Installation, operation and maintenance guide for window models

Similar documents
Installation, Operation and Maintenance Manual

Operation and maintenance instructions

XB-EFA-8L-BK & XB-EFA-8R-BK

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Bruksanvisning Directions for use

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

USER S MANUAL. VKP Series INLINE FAN

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

AIR CURTAIN T SURFACE MOUNTED RANGE

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Owner s Guide and Installation Manual

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

6 Assembling the Blades

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

EU declaration of conformity Cotes A/S Industrivej 31A DK-4230 Skaelskoer VAT no. DK CE Declares at its own l

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

AIR CURTAIN HX RECESSED RANGE

Owner s Guide and Installation Manual

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Fan heater Panther Powerful fan heater for large premises

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Owner s Guide and Installation Manual

Topvex SF02-SF12 Air Handling Unit

HEAT RECOVERY VENTILATOR

G Installation manual Solitude - dmev unit

for Ultima-Tig and for Ultima-Tig-Cut

Owner s Guide and Installation Manual

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Technical Information HXV - HRV Ventilation

Operations Manual VCS/VCR/VLS

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Topvex SR03, SR04, SR06 Compact Air Handling Unit

CE Marking and Technical Standardisation

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

VEX250H with rotary heat exchanger and EXact control system

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Owner s Guide and Installation Manual

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Controlled mechanical ventilation GB 03

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Original instructions AR

British Standards for Machinery Guarding

Axial fans The right fan for every house

Introduction. Overview

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Lawnmowers, pedestrian controlled (combustion engine powered)

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

ISCG90SS _03 ISCG90SS

EVP61/91/101/121. Extractor. Installation, use and maintenance.

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

WHHR Midi & Midi Lite

Operations Manual VCC

Electromagnetic compatibility (EMC)

SLIDER CASEMENT AIR CONDITIONER

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

Installer manual AG-WL10

Owner s Guide and Installation Manual

TSL hand dryer. installation + maintenance

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

e Heater/Exhaust Fan/Light User s Guide

Centrifugal inline fans

e Bath Fan with Light User s Guide

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Installation and Maintenance

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

KK70 Silent. Installation and Operating Instructions L V001

Fan heater Panther WALL MOUNTED FAN HEATER

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

EDD61 & EDD91 Extractors

EVG Extractors. Manual for Installation, Use and Maintenance

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

INCREASE YOUR LAB EFFICIENCY

e Bath Fan with Light User s Guide

AIR CURTAIN COMPACT 2 SURFACE MOUNTED RANGE

Novenco Air Handling Units

Installation and Maintenance

Lawnmowers (pedestrian controlled electric mains-powered)

C 271/32 Official Journal of the European Union

Transcription:

Installation, operation and maintenance guide for window models Rev. 2014.06.25 Page 1 of 23

Table of content 2.0.0 GENERAL INFORMATION... 3 2.1.0 PREFACE... 3 2.2.0 AREAS OF USE... 3 2.3.0 INCORRECT USE... 3 2.4.0 SCOPE OF DELIVERY... 3 2.5.0 MAIN COMPONENTS:... 4 FIGURE 2: MAIN COMPONENTS... 4 FIGURE 3 MAIN COMPONENTS... 5 3.0.0 INSTALLATION OF UNIT... 6 3.1.0. EXTERNAL DIMENSIONS... 6 3.2.0 WALL/WINDOW INSTALLATION... 7 4.0.0 PLACING THE UNIT... 11 PLACING THE UNIT (CONT.)... 12 5.0.0 SERVICE... 13 5.1.0 FILTER CHANGE... 13 5.2.0 REMOVING FILTERS AND EXCHANGER... 14 6.0.0 CONNECTING MAINS ELECTRICITY... 17 6.1.0 CONNECTION... 17 6.2.0 WIRING DIAGRAM... 18 7.0.0 TECHNICAL SPECIFICATIONS... 19 7.1.0 SOUND TEST... 20 8.0.0 PRINCIPLE OF OPERATION... 21 8.1.0 DESCRIPTION... 21 9.0.0 OPERATION... 22 9.1.0 REGULATING AIR VOLUME... 22 9.2.0 REGULATING WARMTH... 22 9.3.0 MASTER/SLAVE... 22 10.0.0 DECLARATION OF COMPLIANCE... 23 Page 2 of 23

2.0.0 General information Turbovex TX 350A and TX 75A are decentralized ventilation units with integrated heat recovery. 2.1.0 Preface This installation and operation guide contains technical information and details of installation and maintenance of the unit. 2.2.0 Areas of use Window models are designed for comfort ventilation for institutions, canteens, offices and conference rooms etc. 2.3.0 Incorrect use The window models are not designed for local exhaust ventilation, and are therefore not suitable for this purpose. 2.4.0 Scope of delivery TX window models are supplied with the following main components: 1. Turbovex TX window model 2. TX electronic controller Figure 1 Deliverables Page 3 of 23

2.5.0 Main components: 1. Intake Air 2. Exhaust Air 3. Extract Air 4. Supply Air 5. Counterflow heat exchanger 6. Supply Air Fan Figure 2: Main components 4 7. Extract Air Fan 8. Bypass Damper 9. Electrical heater 10. Filter 11. Main PCB 12. TX Controller 6 9 10 5 10 8 3 11 12 3 Page 4 of 23

Figure 3 Main components 1 2 7 Page 5 of 23

3.0.0 Installation of unit 3.1.0. External dimensions Intake zone Dimensions (mm) TX350A A (Height) 1400 B (Width) 662 C (Depth) 334 D (Mounting Dimension) 260 E (Hole Height) 122 F (Hole Distance Upper) 322 G (Hole Distance Lower) 20 H (Hole Width) 597 Exhaust Zone Minimum required distance to walls, floor and ceiling is 70 mm. Page 6 of 23

3.2.0 Wall/window installation Internal reinforcement is built into the sides within the marked areas. Holes can be drilled in these areas as required for installation. Safe area for holes Dimensions: TX350A H 10 I 235 J 105 K 90 L 335 M 220 N 205 P 336 R 1400 Page 7 of 23

Plane cross-section for window/wall Page 8 of 23

Vertical cross-section, upper part Page 9 of 23

Vertical cross-section, lower part Page 10 of 23

4.0.0 Placing the unit The unit is usually placed in the wall by a window. This position makes the most of the coanda effect, which circulates fresh air well into the room. This gives the air longer to mix with the existing air in the room, avoiding drafts. The location of the supply grille and extraction provide optimum circulation in the room. Page 11 of 23

Placing the unit (cont.) Place the unit with the edge of the cabinet flush with the inside of the wall in the room. Ensure free air passage in both directions These surfaces should be flush Page 12 of 23

5.0.0 Service 5.1.0 Filter change We recommend changing the filters and carefully cleaning the exchanger 2-4 times a year. Upper keyhole Lower keyhole NOTE! Disconnect from mains electricity before opening the front Use a 6mm Allen key Page 13 of 23

5.2.0 Removing filters and exchanger Page 14 of 23

Change upper filter with inner door open. Change lower filter with inner door closed. Page 15 of 23

Remove inner door and filters to be able to lift out the heat exchanger. Clean heat exchanger carefully using a vacuum cleaner with a soft brush head. Page 16 of 23

6.0.0 Connecting mains electricity 6.1.0 Connection Cable grommet holes Terminal clamps for connecting mains electricity Note! Connection of mains electricity must be performed by an authorised electrician Note! A circuit breaker must be mounted prior to the ventilation unit Page 17 of 23

6.2.0 Wiring diagram Connect Turbovex unit according to wiring diagram Page 18 of 23

7.0.0 Technical specifications TX 350A Unit Dimensions: Height 1400 mm Width 662 mm Depth (without insulation and grille) 336 mm Weight: 47 Kg Capacity: Min. 170 m³/h Max 330 m³/h Forced 730 m³/h Noise level: Min. 26 db(a) Max. 35 db(a) Forced 55 db(a) Filter: M5 Filter class Energy consumption (unit): 13.8 W Min. 311 J/m³ 28.6 Watt Max. 315 J/m³ 167 Watt Forced 826 J/m³ Output (motor): 2 x 82 W Electricity supply 1 ~ 230 / 50 V / Hz Temperature efficiency: 90,5 % Electric heater 650 Watt The airflow indicates the balanced air change in relation to motor voltage stated in m 3 /h. The standard unit setting is max. (see table above). If forced operation is required, please contact the dealer. Noise level is stated in db(a) in relation to air change, measured at a distance of 1 metre from and 1,2 m below the supply air grille. For comparison, a whisper is equivalent to 30 db(a), ordinary speech 60 db(a) and urban traffic approx. 90 db(a). Temperature efficiency degree at the heat exchanger is stated in % and is the relationship between the temperature differences achieved and the maximum achievable temperature difference, i.e. the outdoor temperature minus supply temperature divided by the outdoor temperature minus room temperature, converted to percent. Page 19 of 23

7.1.0 Sound test Sound test performed in our laboratory on 12-10-11 Principle Sketch Result: 30 db 290m³/h consumption 23,4W (290 J/m³) 35 db 345m³/h consumption 30W (313 J/m³) Page 20 of 23

8.0.0 Principle of operation 8.1.0 Description The unit contains a counterflow heat exchanger and two fans, which enable the extraction of warm air from a room and concurrent supply of cold fresh air from outdoors. Heat exchange occurs by using the warmth from the extracted air to heat the cold fresh air. Airflow: Supply air fan (1) draws in fresh air, passes it through the filter (3), the heat exchanger (2), up through the fan blade, out through the louvres in the top and in to the room. The extract air fan (4) draws air from the room through the louvres in the bottom and sides, up through the filter (5), through the heat exchanger (2), down through the fan blades, which blows it out at the bottom of the back. 1 3 Bypass: When the bypass damper (6) opens, the air is drawn through the unit, bypassing the heat exchanger and direct into the room. Regulation: The temperature desired is set on the control panel for the supply air. A sensor registers the actual temperature of the supply air, and if it is lower than the set value, the control system will turn down the supply air volume. The air will thus be warmer as it passes through the heat exchanger. 2 5 46 Page 21 of 23

9.0.0 Operation 9.1.0 Regulating air volume See also the user guide enclosed for the TX electronic controller. The unit has 2 operating settings. One for daytime, which gives the dimensioned air volume the unit is set for by the factory, and one night time operation, which runs slower, to save energy at night. NB! If air volume is regulated by a CO2 sensor, the unit will adjust its speed according to conditions in the room. NOTE! Units with electrical comfort heaters always have a run-on time of approx. 80 seconds. 9.2.0 Regulating temperature See also the user guide enclosed for the TX electronic controller. The temperature required is set on the control panel. We recommend that the temperature should not be set higher than the room temperature. Fresh air temperature should be 2-3 degrees below room temperature to achieve the best circulation in the room. When the unit is stopped, the last temperature setting is automatically saved, and the unit will start using that setting. The unit has a fully-automatic by-pass system, which directs the air past the exchanger when the temperature permits. 9.3.0 Master/slave To use this function, a PCB board is required. Contact your dealer. 5 slaves can be connected to one master. This means that one unit can be used to control 5 other units, so that all 6 units run uniformly. See the user guide for correct master/slave setup. The unit is programmed as a master as standard. Page 22 of 23

10.0.0 Declaration of compliance Manufacturer: Name: Address: Industrivej 45 DK-9600 Aars Country: Denmark Tel: +45 96 98 14 62 Dealer: Name: Address: Industrivej 45 DK-9600 Aars Country: Denmark Tel: +45 96 98 14 62 hereby declares that Product: Name: TX 350A Serial no.: 300-000-000 Name: TX 150A Serial no.: 150-000-000 complies with Council Directive of 17 May 2006 on harmonisation of member state legislation on electrical materiel intended for use within certain voltage ranges (2006/42/EC) has been manufactured in accordance with the following national standards. which implement a harmonised standard: DS/EN 12100-1/A1:2009 Safety of Machines - Basic concepts, general principles for design - Part 1: Basic terminology and methodology (ISO 12100-1:2003) DS/EN 12100-2/A1:2009 Safety of Machines - Basic concepts, general principles for design - Part 2: Technical principles (ISO 12100-2:2003) DS/EN 60269-1/A1:2009 Low voltage fuses Part 1: General requirements (IEC 60269-1-1998) supplement A1:2005 to DS/EN ISO 13857:2008 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs DS/EN 61000-6-1:2007 Electromagnetic compatibility (EMC) Part 6-1: Generic standards, Immunity for residential, commercial and light-industrial environments DS/EN 61000-6-3:2007 Electromagnetic compatibility (EMC) Part 6-3: Generic standards, Emissions standards for residential, commercial and light-industrial environments DS/EN 61000-6-4:2007 Electromagnetic compatibility (EMC) Part 6-4: Generic standards, Emission standard for industrial environments Aars Date: Production Technologist: Arne Christensen Page 23 of 23