USER S MANUAL HSC-14/18/24/24A

Similar documents
AIRREX DEHUMIDIFIER ADH-100 USER S MANUAL

Operating Instruction & Parts Manual Model : HSC-18PLUS/24PLUS

Portable Air Conditioner HSC-11

Sunleaves Air Conditioner

Split Portable Air Conditioner

CARBON INFRARED HEATER CH2500 TW

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

CARBON INFRARED HEATER CH1800 RE

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Instruction Manual. Portable Air Conditioner

PORTABLE AIR CONDITIONER

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Using the Remote Control Unit

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER MANUAL. 10,000 BTU to 60,000 BTU Capacities IS T E D ISO 9001, ISO 14001

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

5) Do not start or stop the unit by inserting or pulling out the power plug.

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

15,000 BTU Portable Air Conditioner

PORTABLE AIR CONDITIONER MODEL NO: AC9000

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Portable Heat Pump. Unpacking. Specifications. Owner s Manual. Owner s Manual 6HK16BEA2AAH0. Figure 1

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Inverter Split-type Room Air Conditioner

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

PORTABLE AIR CONDITIONER

FAR INFRARED RAYS HEATER

XS1271 XS1872 INSTRUCTION MANUAL MODE D EMPLOI This air conditioner uses the new refrigerant R410A.

MeacoCool MC Series Portable Air Conditioner

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

MeacoDry ABC Range Dehumidifiers

Local air conditioner

MODEL: DC10RCDH / DC12RCDH

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

USER MANUAL TPS-M5/M55/M555

XC Portable Air Conditioning

Portable Air Conditioner. Instruction Manual

Dehumidifier. Instruction Manual. Model DH-320/A

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

FAR INFRARED RAYS HEATER USER'S MANUAL MODEL : AH-300/600/700/800

EH0533 Indoor Climate Control

30-pint Dehumidifier User Guide

20L Electronic Dehumidifier

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

AC-12200E Portable Air Conditioner

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

53 KNL / 53 QNL OWNER S MANUAL

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

Dual-Hose Portable Air Conditioner User Manual

PORTABLE AIR CONDITIONER

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

IMPORTANT SAFETY INSTRUCTIONS

PC20-AMFII / PC40-AMF USER MANUAL

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Panel Heater Slim 1.5kw MODEL: NDK15-12K

SC-305/9H. SPLIT TYPE AIR CONDITIONER Instruction manual

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

air conditioner/dehumidifier 9000btu/hr

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Owner s Manual TABLE OF CONTENTS

Operating Instructions Air Conditioner

Owner's Manual TABLE OF CONTENTS

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

Portable Air Conditioner

Instruction Manual Item No.: V~, 60Hz

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

User Manual

ACCESSORIES INCLUDED

Ceiling Mount Air Purification System

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

User Manual. Commercial Refrigerator And Freezer User s Manual

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

General Care and Safety Guide

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

40KMC KMQ

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Transcription:

AIRREX AIR CONDITIONER USER S MANUAL HSC-14/18/24/24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL that you read the NOTES ON SAFETY carefully before use and follow them at all times. The Air Conditioners are specified for use on a 115V. 60Hz.1ph for models HSC-14/18/24, and 220V. 60Hz. 1ph for model HSC-24A single phase power supply. You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician. The Warranty form is on Page 15. Please complete it now and keep in a safe place. We have a policy of continual improving to our products. The contents (features and specifications) in this manual are therefore subject to change without notice.

TABLE OF CONTENTS SAFETY INSTRUCTIONS DESCRIPTION Front View Back View Control Panel OPERATING INSTRUCTIONS On/Off Operation Selection of Area/Room or Spot Cooling Economic Mode Temperature Control Off Timer Indicator and Operational Error Alerts CLEANING AND MAINTENANCE TROUBLE SHOOTING / ACCESSORIES SPECIFICATIONS WARRANTY 3 5 5 5 6 7 7 8 8 9 10 11 12 13 14 15 2

SAFETY INSTRUCTIONS The following instructions are for ensuring the user s safety and to prevent any physical injury or material damage. Please read carefully and follow all instructions. There are two sections to these instructions: WARNING and CAUTION. The following symbols are for your guidance: = You must NOT. = You MUST. WARNING Use a 115V. 60Hz.(HSC-14/18/24), 220V. 60Hz(HSC-24A) 1 Phase power supply only. (Wrong supply may cause a fire and / or shock hazard) Securely plug into an grounded outlet. (Unless earthed, may cause electric shock) Do not use a damaged power cable, plug or socket. (Short, fire or shock hazard) Do not remove plug by pulling cable or with wet hands. (Risk of fire and electric shock) Before cleaning, remove plug from socket. (Otherwise risk of electric shock) Do not place anything on top of the machine. (This could cause electric shock, malfunction or injury) Do not use an extension cord. (Risk of fire and / or electric shock) Ensure mains plug is clean and securely plugged in. (Otherwise it may short causing smoke and fire) Do not kink or sharply bend the power cable nor put any weight on it. (The insulation may be damaged causing fire and/ or electric shock) Do not turn off by removing power plug. Always turn off at control panel first. (Risk of electric shock and / or malfunction) Do not use this cooler on unstable or inclined surfaces. Always use on solid flat floor. (Risk of falling causing injury, fire or malfunction) A damaged power supply cable must be replaced with a new power supply cord obtained from the product manufacturer and not repaired. Keep this manual in a visible location near the cooler for easy reference. 3

SAFETY NOTICE CAUTION Do not place cooler on uneven, unstable or inclined surface. (This could cause malfunction) When storing the cooler, ensure that it is kept in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always unplug from power. (To prevent risk of electric shock, short circuit or fire) Do not spray water on to the cooler nor use solvents such as benzene, thinner or alcohol for cleaning. (There is a risk of electric shock and / or short circuit) Designed for indoor usage. GENERAL ADVICE BEFORE USE Ensure the safety of the location in which cooler is to be used. Ensure the floor or ground is smooth and sound. Ensure you allow at least 20inch air space all around the cooler. When in position LOCK the casters to prevent rolling. Never use the cooler at more than 2 incline. FOR MAXIMUM EFFICIENCY In airtight areas use vertical exhaust into ceiling. If possible locate exhaust outlet through a window or door to outside. Exhaust ducting should be no longer than 6.6 ft. for maximum efficiency. Ensure correct electricity supply. DUCT INSTALLATION The duct should be established before using. (Duct length : minimum 1ft) 4

EXTERIOR DESCRIPTION FRONT VIEW FLEXIBLE DUCT OUTLET (COLD AIR) HANDLE DIGITAL CONTROLLER ELECTRIC PANEL (ACCESS BY AUTHORISED SERVICE PERSONNEL ONLY) POWER PLUG CASTERS (FRONT LOCKABLE) BACK VIEW CONDENSER OUTLET (HOT AIR) EVAPORATOR FILTER AMBIENT AIR INTAKE. CONDENSER FILTER WATER LEVEL INDICATOR TO CHECK WATER LEVEL OF THE CONDENSATE TANK. CONDENSED WATER TANK TO COLLECT WATER GENERATED DURING COOLING. 5

CONTROL PANEL FUNCTIONS 13 3 7 8 9 4 5 10 11 12 6 2 1 1 Power : Use to power On / Off. 2 : Raises or lowers temperature and/ or sleep (off) time. 3 Cool : Use to select cooling mode. 4 Low Mode : Controls fan low speed. 5 High Mode : Controls fan high speed. 6 Off Timer : To set the length of time, once turned on, that you wish the cooler to run for. You can set 0~24 hours. Time intervals are 30mins. up to 10 hours and then 1 hour between 10 and 24 hours. 7 Remote : From the long distance, you can control the machine by wired remote control. 8 Room : If the LED is On, the displayed temperature is for Room temp. If the LED is Off, the displayed temperature is for spot temp. 9 Comp. : When the compressor is operating, the LED is On. 10 Error : Error signal ( E1 : High Pressure, E2 : Low Pressure, E3 : Sensor, AF: Eva Freezing) 11 Water Full: Red light indicates Tank Full. The compressor will shut off automatically. Empty tank and replace in position to resume operation. 12 Align Drain Tank : The red light indicates the water tank is not in the correct position. 13 Display : Display Room/Spot temperature, the setting temp and sleep time in case of setting them. When the user set the sleep timer, hr will be turned on. (Display of 'LO' : under the 32, Display of 'HI' : over the 99 ) 6

OPERATION RUNNING & STOP 1. START BY PRESSING THE POWER BUTTON. Cooler will start up automatically. To STOP the unit, press the POWER button once again. 2.To change fan speed, press the Low button. 3.If you wish to operate on fan only, press the COOL button. To resume cooling, press the COOL button again. (Note : There is a 3 minute delay when switching functions to protect the compressor) 7

SELECTION of AREA/ROOM or SPOT COOLING To reduce the temperature of the entire room select 'Area/Room'. For targeted cooling of machinery, servers, or people etc. select Spot Cooling. 1. If you want to display room temperature, push cool and button simultaneously during three seconds. 2. If you want to change temperature unit, push and button simultaneously during three seconds. ECONOMIC MODE If the compressor operation is stop in "Room Temp Mode", the Fan motor operation also is stop in 3min. later. In Room Temp Mode, If you want to go "Economic Mode", Push Low fan (or High fan) button continuously for 3 seconds. 1. or 2. If the Economic mode is effective, Room Mode LED is bilnk. 8

TEMPERATURE CONTROL OPERATION 1. When power is ON, the setting temperature is displayed. Default of setting temperature is as below. 50 in Spot Mode. 60 in Room Mode. 2. When you push either or button, the setting temperature is changed. 3. The display showing the set temperature will blink 3 times. 4. Display range & Setting range. Mode Display range Setting range Room Temp 32 ~99 60 ~86 Spot Temp 32 ~99 50 ~86 Cooling operates when Room/Spot temperature is more than set temperature. Cooling stops when Room/Spot temperature is less than set temperature. 9

HOW TO SET THE OFF TIMER. This function enables you to set the length of time you want the cooler to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. 1. When cooler is operating, press the Off Timer button and set the length of time you want by pressing or. Each time you press the button you will increase the time to off period by 30mins. up to 10 hours, and 1 hour thereafter up to 24 hours. The display will show.5 for 30min and 1 for an hour. e.g. One and a half hours will show 1.5. 2. When you have finished setting the time period, the Off Timer lamp will be on which indicates the cooler is in sleep (Off Timer) mode. OFF TIMER LAMP IS ON 3. If you press the Off Timer button during its operation, the remaining time will be shown. AFTER 1hr 4. To CANCEL timing, press Off Timer button for ONE second. It will then switch the timer off automatically. 10

'ERROR' and WARNING INDICATORS The machine s safety devices will automatically signal any problems via the display window on the control panel. The information below shows how to read these signals. 1. WATER FULL- Display shows FU When the water container is full, FU is displayed and the LED Water Full light will be on. 2. ALIGN WATER TANK If the water tank is not positioned correctly, the LED Align Drain Tank light will be on. 3. HIGH PRESSURE E1 is displayed and the Error LED will be on when the pressure of the compressor is too high and the high pressure switch is open. 4. LOW PRESSURE E2 is displayed and the Error LED will be on when the pressure of the compressor is too low. 5. SENSOR PROBLEM If the thermistor is short circuited or cut, E3 is displayed and the Error LED will be on. 6. ANTI FREEZING When the temperature of the evaporator is below 28, AF is displayed and the Error LED will be on. 11

CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS 1. To remove filters, slide up a little 1 and pull towards you 2. 2. Clean the filters with water or compressed air. 3. Clean evaporator and condenser units with a vacuum cleaner or compressed air. MAINTENANCE 1. After cleaning, completely dry the inside of the unit by operating on Fan Mode only for 3 to 4 hours. 2. Turn OFF at control panel, remove plug from socket. Coil and store cable neatly. 3. Keep machine suitably covered to prevent damage by damp, humidity and dust. 12

TROBULE SHOOTING TROUBLE NOT WORKING CHECKREMEDY Power plug correctly connected POWER button OFF Blown fuse in electric panel Fuse (supply) blown Breaker on switch board tripped Connect plug correctly Press POWER button to ON Replace fuse Exchange fuse in board Check load capacity and reset Ambient temp. too high Use only below 105 (over 105 ) POOR COOLING Filter blocked with dust Dust in heat exchanger Obstacle against inlet side Clean Filter Clean heat exchanger Remove and allow 50cm.clearance Ambient temp. too high Use only below 105 (over 105 ) ACCESSORIES ITEM MODEL HSC-14/18/24/24A DRAWING DUCT Diam. 5inch 12inch 9.8 ft. OPTION COLD AIR OUTLET DUCT COVER (FINISHING COLLAR) DAMPER BASE (FLOW CONTROL FLAP) ALUMINIUM FILTER CASSETTE HOT AIR EXHAUST ALUMINIUM FILTER CASSETTE 13

SPECIFICATIONS Cooling Capacity BTU/h kw HSC-14 HSC-18 HSC-24 HSC-24A 13,600 (3.98) 16,800 (4.92) 23,500 (6.89) 23,500 (6.89) Power Supply 115Va.c. 60Hz. 1Ph. 220Va.c. 60Hz. 1Ph. Dimensions (WxDxH) inch. 19.3 X 23.6 X 46.8 19.3 X 23.6 X 49.8 19.3 X 23.6 X 51.3 Weight lb 176 185 210 210 Evaporator Air Flow ft 3 /m 440 460 460 460 Power Consumption kw 1.5 1.95 2.25 2.6 Current Consumption Amp. 13 17 19.5 12 Nema Plug 5-15 5-20 5-20 6-20 Refrigerant lb R410A, 1.33 R410A, 1.76 R22, 1.76 R22, 2.97 Air Filter Safety Devices Power Cable DEVICE Aluminium Mesh Cartridge High Pressure Switch Fan motor protection Low Pressure Switch Tank position indicator. Auto Full Tank shut off. 3 min. delay timer. Thermostat and relief valve for compressor Plug Length 9.8 ft. Operating Range 72 DB 60% RH ~ 105 DB 40% High Pressure kgf/cm 2 /psig 31/455.7 26/370 Low Pressure kgf/cm 2 /psig 13/191.1 13/185 Max. Duct Length (Either hot or cold, not both together in use) Fuse in power box in Machine body Cold Duct Hot Duct 30 ft. 32.8 ft. 250Va.c. 10amp. 250Va.c. 5amp. 14

WARRANTY (Applicable to first retail purchaser only) AIRREX AIR CONDITIONERS give more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing. In the unlikely event you have any problems, please contact your dealer or distributor. If the problem is as a result of a production fault or failure, repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions: 1. The warranty period is 12 months from the date of first purchase. 2. If the problem has been caused by customer error or misuse, abuse or damage, then all repairs will be charged for. 3. This warranty applies to your country. 4. Proof and date of purchase must be supplied. 5. Please complete the details below and keep this warranty in a safe place. 6. All transport charges back to the dealer are at the customers cost. Keep all original packaging to facilitate return. Return to customer will be at dealers cost (if genuine warranty claim). DESCRIPTION MODEL DATE OF PURCHASE AIRREX AIR CONDITIONER HSC-14/18/24/24A PRODUCT SERIAL NO: Warranty Period ( ) Months DISTRIBUTOR Name of Company Telephone No. CUSTOMER DETAILS Name : Address : Telephone : 15

USA DISTRIBUTOR AIRREX USA P.O BOX 340 HEWITT, TEXAS 76643 TEL : 1-800-699-8998 FAX : 1-469-574-7924 sales@airrexusa.com HEPHZIBAH CO.,LTD. 423-5 CHUNGCHUN-DONG, BUPYUNG-KU INCHEON, KOREA TEL : +82-32-509-5834 FAX : +82-32-502-5519 E-mail : airrex@hdtek.com Website : www.airrex.co.kr Designs and specifications of products are subject to change without prior notice for the improvement of products.