Valve, Pilot Gas Control (Natural Gas) N/A N/A N/A N/A N/A X 40-240 7 Cap, Pilot, Gas Control Valve N/A N/A X X X N/A 30-06844 8 Orifice, Burner (LP Gas) X X X X X X 30-0348 Orifice, Burner (Natural Gas) X X X X X X 30-0297 9 Burner Casting N/A N/A X X X X 320-08026 Burner Casting X X N/A N/A N/A N/A 320-0340 20 Pilot Assembly with Orifice (LP Gas) X X X X X X 30-02729 Pilot Assembly with Orifice (Natural Gas) X X X X X X 400-0274 2 Orifice, Pilot (LP Gas) X X X X X X 30-02689 Orifice, Pilot (Natural Gas) X X X X X X 30-02740 22 Shield, Pilot X X X X X X 220-08205 23 Tube, Pilot with Nuts X X X X X N/A 550-03032 Tube, Pilot with Nuts N/A N/A N/A N/A N/A X 550-2380 24 Thermocouple, 2 in. X X X X X X 20-03497 25 Base X X X X X 220-242 Base N/A N/A N/A N/A N/A X 220-242 26 Motor X X X X X X 500-07487 27 Mount, Motor (2) (2) X X X x 220-05490 28 Wheel, Fan X X X X X X 30-02808 29 Housing, Fan X X X X X X 500-05579 30 Switch, High Limit X X X X X X 20-05566 3 Cover, High Limit X X X X X X 220-05567 32 Case, Assembly X X X X X X 500-022(3) 33 Handle X X X X X X 40-09297 34 Chamber, Heat X X X X X N/A 40-09297 Chamber, Heat N/A N/A N/A N/A N/A X 420-07767 35 Bracket, Gas Control Valve N/A N/A N/A N/A N/A X 225-22095 36 Cover N/A N/A N/A N/A N/A X 225-22096 37 Sediment Trap X X X X X X 500-0085 () For replacement control valve, order conversion kit part 500-03398. (2) Not used on E and F designs. (3) Specify fuel gas type and model number when ordering. N/A Not Applicable. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, High Limit Black 25 in. All 430-06373 FASTENER SELECTION TABLE DESCRIPTION APPLICATION DESIGN PART NO. Screw, 8 x 3/4 Sheet Metal High Limit Switch, Mounting All 30-02330 Screw, 0-24 x /4 Machine Burner Mounting E-J 30-08028 Bolt, 3/8-6 x 5/8 Gas Control Valve to Base E-J 30-05576 Spacer Gas Control Valve to Base E-J 30-05489 Screw All Other Applications All 30-07289 Washer Burner Mounting K 30-0589 Screw Burner Mounting K 30-03068 9.-4 August 999

Models 346 and 348 33 32 3 34 30 29 28 27 9 26 7 20 6 22 9 8 36 8 2 24 25 8 9 37 4 35 3 4 6 2 6 23 5 5 2 3 2 TO NATURAL GAS SUPPLY 0 SEDIMENT TRAP KIT OPTIONAL ACCESSORY 4 August 999 9.-5

Models 377 and 379 Design Sequence Item Description E F G H J K Part Number Regulator, Single Stage (LP Gas) X X X X X N/A 550-06772 Regulator, Single Stage (LP Gas) N/A N/A N/A N/A N/A X 40-2408 Regulator, Second Stage (LP Gas) X X X X X X 550-06665 Regulator, Single Stage (Natural Gas) X X X X X X 550-02736 2 Adapter, Hose, 3/8 NPT x /2 NPS X X X X X N/A 30-03536 Adapter, Hose, /2 NPT x /2 NPS N/A N/A N/A N/A N/A X 30-02894 3 Hose, /2 in. ID x 0 ft. X X X X X X 400-20504 4 Junction Box X X X X X X 20-03230 5 Cover, Junction Box X X X X X X 20-0323 6 Thermostat with Bracket X X X X X X 500-05568 7 Bracket X X X X X X 220-05493 8 Cord, Power, 5 ft. X X X X X X 20-03438 Cord, Power, 0 ft. X X X X X X 20-0305 9 Base, Terminal Board X X X X X N/A 20-207 0 Cover, Terminal Board X X X X X N/A 500-02686 Valve, Manual Shut Off X X X X X X 30-05548 2 Nipple, /2 x /2 X X X X X N/A 30-02420 3 Valve, Gas Control (LP Gas or Natural Gas) () () X X X N/A 500-02309 Valve, Gas Control (LP Gas) N/A N/A N/A N/A N/A X 20-2839 Valve, Gas Control (Natural Gas) N/A N/A N/A N/A N/A X 20-2840 4 Cap, Pilot X X X X X N/A 30-06844 5 Bushing, Reducing X X X X X N/A 30-059 6 Tube, Pilot with Nuts X X X X X N/A 30-03580 Tube, Pilot with Nuts N/A N/A N/A N/A N/A X 40-2526 7 Orifice, Pilot (LP Gas) X X X X X X 30-02689 Orifice, Pilot (Natural Gas) X X X X X X 30-02740 8 Pilot Assembly with Orifice (LP Gas) X X X X X X 30-02729 Pilot Assembly with Orifice (Natural Gas) X X X X X X 30-0274 9 Thermocouple, 2 in. X X X X X X 20-03497 20 Shield, Pilot X X X X X N/A 220-03509 Shield, Pilot N/A N/A N/A N/A N/A X 220-20264 2 Holder, Orifice X X X X X N/A 30-02690 22 Orifice, Burner (LP Gas) X X X X X N/A 30-0358 Orifice, Burner (Natural Gas) X X X X X N/A 30-0359 Orifice, Burner (LP Gas) N/A N/A N/A N/A N/A X 30-2525 Orifice, Burner (Natural Gas) N/A N/A N/A N/A N/A X 30-2528 23 Manifold, U-Shape X X X X X N/A 40-0706 Manifold, Welded N/A N/A N/A N/A N/A X 420-07826 24 Burner, Casting X X X X X X 320-03453 25 Gasket N/A N/A N/A N/A N/A X 30-06974 26 Screw, Burner Mounting X X X X X X 30-02688 27 Stud, Pilot N/A N/A N/A N/A N/A X 30-07827 28 Screw, Pilot X X X X X X 30-03070 29 Spacer, Burner X X X X X X 30-02687 30 Switch, High Limit X X X X X X 20-05566 3 Washer X X X X X N/A 30-02686 32 Chamber, Heat X X X X X X 400-2522 33 Case, Assembly X X X X X X 500-05628 (2) 34 Panel, Case, Burner End X X X X X X 27-07334 (2) 35 Panel, Case, Opposite Burner X X X X X X 27-07335 36 Ring, Inlet N/A N/A X X X X 220-05507 37 Fan, Wheel X X X X X X 30-0353 38 Flapper N/A N/A X X X X 40-0294 39 Housing, Fan with Air Proving Switch and Flapper X X X X X X 500-05572 40 Switch, Air Proving N/A N/A X X X X 500-02680 4 Motor X X X X X X 550-06008 42 Base X X X X X X 220-2045 43 Washer X X X X X X 30-0589 44 Bolt, Burner X X X X X N/A 30-02692 Bolt, Burner N/A N/A N/A N/A N/A X 30-07908 45 Bracket, Gas Control Valve N/A N/A N/A N/A N/A X 220-2043 46 Screw N/A N/A N/A N/A N/A X 30-09425 47 Spacer, Nylon N/A N/A N/A N/A N/A X 30-07905 48 Sediment Trap X X X X X X 500-0085 () For replacement control valve, order conversion kit part 500-03398. (2) Specify fuel gas type and model number when ordering. N/A 9.-6 Not Applicable. FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, # 8 x 3/8 Case Assembly 30-07288 WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Thermostat to Black 6 in. All 430-07227 Terminal Board Wire, High Limit Switch Black 25 /4 in. All 430-0305 Wire, Air Flow Switch Black 4 in. All 430-05557 August 999

Models 377 and 379 34 35 33 32 3 37 36 30 24 29 8 20 25 2 7 6 9 3 4 2 28 5 27 2 26 22 23 0 9 4 4 40 42 39 38 NATURAL GAS SUPPLY 8 5 2 22 23 7 6 3 47 3 45 46 43 44 48 SEDIMENT TRAP KIT OPTIONAL ACCESSORY August 999 9.-7

Models 408 and 40 Design Sequence Item Description E F G H J K Part Number Regulator, Single Stage (LP Gas) X X X X X X 400-099 Regulator, Second Stage (LP Gas) X X X X X X 550-06665 Regulator, Single Stage (Natural Gas) X X X X X X 550-02736 Regulator, Second Stage (Natural Gas) X X X X X X 500-06408 2 Hose, /2 in. x 0 ft. X X X X X X 400-20504 3 Adapter, /2 NPT x /2 NPS X X X X X X 30-02894 4 Valve, Manual Shut Off X X X X X X 30-05548 5 Nipple, /2 in. x 3 /2 in. X X X X X X 30-0748 6 Elbow X X X X X X 30-0359 7 Valve, Gas Control (LP Gas and Natural Gas) () () X X X N/A 500-02309 Valve, Gas Control (LP Gas) N/A N/A N/A N/A N/A X 20-2839 Valve, Gas Control (Natural Gas) N/A N/A N/A N/A N/A X 20-2840 8 Cap, Pilot Safety X X X X X N/A 30-06844 9 Bushing X X X X X N/A 30-059 0 Nipple, /4 in. x 3 in. X X X X X N/A 30-034 Holder, Orifice X X X X X N/A 30-02690 2 Orifice, Burner (LP Gas) X X X X X N/A 30-0269 Orifice, Burner (Natural Gas) X X X X X N/A 30-02740 Orifice, Burner (LP Gas) N/A N/A N/A N/A N/A X 30-2573 Orifice, Burner (Natural Gas) N/A N/A N/A N/A N/A X 30-2574 3 Screw N/A N/A N/A N/A N/A X 30-09425 4 Spacer, Nylon N/A N/A N/A N/A N/A X 30-07905 5 Manifold N/A N/A N/A N/A N/A X 420-07826 6 Bracket N/A N/A N/A N/A N/A X 230-09290 7 Thermocouple, 2 in. X X X X X X 20-03497 8 Tube, Pilot with Nuts X X X X X N/A 550-03032 Tube, Pilot with Nuts N/A N/A N/A N/A N/A X 550-2380 9 Orifice, Pilot (LP Gas) X X X X X X 30-02689 Orifice, Pilot (Natural Gas) X X X X X X 30-02740 20 Pilot Assembly with Orifice (LP Gas) X X X X X X 30-02729 Pilot Assembly with Orifice (Natural Gas) X X X X X X 30-0274 2 Gasket, Pilot N/A N/A X X X X 30-06974 22 Shield, Pilot (LP Gas) X X X X X N/A 220-03408 Shield, Pilot (Natural Gas) X X X X X N/A 420-03455 Shield, Pilot (LP and Natural Gas) N/A N/A N/A N/A N/A X 220-20264 23 Burner (LP Gas) X X X X X (2) 320-03453 Burner (Natural Gas) X X X X X N/A 320-03454 24 Spacer, Burner X X X X X X 30-02687 25 Cord, Power, 5 ft. X X X X X X 20-03438 Cord, Power, 0 ft. X X X X X X 20-0305 26 Bracket, Thermostat X X X X X X 220-05493 27 Stud, Pilot N/A N/A N/A N/A N/A X 30-07827 28 Screw, Pilot X X X X X X 30-03070 29 Washer X X X X X X 30-0589 30 Bolt X X X X X N/A 30-02692 Bolt N/A N/A N/A N/A N/A X 30-07908 3 Thermostat with Bracket X X X X X X 500-05568 32 Cover, Junction Box X X X X X X 20-0323 33 Junction Box X X X X X X 20-03230 34 Cover, Terminal Board X X X X X N/A 500-02686 35 Base, Terminal Board X X X X X N/A 20-207 36 Screw, Burner X X X X X X 30-02688 37 Switch, High Limit X X X X X X 20-05566 38 Washer X X X X X N/A 30-02686 39 Chamber, Heat X X X X X X 400-0924 40 Case Assembly X X X X X X 500-02673(3) 4 Panel, Case, Burner End X X X X X X 27-07333(3) 42 Panel, Case, Motor End X X X X X X 27-07332 43 Motor X X X X X X 550-06008 44 Mount, Motor N/A N/A X X X X 220-03764 45 Switch, Air Proving N/A N/A X X X X 500-02680 46 Flapper N/A N/A X X X X 240-0244 47 Fan, Wheel X X X X X X 30-02684 48 Housing with Air Proving Switch and Flapper N/A N/A X X X X 500-05570 49 Base X X X X X X 220-05570 50 Sediment Trap X X X X X X 500-0085 () For replacement control valve, order conversion kit part #500-03398. (2) Part #320-03453 is used for LP and Natural Gas on K design heaters. (3) Specify fuel gas type when ordering. N/A Not Applicable. 9.-8 FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, # 8 x 3/8 Case Assembly 30-07288 WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Thermostat to Black 2 /2 in. All 430-02723 Terminal Board Wire, Air Flow Switch Black 42 in. All 430-02724 Wire, High Limit Switch Black 25 /4 in. All 430-0305 August 999

Models 408 and 40 4 42 40 39 37 38 47 43 33 36 45 44 32 22 24 46 3 27 20 26 28 2 23 5 2 0 49 48 34 8 35 7 25 9 8 29 7 4 7 3 9 6 5 6 5 4 NATURAL GAS SUPPLY 50 30 3 2 SEDIMENT TRAP KIT OPTIONAL ACCESSORY August 999 9.-9

Model AB200 Design Sequence Item Description A B Part Number Regulator, Second Stage (LP Gas) X X 550-06553 Regulator (Natural Gas) X X 550-02736 2 Nipple, /2 x 3 /2 X X 30-0748 3 Valve, Manual Shut-Off X X 30-05548 4 Hose, /2 in. ID x 0 ft. X X 400-20504 5 Adapter, Hose X X 30-02894 6 Kit, Sediment Trap X X 500-0085 7 Nipple, /2 x /2 X X 30-02420 8 Valve, Pilot Gas Control (LP Gas or Natural Gas) X X 500-02309 9 Cap, Pilot X X 30-06844 0 Manifold, Welded X X 30-07826 Orifice, Burner (LP Gas) X X 30-08056 Orifice, Burner (Natural Gas) X X 30-08057 2 Thermocouple, 8 in. X X 20-0090 3 Tube, Pilot, with Nuts X X 550-0302 4 Orifice, Pilot (LP Gas) X X 30-07829 Orifice, Pilot (Natural Gas) X X 30-06968 5 Screw, Wing X X 30-07484 6 Bracket, Pilot X X 30-0783 7 Screw, Burner Mounting X X 30-02688 8 Spacer, Burner X X 30-02687 9 Shield, Pilot with Pilot Stack X X 500-07864 20 Casting, Burner X X 320-03453 2 Stud, Pilot Mounting X X 30-07827 22 Cover, Terminal Strip N/A X 220-08246 23 Bracket, Terminal Strip N/A X 225-08245 24 Strip, Terminal N/A X 20-08253 25 Cover, Terminal Board X N/A 400-05970 26 Board, Terminal X N/A 20-207 27 Switch, High Limit X X 500-07887 28 Chamber, Heat X X 400-07763 29 Bracket, Flame Lift Off X X 220-0823 30 Case Assembly X X 400-08299() 3 Door, Access, Right X X 500-08297( ) 32 Door, Access, Left X X 500-0825 33 Hinge X X 30-05868 34 Latch X X 30-09073 35 Motor X X 550-20554 36 Mount, Motor X X 220-03764 37 Wheel, Fan X X 30-02684 38 Flapper X X 240-0244 39 Switch, Air Proving X X 500-02680 40 Housing with Air Proving Switch and Flapper X X 400-05569 4 Base X X 225-07837 42 Bolt X X 30-02692 43 Washer X X 30-0589 44 Cord, Power X X 20-03438 () Specify fuel gas type and model number when ordering. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Air Proving Switch to Terminal Board Black 42 in. All 430-02724 wire, High Limit Switch Black 25 /4 in. All 430-0305 Wire, Thermostat to Terminal Board Black 2 /2 in. All 430-05263 FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, #8 x 3/8 Case Assembly 30-007288 9.-0 August 999

Model AB200 3 33 32 30 34 37 35 36 44 39 38 40 9 29 7 8 2 27 28 4 26 25 NATURAL GAS SUPPLY 6 20 2 5 4 3 2 22 24 23 43 42 0 8 9 5 4 3 7 6 August 999 9.-

Model AB250 Design Sequence Item Description A Part Number Regulator, Second Stage, Vent Over Side (LP Gas) X 550-06553 Regulator, Second Stage (Natural Gas) X 500-07087 2 Nipple, 3 /2 in. X 30-0748 3 Valve, Manual Shut-Off X 30-05548 4 Adapter, Hose, /2 NPT x /2 NPS X 50-02894 5 Hose, /2 in. ID x 0 ft. X 550-20704 6 Kit, Sediment Trap X 500-0085 7 Base X 225-2043 8 Bracket, Gas Control Valve X 225-09506 9 Bolt X 30-02692 0 Valve, Gas Control (LP Gas) X 40-20439 Valve, Gas Control (Natural Gas) X 40-20440 Nipple, /2 in. x /2 in. X 30-02420 2 Valve, Throttle (LP Gas) X 40-2043 Valve, Throttle (Natural Gas) X 40-2044 3 Ell, Street X 30-0359 4 Manifold X 420-0929 5 Orifice, Burner (LP Gas) X 30-204 Orifice, Burner (Natural Gas) X 30-2042 6 Gasket, Pilot X 30-06974 7 Thermocouple, 2 in. X 20-03497 8 Tubing, Pilot X 40-20436 9 Orifice, Pilot (LP Gas) X 30-07829 Orifice, Pilot (Natural Gas) X 30-06968 20 Cover, Pilot (Bottom) X 225-20265 2 Screw, Wing X 30-07484 22 Stud X 30-07827 23 Pilot, Bracket X 30-0783 24 Shield, with Pilot Barrel X 500-20264 25 Terminal Strip X 20-08253 26 Enclosure, Electrical X 225-20028 27 Cover, Electrical X 225-20027 28 Screw X 30-02688 29 Burner X 320-03453 30 Spacer X 30-02687 3 Switch, High Limit X 20-05566 32 Chamber, Heat X 400-20024 33 Door, Left or Right X 225-08629 34 Cord, Power X 20-20426 35 Latch X 30-09467 36 Hinge X 430-05868 37 Case Assembly X 500-20434() 38 Motor X 20-2069 39 Mount, Motor X 225-08647 40 Wheel, Fan X 30-09050 4 Switch, Air Proving X 500-02680 42 Flapper (Sail) X 240-09076 43 Housing, Fan, with Flapper, Air Proving, and Motor Mount X 500-20250 () Specify fuel gas type and model number when ordering. NOTE: For fixed rate heater, replace items, 2 and 3 with a /2 in. elbow, part number 30-0426 and nipple, /2 in. x 3 /2 in., part number 30-0748. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH PART NO. Wire, Gas Control to Terminal Strip White 24 in. 20-20423 Wire, Air Flow Switch to Terminal Strip Black 45 in. 20-20424 FASTENER SELECTION TABLE Wire, High Limit Switch DESCRIPTION APPLICATION PART NO. to Air Flow Switch Black 60 in. 20-20425 Bolt Burner Mounting 30-02692 9.-2 August 999

Model AB250 37 33 36 34 40 38 35 33 39 4 32 42 43 27 3 29 30 7 24 23 22 2 20 9 26 8 25 3 2 7 45 6 5 4 28 0 4 5 3 2 9 8 6 August 999 9.-3

This section provides part numbers for many of the more commonly requested kits and accessories used on pilot light ignition heaters. GAS CONVERSION KITS Control Valves without Internal Low Pressure Regulators and Gas Shut Offs (Control Valve Part #500-02309) PART PROPANE TO NATURAL GAS NUMBER MODEL NUMBER DESIGN(S) 500-09358 346 G, H and J 500-09360 377 G, H and J 500-09362 408 G, H and J 500-09364 AB200 A 500-09366 AS040 A NATURAL GAS TO PROPANE 500-09359 348 G, H and J 500-0936 379 G, H and J 500-09363 40 G, H and J 500-09365 AB200 A 500-09367 AS040 A GAS CONVERSION KITS Control Valves with Internal Low Pressure Regulators and Gas Shut Offs PART PROPANE TO NATURAL GAS NUMBER MODEL NUMBER DESIGN(S) 500-269 346 K 500-2620 377 K 500-262 408 K 500-20650 AB250 A NATURAL GAS TO PROPANE 500-2622 348 K 500-2623 379 K 500-2624 40 K 500-20652 AB250 A 9.2- August 999

PART NUMBER TEST KITS DESCRIPTION 550-00764 Low Gas Pressure Test Kit 550-08506 Thermocouple Test Kit PART NUMBER MISCELLANEOUS KITS DESCRIPTION 500-07802 Indoor Chain Hanging Kit DESCRIPTION AIR DIVERTERS MODELS PART NUMBER Two Piece (Snap-In) 346, 348 550-07742 AB200, 377, 379, 408, 40 550-07434 AB250 550-20048 One Piece 346, 348 500-0080 AB200, 377, 379, 408, 40 500-00808 DESCRIPTION THERMOSTATS Remote Thermostat - Penn Stainless Steel (Less Wiring) Remote Thermostat - Penn Stainless Steel w/20' Series Tap Cord Remote Thermostat - Nema 4X w/20' Series Tap Cord Remote Thermostat - Nema 4X Meets NEC Article 547 (Less Wiring) PART NUMBER 500-06537 500-0083 500-09454 500-0938 August 999 9.2-2

Warranty Guidelines Equipment and Parts EQUIPMENT L.B. White Co., Inc. warrants that the component parts of its heater are free from defects in material and workmanship, when properly installed, operated, and maintained in accordance with the Installation and Maintenance Instructions, safety guides and labels contained with each unit. If, within 2 months from the date of purchase by the end user, any component is found to be defective, L.B. White Co., Inc. will at its option, repair or replace the defective part or heater, with a new part or heater, F.O.B., Onalaska, Wisconsin. A warranty card on file at L.B. White will automatically qualify a unit and its component parts for warranty consideration. If a warranty card is not on file, a copy of the bill of sale will be required to establish warranty qualification. If neither is available, the warranty period will be 2 months from date of shipment from L B. White. PARTS L.B. White Co., Inc. warrants that replacement parts purchased from the company and used on the appropriate L.B. White heaters are free from defects both in material and workmanship for 2 months from the date of purchase by the end user. Warranty is automatic if a component is found defective within 2 months of the date code marked on the part. If the defect occurs more than 2 months later than the date code but within 2 months from the date of purchase by the end user, a copy of a bill of sale will be required to establish warranty qualification. The warranty set forth above is the exclusive warranty provided by L.B. White, and all other warranties, including any implied warranties or merchantability or fitness for a particular purpose, are expressly disclaimed. In the event any implied warranty is not hereby effectively disclaimed due to operation of law, such implied warranty is limited in duration to the duration of the applicable warranty stated above. The remedies set forth above are the sole and exclusive remedies available hereunder. L.B. White will not be liable for any incidental or consequential damages directly or indirectly related to the sale, handling or use of the heater, and in any event L.B. White's liability in connection with the heater, including for claims based on negligence or strict liability, is limited to the purchase price. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. REPLACEMENT PARTS AND SERVICE Contact your local L.B. White dealer for replacement parts and service or call the L.B. White Co., Inc. at -800-345-7200 for assistance. Be sure that you have your heater model number and configuration number when calling. August 999 0.-

Warranty Guidelines Warranty Returns Warranty Returns To complement L.B. White s warranty, the following has been written to simplify the warranty return policy. Our goal is to process warranty returns and issue the appropriate credit to you as promptly as possible. Your cooperation in following the procedures listed below will help us achieve our goal.. Units and Sub-Assemblies A. Defective heaters and sub-assemblies may be returned to L.B. White by authorized L. B. White service dealers by obtaining factory approval and a Return Authorization Number prior to any return shipment. The following information must be supplied when requesting a Return Authorization Number:. Complete heater model and serial number 2. Customer's name and address 3. Date sold 4. Date installed 5. Date failed 6. Probable cause of equipment failure 0.2- B. The Return Authorization Number must be shown on all transmitting paperwork and marked on the outside of the merchandise return carton. A warranty card on file at L.B. White will automatically qualify the unit, sub-assembly, or component for a 2-month warranty from date of purchase if the material being returned is found defective. Items must be returned freight PREPAID. Return of New Items for Credit. Factory Approval Factory approval and a Return Authorization Number must be obtained before any new product or part is returned to L. B. White or credit may not be issued. 2. Freight All items returned for credit must be shipped freight prepaid. 3. Restocking Charge A 5% restocking charge will apply provided the item is new and in unused condition. Additional charges will be made if reconditioning or new packaging is required. Shipping Damage. Parcel Post All Parcel Post claims for damages or shortages must be made to L.B. White within 20 days of date of shipment. 2. Parts Authorized L.B. White service dealers can return defective service parts, qualified for warranty under the L.B. White Warranty Policy, as follows: A. By using L.B. White Material Return Tags. Prior factory approval is not required in this case. A Material Return Tag must be filled out completely and attached to each defective part being returned. Material Return Tags are available from L. B. White upon request. B. By using the Return Authorization Number procedure described in A. above. All items must be returned freight PREPAID. Out of warranty parts require factory approval and a Return Authorization Number prior to being returned. 3. Credit Credit will be issued if inspection indicates: A. The item is defective B. The item is within the warranty period C. Failure is due to normal use L.B. White is not responsible for the labor cost of removal of a defective product or part, or damages due to removal, or expenses incurred in shipping the product or part to or from L.B. White's plant, or the installation of the repaired or replaced product or part. 4. Item Shipped Incorrectly If the item was shipped in error, L.B. White will authorize shipping freight collect and rescind the 5% restocking charge if Step above is followed. 5. Materials Return Tag All parts returned to L.B. White must be accompanied by a Materials Return Tag with the Return Authorization Number. A separate tag is required for each part. 2. Truck or United Parcel Service Damage claims should be made by the customer directly to the carrier or UPS. August 999