L234 test report compliance to EN 12469

Similar documents
Safely Using a Centrifuge Near a Biological Safety Cabinet in Your Cell Culture Laboratory

Standard Operating Procedure M.I.C.E.

LABORATORY CABINETS 103

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

2 Microbiological Safety Cabinet

IVF/ART Series Laminar Flow Cabinets

5.0 Installation Instructions

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Gelaire BH-EN and UltraSafe cabinets

PART III. Laboratory equipment

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Environmental Health and Safety Biological Safety Program Guidance Document

Maximum protection for your health and well-being

Class II ECO Generation 8 Microbiological Safety Cabinet

OUR TRUSTED SERVICE & SUPPORT

AirGard. Air Flow Monitors

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

CONSTANT SUCTION UNIT

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Ergonomic and Green Class II s

BioMAT 2 Safety Cabinet

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Microbiological Safety Cabinets

Laminar Flow Cabinets eco air V

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

SpeedDigester K-425 / K-436 Technical data sheet

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Safe Use of a Class II Biological Safety Cabinet

SpeedDigester K-439 Technical data sheet

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

FSTC Equipment Test Report

Oil Mist Separator Unit LGA 600 FUW

Microbiological Safety Cabinets

Thermo Scientific 1300 Series A2

Vacuum drying VD VDL series

INCREASE YOUR LAB EFFICIENCY

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

Operation Manual. (Version 1.5.1)

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

Oil Mist Separator Unit LGA 600 FUW

Biological Safety Cabinets. Biological Safety Cabinets

The ultimate microbiological safety cabinet

Laboratory Automation & Robotic System Enclosures

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

for the next generation

Jun08 Rev A

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Quick Reference Guide to Cabinet types

Flexibility and individual design turn your dental unit into an active partner. Quality is not a consideration quality is the solution

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Safe Operating Procedure (Revised 2/10)

Installation Specifications Laundry Care System

STANDARD OPERATING PROCEDURES

Fortuna. Fortuna. »ScanLaf Probably the best in Class 1, Class 2 and Laminar flow technology.

HS Series Installation & Operating Instructions RadonAway

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Biological Safety Cabinet

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

FagronLab NP-1 UV. Negative pressure workbench. User Manual

INCREASE YOUR LAB EFFICIENCY

Control of Biological Hazards

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

CIRCULAIRE LAMINAR AIR FLOW

Microbiological Safety Cabinet

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Audit/Twinning Report

Requirements for Repair of a Miniature Liquid Helium-3 Refrigerator

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

IN020 Rev F Page 1 of 8

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

ASPIRE Laboratory Aspirator

Low Noise, Class II Biological Safety Cabinets The Safety Solution for Life Science Laboratories

EnvironmentalMonitoring

SOUND RECEPTION SYSTEM

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

Transcription:

20 460 234 age 1 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 Content 1 Scope... 3 2 Definitions and Acronyms... 3 3 How to obtain compliance to the Standard... 3 3.1 Type testing... 3 3.1.1 Retention at front aperture... 3 3.1.2 Leaktightness of carcass... 3 3.1.3 Filters... 4 3.1.4 roduct protection... 4 3.1.5 Cross contamination... 4 3.2 Installation testing... 4 3.2.1 Volumetric airflow rate measurements... 4 3.2.2 Check airflow patterns... 4 3.3 Guidance on manufacture... 4 3.3.1 Front aperture height... 4 3.3.2 Lightning... 4 3.3.3 Sound... 5 3.3.4 Vibration... 5 3.3.5 Stability... 5 3.3.6 Materials, general... 5 3.3.7 Glass and front window... 5 3.3.8 Electrical safety... 5 3.3.9 Gas supply safety... 6 3.3.10 Ergonomics... 6 3.3.11 Temparature... 6 4 Tests done... 6 5 erson... 6 6 Instrument / Series number / calibrated... 6 7 Conclusion... 7 8 Annex A... 8 9 Annex B... 9 9.1 Normal conditions... 9 9.2 If MSC is turned off after use... 9 10 Annex C... 10 11 Annex D... 12 age 2 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 1 Scope The scope of this document is to describe the compliance of the K-Systems L234 workstation to the standard EN 12469:2000. In general three types of performance testing can be distinguished: Type testing, Installation testing and routine maintenance testing. (See table 5 in EN 12469) Routine maintenance testing is a sub part of the installation testing as described in the standard. We have therefore chosen to verify that L234 comply type testing and relevant installation testing, as stated in table 5 in the standard. 2 Definitions and Acronyms 15 060 04 Definitions Testing is passed (). Not applicable (n/a). Testing is failed (F) 3 How to obtain compliance to the Standard The following paragraphs refers back to the test specifications listed in table 5 of the standard. See table 5 in annex D. 3.1 Type testing 3.1.1 Retention at front aperture KI method chosen and done testing. (See annex A) 3.1.2 Leaktightness of carcass Soap solution test method chosen and done testing. (See annex B) age 3 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 3.1.3 Filters Aerosol challenge method chosen and done testing. (See annex C) 3.1.4 roduct protection Microbiological method or alternative KI method. n/a 3.1.5 Cross contamination Microbiological method or alternative KI method. n/a 3.2 Installation testing 3.2.1 Volumetric airflow rate measurements Measurements must be made in the horizontal plane 50 mm to 100 mm above the top edge of the front aperture. Requirements in the standard states that the mean downflow velocity to achieve product protection must be within 0,25 m/s to 0,50 m/s. No individual measurements should differ from the mean by more than 20%. We measure mean 0,35 m/s. with a difference at min 9% and max 13% (See annex C). 3.2.2 Check airflow patterns Same as 3.2.1. (See annex C) 3.3 Guidance on manufacture 3.3.1 Front aperture height The height of the front aperture should be between 160 mm and 250 mm. We have 163,5 mm. 3.3.2 Lightning Lightning at the work surface should be at least 750 lux. age 4 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 We measure around 900 lux at the working positions. 3.3.3 Sound The sound level should not exceed 65 db A-weighted. We have measured 57 db A-weighted. 3.3.4 Vibration We have less than 0,005 mm RMS. At work surface between 20 Hz and 20000 Hz. 3.3.5 Stability Equipment is tilted in each direction to an angle of 10 from its normal position. Equipment has a force applied at its top, or at a height of 2 m if the equipment has a height more than 2 m. The force is 250 N, or 20 % of the weight of the equipment, whichever is less, and is applied in all directions except upwards. Conforming EN 61010-1 for stability. 3.3.6 Materials, general The material where micrio-organisms have contact whould be corrosion resistant, non-flammable and non-adsorbing. The tabletop where micro-organisms should be at is made of stainless steel, which is corrosion resistant, non-flammable and non-adsorbing. 3.3.7 Glass and front window Glass side windows complying to EN 61010-1. Transparent front window, can be taken off while system is not running, but must be mounted while in use. When working with IVF only a small opening is needed. 3.3.8 Electrical safety The MSC has been designed to, and are being tested at UL in Denmark, to conform EN 61010-1. In test age 5 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 3.3.9 Gas supply safety No flammable gas installed n/a 3.3.10 Ergonomics The design should ensure that maintenance can safety be carried out on the cabinet after installation. - Easy to remove back panel for filter replacement - Easy to open tray for cleaning - owder coated cabinet for easy cleaning - Stainless steel tabletop accept all normally use detergents and alcohol for cleaning 3.3.11 Temparature With no heat in tabletop temperature will not rise by more than 8 C. 4 Tests done - Downflow measurements - Inflow measurements - DO (HEA filter leakage) - KI-Discus 5 erson Mechanical Engineer Thomas Grau-Andersen 6 Instrument / Series number / calibrated - Testo 425 / 02052833 / 01-08-2012 - TDA-2G / 15747 / 03-09-2012 - Ki-Discus MK2 / K03/05-0188 / 22-08-2012 age 6 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 7 Conclusion Relevant tests from EN 12469:2000 is listed and show how L234 workstation comply to the class II standard. L234 workstation have successful ergonomics and the design ensure that maintenance can safety be carried out on the cabinet after installation. erformance results in brief: All airflow measurements such as downflow and inflow are complying to EN 12469:2000. DO test (HEA filter test) are complying to EN 12469:2000. The sound level are complying to EN 12469:2000. The vibration level are complying to EN 12469:2000. General design are complying to EN 12469:2000. age 7 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 8 Annex A The KI Discus test was performed: By: Thomas Grau-Andersen Date: 27-08-2012 On L234 S/N: roto 2 Instrumentation / calibration: Ki-Discus MK2 / 22-08-2012 The photo above shows the 4 filters suction in front of the cabinet, at the KI-Discus setup. Conclusion: We have less than 62 brown dots at each filter. age 8 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 9 Annex B 9.1 Normal conditions Under normal running conditions non-filtered air under positive pressure is encapsulated by surroundings negative pressure. Therefore positive pressure leaking to the surroundings under running conditions is only theoretical possible through sample port for DO testing. This sample port is double secured with both a valve and a silicone cap. 9.2 If MSC is turned off after use Soap solution test with an internal pressure at approximately 250 a and observe the soap applied. age 9 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 The Soap solution test was performed: By: Thomas Grau-Andersen Date: 20-08-2012 On L234 S/N: roto 2 Instrumentation: Soap solution The previous photos shows how soap solution is added to the cabinet. Conclusion: If the MSC is turned off nothing indicating leaks. 10 Annex C Downflow is measured by use of an anemometer. With the anemometer inside the MSC, make air velocity measurements in the horizontal plane 50 mm to 100 mm above the top edge of the front aperture. Make measurements over a period of at least 1 min in each position for at least eight positions. The exact height and placement can be seen in the tables(s) below. Inflow is measured by use of an anemometer. With the anemometer outside the MSC, make air velocity measurements pointing towards front opening. The exact height and placement can be seen in the tables(s) below. DO test (HEA filter test) is measured by use of an aerosol photometer. With this device test filters and edges along workspace filter and exhaust filter. If an aerosol photometer is used, the local penetration of a HEA filter should be not more than 0,01 %. Test results can be seen in the tables(s) below. age 10 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 age 11 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx

20 460 234 11 Annex D age 12 of 12 K:\UDVIKLING INF\rojekter\rojekt 55 L200 opdatering\analyse\l234 test report compliance to EN 12469.docx