Menerga Adconair Various solutions one heat recovery system

Similar documents
Air-conditioning and climate-control technology

PROCESS AND CLIMATE COOLING

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

PROCESS AND CLIMATE COOLING

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

System overview. Indoor swimming pool air conditioning Comfort air conditioning Process air conditioning

Adsorption Chillers Energysmart Green Cooling

Desiccant Cooling with Solar Energy

FACT SHEET 9 Large Air-Conditioning (air-to-air)

VENTILATION AND AIR CONDITIONING TECHNOLOGY

Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

» WITH REGASORP ROTARY HEAT EXCHANGER

recooler HP EQKR HEAT PUMP

Colt CoolStream Adiabatic Cooling & Ventilation System

investment in R&D, the commitment to - name.

FACT SHEET 9 Large Air-Conditioning (air-to-air)

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Efficiency in the smallest space

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

A NEW STANDARD FOR COOL COMFORT

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Oxyvap Evaporative Cooling Applications

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex.

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

The regenerative cooling system. Ka 2 O. Co-funded by the Eco-innovation Initiative of the European Union

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

System overview. Indoor swimming pool air conditioning Comfort air conditioning Process air conditioning

Liquid desiccant dehumidification systems. Product guide

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Heat pump and energy recovery systems

100% Outdoor Air Dehumidification Methods

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

DEHUMIDIFICATION ADVANTAGES FOR WATER TREATMENT PLANTS

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Chapter 14, Problem 27.

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Natural geothermal energy

Solar Air-Conditioning and Refrigeration - Introduction

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

ENGINEERING AND CONSTRUCTION BULLETIN

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

Benefits Offered by Passive Dehumidification Wheel Speed Control

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

A-DRY Heatless adsorption compressed air dryers

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Variable refrigerant flow (VRF) systems

container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr

Thermodynamics II Chapter 6 Mixtures & Psychrometry

COTES ALL-ROUND THE C105 RANGE

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

RENNER SCREW COMPRESSORS WATER-INJECTED 100% OIL-FREE COMPRESSED AIR Made in Germany

ARCTIC EVAPORATIVE COOLING. Direct Evaporative Coolers Indirect Evaporative Coolers Dew Point Evaporative Coolers

Industrial cooling systems LT

Armstrong Cool-Fog Systems

Air conditioning. EcoCond EcoCond+

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

CO2 TRANSCRITICAL BOOSTER SYSTEMS

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Dynamic performance of a novel dew point air conditioning for the UK buildings

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

QUANTUM. Series and features of the energy-efficient chiller series

Psychrometric Engineering Applications

HVAC Mandatory Provisions Part II, Page 1

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

MAXIMIZING FACILITY PERFORMANCE WITH INNOVATIVE HVAC & IRRIGATION SYSTEMS

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

R07. Answer any FIVE Questions All Questions carry equal marks *****

Trane CDQ Desiccant Dehumidification

Eco Compact Series GAS HEAT PUMP

clean, dry compressed air

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Energy Recovery Ventilation

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Heat pump systems and Chillers

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Easy dry line REFRIGERATION AIR DRYERS. With VSCC exclusive patented variable speed system

Solutions for. HVAC/Refrigeration. Axial Fans and Clutches

Transcription:

Menerga Adconair Various solutions one heat recovery

MINIMAL ENERGY APPLICATION MENERGA Menerga has developed and produced innovative ventilation and air conditioning s for extensive fields of application since 980. We can safely claim that our technology is the leader throughout these areas, and that we set the benchmark for efficiency and effectiveness. Our philosophy Creating a good indoor climate through Minimal ENERGy Application is our guideline, in which we have succeeded every single day since the company was founded. We are proud that Menerga from its very beginning was one of the first companies to focus on energy efficiency. And, on the basis of this orientation, we have created many efficient solutions, if sometimes along somewhat unconventional paths. Europe-wide sales and service network Founded in Mülheim an der Ruhr, Germany, in 980 Europe-wide presence (sales and service) Menerga Market segments Over 40,000 installed units worldwide More than 5 years of experience in adiabatic s Approx. 00 research & development engineers groupwide Service Part of the Systemair Group since 0 CO emission of a car with a mileage of.6 billion km Heating energy consumption of the city Mülheim an der Ruhr with 70,000 inhabitants SAVINGS OF Heating energy consumption of approx. 80,000 apartments (00 m²) * *Average savings by Menerga solutions in the period 0 until 06. Kilometers traveled by cars driven by 5,000 sales employees Adconair overview 07/06/EN Subject to technical modifications. Menerga GmbH www.menerga.com

FULL COUNTERFLOW HEAT RECOVERY Adconair heat recovery technology sets high standards with its counterflow plate heat exchanger. This new heat exchanger works with an actual counterflow exposure of more than 80 %, and at only 50 Pa pressure drop. At the same time, its performance places it in top energy efficiency classes and assures compliance with Ecodesign Directive 5/04. Menerga solutions with Adconair heat recovery are highly versatile and can be used in a great number and variety of applications. THE ADCONAIR HEAT RECOVERY SYSTEM IS AVAILABLE IN VARIOUS MODELS: Integrated, indirect adiabatic evaporative cooling Adiabatic Pro Adiabatic zerogwp AdiabaticDX carbonfree Compression refrigeration s also as reversible compression refrigeration s Operational modes Adiabatic operation mode in winter and filling s Free cooling *Without low-pressure hot water (LPHW) Offices, Sanitary, Test Adconair Adiabatic Cooling Controls Adiabatic cooling efficiency of 90 % No additional air-side pressure drop resulting from components installed in the air path, e.g. humidifiers Reduction of the required DX cooling duty by up to 70 % Maximum efficiency with minimal air-side pressure drop Use of polypropylene, which is microbiologically harmless and non-corroding Extremely long-lasting thanks to use of nonaging material Pressure stability for pressure differences up to 0,000 Pa between the two air flows Performance data of the cross-counterflow heat exchanger measured by TÜV NORD (German official technical inspection agencies) in actual installation situation and in accordance with EN08 Can be used in almost every application In-house production of all heat-exchange s Over 5 years of experience in producing heat recovery s made of polypropylene 4 4 the Individual control of heat recovery Remote maintenance via 56-bit encrypted cooling C-Bus, with interference-immune DX cooling (optional) Performance increase of the integrated DX cooling by up to 5 % by means of refrigerant sub-coolers Microchannel condensers, which enable reduction of refrigerant amount (up to 65 % less) and low air-side pressure drop (up to 40 % less) EER values of up to by combining the adiabatic cooling and DX cooling Low mains power consumption, and no peak power consumption during summer operation Point-perfect power control for great precision Various performance levels for optimally balanced s 4 Adconair overview 07/06/EN Subject to technical modifications. Menerga GmbH www.menerga.com 5

ADIABATIC EVAPORATIVE COOLING With Adconair heat recovery in the Adiabatic Pro version, Menerga has developed a technology to significantly optimize adiabatic evaporative cooling. This development is based on advances that include pre-cooling the extracted air upstream of the heat exchanger, which means increase of the overall efficiency of the cooling process to almost 00 %. Pre-cooling is used to lower the supply air temperature to 8 C and to simultaneously increase cooling capacity by up to 0 % (based on average room temperature of 6 C). Adconair heat recovery in the Adiabatic Pro version is a full-fledged, energy-saving alternative to conventional air conditioning s entirely without a refrigeration. FUNCTIONAL PRINCIPLE The Adconair Adiabatic Pro cools the outside air three times. In the extracted air, sensible pre-cooling takes place using a cooling coil. The cooling water comes from the internal circuit in the indirect, adiabatic evaporative cooling, located in the area of the extracted/supply air in the heat exchanger. This cooling water is sprayed in through an additional nozzle into the area of the exhaust air in the heat exchanger. This enables indirect evaporative cooling and, in turn, the third stage of outdoor air cooling. Operational mode Summer mode Adconair Adiabatic Pro Cooling Adiabatic cooling efficiency of 00 % High output, even with especially high internal thermal loads No need for a conventional refrigeration Controls the Individual control of heat recovery Remote maintenance via 56-bit encrypted cooling C-Bus, with interference-immune and filling s Offices, Sanitary, Test Maximum efficiency with minimal air-side pressure drop Use of polypropylene, which is microbiologically harmless and non-corroding Extremely long-lasting thanks to use of nonaging material Pressure stability for pressure differences up to 0,000 Pa between the two air flows Performance data of the cross-counterflow heat exchanger measured by TÜV NORD (German official technical inspection agencies) in actual installation situation and in accordance with EN08 Application in virtually all areas of use In-house production of all heat-exchange s Over 5 years of experience in producing heat recovery s made of polypropylene 6 Adconair overview 07/06/EN Subject to technical modifications. Menerga GmbH www.menerga.com 7

FLUOUROCARBON-FREE SUPPLY AIR COOLING It is possible to provide sufficient cooling without compression refrigeration s that use FC: as proven by the new climate-neutral cooling technology offered by Adconair Adiabatic zerogwp. This cools summery warm outside air to 8 C by a hybrid evaporative cooling. By combination of the technologies of indirect adiabatic evaporative cooling with dewpoint cooling inside the proven Adconair heat recovery, it is likewise possible to discharge high thermal and humidity loads outside the air conditioned rooms and to assure constant low supply air temperatures. FUNCTIONAL PRINCIPLE Within the first-half section of the heat exchanger, indirect, adiabatic evaporation cooling takes place, as familiar iar from Adconair Adiabatic and Adiabatic Pro s. Outside air is therefore already extensively cooled upstream. In the second-half section of the heat exchanger, so-called dew point cooling takes place. For this purpose, part of the already pre-cooled outdoor air is withdrawn after its exit from the heat exchanger as process air flow. Then it is directed back to the heat exchanger in accordance with the counterflow principle and again humidified. In this way, repeated indirect evaporative cooling takes place. Unlike conventional s, the lowest possible temperature is no longer dependent on the wet-bulb temperature of the extracted air, but rather on the wet-bulb temperature of the pre-cooled outside air. The process air flow is approximately 50 % of the nominal flow and is controlled continuously such that constant supply air temperature is maintained. When dimensioning on-site duct networks, consideration of this arrangement is necessary, since the outdoor and exhaust air ducts must be planned accordingly. Operational mode Summer mode Adconair Adiabatic zerogwp Cooling Controls Adiabatic cooling efficiency of 00 % (based on the wet-bulb temperature of the extracted air) Great output, even with especially high internal thermal loads Cooling of the outdoor air by up to 6 K possible No need for a conventional refrigeration the Individual control of heat recovery Remote maintenance via 56-bit encrypted cooling C-Bus, with interference-immune Maximum efficiency with minimal air-side pressure drop Use of polypropylene, which is microbiologically harmless and non-corroding Extremely long-lasting thanks to use of nonaging material Pressure stability for pressure differences up to 0,000 Pa between the two air flows Performance data of the cross-counterflow heat exchanger measured by TÜV NORD (German official technical inspection agencies) in actual installation situation and in accordance with EN08 Application in virtually all areas of use In-house production of all heat-exchange s Over 5 years of experience in producing heat recovery s made of polypropylene and filling s Offices, Sanitary, Test 8 Adconair overview 07/06/EN Subject to technical modifications. Menerga GmbH www.menerga.com 9

THERMALLY DRIVEN FLUOUROCARBON-FREE AIR CONDITIONING The new thermally driven air conditioning technology in the AdiabaticDX carbonfree version installed inside the proven Adconair heat recovery prevents high electrical power consumption during the summer cooling season. The cooling supply is provided by a closed adsorption cooling circuit integrated into the HVAC unit which supplies the heating coil, used for supply air heating in winter, with cold water for cooling. In contrast to a compression refrigeration, no electric power is needed for this operation, since heat at a temperature e level beginning at 60 C is employed. This heat is provided by connection of the heating supply, needed in any case for winter operation. Even in midsummer, the integrated return cooling by the adsorption refrigeration unit guarantees extremely low recooling temperatures and therefore allows high cooling energy efficiency ratios (EER). The water refrigerant, R78, integrated into the adsorption refrigeration unit has a Global Warming Potential (GWP) of zero. Unlike other natural refrigerants, it is neither flammable nor toxic. 4 FUNCTIONAL PRINCIPLE The key components of this consist of two modules, which are equipped with silica gel as an adsorption material. The physical process of adsorption produces cold water, which is used in a combi-coil to cool and dehumidify the supply air. The flow temperatures from the refrigeration circuit are low enough to cool the outside air from to around 6 C, in combination with indirect, adiabatic evaporative cooling. While one module generates the cold water by this process, the second module is regenerated during the same process. For this purpose, hot water (from 60 C) is applied, which leads to desorption of the saturated silica gel. The desorption is at least as fast as the adsorption, so that enough cold energy is always available. Operational mode Summer mode Adconair AdiabaticDX carbonfree FC-free supply air cooling Carbon-free, since water is used as refrigerant (GWP = 0) No additional energy consumption for supply air cooling and dehumidifying Operating power from 60 to 90 C Possible energy sources: solar heat, district heating, process heat, or the heating connection for the air heater, required in any case for winter operation Integrated re-cooling, therefore no external re-cooling plant required No additional heat exchanger in the supply air, therefore no additional, permanent pressure drops Cooling Adiabatic cooling efficiency of 90 % No additional air-side pressure drop resulting from components installed in the air path, e.g. humidifiers Reduction of the required DX cooling duty by up to 70 % and filling s Offices, Sanitary, Test Maximum efficiency with minimal air-side pressure drop Use of polypropylene, which is microbiologically harmless and non-corroding Extremely long-lasting thanks to use of nonaging material Pressure stability for pressure differences up to 0,000 Pa between the two air flows Performance data of the cross-counterflow heat exchanger measured by TÜV NORD (German official technical inspection agencies) in actual installation situation and in accordance with EN08 Application in virtually all areas of use In-house production of all heat-exchange s Over 5 years of experience in producing heat recovery s made of polypropylene 4 Controls the Individual control of heat recovery Remote maintenance via 56-bit encrypted cooling C-Bus, with interference-immune 0 Adconair overview 07/06/EN Subject to technical modifications. Menerga GmbH www.menerga.com

Creating a good indoor climate since 980. Worldwide. Menerga GmbH Alexanderstr. 69 Mülheim an der Ruhr Germany www.menerga.com info@menerga.com Find your sales office at www.menerga.com Keep up to date: the latest news and new products at www.menerga.com