Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Similar documents
Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Renovent Sky 300 (Plus)

BRINK Renovent HR Installation and Operation Manual

Demand ventilation 2.0

Evap WTW INSTALLATION INSTRUCTIONS D

Renovent Excellent 180 (Plus)

Renovent Excellent 450 (Plus)

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Air Comfort. Installation instructions (English) A

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

HRV Enthalpy. Catalogue

Healthy, comfortable and energy-efficient ventilation

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

SonoSelect and SonoSafe energy meters

Healthy, comfortable and energy-efficient ventilation

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Operation and maintenance instructions

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

USER-MANUAL Tamson Cool Cube Immersion Cooler

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

User manual Universal pipe notcher Type: AL100U V/400V

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Tempest TP420/180 Electric Pressure Washer

HYTEK ATEX APPROVED BUND ALARM

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Ventilation unit Zehnder ComfoAir 200

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Overview and Specifications

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

This label warns for risk of electrical shock when failing to observe.

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Ventilation Unit Zehnder ComfoAir 350

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

TTV 4500 / TTV 4500 HP / TTV 7000

Indoor/outdoor resistance thermometer Model TR60

Additional deviations may possibly be found if a complete type test is carried out on the product.

TSEK VHR EC HEAT RECOVERY UNITS

Technical Information HXV - HRV Ventilation

Owner Instructions Original Instructions Warning! Read instructions before using the machine. LoLine NLL 332 NLL 415

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

User s Instruction Manual Vertex GelMelt 8 Instructions for use

PRODUCTSHEET Plasmamade AirFilter GUC1212

2013 innovation. Room-by-room demand controlled heat recovery ventilation

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Lawnmowers (pedestrian controlled electric mains-powered)

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual

Frost Protection Thermostat

Instruction manual SPU II Hard alarm output contacts

With this symbol Gavita declares that this product complies with legal European requirements.

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

CI/SfB (57.5) November 2008

KK70 Silent. Installation and Operating Instructions L V001

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

COTES ALL-ROUND THE C30 RANGE

Test Lamp for 210 series flame detectors Non EX

Condensate water pumps

Installation instructions

HYTEK ATEX APPROVED TANK ALARM

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Product Data Sheet 4114 N/17HH-218. The engineer's choice

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Zehnder Comfosystems. ComfoAir 180 Datasheet

Lawn trimmers and lawn edge trimmers (hand held electric mains powered)

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

HRU ECO 4. user manual

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

KOMFORT EC DB Suspended heat recovery air handling units

Gas cylinder scale Model GCS-1

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Price Book 2015 Drum Pumps For Non-Corrosive Liquids

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

G Installation manual Solitude - dmev unit

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Instructions for the fan motor control system, SILVER C

AZN ATEX INSTALLATION AND MAINTENANCE

Transcription:

Technical Sheet Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Application The Brink Renovent Excellent is a heat recovery ventilation unit with an efficiency of 95%, a maximum ventilation capacity of 180 m 3 /h and low-energy fans. Features Renovent Excellent 180: steplessly adjustable air flowrates through a control panel; filter indication on the appliance and the possibility for filter indication on the multiple switch; a frost protection system which ensures that also at low outdoor temperatures the appliance's performance remains optimal and that, if necessary, it activates the standard preheater; low sound level; comes as standard with automatic bypass function constant flow control; low energy consumption high efficiency These installation instructions describe both the standard Renovent Excellent 180 and the Renovent Excellent 180 Plus. The Renovent Excellent (Plus) is available in a left-handed or right-handed version. A left-handed version has the filters on the left behind the filter plugs; a right-handed version has the filters on the right behind the filter plugs. The position of the air ducts differs for these two versions! For the correct position of the connection ducts and dimensions see page 5. When ordering an appliance always state the correct type; subsequent conversion to a different version is not possible. The Renovent Excellent 180 comes ready to plug in with a 230 V mains plug and a connection for a low-voltage multiple switch on the outside of the appliance. The Renovent Excellent 180 is available in two types: Renovent Excellent 180 Renovent Excellent 180 Plus Compared to the standard Renovent Excellent 180, the Renovent Excellent 180 Plus has a more extensive control board which increases the connection options. Version types Renovent Excellent 180 Type Version L or R Position air ducts Power supply Type code Renovent Excellent 180 Renovent Excellent 180 Plus Left-handed version 4 top connections Power plug 4/0 L Right-hand version 4 top connections Power plug 4/0 R Left-handed version 4 top connections Power plug 4/0 L+ Right-handed version 4 top connections Power plug 4/0 R+ Renovent Excellent 180 2

Version Technical information Renovent Excellent 180 Supply voltage [V/Hz] 230/50 Protection degree IP30 Dimensions (w x h x d) [mm] 560 x 600 x 315 Duct diameter [mm] Ø 125 External diameter condensate discharge [mm] Ø 20 Weight [kg] 25 Filter class G3 (F6 optional) Fan setting (factory setting) 1 2 3 Ventilation capacity [m 3 /h] 50 75 100 150 Permissible resistance ducts system [Pa] 7-15 21-35 36-62 73-139 Rated power [W] 13-14 20-22 28-34 56-74 Rated current [A] 0.12-0.14 0.19-0.20 0.26-0.29 0.51-0.62 Max. Rated current [A] 1.48 Cos φ 0.44-0.46 0.45-0.49 0.47-0.51 0.48-0.52 Packaging unit Packaging unit per pallet 6 Warranty period 2 years on parts and 5 years on the heat exchanger. Sound power Sound power Excellent 180 Ventilation capacity [m 3 /h] 75 100 150 Sound power Static pressure [Pa] 40 80 160 level Lw (A) Housing emission [db(a) 32 39 48 Duct from dwelling [db(a)] 31 37 45.5 Duct to dwelling [db(a)] 49 56 66 In practice, the value may deviate 1 db(a) as a result of measuring tolerances Renovent Excellent 180 3

Version Fan graph Resistance ducts system [Pa] Note: The value stated in the circle is the capacity per fan (in Watt) Flow rate [m 3 /h] Fan graph Renovent Excellent 180 Renovent Excellent 180 4

Version Connections and dimensions Renovent Excellent 180 Renovent Excellent right-handed version 75 77 213 79 168 125 10 mm Placing the wall mounting kit Renovent Excellent 180 right-handed 4/0 600 45 145 302 290 560 248 Renovent Excellent 180 left-handed version = To dwelling = To atmosphere 77 213 125 168 45 79 = From dwelling = From atmosphere 75 = Electric connections 600 145 = Connection condensate discharge 302 290 248 560 = Wall mounting bracket (note the correct position of the rubber strip, washers and caps) Renovent Excellent 180 left-handed 4/0 Renovent Excellent 180 5

Service Exploded view When ordering parts, in addition to the article code number (see exploded view), please state the type of the heat recovery appliance, the serial number, the year of production and the name of the part: N. B.: Appliance type, serial number and year of production are stated on the identification plate on the top of the appliance. Example Appliance type : Renovent Excellent 4/0 R Serial number : 282000134401 Year of production : 2013 Part : Fan Article code : 531618 Quantity : 1 Service parts 7 5 3 1 2 3 8 6 2 4 No. Article description Article code 1 Filter kit 2x G3 filter (standard version) 531525 2 Fan Excellent 180 (1 pcs) 531618 3 Temperature sensor (1 pcs) 531775 4 Control panel 531776 5 Heat exchanger Excellent 180 531498 6 Control board (Plus version) When replacing, please note the correct dip switch settings; see 8.1 531780 7 Cord with mains plug 230 V * 531978 8 Filter plug (2 pcs) 531841 * The mains cable has a print connector. When replacing it, always order a replacement mains cable from Brink. To prevent dangerous situations, a damaged mains connection can only be replaced by a qualified expert. Renovent Excellent 180 6

Certificates Declaration of Conformity DECLARATION OF CONFORMITY Manufacturer : Brink Climate Systems B.V. Address: R.D. Bügelstraat 3 7951 DA Staphorst, The Netherlands Product: Heat recovery appliance type: Renovent Excellent 180 Renovent Excellent 180 Plus The product described above complies with the following directives: 2006/95/EC (low voltage directive) 2004/108/EC (EMC directive) RoHS 2002/95/EC (substances directive) The product bears the CE label: Staphorst, 24-02-13 W. Hijmissen, Managing director prior notice. 38 Renovent Excellent 180 Renovent Excellent 180 - SEL-waarde 100 Pa SEL-value [J/m³] 1900 1875 1850 1825 1800 1775 1750 1725 1700 1675 1650 1625 1600 1575 1550 1525 1500 1475 1450 1425 1400 1375 1350 1325 1300 Meetrapport 0490 18-09-2013 Renovent Excellent 180 SEL-value at 100 Pa 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 Flow [m³/h] Modifications reserved Brink Climate Systems B. V. continuously strives after improvement of products and reserves the right to change the specifications without prior notice. Renovent Excellent 180 7

BRINK CLIMATE SYSTEMS B.V. P.O. Box 11 7950 AA Staphorst Tel. +31 (0) 522 46 99 44 Fax +31 (0) 522 46 94 00 info@brinkclimatesystems.nl www.brinkclimatesystems.nl