Firefox 12B (Boiler Model) CE V.11

Similar documents
H E R A L D 8 0 B. Installation and Operating Instructions

C O N S O R T 9. Installation and Operating Instructions

VEGA 100 CLEAN BURN II INSTALLATION AND OPERATING INSTRUCTIONS (to be left with the householder)

H E R A L D 1 4 C E V. I I

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Inset Chevin 20B. Installation and Operating Instructions. JINCHW09 Rev A 12/05/14

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

CHARNWOOD COUNTRY 6 FT

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

INSTALLATION AND OPERATION MANUAL

THE MUCH WENLOCK. Operating Instructions for Freestanding Much Wenlock Stove with Boiler

Firebird Smoke Exempt Inset Stove

Stockton. Clean-burn stove. MODELS: 3 MF/4 Wood/4 MF/5 MF. Installation and Operating Instructions. For Use in Great Britain and Eire

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Inset Telford 8. Multi-Fuel Inset Stove Installation and Operating Instructions. JINTDI08 Rev C 21/05/14

charnwood country 4MKII Operating & Installation Instructions

charnwood Operating & Installation Instructions

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

charnwood Operating & Installation Instructions

Newton Multi Fuel 5kW Space Heating Stove

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

THE SEVERN. Operating Instructions for Freestanding Severn Stove with Boiler

Ludlow Wood Burning Smoke Exempt Stove

Yeoman CL. High Output Boiler Stove YM-CL8HB. Instructions for Use, Installation and Servicing

Free Standing Stove. Technical Manual. 8 Series. User and Installation Instructions. For use in GB & IE (Great Britain and Republic of Ireland).

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

FM5 Freestanding Multifuel Dry Stove

Shawbury Wood Stove. (Smoke Exempt)

Instructions for: Installation/Operating/Maintenance/Servicing JINHHD REV A 23/05/2018 1

Instructions for Use, Installation & Servicing

Stockton 7 Inset. High Output Boiler Inset. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Novus. Multifuel Stove Model Novus. To be retained by the user for future reference. Thank you for purchasing an ACR Heat Products stove

High Output Boiler Stoves

Little Wenlock Classic

Newton Multi Fuel 8kW Space Heating Stove With Boiler

Operation instructions

Oakdale. Multifuel Cast Iron Stove Model FB1MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

View. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Malvern II. Multifuel Stove Model MAL2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Ashdale. Multifuel Cast Iron Stove Model FB2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

charnwood Operating & Installation Instructions

View. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

View. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Chevin Inset 5 MKII. Model: CVSCHI05FM. Instructions for: Installation/Operation/Maintenance/Servicing

View 7 Inset. High Output Boiler Inset. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Yeoman CL. Free Standing Stove

High Output Boiler Stove

charnwood Operating & Installation Instructions

Troubleshooting Guide

High Output Boiler Stoves

Ludlow Non-Boiler (Multi-Fuel)

Neo. Multifuel Stove Model Neo 1 / Neo 3. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Birchdale. Multifuel Cast Iron Stove Model FB4MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Installation & Operating Instructions

Stockton Double. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

charnwood SLX45MKII MULTI-FUEL Operating & Installation Instructions

Website:

Huntingdon

Huntingdon. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

charnwood I S L A N D Operating & Installation Instructions

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

charnwood Operating & Installation Instructions

Oscar Solid Fuel Stove

Kensal 20/33/40/40SL/60

Hanwood Wood Stove. (Smoke Exempt)

Yeoman CL. Free Standing Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Dorrington Wood Stove

Huntingdon

charnwood country 16b multi-fuel Operating & Installation Instructions

charnwood Operating & Installation Instructions

Stockton 8 & 11 Double

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Westbury Wood Stove. (Smoke Exempt)

Stockton Milner Brick

Stockton 7&8. Inset Convector Cassette. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Elise. Inset Convector Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Brunel. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

TRH 45 MK4 SOLID FUEL ROOM HEATER USER AND INSTALLATION INSTRUCTIONS

Langdale. Woodburning Cast Iron Stove Model FB6WB. To be retained by the user for future reference

Vogue. Wood Burning & Multi-Fuel Freestanding Stove Range. Instructions for Use, Installation & Servicing

Yeoman CL Milner Brick

Yeoman CL7. Inset Convector Stove. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

ASPECT 4/4 COMPACT ASPECT 5/5 COMPACT ASPECT 5 SLIMLINE ASPECT 6 ASPECT 7 ASPECT 8 SLIMLINE ASPECT 8 ASPECT 9 ASPECT 14 WOODBURING STOVE MODELS

Installation Instructions. Rayburn 300W Wood Burning Cooker

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

Regency. Free Standing Stove. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Riva Vision. Wood & Multi-fuel Free Standing Stove. Models: Instructions for Use, Installation and Servicing

Lismore Boiler Solid Fuel Stove

Cara+ Solid Fuel High Output Boiler. Insert Stove

Marvic. multifuel. English

Stockton 7 & 8. Inset Convector Stove MODELS: 7125/7126. Instructions for Use, Installation and Servicing

BERRINGTON SOLID FUEL BOILER STOVE

Riva. Woodburning & Multi-fuel* Cassette Range. * Multi-fuel when fitted with a Multi-fuel grate. Instructions for Use, Installation & Servicing

stove Tested to EN BROSELEY CO Alarms: as the

Stockton. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Transcription:

Firefox 12B (Boiler Model) CE V.11 Multi-fuel central heating stove Installation & operating instructions. To be left with user. This appliance must be installed by a competent person and must comply with national building regulations and local by-laws. Unless the installer is qualified to approve the installation, then approval must be sought from your local building control officer. It is an offence under UK law not to comply with this advice. After installation the appliance should be ready for use and instruction as to use and control given.

Technical Specification This appliance is suitable for continuous use WOOD (Moisture less than 20%) Mean efficiency 76% Heat output 13.6 KW Output to water 7.4 KW Output to room 6.2 KW Mean CO at 13% O2 0.83 Mean flu gas temp 339 Flue gas mass flow 7.9 g/s ANCIT Mean efficiency 75.1% Heat output 12.8 KW Output to water 8.0 KW Output to room 4.8 KW Mean CO at 13% O2 0.39 Mean flue gas temp 354 C Flue gas mass flow 7.3 g/s Minimum ventilation requirements at 13.6 KW 748 Cm (12.02 inch) Please note: No extractor fans to be fitted in same room as appliance. This appliance should not to be used in a shared flue. Safe distance from combustible materials: Rear 175mm Sides 80mm Assembly Instructions Please read carefully the manufacturers will not accept responsibility for any fault due to incorrect installation. The Firefox 12B is supplied as standard with a thermostatically controlled air supply at the rear of the stove. The stove legs require fitting to accommodate the thermostat controls. The position of the flue collar will be determined by the installer for either top or rear outlet. Supplied is a half collar this fits beneath the flue collar when installing as top connection only and acts to impinge gas flow. Note: the open end of the half collar faces rearwards (see illustration on page 2). The half collar is not required on rear connection. A blanking plate will cover the outlet not used and acts as a clean out point. No sealants are required as ceramic fibre rope seals are fitted to flue collar and blanking plate.

Assembly Instructions Parts List 1 FFX12003 Stove Top 2 FFX12002 Stove Base 3 FFX12004L Stove Door Left Hand 4 FFX12004R Stove Door Right Hand 5 FFX12003E Expanding Flange (not shown) 6 FFX12005 Grate Outer 7 FFX12005B Grate Inner Bars (10 pcs) 8 FFX12007F Flue Blanking Plate (not shown) 9 FFX12007 Half Collar Diffuser 10 FFX12024 Air Wash Deflector Plate 11 FFX12020 Primary Air Slide (2 pcs) 12 FFX12029 Operating Tool (not shown) 13 FFX12011 Front Bar 14 FFX12010 Leg (4 pcs) 15 FFX12008 Flue Collar 16 FFX12017 Door Catch (not shown) 17 FFX12016H Door Handle Holder (2 pcs) 18 FFX12016 Door Handle (2 pcs) (not shown) 19 FFX12028 Hinge Pin (4 pcs) 20 FFX022T Knob 21 FFX022B Knob Set (2 pcs) 22 FFX12005R Grate Rocker Bar (not shown) 24 FFX12014 Ash Pan (not shown) 25 FFX12021 Air Slide Guide Plate (4 pcs) 26 FFX12023 Secondary Air Slide 27 FFX12032 Heat Shield Primary (not shown) 28 FFX12033 Heat Shield Secondary (not shown) 29 FFX12019 Glass Clip (8 pcs) (not shown) 30 FFX12012 Thermostat Assembly 31 FFX12013 Thermostat Knob 32 FFX12026 Door Seal (not shown) 33 FFX12027 Glass Seal (not shown) 34 FFX1 Heat Resistant Mitten (not shown) 35 FFX12018 Door Glass (2 pcs) 36 FFX12034 Stove Body 37 FFX12035 Front Panel 38 FFX12036 Deflector (not shown) 39 FFX12038 Grate Pivot Block (not shown)

Installation Instructions This appliance has been extensively tested for safety and efficiency. Do not attempt to modify it. Always use genuine parts as recommended by your supplier. Failure to adhere to this advice could invalidate your guarantee. This appliance must be installed in compliance with current building regulations, local authority by-laws and European and National standards. Site conditions will vary, a certain amount of customisation of installation will be required. To achieve best performance of installation refer to Approval Document J of building regulations for guidance. If the installer cannot self certify the installation then your local building control department must approve the installation. Members of the following schemes can self certify the installation: HETAS LTD (www.hetas.co.uk) 01462 634 721 BESCA LTD (www.besca.org.uk) 0800 652 5533 APHC (www.aphc.co.uk) 02476 470 626 HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met. Handling Adequate facilities must be available for loading, unloading and site handling. Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash immediately with plenty of water. Asbestos This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment. Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

Installation Instructions Continued Chimney The chimney should be checked as to conformity to building regulations; it must be swept before installation. This will highlight any blockages or constructional problems. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire. The chimney flue should not be less then 175mm diameter and not more than 230mm diameter. If square it must have an equivalent cross section. If these requirements are not met then a suitable method of lining should be adopted. Connection to an approved pre-fabrication flue is acceptable but must comply with building regulations. Flue draught Water Gauge- Minimum 1.2mm / Maximum 2.5mm The flue draught should be checked under high output. A flue stabiliser should be fitted if it exceeds the maximum draught. If the flue draught is too low then the reason for this should be investigated. The performance of the appliance will be compromised if the flue draught is out of the recommended limits. Chimney Connection A short length of stove pipe will be required to connect the appliance to the chimney. There are various ways of sealing the pipe to the chimney. A register plate is most common. The length of the stove pipe will be dictated by the height of the register plate in the chimney opening. The stove pipe will NOT be smaller in diameter than the manufacturers stated outlet diameter (6 inch-150mm internal diameter), and will be made of Vitreous Enamelled Mild Steel with nominal thickness of 1.2mm or 316 Grade Stainless Steel. The stove pipe should not impinge on any gathers or brickwork and not be closer than 76mm to any chimney walls. Any changes in direction of the flue should not be less than 45 degrees; if any 90 degrees bends are required then a swept elbow or 2 x 45 degree elbows should be used. The elbows require a clean out door at the change in direction. Provisions must be made for access to the chimney connection i.e. soot door. No horizontal run shall be more than the diameter of the flue outlet of the appliance, 6 inches (150mm).

Installation Instructions Continued Air supply This appliance requires 4730mm 2 (7.4 inch 2 ) of un-obstructed free air supply. If a draught stabilizer is fitted then the requirement is 8810mm2 (13.65inch 2 ) Consideration should also be made for other appliances ventilation requirements in the same space. Clearances The Firefox 12B can be recessed into an inglenook or fireplace but must have a permanent free air gap of at least 150mm to the sides and top, and a minimum of 100mm at the rear. This allows access for cleaning and maintenance and free passage of air for the thermostatically controlled air vent. This appliance must be placed on a non-combustible hearth. This must be constructional or at least 125mm thick and should be in accordance with current building regulations. All walls closer than 300mm should be a minimum of 75mm thick and be of non-combustible materials. If this appliance is to be placed on a floor with inadequate load bearing capacity then specialist advice must be sought on re-enforcement, e.g. load distribution plates The minimum distance to combustible materials is 175mm to sides and rear, and 600mm from top and stove pipe. No furniture is to be placed nearer than 900mm from any surface of the stove or stove pipe. Electrical connections The installation of any electrical services during the installation of this boiler and the associated heating system must be carried out by a registered competent electrician and in accordance with the requirements of the latest issue of BS 7671. It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BS EN 15287-1:2007 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.

Boiler System The design and installation of the heating system will be unique to each application. A qualified plumbing and heating engineer must be responsible for all calculations, design and installation. The manufacturers cannot be held responsible for any losses due to incorrect specifications of the heating system. The stove must NOT be connected to a sealed heating system or unvented HW cylinder. If the stove is to be linked to an existing system then a neutralizer must be incorporated as a common link. The neutralizer will come with its own instructions as to use. The stove must be connected to a double feed indirect water cylinder using 28mm flow and return pipes, rising continuously from the boiler to the cylinder. The cylinder with a heat soak radiator of at least 2kW must be positioned above the stove. An open cold feed and expansion cistern must be fitted with separate cold feed and vent pipes. These pipes must be un-valved. The vent pipe should be 22mm diameter and rise continuously from the boiler. The vent pipe can be formed in the primary flow. On heating and hot water installations, a semi-pumped system should be used with gravity circulation to the hot water cylinder. One 2kW heat soak radiator fitted will dissipate heat when central heating is switched off. Use all four tappings when using separate gravity and pumped heating loops. The flow and returns should be taken diagonally across opposite sides of boiler. If only two tappings are to be used on a common flow system they should be taken diagonally opposite and the remaining tappings should be plugged. An injector T should be fitted on the primary return from the circulation pump. The gravity flow pipe should have a high limit thermostat fitted set at 90 degrees Celsius. This will override the circulation pump control and dissipate excess heat around the radiator circuit. The fitment of a low limit thermostat on the return pipe from the hot water cylinder close to the boiler is recommended. This should maintain the return water temperature above 45 degrees Celsius preventing activation of the circulation pump until the gravity circuit is up to temperature. It is important to fit a corrosion inhibitor to the water system. Further guidance is available from the following sources: BS EN 14336:2004: Heating Systems in Buildings. Installation and commissioning of water based heating systems. BS EN 12828: 2003; Heating Systems in Buildings. Design of water based heating systems. BS EN 12831: 2003; Heating Systems in Buildings. Method for calculation of the design heat load.

Typical Installation for Integral Boiler

Commissioning On completion of installation check that all cements have hardened. All joints in the connection between the stove and the chimney must be made gastight using fire cement and where necessary fire-proof rope infill. A small fire can then be lit; check there is full evacuation of smoke and fumes up the chimney. The heating system must be checked for leaks and balanced to ensure all radiators are heating up. On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer. Ensure to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the stove. Ensure that the customer is instructed on the use of the appliance as well as recommended fuels. Insist that the customer reads the instructions and fully understands the installations. Advise the user on the use of a fireguard which must be to BS 8423: 2002 standard and what measures to be taken if smoke or fumes are emitted from the stove. CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer s instructions. Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system. Operating Instructions Primary Air (Manual Control) Primary air (the air supply under the grate) is controlled via sliding vents in the bottom of the doors. This provides an air supply to the bed of the fire. The plus symbol (+) indicates more air, the minus symbol (-) indicates less air. The more air fed to the fire the hotter it will burn, however more fuel will be consumed. Chimney performance, atmospheric conditions and fuel quality will affect performance so practice will be required to get ideal setting of air conditions. Secondary Air (Airwash) Secondary air is controlled by the sliding vent above the doors. The control knob is situated to the top right of the stove. The plus symbol (+) indicates more air, the minus symbol (-) indicates less air. This airwash system ensures the glass is kept clean and feeds secondary combustion air to the fire to burn off un-burnt volatiles, reducing emissions into the chimney and the environment. Grate The grate is made up of fixed grate bars and sliding grate bars, these are operated by a long cam (Rocker bar). The rocker bar passes through a hole in the right hand side panel. The operating tool fits the flats on the end of the rocker bar.

Operating Instructions Door glass The glass used in the doors will resist very high temperatures, well above the output of this appliance. The glass panels will not break with heat. The airwash system will usually clear any soot or tar deposits on the glass panels, but if cleaning is required then use a recommended stove glass cleaning foam. Only clean glass when it is cold. Do not use any abrasives as this will scratch the glass making soot and tar build-up harder to remove. To replace the glass, remove the door by lifting off hinge pins, lay door flat and remove retaining clips. Lift out old glass and check glass seal. Replace if necessary. Fit new glass panel and retaining clips, tighten screws and place door back on to hinge posts. Door handle The door handle along with the mitten provided are operating tools. It is not advisable to leave the door handle connected to the door as high temperatures will be created in the handle and could cause harm if handled. Always remove the handle using the mitten provided. Alert other users to these instructions. De-Ashing It is important that the stove is de-ashed regularly. The airflow through the grate keeps it cool, adding longevity of grate life and minimising distortion. To operate: Offer the operating tool to the riddling bar (right hand side panel near base)and using slow positive movement riddle the grate back and forth. The reciprocating movement will clear the grate. The grate can jam occasionally with clinker or more often with nails and screws from used timber. Use shorter, faster movement of the tool to dislodge. If jamming persists then the obstruction must be removed when the stove is cold. If the grate is kept clear and maintained it will last longer. Notes on Wood Burning Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash from the grate occasionally. Burn only dry, well seasoned wood which should have been cut, split and stacked for at least 12 months with free air movement around the sides of the stack to enable it to dry out. Burning wet or unseasoned wood will create tar deposits in the stove and chimney and will not produce a satisfactory heat output. It is recommended that the moisture content of the wood be no more than 20% for ideal combustion. Notes on Solid Fuel Burning Always de-ash before refuelling and do not let the ash build up to the underside of the grate bars. Solid fuel produces ash, which if allowed to build up will stifle the air flow through the grate and eventually cause the fire to die. With some solid fuels a residue of burnt fuel or clinker will accumulate on the grate. Allow the fire to go out periodically to remove this. We cannot stress firmly enough how important it is to empty the ashpan regularly. Air passing through the fire bed cools the grate. Distortion or burning out the grate bars is nearly always caused by ash being allowed to build up the underside of the grate. Lighting The Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output. This is to allow the paint to cure and the castings to relax and consolidate location. We recommend a running in procedure after long shut downs to preserve the life of the stove. During this you may notice an unpleasant smell. It is not toxic, but for your comfort we suggest that during this period you leave all doors and windows open.

Operating Instructions Lighting The Stove...Continued First load the fire with starting fuel i.e. paper, dry kindling timber and/or fire lighters in the mode chosen, either wood or coal. Light the fire at the base leaving all air controls open. Allow the fuel to reach a steady glow and build the fire up gradually. Once you have a good fire established across the grate bed, further fuel can be added as required. When your fuel is well alight you can start to restrict the primary air intake. If you are burning only wood, the primary air control can be fully closed. If you are burning solid fuel you will require more primary air. Your stove is burning with maximum efficiency when a bright fire is achieved using minimum air inlet. The stove can be banked up for long periods. When burning solid fuels, de-ash the grate using the riddling mechanism and empty the ashpan. Open air controls and let the fire burn brightly for a short period. Refuel and close the air controls the exact setting required will depend on the fuel used and the chimney draw so some practice may be necessary. To revive the fire, open the air controls until the fire is burning brightly, de-ash if necessary (solid fuel only) and refuel. Set air controls as required. DO NOT OVERLOAD. If there is a possibility that a part of the heating system may be frozen you should not light the stove until you are confident that the system is free of ice, has no leaks and water is able to fully circulate. Solid Fuels We recommend the majority of approved manufactured smokeless fuels. Household coal, which is smokey fuel can also be used but note that different types will give different performances. Use as an incinerator is not recommended as fumes from plastics etc will cause pollution to the atmosphere and will damage the stove s internals. Recommended fuels: seasoned logs with less than 20% moisture content, solid fuel:- anthracite large nuts, briquette smokeless fuel i.e. Ancit, Phurnacite, Taybrite, homefire ovals suitable for closed appliances. PETROLEUM COKE FUELS OR HOUSEHOLD WASTE SHOULD NOT BE BURNT ON THIS APPLIANCE Should any difficulties arise over fuel quality or suitability, consult your local supplier or the Solid Fuel Advisory Service.

Safety Notes FIRES CAN BE DANGEROUS Always use a fire guard(to BS 8423:2002) in the presence of children, the elderly of the infirm. Inform all persons the dangers of high temperatures during operation of appliance including the stove pipe. Use operating tools provided. DO NOT OVER FIRE it is possible to fire the stove beyond its design capacity. This could damage the stove, so watch for signs of over firing - if any part of the stove starts to glow red, the fire is in an over fire situation and the controls should be adjusted accordingly. Never leave the stove unattended for long periods without adjusting the controls to a safe setting - careful air supply control should be exercised at all times. WARNING NOTE Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, then the following immediate action should be taken:- A) Open doors and windows to ventilate the room and then leave the premises. B) Let the fire go out. C) Check for flue or chimney blockage and clean if required. D) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek expert advice. The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be kept clean at all times. CO ALARM Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions under WARNING NOTE above. Do not use aerosols near the appliance when under fire General Maintenance Stove Body The stove is finished with a heat-resistant paint and this can be cleaned with a soft brush. Do not clean whilst the stove is hot, wait until it has cooled down. The finish can be renovated with a suitable brand of paint. Glass Panels Clean the glass panels when cool with a proprietary glass cleaner. Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult. Wet logs on heated glass, a badly aimed poker or heavy slamming of the doors could crack the glass panels. The glass will not fracture from heat.

General Maintenance Chimney Check your chimney each year before starting to use your stove for the winter. Birds may have nested in the chimney or the masonry may have cracked. Both chimney and flue pipe must be swept at least once a year. The chimney and any connecting flue-pipe should be swept and the appliance serviced regularly, cleaning the appliance flue-ways if incorporated. Regular sweeping means at least once a year for smokeless fuels and a minimum of twice a year for bituminous coal and wood. Ensure adequate access to cleaning doors where it is not possible to sweep the chimney through the appliance. Where the chimney is believed to have served an open fire installation it is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered, with the consequent risk of flue blockage. It is therefore recommended that the chimney be swept a second time within a month of regular use after installation. If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open. It is important that the flue connection, any appliance baffles or throat plates and the chimney are swept prior to lighting up after a prolonged shutdown period.

Trouble Shooting POOR HEAT OUTPUT A) Stove too small for a room. Seek advise from a Qualified Heating Engineer as to (KW) output required for room size as a guideline the volume of the room in cubic feet divided by 500 i.e. room 15 x15 x8 would require 3.6kw approx. B) Chimney and/or flue pipe restricted, room ventilation restricted. On installation these will have been checked but regular maintenance is necessary as conditions can change i.e. soot build up, birds nesting, masonry fall, dust build up or furniture blocking vents. C) Poor quality fuel. Only burn dry seasoned timber, soft woods have a lower heat output then hard woods per hour. Solid fuels vary in heat value check with your coal merchant as to suitability. DIRTY GLASS PANEL A) Generally caused by poor fuel quality, see (1c) B) Use secondary air slide (Airwash) for glass panel. C) Fire burning to low, open air vents on stove create hot fire this may burn glass clean. D) If glass requires cleaning use glass cleaner recommended by your supplier, only use glass cleaner or cold glass. DO NOT USE any abrasives or scrapers as these will scratch glass causing tar build up harder to remove. UNBURNT FUEL IN FIREBOX Insufficient air reaching fuel. Open primary air slide, this will supply combustion air to burn fuel fully (unless it has reached a point of return ). Check ash pan is full, empty if required, grate may be blocked de-ash with riddler. Check for jammed clinker or nails in grate when fires out and cold. CHIMNEY FIRE Identified by loud roaring sounds, dense smoke and sparks emitting from chimney. Shut down the air supply by closing the air vents, close the stove door fully and call the fire brigade immediately. Regular chimney maintenance will prevent chimney fires. Seek advice from a qualified chimney sweep SMOKE AND FUMES ENTERING ROOM These are very dangerous and must NOT be tolerated. Open window and allow fire to burn out, seek expert advice immediately. DO NOT USE stove until the problem is solved. A list of Qualified Engineers is available from UK Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire. DE557AS. Tel- 0845-601-4406. R.o.I.: Irish National Fireplace Organisation, 162 Chapel Street, Dublin, Tel-01-801-5959.

Installation Diagrams Typical Top Flue Installation using steel closure plate incorporating clean out door for chimney sweeping.

Installation Diagrams Typical Rear Flue Installation with clean out door.

Installation Diagrams Typical Installation For Inglenook Fireplaces Inglenook fireplaces can have very large bore chimneys. Check with your installer you may need stainless steel flexible liner for solid fuel fitting.

Installation Diagrams Typical Installation Into In Filled Masonry Fireplaces

Appliance Commissioning Checklist IMPORTANT Please complete and leave with the customer upon installation completion. Installer Name... Company Name... Address...... Telephone number... Date installed... Stove model/description... Serial number... Is the flue system correct for the appliance Yes No Flue swept for soundness test complete Yes No Smoke test completed on installed appliance Yes No Spillage test complete Yes No Use of appliance and operation of controls explained Yes No Instruction book handed to customer Yes No