Technical

Similar documents
Technical

Technical

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

Technical


Technical

New Power Vented Rheem FVIR Tanks

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Guardian PowerVent Training Manual. Flammable Vapor Ignition resistant (FVIR) compliant PowerVent water heater manufactured after 1 January 2006

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

COMMERCIAL GAS WATER HEATERS

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

Operator: Save these instructions for future use!

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Operator: Save these instructions for future use!

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

Figure 10 or Figure 6

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

50A Integrated Furnace Control

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

A.O. Smith Water Products Company

Interrupted Ignition Series Oil Primary Control

Operator: Save these instructions for future use!

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50A Integrated Furnace Control

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Operator: Save these instructions for future use!

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

7800 SERIES Relay Modules

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Service Manual Model 3163

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Eclipse Self-Check UV Scanner

Bosch 80% AFUE Gas Furnace BGS80 Model

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

XIII Troubleshooting

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

Hot Surface Ignition (HSI) System Booklet

CONVERSION MANUAL CAUTION

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Operator: Save these instructions for future use!

SERVICE MANUAL. Ultra High Efficiency Models with Direct Spark Ignition. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Technical by adjusting

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

EG & PEG Series 5 EGH Series 5

AWEIS Troubleshooting Guide Table of Contents

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

SERVICE MANUAL. PDV Series. Power Direct Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

SERVICE MANUAL. Residential D Series. Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

Control manual and troubleshooting guide

Condensing Models. On-Demand Water Heater Service Handbook

Electronic Ignition Water Heater

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

CLOTHES DRYER Technical Information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

IMPORTANT SAFETY INFORMATION

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

CLOTHES DRYER Technical Information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

SERVICE MANUAL. Ultra Low NOx Atmospheric Vent Water Heaters with Direct Spark Ignition. Troubleshooting Guide and Instructions for Service

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Q - Series Boiler. Troubleshooting Manual

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

SERVICE MANUAL. PV Series. Power Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

SERVICE MANUAL. TTW Series Through-The-Wall Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

MG & SG SERIES BOILERS

Packaged Gas/Electric

Eclipse 90 UV Scanner Model A Version 1

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Fire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions

ELSTON. H-LC Nosemount Cargo Heater. Owner s Manual for H-LC Cargo Heaters. Please Contact Us for Parts and Service: Another Quality Product of:

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

21 TRV Blower Installation Instructions

Each heater has slightly different operational characteristics

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

Transcription:

Power Direct Vent No Power or No Blower Motor Nothing happens at all. No blower motor; no sounds. y There iss not a display code for this problem. 1. Check wall plug power with a table lamp. 2. Check that the unit is plugged in. 3. Verify blower motor switch is ON. 4. Verify power to the control thru the red#2 wire on the blower motor Molex. You should be able to wake up the control by holding down the red and blue arrow keys at the same time. Adjust water temp to 1200 0 F. 5. Verify power to the blower at the yellow wire on the blower motor Molex. Replace blower if there is power on the yellow wire, but noo blower motor. Replace control if no power on yellow wire. Error 1 An open earth ground circuit to the water heater. y 1. Check that the earth ground conductor is properly connected at the fuse box or breaker panel and the water heater. 2. Check that the grounding conductors on the water heater are properly connected and secure. 3. Check green grounding wire connection on side of control valve. Error 2 The self diagnostic test detected a wiring error or a high resistance to earth ground. y 1. Check for proper connection of the line neutral and line hott wires. 2. Check that the appliance is securely connected to earth ground. Error 3 y The exhaust pressure switch (normally open) remained closed longer than 5 seconds after the call for heat began. This error code will appear within 5 seconds if the pressure switch will not open. 1. The pressure switch has been jumpered. 2. The pressure switch is defective (contacts inside switch permanently closed) and must be replaced. 3. Replace blower assembly. Error 4 Competence, Productt Confidence Page 1 of 7

Power Direct Vent y 1. One of the two pressure switches remained open longer than 5 seconds after the combustion blower energized. 2. Blower thermal switch is tripped. 1. The pressure switch tube(s) is not connected correctly or pinched off. 2. The vent over-temperature switch is activated or defective. Check for heat at the top of the blower. 3. Obstructions or restrictions in the water heater venting. Remove venting and recycle to rule out venting. If unit goes to main burner, the venting is the problem. If the code repeats without the venting connected, replace the blower assembly. Error 5 The self diagnostic test has detected an error in the Hot Surface Ignitor circuit. y 1. Check that the wiring harness Molex is connected and secure. 2. Disconnect the ignitor connector and measure the ignitor resistance with an ohmmeter between pins 1 and 2. Resistance should be between 11.5 and 18.8 ohms. the reading is incorrect, replace the Hot Surface Ignitor assembly. 4. If the above checks are good, replace the Intelli-Vent TM control. Error 6 y The maximum number of ignition retries or recycles has been reached and the system is in lockout. (This means there was no flame rectification to the control to verify main burner.) 1. Check if the gas supply is off or too low to operate. 2. Check the flame sense rod to see that it is located properly and free from contamination. Reposition the flame sense rod or lightly clean with an abrasive cloth. (Seee last page for positioning of flame rod.) 3. The Hot Surface Ignitor may not be positioned on the burner correctly. Reposition as necessary. (See last page for proper positioning of hot surface igniter and flamee probe) 4. Low voltage to the water heater. (Verify the hot surface ignitor glows byy recycling power and looking thru sight glass window. If you have a glowing ignitor, then your problem is probably fuel related.) 5. Inadequate fresh air to support combustion inside combustion chamber. 6. Main burner supply tube is blocked, bent or restricted; burner orifice is blocked or restricted. Error 7 Competence, Productt Confidence Page 2 of 7

Power Direct Vent with the gas valve driver circuit. Error 8 with the internal micro computer Error 9 with the internal circuit Error 10 Competence, Productt Confidence Page 3 of 7

Power Direct Vent Flame signal sensed out of proper sequence. (The flame probe sensed the presence of flame when it was not supposed to.) Error 11 High temperature thermal cut-off (ECO) switch is tripped. (This one time use device trips when the water temperature exceeds 195 0 F.) Error 12 The self diagnostic test has indicated one of the temperature adjustment buttons is stuck closed. 1. Make sure that there are no objects leaning against the front of the control 2. Lightly press and release each of the buttons once. the above actions do not clear the error, the control will continue to regulate water temperature at the last setting, but you are not able to change settings unless you replace the Intelli-Vent TM control. Error 13 The self-diagnostic test has detected that the water temperature sensor is either open or short circuited. Error 14 Competence, Productt Confidence Page 4 of 7

Power Direct Vent with the Flammable Vapor Sensor. (This is not a flammable vapor event. It may be caused by disconnecting the FV sensor Molex, or the FV sensor itself. This includes both short and open electrical connections.) 1. Check all FV sensor wiring harness connections; and the connections to the back of the sensor. 2. Cycle power to the water heater off for 10 seconds and thenn back on. no wiring problems are found, the Flammable Vapor Sensor must be checked. a. Disconnect the FV sensor Molex and measure the resistance of the sensor between the two black wires 2 and the resistance is less than 9k OHMS or greater than 45k OHMS, then replace the sensor. b. If the FV sensor is between 9K OHMS and 45K OHMS and the code will not clear by recycling power, replace the Intelli-Vent TM control. Error 15 The control detected the presence of flammable vapors near the water heater and entered lock out. This is a permanent lockout and cannot be cleared by cycling power. Control may be reset. 1. Disconnect the FV sensor Molex and measure the resistance of the FV sensor between the two black wires 2 and 3. 2. Write down this resistance and call the technical support line at 800-432-8373 for further instructions. 3. The control is field resettable; however, we probably need to replace the FV sensor if the sensor is out of tolerance. Competence, Productt Confidence Page 5 of 7

Power Direct Vent Flickering Lights on Control y All light flicker in an erratic pattern. This condition is All lightt flicker in an erratic pattern. caused by an erratic or lost neutral connection. 1. Measure for 120V between the long and short slots on the wall plug. Check for loose wires inside the wall plug if needed. 2. Turn blower ON. Measure for 120V between the red and wire wires on the bottom of the control as indicated in this photo: you have 120V between the red and white wires, replacee the control. 4. If you do not have 120V, with the unit still ON, then checkk the wiring harness connector between the middle red and top white wire at the blower motor as show in the picture below. 5. IF you have 120V at the wall and not at the blower, then replace the blower motor. Competence, Productt Confidence Page 6 of 7

Power Direct Vent Flame Sensor Rod Position The table and diagrams below show the proper placement of the flame sensor rod for the Guardian PowerVent with the White Rodgers control. Flame Sensor Rod Positions (Nominal) Models "X" Natural Gas 1/2" Propane Gas 7/16" "Y" (+)1/32" (above burner lip) 0" (even with burnerr lip) X positioning (top view) Y positioning (side view distance from top of burner plate) Competence, Productt Confidence Page 7 of 7