SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

Similar documents
SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

FagronLab NP-1 UV. Negative pressure workbench. User Manual

UV I UNIT030W / UV I UNIT055W

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

April, Solid State LED Based Lighting: High Power UV Light Sources for Industrial Applications

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Medical Refrigerator

UV measurements for medical applications using SiC photodiodes

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

DUQUESNE UNIVERSITY. Laser Safety Program

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Corporate Overview. April

PCR UV cabinets DNA/RNA

Medical Refrigerator DW-25H SERIES

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

UVC/T-M-AR stainless steel UV cabinet

Non Ionizing Radiation Audit checklist

PCR UV cabinets DNA/RNA

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

Instruction Manual E4 ChamberIR Heater

Testing Emission Source ITES Operating Manual OM

Radiation and Laser Safety

BiliCare INTENSIVE PHOTOTHERAPY

BIO-SPECTRUM TREATMENT DEVICE

User manual UV Flash Dry C1

UV Weather Resistance Test Chamber Technical Data

PURPOSE OF THE PROCEDURE

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

YS-B501 SPA Deluxe Overall Functional Capsule

NO4G, NO4GS, NO6G, NO6GS

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

Development of a variable output LED-365 irradiance standard

WZ-T8-W18 T8 LED Tube Light

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

GERMICIDAL ULTRAVIOLET FIXTURES

700 Watt LED GROW LIGHT

A measured step forward

Infrared Moisture Balance (FD-660)

Heat Management Methodology

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

AEM EASY DRUM M A N U A L

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Efficient curing processes with innovative UV-LED technology The Heraeus Noblelight UV-LED portfolio

Recommended Work Area Controls

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

Mercury Vapor Monitor VM-3000

Medical Lasers and Laser Safety

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Laser & Ultraviolet Light Sources Safety

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Flame Simulator User Manual. Publication Rev. A

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

INSTALLATION & MAINTENANCE

Intensive UV light means not a chance for germs!

VM-3000 Mercury Vapor Monitor

Bernd Eichler Sales Manager

North Dakota State University Laser Safety

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

Document No C Revised January Atlantic Ultraviolet Corporation

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

T8 LED LIGHTING TUBE (LUX V.)

USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

Document No A9 Revised August Atlantic Ultraviolet Corporation

UV Irreversible Indicators Product Code: UVI-001

Model CWA200 Owner s Manual

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

VM-3000 Mercury Vapor Monitor

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2

Benefit from our experience and competence Application-focused solutions from UV to IR

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Digital Sensors Erythema Sensor PMA2101

Light fright. Improper laser use poses real safety hazards

ULTRAVIOLET PORTABLE AREA SANITIZER

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Electro Optical Components, Inc Skylane Boulevard, Suite D, Santa Rosa, CA Toll Free: 855-EOC

Document No A3 Revised February Atlantic Ultraviolet Corporation

Metal, ceramic, plastic package products

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Prizmatix UV Torch. User Manual

LED Dusk to Down Fixture

EL400 OPERATION MANUAL

Ultraviolet Air Disinfection Equipment

Environmental Chambers

The incredible power of light Photonics-based solutions from ultraviolet to infrared

Model KBWF 720 Growth chambers with light and humidity

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Transcription:

UV LED SPOT CURING SYSTEM ADD:, No. 2 of Qinglong Rd, Longhua, Shenzhen, 518109, China TEL: +86 755 27528108 FAX: +86 755 29641518 WEBSITE: www.szlamplic.com EMAIL: szlamplic@hotmail.com

ADVANTAGES 1). Environment-friendly: No Mercury, No ozone 2). No infrared light, No heat radiation, Normal temperature 3). Long Life: 20000+ hours for advanced LED radiation head 4). Instant ON&OFF, don t need preheating 5). Low cost: don t need to change lamp, save 80% of energy OPTIONAL WAVELENGTH Far UV: 240, 245, 250, 255, 260, 265, 270, 275, 280, 285, 290, 295 nm Near UV: 300, 305, 310, 315, 325, 335, 345, 355, 365, 385, 395, 405, 415 nm Visible light: 420, 430, 450, 470, 490, 500, 505, 525, 535, 545, 565, 570, 580, 590, 605, 625, 630, 645, 660, 670, 680, 690, 700, 720, 735, 750, 760, 780 nm Spectrum bandwidth: ± 5 nm UV LED SPECTRUM UV LED LIGHT DECAY

UV LED SPOT LIGHT GUIDE (1) Fan cooling: excellent heat dissipation performance, suitable for continuous radiation for long time. (2) Natural cooling: No vibration, suitable for using in small space or clean room, not suitable for long time continuous radiation LED Spot Intensity Cooling Facular Focal Head Model Picture & Dimension for 365nm Method Diameter Distance NO. (mw/cm2) LHFC084-03 Φ3mm 9mm 10000 LHFC084-04 Φ4mm 10mm 9000 LHFC084-06 Fan Φ6mm 17mm 4000 LHFC084-08 Cooling Φ8mm 20mm 2300 LHFC084-10 L88mm or L188mm Fan:24*24*24mm Φ10mm 25mm 1100 LHFC084-12 Φ12mm 30mm 800 LHS049-03 Φ3mm 9mm 10000 LHS049-04 Φ4mm 10mm 9000 LHS049-06 LHS049-08 Natural Cooling Φ6mm Φ8mm 17mm 20mm 4000 2300 L66mm LHS049-10 Φ10mm 25mm 1100 LHS049-12 Φ12mm 30mm 800 LHS118-03 Φ3mm 9mm 10000 LHS118-04 Φ4mm 10mm 9000 LHS118-06 LHS118-08 Natural Cooling Φ6mm Φ8mm 17mm 20mm 4000 2300 LHS118-10 L118mm Φ10mm 25mm 1100 LHS118-12 Φ12mm 30mm 800 Notes: Spot diameter means the uniform light diameter at the recommended distance

UV LED SPOT LIGHT GUIDE STRUCTURAL DRAWING UV LED SPOT SYSTEM S CONTROLLER

UVEC-4II UVEC-4IIController Model UVEC-4II Name UV LED curing heads QTY 1-4 PCS of Spot LED heads 1-2 PCS of linear/area LED heads Dimension for UVEC-4II 180L*100W*146H(mm) Dimension for UVEC-4III 156L*100W*163H (mm) Terminal I/O Input Foot pedal & serial RS-232 signals Output serial RS-232 communication signals Cooling method Semiconductor cooling Power setting 0 100% Time setting 0-999.99 S Radiation Mode Fixed power Step power Manual Constant power radiation Step power radiation Foot pedal control after setting Power supply voltage AC220V±15% ( 50/60HZ ) Environmental temperature 0 50 Environmental humidity MATERIAL ADDITIONAL 20% 80% RH ALUMINUM Operating Manual, Key, Cables, Power supply THE STRUCTURAL DRAWING OF UVEC-4II

Safety Instructions: Precautions described in the present note intended to illustrate the safe and proper use of the equipment, and to prevent the operator and others from hazards in advance. Read the following precautions to avoid unnecessary losses and damage. 1. Plug in the power, open the switch on the back of the controller, and then open the controller panel key lock. According to the control mode, select the panel button or foot switch to control the irradiation. 2. Supply voltage (100V-220V/60HZ-50HZ), power adapter input, DC12V 4A. 3. In the working process of this product, it is strictly prohibited to gaze the direct light, reflected light, or irradiate human skin directly or reflexly. 4. The operator must wear UV protective glasses and gloves and other protective UV protection tools; otherwise, it may cause inflammation of the eyes, skin, and etc. 5. Prohibited to disassemble, repair alteration the controller that may cause the device quality problems, accidents, personal injury. Keep the device body horizontally and correct used, not tilted, traversed or inverted to use; Otherwise, the equipment might be damaged and affect personal safety. 6. The device does not have a waterproof, need to be kept clean and dry. 7. Prohibited twist, disassemble irradiation head, so as not to affect the ultraviolet energy output and output quality. 8. Scrubbing equipment with dry paper towel lightly. 9. Not to touch UV irradiation head when the power on or power off shortly, so as not to burn human skin. 10. Do not let water and other liquid dripped or splashed on the device. 11. Keep away from the high-pressure machinery, power machinery, heating and heat source. 12. Do not put debris on the device and device-independent things. 13. Prohibited in the electrostatic places use the device to prevent electrostatic discharge. MAIN APPLICATIONS (1) UV light curing: optical equipment, optical communication products and crafts manufacturing, electronic components, hard drives, and micro-motor manufacturing, manufacturing headphones and watch parts, optical DVD / CD production. (2) UV detection and analysis instrument: UV analyzers, for bio-genetic engineering, molecular genetics, medical health, biological products, pharmaceutical research, sanitation and epidemic prevention, dyes chemical, petrochemical, textile industry, public security and judicial departments, cultural relics archaeological department, and wherever fluorescence analysis test is needed. (3) UV disinfection: it can be widely applied in various areas of need for water disinfection. (4) Biological applications: Sterilization, Plant physiology research, Seed quality research (5) Medicine and Medical Applications: Medical diagnosis and treatment: dental curing,

vitiligo treatment, Bio-pharmaceutical applications, In drug production and research