SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

Similar documents
SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

WATER POWERED OSCILLATING MONITOR

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

mechanical. OPERATION Rapidrop Global

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

TECHNICAL DATA OBSOLETE

TOTALPAC2 Integrated Fire Protection System

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Deluge & Preac tion Systems

BERMAD Fire Protection

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

TotalPac X Single interlock SUREFIRE system

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TotalPac X Firecycle III Preaction Double interlock system

Instructions for Installation, Operation, Care and Maintenance

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

Technical Data. Installation

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

TotalPac 3 Firecyle III Deluge Remote controlled system

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Worldwide Contacts.

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

INSTALLATION, OPERATION AND MAINTENANCE

INSTRUCTION MANUAL HS-229G

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac 3 Wet pipe system c/w retard chamber

TITAN FLOW CONTROL, INC.

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Design Criteria. Installation

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

The Series LFII (TY3596) Residential

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

OPERATION & INSTALLATION MANUAL

Document No

DIVISION 21 FIRE SUPPRESSION

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Model DDX Deluge Valve

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

OWNERS MANUAL MODEL 451 (-101 & -201)

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

M Series Fan Filter Units

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Model/Sprinkler Identification Numbers

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

CONSTRUCTION REQUIREMENTS

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Sound Cover [ , , , ]

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

USER S OPERATING AND INSTRUCTION MANUAL

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Comfort Series Instant Hot Water System

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Model 9201EFE Tempered Water Blending System

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Instruction Manual Hydraulic Crimping Tool

SYSTEM CONTROL KIT Model: CK-41P

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Transcription:

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION HD FIRE PROTECT TECHNICAL DATA SIZE DELUGE VALVE CHECK VALVE SPRINKLER ALARM RELEASE PANEL 50, 80, 100, 150 & 200 NB Model H3, UL Listed Model-CH UL Listed (Optional) UL Listed (Optional) WATER FLOW UL Listed SWITCH SOLENOID VALVE 24V DC, UL Listed AUTOMATIC AIR Oil-less Risermount SUPERVISOR Compressor (Optional) AIR PRESSURE PMD-1 (Optional) MAINTENANCE DEVICE MANUAL SYSTEM UL Listed, Butterfly Valve - SHUTOFF VALVE Standard supply. (Gate Valve - Optional) MAXIMUM WORKING 17.5 Kg./sq.cm. (250 PSI) PRESSURE SYSTEM END Grooved (Standard supply) CONNECTION Flanged (Optional supply) APPROVAL UL Listed DESCRIPTION The Single Interlock Supervised Preaction System with Wet Pilot Actuation is generally used to protect water sensitive areas such as computer rooms, storage areas of valuable articles, to avoid water damage due to damaged sprinklers or damaged sprinkler piping. Preaction System is also effectively used to have Pre-alarm of a possible fire condition and allows time to extinguish fire by hand held fire extinguishing equipment, prior to water discharge through sprinkler heads. It uses an automatic sprinkler with supplemental detection system. In the event when fire cannot be extinguished by hand held fire extinguishing equipment, the increase in temperature will open one or more sprinkler heads to discharge water. In normal condition, preaction system does not contain water in the sprinkler piping. The sprinkler piping contains air pressure for the purpose of supervising its leak tightness. As per NFPA, the preaction system employing more than 20 automatic sprinklers is to have the sprinkler piping automatically supervised. The wet pilot system in single interlock preaction system will respond to a fire faster than the automatic sprinkler. The system designer selects the detection components for single interlock preaction system to detect the fire faster than automatic sprinkler. When fire is detected through wet pilot sprinkler system, the primary water control deluge valve opens, allowing water flow into the sprinkler piping in readiness for possible subsequent opening of one or more sprinklers. SYSTEM OPERATION The Single Interlock Supervised Preaction System with Wet Pilot Actuation utilizes automatic sprinklers and an additional wet pilot detection sprinkler system. The wet pilot sprinkler system operates faster than the automatic sprinkler system due to rise in temperature, by this the wet pilot pressure drops and deluge valve and actuate fire alarm devices. The sprinkler system also operates due to fire condition, then water flows through the sprinkler system. The water flow will also produce water pressure in the alarm trim of deluge valve. This may actuate the pressure switch if additionally provided to control the shut down of equipment such as computers or start up of the second alarm devices. In normal condition the integrity of system is automatically supervised by the automatic air supervisory means. Air or nitrogen at 0.7 ± 0.14 Kg./Sq.Cm. (10 ± 2 PSI) pressure is maintained in the sprinkler system up to the downstream of the riser check valve. The supervisory low alarm switch is set at 0.42 ± 0.07 Kg/Sq.Cm. (6 ± 1 PSI). The decreasing pressure will give trouble annunciation due to the loss of pressure, due to abnormal leakage in the sprinkler system piping as a result of the damaged sprinkler or broken pipeline. This will not open the deluge valve. The air pressure is for supervisory alarm only. The automatic supervisory air supply can be maintained through factory set air compressor. JANUARY, 2018 PAGE 1 OF 6

The compressor is compact and can be riser mounted or floor mounted. The supervisory air can be maintained with the tank mounted compressor and air maintenance device. If continuous plaint air supply or regulated Nitrogen source is available, then air maintenance device shall be used to maintain the supervisory air supply. The major benefits of this system as compared to the dry pipe system are, a) A fire alarm sounds prior to operation of a sprinkler, which may enable to extinguishing of the fire by hand held means, before operation of any sprinkler head. This can eliminate water damage. b) Whenever integrity of the piping or sprinkler is disturbed, no water flows, only trouble annunciation alarm signals. This will avoid water damage to valuable property. c) Early fire alarm is provided by electric detection system, without the delay of water delivery time. INSTALLATION & COMMISSIONING The preaction system valves, panel, indicators must be installed in a readily visible and accessible location. The system valves and accessory shall not be installed in an area having temperature less than 4 o C (40 o F). Heat tracing to system valve and accessory is not permissible. The system must be installed and operated carefully by a trained person, having good knowledge of equipment. All system piping must be flushed thoroughly before commissioning. After initial successful tests, an authorized person must be trained to perform inspection, testing and maintenance of the system. RECOMMENDED SEQUENCE OF INSTALLATIONS 1. Install the Deluge Valve on Riser. 2. Install the Riser Check Valve above Deluge Valve as shown in installation drawing. 3. On completion of system piping, install all the trims as per trim drawing. Care must be taken to ensure that Check Valves, Strainers, Valves etc. are installed with the flow arrows in proper direction. 4. Connect all drain piping as shown in the drawing. 5. All unused opening on valve or trim parts must be plugged. 6. Connect air supply line. 7. Connect all electrical to control panel as per wiring drawing. 8. Make sure that all the nut bolts, fittings are screwed properly. 9. Follow the valve resetting and test procedure. RESETTING PROCEDURE a. Close the upstream side stop valve of the Deluge Valve. b. Open drain valves and allow water to drain (if water flow was establish) & close drain valve when water flow has ceased. c. Check all release devices are closed. Inspect the release devices if system was subject to fire condition. d. Open the priming line so that the diaphragm chamber reads the system water pressure. Open the manual release station partly to vent the air & then close it. e. Open the upstream side of stop valve to read the Deluge Valve Inlet water supply pressure. The Deluge Valve is set. f. Open the air supply line and check the pressure is maintained up to 0.7 Kg./Sq.Cm. (10 PSI) and Control Panel is kept on. h. Check all the trim parts for possible leak. INSPECTION AND MAINTENANCE Inspection and testing is to be carried out only by an authorized and trained personnel. DO NOT TURN OFF the water supply or close any valve to make repair(s) or test the valve, without placing a roving fire patrol in the area covered by the system. Also inform the local security personal and central alarm station, so that there is no false alarm signal. It is recommended to carry out physical inspection of the system at least twice a week. The inspection should verify that no damage has taken place to any components and check for following normal condition of the system. NORMAL CONDITION a. All main valves are open and sealed with tamper proof seal. b. All drain valves are in closed condition. c. No leak or drip is detected from drip valve. d. All water gauge of deluge valve, should show the required pressure. e. No leak in any trim or other piping. f. Release panel is on and no abnormal indication are seen. g. All testing procedure to be verified at Jalgaon. JANUARY, 2018 PAGE 2 OF 6

CAUTION Procedure outlined below will result in operation of associated alarm. Concerned authorities to be informed about the tests before conducting the tests. QUATERLY TEST WATER FLOW ALARM TEST Open the sprinkler alarm gong test valve, the water will flow through sprinkler alarm and/or water flow switch. On satisafctory observation close the alarm test valve. CAUTION The system must be inspected, tested and maintained as instructed above, in addition to the requirement of NFPA or as per requirement of authority having jurisdiction. The owner is responsible for the inspection, testing and maintenance of the system and devices. AIR SUPPERVISORY LOW PRESSURE ALARM Release air pressure gradually through valve provided on check valve. When air pressure drops to 0.42 ± 0.07 Kg./Sq.Cm. (6 PSI ± 1), the supervisory low pressure alarm must be observed. Close the valve and observe that air pressure has been established to 0.7 ± 0.14 Kg. / Sq. Cm. (10 ± 2 PSI), the supervisory air pressure alarm must come to normal condition. If required reset the release panel. ANNUAL OPERATION TEST Testing valve operation without causing water upply to the deluge valve. a. Close the main system valve controlling water supply to the deluge valve. b. Open the main drain valve provided on deluge inlet side and allow water to drain. When water flow from drain valve has stopped crack open the main system valve and close the main drain valve partly allowing the water pressure at inlet of deluge valve to raise up to 1.4 Kg. / Sq. Cm.(20 PSI) and no more pressure is rising. c. Operate emergency release station; Deluge valve must open and water flow must be noticed through drip valve and the fire alarm bell should sound. Close the main supply control valve immediately and allow water to drain from drain valve. d. When water flow has stopped, reset the deluge valve as per resetting procedure. CAUTION The steps b & c must be performed very quickly to prevent water flow to riser. NOTE: For abnormal condition of deluge valve refer the data sheet No. HD235. JANUARY, 2018 PAGE 3 OF 6

HD FIRE PROTECT SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION SCHEMATIC DIAGRAM 15 14 12 10 9 8 4 13 7 11 3 12 2 6 1 5 16 FRONT VIEW 10 14 15 4 12 7 13 11 4 16 2 1 REAR VIEW JANUARY, 2018 PAGE 4 OF 6

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION PART LIST PREACTION TRIM SIZE QUANTITY PER PREACTION TRIM ITEM NO CODE NO DESCRIPTION SIZE/ MAKE 200 NB 150 NB 100 NB 80 NB 50 NB 1 BFV WAFER TYPE GEAR OPRT. 2, HD MAKE WITH TAMPER SWITCH * (MODEL NO.HDMW300) 1 1 1 1 1 2 6458 DELUGE VALVE FLANGE END 2, HD MAKE (MODEL NO.DV-H3) - - - - 1 2 6455 DELUGE VALVE FLANGE END 3, HD MAKE (MODEL NO.DV-H3) - - - 1-2 6454 DELUGE VALVE FLANGE END 4, HD MAKE (MODEL NO.DV-H3) - - 1 - - 2 6453 DELUGE VALVE FLANGE END 6, HD MAKE (MODEL NO.DV-H3) - 1 - - - 2 6457 DELUGE VALVE FLANGE END 8, HD MAKE (MODEL NO.DV-H3) 1 - - - - 3 1951 EMERGENCY RELEASE STATION 1/2, HD MAKE (MODEL ERS-1) 1 1 1 1 1 4 9392 ANGLE VALVE 1-1/4 - - - 1 1 4 9394 ANGLE VALVE 2 1 1 1 - - 5 9423 PRIMING VALVE 1/2 1 1 1 1 1 6 RESTRICTED CHECK VALVE 1/2 1 1 1 1 1 7 1825 ANTI RESET VALVE (ARV-1) 1/2 1 1 1 1 1 8 3569 CHECK VALVE - FLANGE TO GROOVE 2, HD MAKE (MODEL NO. CH) - - - - 1 8 114345 CHECK VALVE - FLANGE TO GROOVE 3, HD MAKE (MODEL NO. CH) - - - 1-8 114346 CHECK VALVE - FLANGE TO GROOVE 4, HD MAKE (MODEL NO. CH) - - 1 - - 8 114343 CHECK VALVE - FLANGE TO GROOVE 6, HD MAKE (MODEL NO. CH) - 1 - - - 8 114347 CHECK VALVE - FLANGE TO GROOVE 8, HD MAKE (MODEL NO. CH) 1 - - - - 9 1674 PRESSURE MAINTENANCE DEVICE* 1/2 (PMD-1) 1 1 1 1 1 10 114071 PRESSURE GAUGE 0-300 PSI, UL LISTED 1 1 1 1 1 11 1416 SPRINKLER ALARM (GONG BELL)* HD MAKE (TYPE-A) 1 1 1 1 1 12 PRESSURE SWITCH POTTER MAKE, UL LISTED 1 1 1 1 1 13 TRIM FITTINGS 1 1 1 1 1 14 AUTOMATIC SPRINKLER ** 1 1 1 1 1 15 WET PILOT LINE SPRINKLER 1 1 1 1 1 16 SPLASH PROOF FUNNEL 1 1 1 1 1 * OPTIONAL SUPPLLY ** NOT SUPPLLIED BY HD FIRE NOTES: DELUGE VALVE END CONNECTION (OPTIONAL - G X G/ F X F) CHECK VALVE END CONNECTION (OPTIONAL - G X G/ F X G / F X F) BUTTERFLY VALVE END CONNECTION (OPTIONAL - G X G/ WAFER TYPE / LUG TYPE) PRESSURE GAUGE (OPTIONAL - HDP-1 / HDP-2) OPTIONAL TRIM SUPPLY - LOOSE / SEMI ASSEMBLED) SHAPE OF FITTINGS / VALVES MAY CHANGE. SYSTEM PIPING, SPRINKLER, DETECTOR NOT SUPPLIED BY HD FIRE PRIMING LINE BY OTHERS F = FLANGE END G = GROOVE END JANUARY, 2018 PAGE 5 OF 6

ORDERING INFORMATION X XX X X X Size Actuation Device Air Maintenance Device Control Panel Compressor 1 50 2 65 3 80 4 100 5 150 6 200 SW Single Intelock Supervised Preaction with Wet Pilot Actuation N None 1 PMD-1 2 Nitrogen Air Maintenance Device N A None Included N None 1 1/6 HP 2 1/3 HP 3 1/2 HP 4 3/4 HP 5 1 HP 6 1-1/2 HP LIMITED WARRANTY HD FIRE PROTECT hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer s warranty. No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer s representatives. HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire s product liability exceed an amount equal to the sale price. The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us is to the best of our knowledge and belief, and consist of general guidelines only. Site handling and installation control is not in our scope. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of HD FIRE PROTECT and hence the right to modify any specification without prior notice is reserved with the company. HD FIRE PROTECT Protecting What Matters Most to You D-6/2, ROAD NO. 34, WAGLE INDUSTRIAL ESTATE, THANE 400 604, INDIA. TEL: + (91) 22 2158 2600 FAX: +(91) 22 2158 2602 EMAIL: info@hdfire.com WEB: www.hdfire.com JANUARY, 2018 PAGE 6 OF 6