TECHNICAL DATA OBSOLETE

Similar documents
QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

quick response horizontal sidewall sprinkler vk360 (K8.0)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

Microfast quick response Fusible element hsw sprinkler

standard response fusible link sidewall sprinkler VK112 (K5.6)

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

standard response Fusible Link Upright sprinkler VK204 (K8.0)

TECHNICAL DATA. Page 1 of 6

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

standard response elo upright and pendent sprinklers (storage-density/area)

microfast and microfasthp quick conventional sprinklers

microfast quick response Pendent sprinkler VK302 (K5.6)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD/quick. Sprinkler 42o. August 8, 2011

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

quick response Sprinkler 105a October 25, 2010

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

micromatic Standard response Horizontal Sidewall sprinkler

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

microfast quick response extended coverage hsw sprinkler vk606

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

microfast sr/qr extended coverage pendent sprinkler

standard/quick response extended coverage light and ordinary hazard elo sprinklers

micromatic standard response Upright sprinkler VK100 (K5.6)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

standard response dry horizontal sidewall sprinklers

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

standard response elo upright sprinkler

micromatic standard response stainless steel sprinklers

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

standard response large orifice dry

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

standard response/ quick response extended coverage

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

TECHNICAL DATA vk470 (K3.0)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

freedom residential pendent sprinkler vk466 (K5.2)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA OBSOLETE

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

Standard Spray concealed horizontal sidewall sprinkler VK481

Transcription:

June 1, 2007 1. DESCRIPTION Viking Quick Response Fusible Element Pendent Sprinklers VK330, VK332, VK353 and HP Sprinklers VK318 and VK343 are small, thermosensitive, solder link spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are culus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2020 Sprinkler VK330 Refer to the Approval Chart on page 40c and Design Criteria on page 40d for culus and FM approval requirements that must be followed. 3. Specifications: Available since 2007. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers VK318 and VK343 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. Highpressure (HP) sprinklers can be identified by locating 250 stamped on the deflector. Sprinklers VK330, VK332, and VK353 are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Ap0`proval Chart Nominal K-Factor: Refer to the Approval Chart Overall Length: Refer to the Approval Chart Sprinkler 40a Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 for Sprinkler VK353. Copper UNS-C19500 for Sprinkler VK318. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinkler VK330): Brass UNS-C36000 Fusible Element Assembly: Nickel Alloy Trigger and Support: Stainless Steel UNS-S31600 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 For Teflon Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Fusible Element Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon = N Temperature Suffix ( F/ C): 165 /74 = C, 205 /96 = E, and 280 F (138 C) For example, sprinkler VK330 with a Brass finish and a 165 F/74 C temperature rating = Part No. 13960AC Form No. F_020607 New page 40a-f, issued June 1, 2007.

Sprinkler 40b June 1, 2007 Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A ½ ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Fusible Element Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 C) 100 F (38 C) None Intermediate 205 F (96 C) 150 F (65 C) White High 280 F (138 C) 225 F (107 C) Blue Sprinkler Finishes: Brass, Chrome-Enloy, White Polyester, Black Polyester, and Black Teflon Corrosion-Resistant Coatings 3 : White Polyester, Black Polyester, and Black Teflon Footnotes 1 Decorative sprinklers may not be color coded. The temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon coatings. For Teflon coated open sprinklers only, the waterway is coated.

June 1, 2007 Base Part Number 1 SIN Thread Size Approval Chart Quick Response Fusible Element Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Nominal K-Factor Overall Length Listings and Approvals 3 (Refer also to Design Criteria on page 40d.) NPT BSP U.S. metric 2 Inches mm culus 4 FM 5 NYC VdS LPCB Large Orifice 13975 VK353 3/4 20 mm 8.0 115.2 2-3/8 60 A1X, B1Y B2X -- -- -- -- -- Small Orifice 6 13960 10 VK330 1/2 15 mm 2.8 40.3 2-1/4 58 A1X, B1Y B2X -- -- -- -- -- 13961 10 VK332 1/2 15 mm 4.2 60.5 2-1/4 58 A1X, B1Y -- -- -- -- -- -- Base Part Number 1 SIN Thread Size Nominal K-Factor Maximum 250 PSI (17 bar) WWP Standard Orifice Overall Length Listings and Approvals 3 (Refer also to Design Criteria on page 40d.) NPT BSP U.S. metric 2 Inches mm culus 4 FM NYC VdS LPCB 13954 VK318 1/2 15 mm 5.6 80.6 2-1/4 58 A1X, B1Y -- -- -- -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice 6 13964 10 VK343 1/2 15 mm 2.8 40.3 2-3/16 56 A1X, B1Y -- -- -- -- -- -- Approved Temperature Ratings A - 165 F (74 C), 205 F (96 C), 280 F (138 C) B - 165 F (74 C) and 205 F (96 C) Approved Finishes 1 - Brass, Chrome-Enloy, White Polyester 8,9, Black Polyester 8,9, and Black Teflon 8,9 2 - Brass and Chrome-Enloy Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price schedule. Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Microfast Model F-1 Adjustable Escutcheon 10 Y - Standard surface-mounted escutcheon or the Viking Microfast Model F-1 Adjustable Escutcheon 10 or recessed with the Viking Micromatic Model E-1 or E-2 Recessed Escutcheon 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 FM Approved for installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. 7 The sprinkler orifice is bushed. 8 culus Listed as corrosion resistant. 9 Other colors are available on request with the same Listings and Approvals as the standard colors. 10 The Viking Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. Sprinkler 40c

Sprinkler 40d June 1, 2007 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 40c) Quick Response Fusible Element Pendent Sprinklers are culus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: Standard Sprinkler Wrench 10896W/B

June 1, 2007 Sprinkler 40e Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Figure 3: Sprinkler VK330 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon

Sprinkler 40f June 1, 2007 Figure 4: Sprinkler VK330 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_020607 New page 40a-f, issued June 1, 2007.