Fan heater Panther 6-15 Efficient fan heater for medium size premises

Similar documents
Fan heater Panther Powerful fan heater for large premises

Fan heater Panther WALL MOUNTED FAN HEATER

Original instructions. Panther 6-15 kw

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Industrial infrared heater IR For premises with large volumes and high ceilings

Fan heater SWT Ceiling mounted fan heater with water heat

Elztrip EZ100 Single panel radiant heater for offices, shops etc.

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

Industrial infrared heater IR

Thermozone ADR 200/300 E/W

Thermozone SF. Air curtains for vertical mounting in curved doorways

Thermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING

Thermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28

Thermozone RD. Air curtains for revolving doors

Thermozone AC 300/WAC 300

Original instructions AR

Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres

Thermozone AD Corinte

Air curtains. For a comfortable indoor climate

Radiant heaters - Offices, shops and public premises

Original instructions. Infrared heater IRCF...17

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

Controllers for refrigeration EVBOX1 data-logging extension

Controllers for refrigeration EVBOX1

NOEMI LARGE SIZE. Insulation class II, protection rating IP 55.

THERMASREG TR 040 THERMASREG TR 060

Air curtains. For a comfortable indoor climate

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

REMOTE CONTROL PROGRAMMING AND OPERATING MANUAL ENGLISH

Industrial ceiling fans Push down the heat from the ceiling and get significant energy savings!

Daikin air conditioners for your home, shops, restaurants and offices

Carbon infrared heater IHC

Dati Tecnici Technical Data

8/S1 AIR CURTAINS SONATA, SONATA-V. v 1.0 (en)

displei studio baciocchi 2010

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Mini Catalogue air curtains radiant heaters fan heaters convectors controls

The future is in the air

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Original instructions SWX C/D NO DE ES... 26

COR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

WINGS. design Massimo Giorcelli

Development of an advanced control system for chillers

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L

Electric Water Heaters. The STRENGTHS of the product range in detail:

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

CHILLED BEAM CASSETTE IQ STAR LYRA

External venetian blinds

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

TERMOREGOLAZIONE THERMAL REGULATION

Constant Temperature Waterbaths

Comfort Air Curtains with in-built dynamic advertising

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

SIRENE ANTINCENDIO E EVACUAZIONE FIRE ALARM AND EVACUATION SOUNDERS

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INDEX. Installation recommendation

ROOFTOP PACKAGED AIR CONDITIONERS

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

CHATTANOOGA JUNIOR STAR

Heating System ENERGY EFFICIENT ELECTRIC HEATING YEAR WA RRAN T Y. Designed and Engineered by TERMS & CONDITIONS APPLY

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

HD3D Forced-Air Heater

INDEX. Installation recommendation

Technical Information HXV - HRV Ventilation

electronics Protection

Original instructions. Thermoplus PL RU

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

Technology for life. Unit heater LH

Installation, operation and maintenance guide for window models

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

NEW RANGE OF WARM AIR CURTAINS

WODA. design Paolo Schianchi

ROBUST Electric fan heaters for demanding environments

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

E Z S E R I E S " W X 16" H

Küba SG commercial

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

CDP 40 SWIMMING POOL DEHUMIDIFIER

16 / 20 / 28 / 40 / 56

42AM. Air heaters PRODUCT SELECTION DATA

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Recessed. Air Curtain. Fig 1. Recessed air curtain

Installation, Operation & Maintenance Instructions Document Ref:

Metropolitan high output natural and powered trench heaters

Energy-efficient heat source provides comfort in large rooms

STR-600 Impact Dryer

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

GENERATORI D ARIA CALDA PENSILI A COMBUSTIONE INDIRETTA INDIRECT COMBUSTION SUSPENDED SPACE HEATERS

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

Transcription:

Fan Heater 6-15 3 6 15 kw Riscaldamento elettrico 5 modelli Fan heater 6-15 Efficient fan heater for medium size premises Applicazioni 6-15 è una gamma di termoventilatori molto silenziosa ed efficiente per l'uso stazionario. Sono destinati al riscaldamento, l'asciugatura e la ventilazione, ad esempio in officine, palazzetti dello sport, sale riunioni ed essiccatoi. L'unità di miscelazione (opzionale) consente la combinazione di riscaldamento e ventilazione attraverso la miscelazione dell'aria di ritorno e l'aria esterna. Comfort Frico's fan heaters are extremely quiet and quickly provide comfortable heating. Fan heater is delivered with adjustable wall mounting brackets which makes it possible to direct the airflow where it is required. Funzionamento ed economia Frico's fan heaters have a long life and providing fast and effective heating at a low cost. Simple installation and a minimum of maintenance also reduce costs and the risk of faults. Specifiche del prodotto Low sound level. Supplied with wall bracket that makes it possible to direct the airflow down and to the side. Integrated thermostat with setting range +5 +35 C, possibility to connect an external thermostat. External control panel (ordered separately) with master/slave function, for up to six units gives good and simple control. SE135 can be connected to both 440V3~and 500V3~. Wide range of controls and accessories. Mixing cabinet, that combines heating and ventilation, is available as an accessory. The fan heater is also available in outputs 20-30 kw, see the separate chapter. Corrosion proof housing made of hot zinc-plate and powder enameled steel panels. Colour: RAL 9016, NCS S 0500-N (white). Design The fan heater has a classic clean design in white enamelled sheet steel. Il design e le specifiche sono soggetti a modifica senza preavviso. 2013-09-27

Fan Heater 6-15 is delivered with adjustable wall mounting brackets which make it possible to direct the air flow for optimal heat distribution. Mixing cabinets, available as an accessory, combine heating and ventilation. The mixing cabinet saves energy by mixing return air with fresh air in individually preset proportions. Fan heaters are usually the least expensive option to permanently heat premises. They give a very high output per invested pound (W/ ) and at the same time are easy to install. The fan heater is the perfect choice to heat stores.

Fan Heater 6-15 Technical specifications Fan Heater 6-15 kw 3 Type Output steps [kw] Airflow [m³/h] Sound level* 1 [db(a)] t* 2 [ C] Voltage [V] Amperage [A] HxWxD SE06 0/3/6 900/1300 39/47 20/14 400V3N~ 8.7 520x450x510 21 SE09 0/4.5/9 900/1300 39/47 30/21 400V3N~ 13 520x450x510 22 SE12 0/6/12 900/1300 39/47 40/28 400V3N~ 17.3 520x450x510 22 SE15 0/7.5/15 900/1300 39/47 50/35 400V3N~ 21.7 520x450x510 22 SE135 (convertible) 0/5/10 0/7/13.5 900/1300 39/47 34/23 45/31 440V3~*³ 500V3~ 13.4 15.6 520x450x510 23 * 1 ) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m 2. * 2 ) t = temperature rise of passing air at maximum heat output at lowest/highest airflow. *³) Can be connected to 440V3~ and 500V3~. Weight [kg] Protection class: IP44. Conformità CE. Dimensioni Staffa 100 ø7 520 90 ø14 ø6,5 450 510 Mixing cabinet (accessory) B C D G A E F A B C D E F G 660 430 365 420 445 445 420 Air throw 6-15 kw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 [m]

Fan Heater 6-15 Montaggio e collegamento Muro Mounting The fan heater is mounted on the wall with a wall bracket making it possible to direct the airflow down and to the side. For minimum dimensions with permanent installation, see diagram 1. 30 min 300 Muro Installazione con unità di miscelazione L'unità di miscelazione PBS è disponibile come accessorio e consiste in una griglia da parete esterna e un telaio a parete. Il telaio a parete e la griglia da parete esterna sono costruiti o avvitati sulla parete. Successivamente vengono montate l'unità di miscelazione e l'unità. Vedere lo schema 2. L'unità di controllo manuale (PHR01, opzionale) consiste in una leva, una staffa a parete, una sfera di controllo e due giunti associati. Tra i giunti viene utilizzata una sospensione pull-rod (non inclusa). Ceiling min 300 min 1000 Electrical installation The fan heater is intended for permanent installation. Supply voltage is 400V3N~. must be supplemented with control panel. The knockouts at the rear of the unit are used to connect accessories. SE135 can be connected to both 440V3~ and 500V3~. 7,5 15 min 1800 Fig. 1: Minimum distance for fixed installation. Fig. 2: Cutaway view of with mixing cabinet.

Fan Heater 6-15 Opzioni di controllo Fan speed and thermostat control 6 15 kw is supplied with integrated thermostat (+5 +35 C), but can also be controlled using an external two-step thermostat. Selection of the operating mode is done using the external control panel. Delay relays between the output groups prevent simultaneous connection. RTI2, electronic 2-step thermostat, IP44 KRT2800, 2-step capillary tube thermostat, IP55, control panel, controls up to six units Control of mixing cabinet The mixing cabinet combines heating and ventilation by mixing return air with fresh air in appropriate proportions. Damper control is ordered separately. PHR01, control lever, manual damper control PSA01, automatic damper- and temperature control PSM01, damper motor, is used in combination with PSA01 when several mixing cabinets should be controlled. Automatic temperature control The heat can be decreased according to demand, for example at night or weekends. Switches between day and night mode. PTA01, automatic temperature control Controlli e accessori RTI2, termostato elettronico a 2 stadi Termostato a 2 stadi con controllo tramite processore e con manopola nascosta. Range di temperature +5 +35 C. Tensione collegamento 230V, 2 contatti puliti. Max. corrente: 16/10 A (230/400 V). IP44. KRT2800, 2-step capillary tube thermostat 2-step capillary tube thermostat with concealed dial. Setting range 0 +40 C. Max. breaking current: 16/10 A (230/400 V). IP55., control box The desired output and fan speed can be set on the control box. Up to 6 units can be controlled by one control box. Protection class: IP44. PTA01, automatic temperature control PTA01 can be used to lower the heat when necessary (1 10 C), for example at night or weekends. The control consists of an electronic timer and thermostat with an external sensor. The timer alternates between day and night mode. Protection class: IP55. PHR01, control lever for mixing cabinet Used with the mixing cabinet, if you wish to control the damper manually. The pull-rod (not included) for the lever should have a diameter of 8 mm. PSA01, automatic damper and temperature regulator Used on the mixing cabinet. Lowers the temperature and reduces the amount of outdoor air during periods with a low requirement. Consists of timer (weekly timer), thermostat with external sensor, potentiometer and damper motor. Exhaust air fans can possibly be controlled from the automatic system. One damper motor (PSM01) included. IP55. PSM01, damper motor Used in combination with PSA01 when several mixing cabinets should be controlled. (1 damper motor is included in PSA01.) Protection class: IP54. Per ulteriori informazioni e opzioni, vedere la sezione "Sistemi di controllo".

CBT 2h 2 1 1h 4h Fan Heater 6-15 PBS01, mixing cabinet Saves energy by mixing return air with fresh air in preset proportions. The mixing cabinet is delivered with a wall frame and outer wall grille. Read more under "Mounting and connection". PLR15, air director The air director directs the airflow vertically or laterally. PLR is snapped on the front of the heater. Torsional (turning) angle 0 35. PFF15, exhaust air fan Can be used with fan heater/mixing cabinet to obtain good ventilation. Airflow approx. 1400 m³/h. Protection class: IP54. Fig. 3: Mixing cabinet PBS01 with. PTRP, drying room kit Consists of exhaust air fan TTF140 with flexi hose and connection sleeve, thermostat KRT1900 and timer CBT. The exhaust air fan works alternately with, for example, a fan heater, which gives the shortest possible drying time and minimal energy consumption. Supplemented with a fan heater from the range with output 6-12 kw. TTF140 KRT1900 CBT Fig. 4: Drying room kit PTRP. RTI2 KRT2800 PTA01 PSA01 Type Description HxWxD RTI2 Electronic 2-step thermostat 155x87x43 KRT2800 2-step capillary tube thermostat 165x60x57 Control box for SE06 SE15 160x120x96 PTA01 Automatic temperature control 185x215x115 PBS01 Mixing cabinet for SE06 SE15 660x430x365 PHR01 Control lever PSA01 Automatic damper and temperature control 305x215x115 PSM01 Damper motor 180x100x70 PLR15 Unità di comando dell'aria for SE06 SE15 355x355x60 PFF15 Exhaust air fan for SE06 SE15 PTRP Drying room kit without fan heater

Fan Heater 6-15 Schemi elettrici Fan speed and thermostat control SE06-15 230V ºC L 1 L 2 L 3 L 1 L 2 L 3 440V 500V L 1 L 2 L 3 6-15 kw 440V 3~ 500V 3~ M kw SE 06 ºC L 1 L 2 L 3 L 1 L 2 L 3 L 1 L 2 L 3 N 12345678910111213141516 400V 3N~ 12345678910 kw kw SE 09-15 1 2 3 4 a bcd 2 3 b c 400V3~, control box X X X X X X 123 4 X X X ½ 1 12 1 ½ Factory setting 1 2 3 9 1112 1415 L 1 L 2 L 3 N 230V3~ RTI2, termostato elettronico a 2 stadi Sensor 230V~ L N 1 2 3 4 5 6 7 L L N 230V3~ 230V3~ >t C Hi >t C Lo 230V~ RTI2 1 2 3 1 2 3 KRT2800, 2-step thermostat -1-4 C KRT 2800 C Il design e le specifiche sono soggetti a modifica senza preavviso.

Fan Heater 6-15 Schemi elettrici Wiring of accessories to 6-15 Note! Remove the two internal fuses 6.3A in the slave unit(s). High speed SE06-15 7 SE06-15 Medium speed 6-15 kw SE06-15 Low speed SE06-15 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 7 SE06-15, 8+ control box 1 2 3 4 5 6 7 8 9 10 Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 7 SE06-15 8+ 6+ RTI2, termostato elettronico a 2 stadi 1 2 3 4 5 6 7 8 9 10 RTI2 RTI2 1 2 3 4 5 6 7 L N Note! Remove the two internal fuses 6.3A in the slave unit(s). SE06-15 1 2 3 4 5 6 7 8 9 10 11121314 1516 7 SE06-15 1 2 3 4 5 6 7 8 9 10 11121314 1516 7+ KRT2800, 2-step thermostat 1 2 3 4 5 6 7 8 910 4+ KRT 2800 KRT2800 1 2 3 1 2 3