INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Similar documents
INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

INSTRUCTION MANUAL T154. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

INSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

INSTRUCTION MANUAL T-935-FO ANALOGUE. TECSYSTEM S.r.l. TECSYSTEM S.r.l. protection relays. 12 protection relays

RE-PR3-E-27 3-Phase Panel Mount 27kW

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Instructions for installation and use English. More documents on: H B /09

USE AND INSTALLATION HANDBOOK

GL-CO-RFG Channel Gas Leak Alarm System

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Service: to SLK Laboratory Hot Plates glass made of ideas

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

NT511 RS485 MODBUS INSIDE

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

MO n : 12JMC rév A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

AQUA IONIC USER S AND MAINTENANCE MANUAL

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

Operating Instructions. For. Alarm Control Module. Model SSR 500

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

LC3000 Level Controller Installation and Maintenance Instructions

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

USE AND INSTALLATION HANDBOOK

CTT8 TEMPERATURE MONITOR DEVICE

5, SE GÅNGHESTER,

General safety precautions English

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

A measured step forward

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima

Instruction Manual August sitrans CU 02

INSTRUCTION MANUAL NT935 IR. operates with ISO9001 certified quality system

Digital Electronic Thermostat With RF

Instruction Manual. Electronic gas and smoke detector GRM

Duct and Rough Service Carbon Monoxide Sensor

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Original operating instructions Safety switch with guard locking AC901S AC902S

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Laser Distance Sensor Type M Analog-Output

Fusion 200, 300 & 500

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

BX444-Mc Gas Detector

JS. Bosch Remote Control

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Instructions For Use ENG. LED Magnifier Lamp

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

OPTISENS TUR 2000 Technical Datasheet

USERS MANUAL FOR GAS BOILERS

AHD SPEED DOME CAMERA

L / -014L / -015L

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Quickheat 30 weather compensated boiler control

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

LC2200 Level Controller Installation and Maintenance Instructions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

MANUAL Oil Level Sensor

Digital Electronic Thermostat With RF

40KMC KMQ

Bimetal Disc Thermostat. Product Information and Application Notes

AUTOMATIC VACUUM UNIT

Deaf & Hearing Impaired RadioLINK Alarm System

MANUAL Overflow sensor NVF-104/34-PF

Original instructions Sense7-series Non-contact coded safety switch

Danfoss gas detection units

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

3M Benchtop Air Ionizer 963E. User s Guide

SCHMIDT LED Measured Value Display MD Instructions for Use

Dual Column Dehydrating Breather Manual

INSTALLATION INSTRUCTIONS

ETO 2 - Controller for ice and snow melting

TFD-1 Installation & User s Guide

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Flow Factor ~

INSTRUCTION MANUAL NT935 IR. operates with ISO9001 certified quality system

USER S GUIDE UTE202NP SERIES NON PROGRAMMABLE ELECTRONIC THERMOSTAT

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Thermal protection device for electric units

UV Flame Supervision System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

TECHNICAL MANUAL BlowerPack fan unit

Instruction manual for downdraft hood

Transcription:

INSTRUCTION MANUAL 1MN0107 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH Translations of the original instructions

INTRODUCTION First of all we wish to thank you for choosing to use a TECSYSTEM product and recommend you read this instruction manual carefully: You will understand the use of the equipment and therefore be able to take advantage of all its functions. ATTENTION! THIS MANUAL IS VALID AND COMPLETE FOR THE CONTROL UNIT CONTENTS PAGE 1) SAFETY REQUIREMENTS... 3 2) ACCESSORIES.. 4 3) TECHNICAL SPECIFICATIONS.. 4) FRONT.. 5 POWER SUPPLY.. 6 L1 - ALARM RELAY OPERATION. L2- TRIP RELAY OPERATION.. PTC SENSOR FAULT DIAGNOSIS.. "PTC" TYPE TEMPERATURE SENSORS.. 7 5) SENSOR / RELAY ELECTRICAL CONNECTIONS.. 6) WARRANTY CONDITIONS.. 8 7) TROUBLESHOOTING.. 8) EQUIPMENT DISPOSAL.. 9) USEFUL CONTACTS.. 2

SAFETY REQUIREMENTS ATTENTION : Read the manual carefully before starting to use the control unit. Keep the instructions for future reference. Do not open the device, touching any internal components can cause electric shock. Contact with over 50 Volts can be fatal. To reduce the risk of electric shock, do not dismantle the device for any reason. Moreover its opening would void the warranty. Before connecting the device to the power supply, make sure that all the connections are correct. Always disconnect the unit from the supply before any cabling modification. Any work on the equipment must be entrusted to a qualified engineer. Failure to comply with these instructions can cause damages, fires or electric shock, and possible serious injuries! POWER SUPPLY The control unit can be supplied by 240 Vac or 120 Vac, according to the model purchased. Before using it, make sure the power cable is not damaged, knotted or pinched. Do not tamper with the power cable. Never disconnect the unit by pulling the cable, avoid touching the pins. Do not carry out any connecting/disconnecting with wet hands. To disconnect the device, do not use objects such as levers. Immediately disconnect the device if you smell burning or see any smoke: contact technical service. LIQUIDS Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never touch with wet or humid hands during storms. If any liquid penetrates the control unit, disconnect it immediately and contact technical service. CLEANING Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, and compressed air. OBJECTS Never insert any objects into the cracks of the control unit. If this happens, disconnect the control unit and contact an engineer. USE RESERVED TO QUALIFIED PERSONNEL The purchased goods are a sophisticated electronic device that is totally unsuitable to be used by non-qualified personnel. Any intervention must be carried out by a specialist engineer. ACCESSORIES The use of non-original accessories or spare parts can damage the unit and endanger users safety. In the event of faults, contact technical service. LOCATION Install the control unit indoors, in a place protected from water splashes and sun rays. Do not place near heat sources exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations. Position the unit as far as possible from any intense magnetic fields. REPAIRS Do not open the control unit. For any fault, always use qualified personnel. The opening of the control unit and/or the removal of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all devices, any attempt to open the unit would break the seal and cause the consequent automatic forfeiture of the warranty. TECHNICAL INFORMATION Mail: ufficiotecnico@tecsystem.it tel: 02/4581861 3

ACCESSORIES The following objects are present inside the box: Control unit Start guide and QR code TECHNICAL SPECIFICATIONS 240 Vac 120 Vac POWER SUPPLY Supply rated values INPUTS 240Vac 50/60HZ 120Vac 50/60HZ 2 series of PTC inputs 1 series for L1 (ALARM) 1 series for L2 (TRIP) Input channels protected against electromagnetic interference OUTPUT 2 alarm relays (ALARM / FAULT AND TRIP) SPDT Output relays with 5A-250Vac-res COSФ=1 contacts. DIMENSIONS 70x90mm-depth 58mm (DIN track assembly) TESTS AND PERFORMANCES Construction in accordance with CE regulations Protection from electrical interference EN 61000-4-4 Dielectric strength 1500 Vac for a min. between output relays and sensors, relays and power supply, power supply and sensors 4

TECHNICAL SPECIFICATIONS 240 Vac 120 Vac Ambient operating temperature from -20 C to + 60 C Humidity 90% non-condensing ABS self-extinguishing housing NORYL 94V0 Absorption 2 VA Self-diagnostic circuit Protection treatment of the electronic part DISPLAY AND DATA MANAGEMENT Option Option 2 LEDs showing: ALL-L1 and TRIP-L2 1 LED showing the FAULT 1 LED indicating ON FRONT 1 2 4 3 1) Control unit supply (240 Vac or 120 Vac) according to the model purchased. 3) LED signal (ON-ALL L1-TRIP L2-FAULT) 2) Relays (ALARM/FAULT-TRIP) 4) L1 - L2 PTC sensor lines LED SIGNAL: LED ON: "ON" The device is powered correctly, "OFF" The device is not powered correctly ALL-L1 LED: "ON" L1 trip threshold exceeded, "OFF" temperature below the L1 trip threshold. TRIP-L2 LED: "ON" L2 trip threshold exceeded, "OFF" temperature below the L2 trip threshold. FAULT LED - ALL1 LED and TRIP-L2 LED flashing, see PTC SENSOR FAULT DIAGNOSIS on page 6. 5

POWER SUPPLY The control unit can be supplied by 240 Vac or 120 Vac, according to the model purchased 50/60Hz ±10%. Before powering the device, always check the supply parameters printed on the label. When the unit is supplied directly by the secondary of the transformer to protect, it can be burnt out by strong overvoltages. This happens if the main switch is closed and the transformer has no load (blank test). The above-mentioned problems are much more evident when the 220 Vac voltage is taken directly from the transformer secondary bars and there is a fixed capacitor battery to phase the transformer itself. To protect the monitoring device from line overvoltages, we suggest using the PT-73-220 electronic discharger, designed by TECSYSTEM S.r.l. for this specific purpose. L1 - ALARM RELAY OPERATION The L1 relay operates normally when the unit is powered and therefore the N.O. contact is closed. In case of an alarm on the L1 PTC or a fault in the monitoring unit itself, the relay gets de-energised with consequent closing of the N.C. contact. The L1 relay also has the same function as the PTC sensor FAULT. If this relay is triggered when the PTC sensor FAULT LED is FLASHING, it means that there is an error in the reading of a PTC sensor. It is possible to find it, thanks to a second LED flashing which corresponds to the FAULT channel. TRIP-L2 RELAY OPERATION The L2 relay is normally de-energized and energizes when there is an alarm on the L2 PTC. PTC SENSOR FAULT DIAGNOSIS If one of the PTCs is short-circuited or open you get the following warnings: Table 1 PTC alarm ALL-L1 FAULT + ALL-L1 LEDs are flashing PTC TRIP release TRIP-L2 FAULT+TRIP-L2 LEDs are flashing Characteristic values Resistance for PTC Measured voltage Resistance in the temperature span -20 C D NAT -20K From 20 to 250 ohms < 2.5 V- D NAT -5K resistance < 550 ohms < 2.5 V- D NAT+5K resistance > 1330 ohms < 2.5 V- D NAT+15K resistance > 4000 ohms < 7.5 V - impulsive 6

IMPORTANT NOTICE Before carrying out the isolation test of the electrical panel the control unit is installed on, disconnect it and the sensors from the power supply to prevent it from being seriously damaged. "PTC" TYPE TEMPERATURE SENSORS The PTCs can be compared to bimetallic thermostats where the contact opens and closes at the approximate temperature, defined as their operating characteristic ( NAT=operating temperature). The thermostat is calibrated for one temperature only that can vary from 60 to 180 C, in 10 C steps (60-70-80-90-100-110- 120-130-140-145-150-155-160-170-180). The electric contact of the bimetallic thermostat opens and closes at different temperatures, always approximately +/- of the operating temperature NAT. The difference between the opening and closing temperatures of the electric contact defines the operational differential of thermostat T. Very precise and expensive bimetallic thermostats can adjust the temperature at +/- 1 C of NAT; the normal bimetallic thermostats have an adjustment precision reaching 3-5 C. The PTCs are electronic thermometric sensors made with a chemical mixture that vary their electrical resistance according to the recorded temperature. There is a NAT (operating temperature) for the PTCs as well as for the bimetallic thermostats. The PTCs do not allow precision adjustments since the characteristic resistance values are fixed at 5 C and +5 K of NAT. The PTC characteristic resistance values are set by the DIN 44081 and 44082 standards. Since the PTC resistance curve is very rapid, in the section between NAT -5 C and NAT +5 C, it is quite difficult to make adjustments in a temperature span of less than +/- 5 K. If you use high temperature alarm systems, they obviously do not offer the device a high degree of precision. SENSOR / RELAY ELECTRICAL CONNECTIONS PTC SENSORS RELAYS CH1 CH2 CH3 L2 L1 COM STOP SYSTEM ALARM / FAULT CONDITION AUDIO AND VISUAL INDICATION The ALARM / FAULT relay operates normally when the unit is powered, therefore contact N.O. is closed. The above picture shows the state of the relays in non-alarm condition. 7

WARRANTY CONDITIONS The Product purchased is covered by the manufacturer's or seller's warranty at the terms and conditions set forth in the "Tecsystem s.r.l's General Conditions of Sale", available at www.tecsystem.it and / or purchase agreement. The warranty is considered valid only when the product is damaged by causes attributable to TECSYSTEM srl, such as manufacturing or components defects. The warranty is invalid if the Product proves to have been tampered with / modified or incorrectly connected and causing voltages outside the set limits and does not comply with the technical data for use and assembly, as described in this instruction manual. The warranty is always ex Corsico as stated in the "General Conditions of Sale". Tecsystem Srl is not responsible for damages caused by the monitoring unit due to PTC sensors which do not have the resistance features shown in table 1. N.B. To verify the correct operation of the monitoring unit in all its functions, we suggest you use the SIM-PTC simulator. TROUBLESHOOTING CAUSES AND SOLUTIONS The control unit does not switch on, the corresponding LED is OFF. Switch the unit off and check that: the connecting wires are tightened and there are no obvious burns on the connectors. One of the two PTC lines is in FAULT alarm Check the continuity and connection of the relative PTC line. EQUIPMENT DISPOSAL European directives 2012/19/EC (WEEE) and 2011/65/EC (RoHS) have been approved to reduce electrical and electronic waste and promote the recycling and reuse of the materials and components of this equipment, cutting down on the disposal of the residues and harmful components of electrical and electronic materials. All the electrical and electronic equipment supplied after 13 August 2005 is marked with this symbol, pursuant to European directive 2002/96/EEC on electrical and electronic waste (WEEE). Any electrical or electronic equipment marked with this symbol must be disposed of separately from normal domestic waste. Returning used electrical devices: contact TECSYSTEM or your TECSYSTEM agent for information on the correct disposal of the devices. TECSYSTEM is aware of the impact its products have on the environment and asks its customers active support in the correct and environmentally-friendly disposal of its devices. USEFUL CONTACTS TECHNICAL INFORMATION : ufficiotecnico@tecsystem.it SALES INFORMATION : info@tecsystem.it 8