The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

Similar documents
Low GWP alternative refrigerants to R404A

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com

ion at rm o l Inf ra ne e G General Information ǁǁǁ ƌğljŵž ĐŽŵ 7

Magnetic Refrigeration. Study Case

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

This presentation is posted for public use. ACEEE does not endorse any product or service.

3 GWP 290 DLE COMPRESSORS NLE/NLY COMPRESSORS SCE COMPRESSORS ENERGY-OPTIMIZED PROPANE COMPRESSORS

The Current Path of Refrigerants

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Be sustainable while protecting your business

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Natural refrigerant trends in EU, Japan & North America

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Test Results from the AHRI Low GWP AREP II (Alternative Refrigerant Evaluation Program) Transport Refrigeration

The Industry s Most Complete Refrigeration Source

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Embraco Position Paper: Light Commercial Refrigeration

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Hydrocarbons as refrigerants

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Evaluation of HCFC Alternative Refrigerants

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

OIL-FREE COMPRESSOR. Let s write together a new chapter in the refrigeration history.

FACT SHEET 6 Transport Refrigeration

Reduce everything but reliability

COMPANY Presentation Focus on SANDEN Environmental Solutions

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Advantages of R290 (Propane) and other hydrocarbons

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

2016 Synthetic Greenhouse Gas Levy Report

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

SOLSTICE L40X (R-455A)

THE CHEAPEST WAY TO HEAT YOUR WATER

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Understanding Applications for Alternative Refrigerants

Transcritical CO2 Bottle Cooler Development

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Refrigerants & Cooling in renovation buildings

Criteria of the German Ecolabel ("Blue Angel") for Stationary Air Conditioners

Product Offering for 2017

DOE and EPA Impacts to Commercial Refrigeration

Global Solutions for Ammonia Industrial Refrigeration

HFO-1234yf Performance in a Beverage Cooler

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

TEST REPORT #2. System Drop-in Test of L-40, L-41a and N-40b in Ice Machines

HYDROCARBON REFRIGERANT SYSTEM COMMISSIONING REPORT. Duvel International Trading (China) Limited

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

Large AC units using a variety of low-gwp options

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Understanding Applications for Alternative Refrigerants

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Design of LPG Refrigeration System

Overview of New Refrigerants and Expected Market Trends

Effectively Managing the Transition to Lower GWP Refrigerants

Chapter 2. Alternatives to HCFCs and their Characteristics

ENVIRONMENT-FRIENDLY HEATING WITH R290 HEAT PUMPS. Dr. Joachim Maul - Brussels, 15th of October 2013

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

EN aquatech.piovan.com

Chillers for High Ambient Conditions: What Technologies and Fluids?

Exhibition Hall 1. Fachprogramm. Technical Programme

COMPARATIVE STUDY OF NEW ECOLOGICAL GASES

Ultra low temperature freezers. -40 C and -86 C. Green Line

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

New Refrigerants & Selecting Capital Equipment

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Presented By: John Dolan, P.E.

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

CO 2 transcritical FTE System Full Transcritical Efficiency

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

2017 Synthetic Greenhouse Gas Levy Report

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Refrigerants Type Expensive Coefficient of Performance Toxic

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Chapter 10. Refrigeration and Heat Pump Systems

Transcription:

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator Vicente Guilabert HUAYI COMPRESSOR BARCELONA, S.L

The Company Huayi Compressor Barcelona, S.L. The Product Hermetic Compressors and Condensing units for Light Commercial Refrigeration For all types of applications High Efficiency Compressors Variable Speed Compressors DC Compressors Green Cooling Ranges The advanced design of the Green Cooling Ranges allows: Efficiency improvement (up to 50% compared to standard versions). Lower CO2 emissions to the atmosphere. Use of natural refrigerants as R290 with no direct effect on global warming. Additional COP improvement because of moving from HFCs to HCs. Efficiency improvement up to 50%

Refrigerant trends Refrigerant trend

USA policy trend EPA SNAP EPA SNAP Policy From 2015, 4HC s approved: q R600a and R441A q R600a, R290 and R441A q R290 and R441A q R170 q R290 Stand alone commercial refrigerators and freezers. Vending Machines Residential and light commercial AC and Heat Pumps Very low temperature and heat transfer Household refrigeration SNAP De-listing HFC s: q High GWP HFC s (R404A and R134a) 2019/2020 for stand-alone units

HC s Market Evolution Market Demand Δ60% % of HC s compressors vs. total sales volume F-GAS REGULATION Δ67% Δ42% Δ50% Δ64% Δ3% Δ104% Δ0% Δ0% Δ223%

Case of Study Huayi Compressor Barcelona, S.L. Objective of the Study Why Propane? The objective of the study is to reduce the energy consumption on a ice cream conservator using a High SUSTAINABLE COOLING efficiency R290 LBP fixed speed compressor. Methodology The Compressor: NUT60LR NATURAL REFRIGERANT The appliance Test results Main advantages LOW ENERGY CONSUMPTION Conclusions

Case of Study The compressor: NUT60LRb Top efficiency fixed speed compressor NUT60LRb The new U Range offers to the market the most efficient compressors in its series. This U Range has been designed using the most advanced technologies to minimize the energy consumption while offering a high cooling capacity. Model Displacement (inch3) Capacity (Btu/h) EER (Btu/Wh) Motor +48% EER NL60FR 0,359 933 3,89 CSIR NLY60LRa 0,359 1190 4,85 CSIR NLY60LRb 0,359 1190 5,22 CSR NUT60LRa 0,366 1250 5,46 CSIR NUT60LRb 0,366 1250 5,90 CSR ASHRAE32 conditions Voltage range: 115-127V 60Hz

Case of Study The appliance Tested appliance main characteristics Application Characteristics and Test Conditions Type of cabinet Refrigerant Internal net volume Cabinet load Ice cream conservator R290 245 Liters Fully loaded Ambient temperature / RH 86ºF / 55% Average internal temperature -0,4ºF Test Results Data NL60FR NLY60LRa NLY60LRb NUT60LRb Evaporating temperature (ºF) -30,8-30,4-29,8-31 Condensing temperature (ºF) 102,2 103,1 103,6 102,9 Inlet cabinet temperature (ºF) -1,48-1,31-1,35-1,32 Duty cycle (%) 82,3% 80,9% 81,1% 79,60% Energy consumption (kw h/24h) 3,44 3,11 2,85 2,06 Up to 40% energy savings Energy consumption difference vs cabinet with New U compressor - -9,75% -17,20% -40,04%

Case of Study The appliance Tested Results Up to 40% energy savings

Case of Study Pay-Back Accumulated in 5 years Data NL60FR NLY60LRa NLY60LRb NUT60LRb Total energy consumption (kwh) 6278 5676 5201 3760 Total energy consumption savings vs std (kwh) - 602 1077 2518 Total energy cost savings (US$) (*) - -78,86-141,09-329,86 Savings per day vs std (US$) - -0,04-0,08-0,18 CO2 emissions (kg CO2) (***) 2825 2554 2340 1692 CO2 emissions reduction vs std (kg CO2) (***) - -270,90-484,65-1.133,10 (*) 0,131 $/kwh average energy cost in USA (***) Supposing 0,45kg CO2 emissions for each kwh

Case of Study Conclusions R290 advantages vs other alternative gas refrigerants for light commercial Refrigeration: R290 one of the best environment friendly alternatives (excellent GWP). R290 already EPA SNAP approved: Global refrigerant solution. R290 applied in the most efficient appliances produced in Europe from last years with very positive results with million units running. R290 systems do not requires significant changes vs current HFC s and vs other ecological alternatives (CO 2 ) (Reasonable working pressures). R290 allows the use of lower displacement compressors vs R134a and R1234yf to get equivalent cooling capacity. Weak point of R290 is the limitation of 150 g charge per circuit (which cover most of light commercial appliances charge). Restriction under discussion to extend the maximum charge but estimated to short-middle term.

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator by Vicente Guilabert - Huayi Compressor Barcelona Thank you very much!.