User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

Similar documents
Operation Manual 322 KL

Friwa Compact. Operating instructions EN

Operating Manual. VIENNA Hot Display

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Preamplifier Power Supply PPS-02 user's guide

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Operating instructions (translation) Stunning Device for Small Animals

INSTRUCTION MANUAL HS-229G

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Product Manual Glue Applicators MS 80 and MS 200

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Translation of the original instructions. Type: MPR 150 / 220

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

USER MANUAL. Adventure Kings 50L Refrigerator

INSTALLATION, OPERATION AND MAINTENANCE

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

UFM-T100H US ES CA Power Alarm Test TM

Translation of the original instructions. Type: MGR 1500

V80-H Multistage Pump Instruction Manual

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Translation of the original instructions. Type: MKR 600

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Glass and Dishwashers AMX / AUX Series

TRAVELMATE. Instruction Manual

TTV 4500 / TTV 4500 HP / TTV 7000

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions.

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

ENGLISH USER S MANUAL PRE SOAKER 3600

TRAVELMATE FRIDGE FREEZER Instruction Manual

Moisture inside the drum is due to final testing.

Installation and instruction manual SOLAR STATION

PATIO CLEANER PPC 30 PATIO CLEANER. Translation of original operation manual

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

IH 025 VOLCANO. Portable Induction Heater. smart mounting

Read these instructions before using and keep them available at all times!

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

WHE 2.24 / WHE 2.24 FF

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

REFRIGERATED RECIRCULATORY COOLER

Bona DCS70/Portable DCS Manual and safety instruction

The Classeq under counter range

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

3 in 1 Garden Vacuum 9255 Instructions for Use

INSTALLATION INSTRUCTIONS. York Column Ensemble Part #: 1724 IMPORTANT

Original operating instructions Safety switch with guard locking AC901S AC902S

BarAid 400. Installation and. Starting from Serial No.:

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Installation & Operators Manual

KK70 Silent. Installation and Operating Instructions L V001

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

Millo / Millo pro. Nr x000 / 1805-x000

Popcorn Warmer Cabinet

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

HKF 8180 Operating instructions

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

KADO LUX LED EXHAUST FAN 200

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

Instructions for the fan motor control system, SILVER C

Industrial Vacuums, Inc

Glass and Dishwashers AMX / AUX Series

PJ130S High Pressure Cleaner

FHA 1100 A1 Domestic Water Pump

PoolSweepa Wallclima / Optima Pool Cleaners. Operating Instructions

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

INSTRUCTIONS FOR USE AND INSTALLATION HOT DOG MACHINES CS0 E / CS3 E / CS4 E / HD 4. Made in France G03312

EQUIPMENT MANUAL FOR ES25 PASS THROUGH DISHWASHER

Instruction Manual. Orayonne. Glass radiation heater

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

GLEB Kitchen exhaust fan

USER S MANUAL ATH WH220

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Instructions for installation and use English. More documents on: H B /09

Instructions for the fan motor control system with integrated wiring terminals SILVER C

HEAT RECOVERY AIR HANDLING UNIT

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

Operating Manual JuniorPower

VC-1, VC-1-SL, VC-2-L, VC-2-SL

STEAM WALLPAPER STRIPPER MODEL HTW5

TDS 20 R / TDS 30 R / TDS 50 R

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

EHA Hoffmann International GmbH

SASE BULL 240C. Dust Collection System Manual

Operating Instructions. Keep for future reference! Maschinenbau Werkzeuge Laborgeräte. Machine no.:... Hausanschrift:

Lifting Station Type ABS Sanimax

Operation Manual. For. Herbicide Sprayer

Transcription:

User Guide Topax Hygiene System S Booster MP44/MP66/MP88 Vers. 1.0 01.01.2012

Contents 1. Preface... 3 1.0 Application... 3 1.1 Warnings... 3 1.2 Safety Instructions... 4 2. Standard Unit... 5 3. Description of Function... 6 3.0 Flow Chart... 6 4. Installation... 7 4.0 General... 7 4.1 Mounting... 7 4.2 Pipe Work... 7 4.3 Priming... 8 4.4 Electric connection... 8 5. Function... 9 5.0 Operational Instructions... 9 5.1 Operation of Booster controller... 9 5.2 Systemsicherheit... Error! Bookmark not defined. 6. Technical Data... 10 7. Maintenance... 11 7.0 Instructions... 11 7.1 Trouble shooting and Remedy... 11 8. Components... 12 8.0 Exploded Drawing Booster MP Unit with Spare Spart List... 12 9. Warranty... 14 Subject to errata Vers. 1.0 01.01.2012

1. Preface The S Booster is designed for the boosting and transfer of clean water to cleaning equipment within the food industry. It is important that your operational staff reads these directions for use prior to the installation and start of operation. Operation as laid down in these directions for use will ensure an optimum level of hygiene in your factory and a minimum level of maintenance and repair work. 1.0 Application The S Booster is made of corrosion resistant materials, mainly stainless steel, and is therefore, especially suitable for application within the food industry. If you need information on further applications, please contact Ecolab. 1.1 Warnings The special warnings CAUTION, ATTENTION and NOTE used in this Technical Manual have the following meanings: CAUTION: ATTENTION: NOTE: This term is used to highlight the fact that complete or even partial failure to properly adhere to operating instructions, working instructions, specified working sequences and similar can cause personal injuries or accidents. This term is used to highlight the fact that complete or even partial failure to properly adhere to operating instructions, working instructions, specified working sequences and similar can cause damage to the equipment. This term is used to draw attention to a particular feature.

1.2 Safety Instructions A) Repairs are only to be carried out when the unit is switched off. Warning! WARNING The unit is only to be used for purposes as described in this user guide. WARNING Dry running for even a very short period of time can cause dry running not detected by our dry running security. In any case a stable and sufficient water supply is ALWAYS required.

2. Standard Unit The Booster consists of two pumps mounted on a floor frame, non-return valves, manifold (inlet) with flow switch, manifold (outlet) and Booster controller unit. 1. Inlet 6. Manifold 2. Manifold 7. Outlet 3. CRIE Pump 8. Ball valve 4. SF Pump 9. Non return valve 5. Pressure transmitter 10. Temperature sensor 11. MPC-E controller 119000068

3. Description of Function 3.0 Flow Chart 2. Pressure transmitter 6. Pressure transmitter 3. CRIE Pump 8. Ball valve 4. SF Pump 9. Non return valve 5. Pressure gauge

4. Installation 4.0 General The Booster unit must be installed and all electric connections must be performed in accordance with local regulations. 4.1 Mounting The Booster unit must be placed in a well ventilated room, in order to secure adequate air supply for cooling of the pump engines. This also applies when the motors are in operation. The clearance in front of and on either side of the pumps must be at least 75cm. 4.2 Pipe Work When installing the piping take care to avoid air traps. CAUTION Before the booster unit is connected to the water supply, the supply line should be rinsed through carefully in order to remove coarse impurities and metal shavings. The pipes are connected to the manifolds of the Booster set. Either end can be used. The set must be tightened up before start-up.

4.3 Priming Do not start the pumps until filled with water! 4.4 Electric connection Electrical connections must be carried out in accordance with local regulations and must only be carried out by authorised engineers. The motors are started directly on line (Star delta, optional). The motors are fitted with built in thermal switches. As additional protection, fault voltage relays, earthing or neutralising can be used instead. The wiring diagram is placed on the inside of the S Booster control unit. The diagrams state values required for the electricity supply. Check direction of rotation. NOTICE The correct direction of rotation is shown by arrows on the pump head and on the motor fan cover.

5. Function 5.0 Operational Instructions CAUTION Ensure that the spray gun or low pressure valve is closed before start The S Booster is bled by loosening the bleeding screw at the top of the pump stations. The screw must be left open for approx. 4 minutes allowing water to run out. All pipes are bled by opening the connections one after the other. It may be necessary to repeat this procedure. 5.1 Operation of Booster controller Please see MPC User guide!

6. Technical Data Data MP44 MP66 MP88 Supply voltage Siehe Typenschilder auf Motoren Siehe Typenschilder auf Motoren Siehe Typenschilder auf Motoren Isolation class IP54 IP54 IP54 Max. Leistungsverbrauch 60 kw 90 kw 120 kw Control voltage 24 VAC 24 VAC 24 VAC Capacity 0-44m 3 /h 0-66m 3 /h 0-88m 3 /h Water inlet pressure 2-4 bar 2-4 bar 2-4 bar Water inlet volume Min. 44 m 3 /h Min. 66 m 3 /h Min. 88 m 3 /h Water inlet temperature Max. 70 C Max. 70 C Max 70 C Temperature 5-40 C 5-40 C 5-40 C Capacity: The figures show the max m 3 /h (l/min) the pumps can deliver at an inlet pressure of 2 bar and following end pressures 30 bar: 35 bar: 40 bar 44,8 (753) 39,6 (660) 33,0 (550) 67,2 (1130) 59,4 (990) 49,5 (825) 89,6 (1506) 79,2 (1320) 66,0 (1100) Approvals: CE CE CE Weight: 1400 kg 1750 kg 2800 kg Dimensions (H x B x T): 2000 x 1500 x 1800 mm 2000 x 1500 x 2500 mm 2000 x 1500 x 3200 mm

7. Maintenance 7.0 Instructions Depending on usage, maintenance should be undertaken by an authorised service engineer at least once a year in order to prevent defects and failure of operation. Authorised engineers are persons who, due to their skills and experience, have sufficient knowledge of low pressure cleaning systems or similar and are confident with the state work safety regulations, accident preventive regulations, guidelines and generally acknowledged technical regulations such as DIN-norms and VDE-provisions. For your safety, this cleaning system has been manufactured according to all relevant regulations valid within the EU and it has, therefore, been supplied with the CE-mark. For further information, please contact the service department of Ecolab.. 7.1 Trouble shooting and Remedy Please see user guide for MPC.

8. Components 8.0 Exploded Drawing Booster MP Unit with Spare Spart List 119000068

Pos. no. Article no. Description Number 1 Inlet 1 2 313800 Pressure transmitter 1 3 0604221 CRIE 15-17 Pump 2 (3) (4) 4 852900 CRN 15-16SF Pump 2 (3) (4) 5 659000 Manometer 0-60 Bar 1 6 313800 Pressure transmitter 1 7 Outlet 1 8 334604 Ball valve 4 (6) (8) 9 359944 Non return valve 2 (3) (4) 10 0601444 Temperature sensor 4 (6) (8) 11 110001327 Controller 1

9. Warranty Attention! Our guarantee is given for a period of 12 months from delivery on all parts which have provable become unfit for use due to material, construction or manufacturing defects as well as inadequate work. The guarantee compensation will occur in the shape of either reimbursement, replacement or repair of the defective or damaged part at our works. Installation and freight costs are always on the purchaser s account. Any defective parts are to be placed at our disposal. Claims that may otherwise be raised for any legal reason will not be acknowledged. No liability will be accepted for damage occurred indirectly. The purchaser has no right to let any third party repair possible defects on our account. All hoses, rubber parts or synthetic materials, natural wear and tear as well as damage caused by careless and inappropriate handling, including transport damage are not covered by the guarantee. Further, the guarantee does not apply if the system has been subjected to frost. The obligation of guarantee compensation also ceases if changes or repairs are made by non-authorised persons. Claims under the guarantee will only be acknowledged when they are placed immediately after the defect has been noticed. The guarantee ceases in case of change of ownership. The dealer cannot be held responsible for personal injury, damage to equipment, working deficits, including production loss, loss of profits, loss of stock or the like which may occur by imperfect and delayed delivery of the sold product, regardless of the reason. Further, see our standard terms of sale and delivery.

CE Declaration of Conformity Nilfisk-ALTO Food Division declares that the machine: No.: 119000149 Name: Type: Booster MP44 Booster, MP - is manufactured in conformity with the following standards: Directive 2006/42/CE of the European Parliament and of the Council of 22 June 1998 on the approximation of the laws of the Member States relating to machinery. EN 60335-2-79 EN 60335-2-34 Household and similar electrical appliances Safety Particular requirements for high pressure cleaners and steam cleaners Household and similar electrical appliances Safety Particular requirements for motor-compressors Council Directive 2004/108/CE of 3 May 1989 on the approximation of the laws of the Member States relating to Electromagnetic Compatibility. EN 55014-1 EN 55014-2 EN 61000-2-3 EN 61000-3-3 Aalborg d. 30.11.2010 Signature: Michael Mortensen Manager OEM and Special

CE Declaration of Conformity Nilfisk-ALTO Food Division declares that the machine: No.: 119000068 Name: Type: Booster MP66 Booster, MP - is manufactured in conformity with the following standards: Directive 2006/42/CE of the European Parliament and of the Council of 22 June 1998 on the approximation of the laws of the Member States relating to machinery. EN 60335-2-79 EN 60335-2-34 Household and similar electrical appliances Safety Particular requirements for high pressure cleaners and steam cleaners Household and similar electrical appliances Safety Particular requirements for motor-compressors Council Directive 2004/108/CE of 3 May 1989 on the approximation of the laws of the Member States relating to Electromagnetic Compatibility. EN 55014-1 EN 55014-2 EN 61000-2-3 EN 61000-3-3 Aalborg d. 30.11.2010 Signature: Michael Mortensen Manager OEM and Special

CE Declaration of Conformity Nilfisk-ALTO Food Division declares that the machine: No.: 119000149 Name: Type: Booster MP88 Booster, MP - is manufactured in conformity with the following standards: Directive 2006/42/CE of the European Parliament and of the Council of 22 June 1998 on the approximation of the laws of the Member States relating to machinery. EN 60335-2-79 EN 60335-2-34 Household and similar electrical appliances Safety Particular requirements for high pressure cleaners and steam cleaners Household and similar electrical appliances Safety Particular requirements for motor-compressors Council Directive 2004/108/CE of 3 May 1989 on the approximation of the laws of the Member States relating to Electromagnetic Compatibility. EN 55014-1 EN 55014-2 EN 61000-2-3 EN 61000-3-3 Aalborg d. 30.11.2010 Signature: Michael Mortensen Manager OEM and Special