FIRE DRILL WEEKDAY (MONDAY TO FRIDAY) DAYTIME ( )

Similar documents
Fire Evacuation Procedure St James Junior School and St James Senior Girls School

FIRE EMERGENCY PLAN AND FIRE RISK (PREVENTATION) POLICY

NEWBATTLE ABBEY COLLEGE. Fire Safety and Emergency Evacuation Policy and Procedure

EVACUATION POLICY 1. General

WARWICK PREPARATORY SCHOOL

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

THE HABERDASHERS ASKE S BOYS SCHOOL FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY

EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018

GENERAL - Regulatory. Fire Policy, Risk Assessment and Prevention (ISI 12a) Fire Procedures (ISI 12b)

Sir Christopher Hatton Academy A Member of Hatton Academies Trust

FIRE SAFETY, PROCEDURES AND RISK ASSESSMENT POLICY PART 1: FIRE SAFETY

Simon Woodfield Facilities Manager Governor Committee Policy Status Developed September 2009 Updated February 2017 Governor Approved June 2016

Emergency Evacuation Policy and Procedure

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

Fire and Emergency Plan: Evacuation & Invacuation. Fire and Emergency Plan: Evacuation & Invacuation

Fire Safety and Emergency Evacuation. Herne Bay Junior School. Compassion Courage Hope Integrity Justice Respect Responsibility - Wisdom

Fire Prevention and Procedures Policy

Fire Evacuation Procedure

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy.

FIRE SAFETY MANAGEMENT POLICY AND EMERGENCY RESPONSE POLICY (BCAD-HS-10-V1)

Fire Safety, Fire Procedures and Fire Risk Assessment Policy. Three Schools Policy

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

Fire and Bomb. Evacuation Policy

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

Report For NHS Shetland

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS

Fire Evacuation Procedures and Responsibilities Policy

Fire and Emergency Evacuation Procedures

University of London

CAPE BYRON RUDOLF STEINER SCHOOL

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

Fire and Emergency Evacuation Procedure

Fire Safety Policy LENT 2018

Arbour House. Fire Policy and Procedures

The Greens The Entrance

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

KELSO HIGH SCHOOL EMERGENCY EVACUATION PROCEDURE

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

AL NOORI MUSLIM SCHOOL. Emergency Evacuation and Lockdown Policy Policies & Documents

Fire Drill Policy. Facilities Manager DCD. Statutory. Principal. Staff. REVIEW DATE 20 th August Owner. Version Number: 8 Legal Sign:

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

SECTION SEVEN FIRE SAFETY PROCEDURES

SCHOOL POLICY. Fire Safety & Emergency Evacuation Policy & Strategy. UNCRC: Articles 3, 24, and 29. Reviewed by: Signed (Governing Board):

Fire Evacuation Policy

INDUCTION PACK. for Supply Workers, Contractors, Consultants and Volunteers. at Woodcroft Primary School. Keeping Children Safe In Education

EF ACADEMY - TORBAY. Evacuation Procedures

Emergency Procedures Policy

Fire Evacuation Procedure

Fire safety policy (Including Fire Emergency Plan)

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

GHS 8-4 Fire Policy and Procedures

EMERGENCY EVACUATION PLAN for FIRE

b. Fire Alarm System operating notes

EVACUATION PROCEDURES IN EDUCATION PREMISES

Fire Emergency Procedure

Summer Centre (Worcester Road): Social Programme Assistant, Stephen Taylor, ADOS

FIRE SAFETY POLICY AND PROCEDURE. Date: November 2018

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

Peninsula Dental Social Enterprise (PDSE)

Fire Safety Procedures & Risk Assessment Policy

EMERGENCY ACTION PLAN (General Evacuation)

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Elutec Fire and Evacuation Procedure

PERSONAL EMERGENCY EVACUATION PLANS (PEEP s)

Introduction Each adult working at the School will familiarise themselves with a copy of the detailed fire and evacuation procedure for the school.

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Fire Safety and Prevention Policy

FIRE & FIRE PREVENTION POLICY AND PROCEDURE

St Edward s Oxford FIRE SAFETY POLICY

On no account should anyone return to a burning building.

OLD HALL - RISK ASSESSMENT FORM. Date(s) Tuesday 2 Wednesday 3 July. External Contact & Nos. Sarah Taylor - Venue Information

Whitley Abbey Primary School

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

ST BEDE S CATHOLIC PRIMARY SCHOOL & NURSERY MANAGED FIRE PLAN

Fire Safety Policy and Procedures

Evacuation and Lockdown Plan

Fire Safety, Procedures and Risk Assessment Policy

Asmall Primary School

EMERGENCY MANAGEMENT PLAN For Lambton High School. Date of last review: April, Review date: April, 2018

FIRE POLICY This Policy includes the Nursery and Early Years Foundation Stage

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

CARDIFF HIGH SCHOOL EMERGENCY EVACUATION PROCEDURES

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES

Fire Evacuation Procedure WISE Campus

Waverley School. Fire Procedure. The original policy June 2014 Amended June 2017

CARDIFF HIGH SCHOOL EMERGENCY EVACUATION PROCEDURES

Fire Safety Policy (A11)

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

Fire Evacuation Procedure WISE Campus

EMERGENCY LOCK DOWN PROCEDURES

Alpha: Cindy Avitia High School School Safety Plan (Updated August 13, 2018)

Excel English. Health & Safety Policy

Whole School Fire Risk Prevention and Emergency Evacuation Procedures

Reviewed and Agreed by the Health and Safety Committee October Health and Safety: Fire Safety Plan and Procedures

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

FIRE SAFETY POLICY. Health and Safety. Reviewed by: Health & Safety Committee (2 May 2018) Approved by: Council (25 June 2018)

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Transcription:

FIRE DRILL WEEKDAY (MONDAY TO FRIDAY) DAYTIME (0900-1700) Date of Policy August 2018 Approved by Principal Yes Review Date August 2019 Key Staff All Teaching Staff, HsoD, VP Reviewed by VP, Ops Manager

Contents General briefing points... 3 Incident Box... 4 Instructions for Reception... 4 Instructions for Teaching Staff... 4 Instructions for Non-Teaching Staff... 5 Instructions for the Principal, Vice Principal and Duty Residential Staff.... 5 The Night-time Fire Drill and Academic Staff... 5 2

General Briefing Points All staff and students are to be briefed that the Fire Assembly Area (FAA) is immediately in front of the embankment running parallel to the High Street, Chesterton. The FAA is split into five zones; A, B, C, D, & E. The zones are marked with signs. A sketch of the FAA is provided below: SKETCH OF ELIZABETH HOUSE FIRE ASSEMBLY POINT All students are to be briefed that on hearing the fire alarm between 0900 and 1700, Monday to Friday, that they should go to the zone within the FAA designated for their Programme of Study (PoS) and form up in their tutor groups. Upper Sixth (A Level Year 1 and UFP): Zones A Lower Sixth (A Level Year 1): Zone B KS4 Programmes (Pre-Programme, GCSE, & AEM): Zone C (It is important that the students understand that they also go to the FAA outside daytime hours, but that they will go to the zone designated by the boarding staff; the Night Fire Drill). Teaching staff are to be briefed as follows: Programme Directors (PDs) are to move straight to the incident control point (ICP). At the ICP the PDs collect the registers for their PT groups. The PDs are then to move to the front centre of their designated zones, the position of the sign represents the centre of their zone, and they should hand out the registers to their PTs. 3

Personal Tutors (PTs) are to move directly to the zone designated to their PoS and take control of their PT group. (During induction the PD is to ensure that each PT knows where to position their PT group with the PoS s zone, this position must also be shown to the students during the Induction process). Members of the teaching staff who are not PTs are to move to Zone D. Non-teaching staff (Boarding and Welfare staff and Operations staff) and visitors are to be briefed to move directly to Zone E Duty nursing staff and any students who were in sick Bay are to go to Zone E. Incident Box An incident box is to be kept at reception. The incident box is to contain the following: Individual registers for each PoS with each PT group in alphabetical order. The registers are on individual clipboards. A full list of teaching staff. A full listing of boarding, administrative and catering staff. Box of pencils; c40, sharpened. Head torches x 6. 8 High- visibility vests. Instructions for Reception All new arrivals to the College, visitors and parents must be told where the Fire Assembly Area is located. On the fire alarm sounding the receptionist is to gather together the following items and place them in the incident box: The live registers in reception; The visitors book; The student permission slips. The receptionist will then take the incident box to the incident control point (ICP). The receptionist is then to remain at the ICP until they are told to do otherwise by the incident commander (IC). Instructions for Teaching Staff On hearing the alarm all staff and students are to evacuate the building and move to their designated zones within the fire assembly area (FAA). Those staff that are teaching at the time of the alarm should ensure that their room is cleared in an orderly fashion and they should be the last person to leave that room. On their way to the FAA the PDs should collect their registers from the receptionist at the ICP. If the PD is absent then a PT from the absent PD s team should collect the registers from the ICP and distribute them to the rest of the PTs. 4

PTs should move to the zone designated to their PoS, on arrival they should take control of their tutor group and then take a register. Completed registers are to be returned to the PD. Teaching staff who are not PTs are to remain in Zone D until directed to do otherwise by the Incident Commander (IC, Principal or Vice Principal). Instructions for Non-Teaching Staff Non-teaching staff and visitors are to remain in Zone E until directed to do otherwise by the IC. Individual line managers should take control of their teams in Zone E. Reception and Student Services should take control of any visitors in Zone E. Medical Centre staff should escort any students in their care to the FAA, where appropriate they should then send the students to the relevant PD. If any student needs continuing medical supervision they should remain with the nurse in Zone E. The nurse should then inform the IC of the pupils whom they kept with them in Zone E. Instructions for the Principal, Vice Principal and Duty Residential Staff. The Principal or Vice-Principal will usually act as the Incident Commander. In the absence of the Principal and Vice-Principal one of the Programme Directors is to act as the Incident Commander. On hearing the alarm sounding the Incident Commander is to move directly to the ICP and put on an orange high-visibility vest and then direct activity and allocate tasks as appropriate to the situation at hand. This may include moving all staff and students to the secondary FAA (the Residential Home Car Park) if the primary FAA loses viability. Depending on the time of day, either the Assistant Boarding Manager or the Day Supervisor is to check the fire panel, if appropriate and practicable they are then to check the location that has tripped the alarm confirming whether or not it is a false alarm. They should then move to the ICP and advise the IC of their findings. The IC will then either call the fire brigade or authorise the fire alarm to be turned off. On arrival at the ICP the IC will nominate a number of deputies from the available staff to assist in the administration of the fire drill In the event of a false alarm the full fire drill should be completed. However, the IC may curtail the drill at any point at his own discretion. The Night-time Fire Drill and Academic Staff If teachers or other members of the academic staff are in the building outside the hours of the day time fire drill and the fire alarm sounds, they should: Clear the room in which they are working. 5

Then move to Zone E in the FAA and await further instructions from the Boarding and Welfare Staff. 6