PROCESS AND CLIMATE COOLING

Similar documents
PROCESS AND CLIMATE COOLING

VENTILATION AND AIR CONDITIONING TECHNOLOGY

Air-conditioning and climate-control technology

Menerga Adconair Various solutions one heat recovery system

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

EN aquatech.piovan.com

System overview. Indoor swimming pool air conditioning Comfort air conditioning Process air conditioning

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

PRODUCT DATA SHEETS HEAT PUMPS

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

water-cooled CHILLERS

50A KP 70A KP 90A KP 120A KP 150A KP 210A

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

water-cooled CHILLERS

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Systems engineering Slide 1

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

CO 2 REFRIGERATION MACHINES AND HIGH TEMPERATURE HEAT PUMPS.

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Energy efficient swimming pools 1.1 A SMART, EFFICIENT CLIMATE SHELL REFURBISHMENT SOLUTION

Submittal Data Performance Data Electrical Data

LG Electronics AE Company, Commercial Air Conditioning

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Compressors Manufacturing Company Ltd.

LG Electronics AE Company, Commercial Air Conditioning

AIR COOLED CONDENSING UNITS

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Sub-Critical Operation of the CO2 Expander/ Compressor

The Refrigeration Cycle

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

MOBILE DEHUMIDIFIERS. Dehumidifier with adsorption rotor. Mobile dehumidifiers. Quality with systems

HVAC Water chiller selection and optimisation of operation

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Make value of the waste energy from your cooling units and heat water for free

ACZ SERIES AIR COOLED AND HEAT PUMP MULTISCROLL CHILLERS R-410A

The Refrigeration Cycle

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

THE HEART OF YOUR COMFORT

Natural geothermal energy

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control. Refrigeration Granulation

Water and ground source heat pumps 61WG kw. Heating

Oil-injected rotary screw compressors GA GA

Brazed Plate Heat Exchanger for CO Applications

WATER-COOLED CHILLERS and condenserless chillers

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

R134a. DCLC Series 50Hz. Water Cooled Centrifugal Chillers Cooling Capacity: 300 to 1500 TR (1055 to 5274 kw)

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

echiller R718 refrigeration system

Refrigerator and Air conditioner Testing in the Republic of Korea

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

CASE STUDY AIR-CONDITIONERS

WHY A MHI HEAT PUMP?

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Overview and Decision Guidance. Buildings & Locking Systems

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

QUANTUM. Series and features of the energy-efficient chiller series

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Reinventing Energy Efficiency

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

HIGH-POWER HEAT PUMPS. Up to 300 kw

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Air to Water Heat Pump Utilising Natural Refrigerant C02

Air Cooled Packaged Systems AIRAH Back to Basics

ULTRATEMP HIGH PERFORMANCE HEAT PUMP

kw COOLING kw HEATING

New Bitzer factory: Higher precision with air conditioning

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Reinventing Energy Efficiency WARMNESS.

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Air to water Heat Pump System

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

Spacemaker. High Performance Air Conditioning. English

Eco Compact Series GAS HEAT PUMP

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

F-H Refrigerated Dryers

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

F Series - Refrigeration dryers

SWIMMING POOL HEAT PUMPS

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

recooler HP EQKR HEAT PUMP

System overview. Indoor swimming pool air conditioning Comfort air conditioning Process air conditioning

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Transcription:

PROCESS AND CLIMATE COOLING Cold and warm water system Creating a good indoor climate.

cold AND warm WAter SYstem Cold & warm To heat AND cool down AT the SAme time! If we are suffering from heat, our effectiveness and motivation decrease. Therefore, it is better to avoid this situation right from the beginning by means of modern technology. Cold water for all areas of application Cooling with cold water is used in the most varied areas: Be it the removal of excess heat in thermally highly-stressed rooms, the cooling of industrial manufacturing processes or the comfortable air conditioning of buildings like office and business buildings. The made-to-measure product range of Menerga offers the optimal designed cold water set for any kind of application. But what to do if there is also need for heating? In modern buildings and industrial plants, next to cooling requirements there is also a more or less constant year-round heat requirement: warm water for radiators, for service water or air heating for air conditioning. As a basic rule, additional, cost-intensive use of primary energy is required to satisfy this need for heat. This incited our design engineers to develop a new system which is resource-saving and according to the Menerga philosophy is able to take on both jobs with the lowest technical possible energy use at all. This helps to reduce the use of primary energy without cutting back convenience. Chilled water unit with heat pump function The Cowatemp Series with integrated heat pump function is used in addition to our Hybritemp device series at all places where not only cold is required but, at the same time, also heat. A separate heat supply according to the requirements, e. g. for warm water and heating purposes, is available as optional upgrade. The efficiency of this chilled water unit is based on the primary use of excess heat from cold production for warm water supply (heat pump function). Particularly during the transitional periods of seasons (fresh air around 5 to 20 C) it is possible to achieve extremely low operating costs if cold and heat requirements are more or less identical. Menerga areas of application: Cold and warm water system Low-energy buildings Museums / Galleries Theater Historical buildings Sports facilities Swimming pool halls Private pools Hotels / Restaurants Clinics Schools / Universities Shopping Centers Offices / Administration buildings Banks Industry 2

cold AND warm WAter SYstem For a good partnership Whether design engineer, architect, plumber, building operating company or owner we place our complete knowledge at our customer s disposal for coping with your daily tasks. Also after installation, our proven service will help you with words and deeds. Quality forms the basis Quality is as important to us as to our customers. It is self-evident to us to deliver faultlessly operating and optimally adjusted equipment. You may assure yourself of it even before delivery, being our guest during the test run at the workshop. ADVANTAGES To cool and to heat at the same time steplessly adjustable, independent from each other Different heat sources may be used, like return air Conference room in the Green Building, Slovenia According to its use, only a small buffer storage or even none may be necessary on the heating side Simple and cost-efficient assembly, because only the water pipes of the building are necessary, but not the coolant pipes Energy-saving fan with pressure reserve for additional noise dampening and capacity according to the requirements due to infinitely variable control. Integrated control, easy to integrate into any building control system Car center in Fellbach, Germany Low operating costs due to heat recovery 3

cold AND warm WAter SYstem Company Stihl in Waiblingen, Germany Company Marposs in Weinstadt, Germany Type 95 10 01 4

cold AND warm WAter SYstem DETAils which are right EVEry time! Adjustment Menerga delivers all air conditioning equipments with an adjustment that matches the requirements of the project. This facilitates commissioning and subsequently guarantees the efficient operation of the system. Fan unit The frequency converter controlled fan unit, type solvent, guarantees an optimum operation due to the permanent measurement of the actual air flows. At the same time, safety ranks first. Permanent monitoring of oscillations, rotational speed, flows and tensions are self-evident. Compression cold installation The integrated compression cold installation / heat pump is equipped with the latest state-of-the-art components. From the standard expansion valve to analogue pressure sensors, an energy-efficient operation is guaranteed for all operation modes. Stepless power modulation over a range from 10 % to 100 %. The power input decreases proportional to the generated refrigeration capacity. 5

cold AND warm WAter SYstem ThAT s how it works: Menerga Type 95 Cowatemp Cooling mode Outside Air Hotwater Coldwater K Exhaust Menerga Type 95 Cowatemp Heating mode Outside Air Hotwater Coldwater K Exhaust Cooling and heating mode Outside Air Exhaust Heating and cooling mode Outside Air Exhaust Hotwater Hotwater Coldwater K Coldwater K Operation for cooling requirements only and operation if the cooling requirements are higher than the heating requirements The capacity of the coolant compressor adjusts to the higher cooling requirements. The desired flow temperature of the cold water is steplessly adjusted by adjusting the capacity of the refrigerating machine. That part of heat taken from the cold water and necessary to heat up the warm water circuit to the desired temperature is transferred to the warm water in the warm water condenser. Only the part of the condensation heat which is of no use in the building escapes into the ambient air via the air condenser. The rotational speed of the fan sets the air flow rate to the flow rate which is necessary for transferring the excess heat. Operation for cooling requirements only and operation if the heating requirements are higher than the cooling requirements The capacity of the coolant compressor adjusts to the higher heating requirements. The desired flow temperature of the warm water is steplessly adjusted by adjusting the capacity of the refrigerating machine. The necessary heat for heating up the warm water circuit to the desired temperature is basically taken from the cold water circuit in the water evaporator. Additionally, the necessary amount heat for balancing the heat balance is taken from the ambient air in the air evaporator. The rotational speed of the fan sets the air flow rate to the necessary flow rate for the heat supply. 6

cold AND warm WAter SYstem DATA You will NEED! Compact chilled water unit with heat pump function Equipment types 95 Cowatemp 95 05 01 95 08 01 95 10 01 95 13 01 95 16 01 95 19 01 95 25 01 Cooling and heating capacity 1) Supply / return flow 16,0 / 20,0 C kw 18,3 32,6 36,8 53,8 62,9 73,5 107,3 Compressor rated input kw 5,0 8,8 10,0 15,5 17,3 19,9 31,2 Cooling performance EER 3,7 3,7 3,7 3,5 3,6 3,7 3,4 Cooling performance 2) cold water Supply / return flow 35,0 / 32,0 C kw 12,3 22,2 24,6 36,8 41,1 49,2 73,5 Compressor rated input kw 3,7 6,6 7,4 11,1 12,4 14,8 22,2 Heating performance COP 3,3 3,4 3,3 3,3 3,3 3,3 3,3 Heating capacity 3) warm water Cold water FL / RF 16,0 / 20,0 C kw 21,9 38,6 43,9 65,8 75,0 87,8 131,7 Warm water FL / RF 35,0 / 32,0 C kw 25,7 45,1 51,4 77,1 87,9 102,9 154,3 Compressor rated input kw 3,8 6,5 7,5 11,3 13,0 15,1 22,6 Cooling performance EER 5,8 5,9 5,9 5,8 5,8 5,8 5,8 Heating performance COP 6,8 6,9 6,9 6,8 6,8 6,8 6,8 Nominal air output m 3 / h 4.600 8.000 9.500 12.600 15.800 19.000 25.000 COP = Coefficient of performance EER = Energy Efficiency Ratio 1) simultaneous cold & warm water generation 2) 100 % heating capacity at fresh air = 32 C; 40 % r.h. 3) 100 % heating capacity at fresh air = -5 C; 90 % r.h. Subject to technical changes without notice Green Building of Menerga Slovenia 7

menerga Gmbh Gutenbergstraße 51 45473 Muelheim an der Ruhr Germany Phone +49 (0) 2 08-99 81-0 Fax +49 (0) 2 08-99 81-110 E-Mail info@menerga.com Links to your local sales offices at www.menerga.com Menerga is represented throughout Europe WBD00058 Cold and warm water system Type 95 Cowatemp 03/2009 Englisch Mixed Sources Product group from well-managed forests and other controlled sources Cert no. GFA-COC-001696 www.fsc.org 1996 Forest Stewardship Council

menerga Gmbh Gutenbergstraße 51 45473 Muelheim an der Ruhr Germany Phone +49 (0) 2 08-99 81-0 Fax +49 (0) 2 08-99 81-110 E-Mail info@menerga.com Links to your local sales offices at www.menerga.com Menerga is represented throughout Europe WBD00058 Cold and warm water system Type 95 Cowatemp 03/2009 Englisch Mixed Sources Product group from well-managed forests and other controlled sources Cert no. GFA-COC-001696 www.fsc.org 1996 Forest Stewardship Council