Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Similar documents
ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Nov 08 PRODUCT SPECIFICATION SHEET

Specification , July 2015

Advanced Test Equipment Rentals ATEC (2832)

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

/8 DIN Level Indicator

Temperature Controllers

Low Temperature Zirconia Oxygen Analyzer

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

I/A Series 716C 1/16 DIN Temperature Controller

UDC100 Universal Digital Controller Specifications

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Process Alarm Module RTA 421

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

RTD TEMPERATURE SENSING SYSTEM

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

General Specifications

Installation Manual Tracker 221

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Instruction Manual Model A

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

ESSEX ENGINEERING CORPORATION

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

LC1350 Level Controller

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Analog Input Module IC670ALG630

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Datasheet: K-22 LO Sensor

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Mark 25 Ultrapure Water Conductivity Analyzer

Alternative Fuel Fueling Stations

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Pump-Up Controller MODEL 4062

Two-Channel Gas Controller

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

DGC-500 DIGITAL GENSET CONTROLLER

AN-3100D Annunciator

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Pump-Down Controller MODEL 4052

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

DIGITAL METERS Large Display Temperature Meters Instruction Manual

02/11/2015

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

02/11/2015

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Table of Contents SECTION PAGE

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Carbon Monoxide Transmitter

Model 1062 Environment Monitor

Flopurge TS. Operation Manual

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

7EF/7HF/7EC/7ES Temperature Controllers

Engineering Guideline. pac- Carriers Type Universal

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Centro-Matic Automated Lubrication Systems System Controls

CTT8 TEMPERATURE MONITOR DEVICE

Speed and Frequency Seite 1 von 7

Controllers. Instruction Manual WARNING

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MEAS CAL ALARM WASH CONF APT4000 TC

Dissolved Oxygen Analyzers

Series Temperature Controller Instruction Sheet

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Variable Frequency Drive SERIES MP800 VFD

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Universal Input Digital Panel Meter With Bargraph, NA3

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

F4 Process Controller Installation and Operation Guide

Instruction Manual WARNING

MO n : 12JMC rév A

Figure 1 DirectLine DL423 Sensor. Description, continued

Model 96VTR ¼ DIN Process Controller

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

MICROJET RECORDER (180mm)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

ESP TECHNOLOGIES LIMITED

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3490 Series

Toroidal Conductivity Transmitters Series APT4000 Specifications

Transcription:

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Four Channels of Process Variable Bargraph Indication Four Channels of Integration and Digital Totalization An Alarm/Annunciator Summary Intuitive Operator Interface Standard RS-485 Data Link Built in 24 Vdc 80 ma. Transmitter Power Supply 53IT5100 Micro-DCI 4 Channel Indicator Totalizers Specification Sheet

53IT5100 INDICATOR/TOTALIZER The 53IT5100 Indicator / Totalizer provides up to four channels of process variable indication on one 1/2 DIN instrument faceplate. It has a high visibility dot matrix display that permits process variable indication and totalization values to be displayed in a clear and concise manner. TWO CHANNELS OF INDICATION Figure No. 2 is one of the two channel indicator displays available in the unit. Two channels of indication allow the end user to display only the two channels that are critical to the process. This allows an uncluttered presentation of information showing only two points of indication. The cover picture is the standard format, 53IT5100 four channel display. The process variable inputs are displayed in bargraph format, while selected input is digially repeated. The instrument's six displays are sequentially organized and can be paged by using the 1 and 2 pushbuttons along the bottom of the display. A ten digit decimal readout complements the process variable bargraph indication. Each channel of the 53IT5100 has the ability to show individual tagnames, input range, and user specified engineering units. Each of the four input channels has full alarm capabilities. Each Channel Has an Associated Integrator Circuit and Totalizer Figure No. 1 is a four channel integrator / totalizer display. The display has individual, user selectable tagnames and engineering units configurable to best represent the individual process. The digital totalizing of the unit has a resolution of a 10 digit floating point number. This allows larger, more accurate totals of the process. Figure No. 2: Two Channel Process Variable Bargraph Indication INPUT / OUTPUT The 53IT5100 can accept four analog inputs. Each input channel is able to receive any one of the four following process variable signals: 0-20 ma. 0-5 volts 1-5 volts 4-20 ma. Each channel has selectable square root extraction capabilities and the unit can retransmit any analog input to the analog output provided. Figure No. 1: Four Channel Integrator/Totalizer Function with (10) digits of Decimal Resolution 2

OPERATOR INTERFACE The 53IT5100 Indicator / Totalizers dot matrix display provides unequaled presentation of information to the user in a stand alone instrument. The combination of displays offered and the front panel interface provides a broad range of operator interaction, far beyond the capabilities of traditional panel mounted units. ALARM SUMMARY The alarm summary screen displays at a glance the status of the alarms for the four analog inputs and the two contact inputs provided. The legend at the top of the display identifies the alarm group. The current status of up to four process variables and two contact inputs is shown directly below it. Each of the four analog inputs has an independent programmable alarm function based on the process variable exceeding predescribed limits as outlined below. PA = Process Alarm, PL = Process Limit : 0 - PA1 = HI Alarm when PV > PL1 PA2 = LO Alarm when PV < PL2 1 - No Alarms 2 - PA1 = HI Alarm only 3 - PA2 = LO Alarm only 4 - PA1 = HI Alarm when PV > PL1 PA2 = HI-HI Alarm when PV > PL2 5 - PA1 = LO Alarm when PV < PL1 PA2 = LO-LO Alarm when PV < PL1 COMMUNICATIONS The 53IT5100 includes a standard RS-485 communications port. This port has connections directly on the rear terminal of the unit. The unit can be linked directly to a Micro-PWC workstation and can co-exist on a multi drop datalink with other Micro-DCI instruments. Individually addressable, up to 32 instruments can communicate at speeds up to 28,800 bits per second. The 53IT5100 has a standard RS-232 communications port. This port is accessible from the front of the instrument. All internal functions of the 53IT5100 are accessible through either of the two input ports. The 53IT5100 has the features that your process demands contained in a Compact 1/2 DIN size case (72 x 144 mm) and only 327 mm deep. Four channels of indication, four channels of totalizing, 6 Points of alarm status, six different types of alarm configurations. DataLink communications, two power input capabilities (120/240 Vac - 24Vdc) two contact inputs, two alarm outputs, 100 msec scan rates, analog retransmission, an industry leading high visibility plasma gas display. No other indicator offers plant operators the information and display flexibility found in the Model 53IT5100 Indicator / Totalizer. When a process variable becomes abnormally high or low, or when one of the status contact inputs changes state a flashing "ALARM" message appears at the top of the current display. Incoming alarms can be acknowledged by pressing the pushbutton on the faceplate stopping the "ALARM" message. If a process variable ALARM condition continues it is shown by a flashing bargraph display. When the process variable returns to its normal range the bargraph stops flashing. Two Contact outputs are provided which can report ALARM conditions to external devices (See Figure No. 3). 3

Engineering Specifications OPERATING CHARACTERISTICS Power Requirements: 21-28 VDC 120 VAC +/- 10% @ 50-60 Hz 220/240 VAC +/- 10% @ 50-60 Hz Power Consumption: AC operation: 15 Watts max Internal Power Supply Available Power Output for Transmitters: 24-26 Vdc, 80 ma, short circuit protected Output Ripple: 200 mv p-p maximum ENVIRONMENTAL CHARACTERISTICS Enclosed temperature controlled locations (class A and B per ISA S71.01 1985) Ambient Temperature Limits: 4 to 52 C Relative Humidity Limits: 10 to 90% maximum Temp. Effect on Accuracy: +/- 0.28% per 28 from reference temperature of 25 C. Enclosure Classification: NEMA type 1 PHYSICAL CHARACTERISTICS Case: Finish: Circuit Boards: Bezel: Dimensions: Steel Baked enamel, Lt. Gray RAL 9002 Glass epoxy ULTEM 1000 UL-94 1/2 DIN case (72 x 144 mm) Electrical Component: Rear of Case: Compression type Front Panel: N/A Display: 96 x 48 Pixel Push Buttons: 10 (Tactile membrane type switches) Analog Inputs (All analog inputs are referenced to signal common.) Quantity: 4 Standard Signal Range: 0-5 or 1-5 V linear or square root Input Impedance: 1 megohm minimum for voltage inputs; value of ranging resistor for current signals. Measurement Accuracy: +/- 0.1% of span Contact Inputs Figure No. 3: Six Point Alarm Annunciator Display Quantity: 2 Type: Discrete inputs internally powered with 4 volts @ 2 ma dc maximum (contact inputs are referenced to power com mon.) Permissible Contact Resistance: 100 ohm maximum Open/Close Contact Duration: for open recognition: for close recognition: 0.05 s minimum 0.05 s minimum 4

Contact Recognition Level Closed: 1 V dc max or less than 100 ohms Open: 4 V dc to 15 V dc or 10 ma max OUTPUT SIGNALS (All Analog Output signals are referenced to power common.) Quantity: 1 Standard Signal Range: 0-21.84mA dc (4-20 ma dc typically) Load Resistance: 0-640 ohms for dc powered units,0-900 ohms for ac powered units. Accuracy: +/- 0.2% of span (Current output is updated every 0.1 seconds. The output slew rate is 40 ma / Sec. Discrete Outputs Quantity: 2 Type: Unpowered discrete solid state output. Configuration: Single pole single throw, N.O., or N.C. references to power common. Voltage: 30 V dc max. Current: 50 ma dc max. MICROPROCESSOR SAMPLING & UPDATE Program scan rate: 100 ms. Input Signal Sampling Rate Analog: 50 ms for all inputs Contact: 50 ms for all inputs Display Update: 100 ms. COMMUNICATIONS Standard MICRO-DCI data link Type: RS422/485, four wire, asynchronous Speed: Selectable - all standard baud rates between 300 and 9600; plus 14,400 and 28,800 Mode: Binary 5

Model Number Designation Model Number 53IT51 A 2 1 A B 07 08 09 10 11 12 13 14 4-Channel Indicator Totalizer 53IT51 Power Requirement AC 110/120, 220/240 VAC 50-60 HZ... 1 DC (24 Vdc)... 2 Functionality Standard... 1 Standard with Factory Configuration (Note 1)... 2 Design Level... A Enclosure Type DIN 72 x 144mm Bezel... 2 Rear Terminal Board Standard Rear Terminal Board... 1 Chassis Standard Chassis...A Safety Classification Factory Mutual Class 1, Div. 2.... B Conformal Coating Not Required...X Required... A Note 1: Configuration consists of entering tags, engineering units alarm limits, totalizer display step, rollover value, and other applicable parameters. If factory configuration is selected, the instrument configuration worksheet must be completed and sent in with the instrument order. www.micromodautomation.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (05.5.04) MicroMod Automation, Inc. 2004 MicroMod Automation, Inc. 75 Town Centre Drive Rochester, NY 14623 Tel: (585) 321-9200 Fax: (585) 321-9291 Email: sales@micmod.com 6