BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

Similar documents
2012 B.C. Building Code Compliance Review (Division B Part 3)

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

BC Building Code Checklist Part 3 Planning and Development Department

CHAPTER 7 ALTERATIONS LEVEL

BCBC 2012 CHANGES TO PART 3

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Life Safety - Means of Egress/Exits NFPA 101

Fire Protection Coffee Break Training May 2016

WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

COURSE SYLLABUS HVAC AND MECHANICAL CONSIDERATIONS FOR PART 3 BUILDINGS CORRESPONDENCE COURSE

FIRE SAFETY INSPECTION REPORT

150 Elgin - Office Tower and Grant House Renovations

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

PLAN REVIEW SUBMITTAL GUIDE

FIRE SAFETY INSPECTION REPORT

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Agency for Health Care Administration

January 1, 2014 Mandatory Effective Date

FIRE SAFETY INSPECTION REPORT

Module 9: Ontario Building Code Fire Fighting Provisions

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Chapter Nursing Homes

Short Term Accommodations Fire Code Requirements

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

FIRE SAFETY INSPECTION REPORT

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

Residential Care Facilities Requirements

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

For the Florida Building Commission And the Fire Code Advisory Council

2018 NICET Code Transition Changes

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

DEALING WITH FIRE SAFETY

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

INITIAL FIRE SAFETY ASSESSMENT

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

FIRE SAFETY INSPECTION REPORT

INITIAL FIRE SAFETY ASSESSMENT

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

FIRE SAFETY INSPECTION REPORT

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

At the Montréal city council meeting of April 10, 1995, it was enacted that:

GENERAL AREAS OF INSPECTION

HIGH-RISE RETROFIT ORDINANCES - NO and NO

ALABAMA. Downloaded

Date: February 22, 2005 Kimbalton DUSEL, Pre-S-2 Submittal CNA0402 PRELIMINARY CODE REVIEW. International Plumbing Code Edition

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing

Residential-based Care Facility R-4 Guideline

Rental Housing Inspection Guide

Agency for Health Care Administration

Residential Based Care Facility Guidelines

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

FIRE SAFETY INSPECTION REPORT

For additional information regarding R-3.1 residential care facilities please contact (951)

1. The provisions of paragraph (D)(1104) of this rule shall apply to all existing buildings.

INITIAL FIRE SAFETY ASSESSMENT

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

INITIAL FIRE SAFETY ASSESSMENT

Business License Pre-inspection Checklist

INITIAL FIRE ASSESSMENT REPORT (FAR)

WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Osceola County Department of Fire Rescue and Emergency Medical Services

INITIAL FIRE SAFETY ASSESSMENT

CFAA Technical Seminar Ontario Building Code Updates to 2015

The Residences at Christina Landing Wilmington, DE

The course only requires the latest edition of the following documents: Building Code Compendium, Volume 1 and 2.

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Nirmal Chandra Sinha. Supposed to complete(dd/ MM/YYYY) Comments after Physical Inspection

Agency for Health Care Administration

MULTI-LEVEL & COVERED BOOTH CONDITIONS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Transcription:

Exam ID Examination Code Part BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015 BC3-7 Level III Exam 7 BCBC Part 3 (Part 3 Buildings Classification & Construction) BC3-8 Level III Exam 8 BCBC Part 3 (Part 3 Buildings Plan Review) BC3-9 Level III Exam 9 BCBC Part 3 (Part 3 Buildings Life Safety Systems) BC3-10 Level III Exam 10 BCBC Part 3 (Part 3 Buildings Fire Protection) LEVEL III, EXAM 7 2 Hours - 50 01 General Requirements 0101 Code Application and Definitions 2 0102 Plans, Specification, Materials, Documents 2 0103 Professional Design and Review 1 0104 Design Requirements 2 02 Classification / Construction Requirements 0201 Major Occupancy Identification 4 0202 Occupant Load 2 0203 Types of Construction 1 0204 Building Height, Size 2 0205 Major Occupancy Separation 2 0206 Spatial Separation 6 0207 Exceptions to Structural Fire Protection 2 03 Passive Fire Protection 0301 Fire Separations and Closures 5 0302 Fire Stops 1 0303 Flame Spread Rating, Smoke Development 2 0304 Firewalls 3 0305 Fire Resistance Ratings 5 04 Vertical Transportation 0401 Standards 1 0402 Fire Separations 1 0403 Elevators 1 05 Access 0501 Access to Storeys 2 0502 Access Routes 2 0503 Roof Access 1 Total 50

LEVEL III, EXAM 8 - PLAN REVIEW 2 Hours - 50, Some questions refer to plans provided with the exam 01 Administrative Requirements 0101 Application of Administrative Requirements 2 02 General Requirements 0201 Major Occupancy Identification / Separation 2 0202 Occupant Load 1 0203 Types of Construction 1 0204 Fire Separations and Closures 2 0205 Fire Stops 1 0206 Flame Spread Rating, Smoke Development 1 0207 Firewalls 1 0208 Fire Resistance Ratings 1 03 Building Fire Safety / Classification 0301 Building Height, Size 4 0302 Spatial Separation 3 0303 Fire Alarm and Detection Systems 2 0304 Standpipe and Sprinkler Systems 1 0305 Lighting and Emergency Power 1 0306 High Buildings 1 0307 Access to Storeys, Routes, Access 1 04 Occupant Safety 0401 Safety within Floors 3 0402 Assembly Occupancies 2 0403 Care and Detention 1 0404 Residential 1 0405 Industrial 1 05 Exiting 0501 Exit Types, Number, Location & Fire Escapes 2 0502 Travel Distance & Distance Between Exits 1 0503 Exit Width, Height and Capacity 1 0504 Fire Separation of Exits 2 0505 Exit Signs 1 0506 Handrails, Guards, Stairs and Ramps 1 0507 Doors and Hardware 1 0508 Emergency Access to Floor Areas/Crossover 1 06 Vertical Transportation & Service Facilities 0601 Vertical Transportation 1 0602 Service Facilities 1 07 Health Requirements & Barrier-free Design 0701 Plumbing Facilities 1 0702 Barrier-Free Design 1 08 Structural Design 0801 Structural Design 1

09 Environmental Separation 0901 Heat, Air, Vapour, Moisture, & Sound Ratings 1 10 HVAC 1001 Design and Installation 1 Total 50 LEVEL III, EXAM 9 2 Hours - 60 01 Safety Within Floors 0101 Suite Separation 1 0102 Means of Egress 2 0103 Door Requirements & Number Egress Doorways 2 0104 Corridor Requirements 2 0105 Ramps, Stairways & Exterior Passageways 1 0106 Handrails and Guards 1 0107 Exhaust Ventilation 1 0108 Janitor and Laundry Rooms 1 02 Assembly Occupancies 0201 Fire Separations 1 0202 Fixed Seats and Fixed Bench Type Seats 1 0203 Aisles, Doors, and Corridors 2 0204 Guards and Risers for Stairs 2 0205 Stages 1 0206 Outdoor Places of Assembly 1 03 Care and Detention 0301 Fire Separations 1 0302 Doors and Corridors 2 0303 Hospitals and Nursing Homes 1 0304 Areas of Refuge 1 0305 Contained Use Areas 1 04 Residential 0401 Fire Separations 2 0402 Storage Rooms 2 0403 Egress 3 05 Industrial 0501 Repair and Storage Garages and Separations 3 0502 Multiple Tenant Self Storage 3 0503 Vestibules 2 06 Exits 0601 Types, Number & Location of Exits 2

0602 Travel Distance & Distance Between Exits 3 0603 Exit Width, Height and Capacity 4 0604 Fire Separation of Exits 1 0605 Exit Signs 1 0606 Handrails and Guards 2 0607 Stairs and Ramps 3 0608 Doors and Hardware 2 0609 Fire Escapes 1 0610 Emergency Access to Floor Areas/Crossover 1 Total 60 LEVEL III, EXAM 10 2 Hours - 60 01 Fire Alarm and Detection Systems 0101 Fire Alarm Requirements 3 0102 Continuity Fire Alarm System 1 0103 Types of Fire Alarms 1 0104 Installation & Testing 1 0105 Pull Stations 1 0106 Annunciator & Zone Indication 1 0107 Fire Detectors 2 0108 Audibility, and Visual Requirements 2 0109 Voice Communications 1 0110 Smoke Alarms 1 02 Standpipe and Sprinkler Systems 0201 Water Supply 1 0202 General Standpipe & Sprinkler Rqmts 5 0203 Hose Connections 2 0204 Hose Stations 2 0205 Fire Department Connections 3 03 Lighting and Emergency Power 0301 Lighting Requirements 3 0302 Emergency Lighting and Power 3 04 High Buildings 0401 Application 2 0402 Fire fighters, elevators 2 0403 Limits smoke movement 3 0404 Central Alarm and Control Facility (CACF) 2 0405 Venting 1 05 Building Fire Safety

0501 Exceptions to Building Height 2 0502 Storage garages 1 0503 Basements and Storage Below Ground 2 0504 Streets 1 0505 Multiple Major Occupancies 3 0506 Automatic Sprinkler Systems 1 0507 Construction Requirements 2 0508 Interconnected Floors & Mezzanines 5 Total 60