STORAGE TANKS NEWS WITH TRADITION

Similar documents
WATER HEATERS. Tradition from 1956

WATER HEATERS AND HOT WATER STORAGE TANKS

Storage Tanks Type NADO

WATER HEATERS AND HOT WATER STORAGE TANKS

Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

WATER HEATERS AND HOT WATER STORAGE TANKS

OPERATING AND INSTALLATION MANUAL

Stationary 1 MPa. INDIRECT stationary water heater OKC NTR

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING and INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

TANK TYPE INDIRECT WATER HEATERS

StorMaxx CTEC Series Tanks

OPERATING AND INSTALLATION MANUAL

Installation and Operating Manual

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

STORAGE WATER HEATERS

Knight & Charger Water Heaters

OPERATING AND INSTALLATION MANUAL

The world s most advanced direct electric water cylinder

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

INDIRECT SYSTEM FOR FROST LOCATIONS

OPERATING and INSTALLATION MANUAL

Page 1 SERVICE MANUAL. Little flow heaters SERVICE MANUAL

TERMO Combi Cylinder TECHNICAL INFORMATION

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

ECOplus Solar Cylinder

OPERATING AND INSTALLATION MANUAL

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

protective magnesium anode and hard polyurethane insulation. Socket for optional

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: MonoWave single-coil and DuoWave twin-coil unvented heat pump cylinders

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

OWL-E ,00 OWL-E ,90 OWL-E ,00 OWL-E ,50

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:


Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

Heating December 2008

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

England. SMART CABIN kw. Purity to Nature Savings to Clients Comfort to Users

General knowledge on the Energy labelling. LabelPackA+ Place, Date

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

INDIRECT WATER HEATERS

<< >> Condensing technology at the service of oil. Controlling energy to save money

Energy you can recycle

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

WATER HEATERS FOR CENTRAL UTILITY WATER ENSOL/1

Recommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

Water Heaters and. Storage Vessels. Indirect Water Heaters (mains water systems)

Smart temperature control solutions

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

Moor Heating Air Source Heat Pump Case Study

Your home heating since 1888

Compressors, Chillers & Condensers

Slide 1 Jul 20, 2006 Viessmann UK

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Harlequin HeatStream Case Study

News letter NOVEMBER /2018

BESA HIU test procedure. Martin Crane. Carbon Alternatives

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

solar thermic systems

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

THE HEART OF YOUR COMFORT

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Energy Efficient Product Policy in the European Union

Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:

White paper: New Ecodesign rules and energy labelling for space and water heaters

INTEC Engineering GmbH Energy systems

News letter J U N E /

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Apricus Residential Solar Hot Water Systems CLICK TO START

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

ROTEX gas hybrid heat pump. A strong team.

TABLE OF CONTENTS EKHTS-A

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Pro-Clean Stratified Tank scope of delivery:

GeyserWise MAX. Instruction manual. All in one hot water management

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Electric Water Heaters. The STRENGTHS of the product range in detail:

Smith s Environmental High Efficiency Handbook

IBA Hamburg International Building Exhibition Building the City Anew

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Transcription:

STORA TANKS NWS WT TRADTON

ontents Storage tank NAD v... Storage tank NAD v... Storage tank NAD v... Storage tank NAD v... 5 Storage tank NAD v5... 6 Storage tank NADO v... 7 Storage tank NADO v... 0 Storage tank NADO v... Storage tank NADO v6... Storage tank NADO v7... 5 Storage tank NADO v9... 7 Storage tank UKV N... 8 eat insulation of the utmost quality... 9 Original parts from Dražice... 0 ompany istory... egend to cons nlets Outlets Solid fuel boiler loor heating iomass boiler Radiator ireplace insert ot water lectric heating dry ceramic unit TPK 0/ lectric heating wet unit TJ 6/ eat pump Photothermic solar system Photovoltaic solar system Tolerance of all stated dimensions complies with ČSN SO Z/T circuit socket = socket of heating sources and heating circuits T V * The value is derived by calculation

R A TR 5 x Storage tank NAD v (types 00, 50) : : New product NAD 00 v Types: 00, 50 The tank is supplied with insulation Suitable as an equalization tank for heating systems with solid fuel boilers The TJ 6/" heating unit can be mounted into the socket Socket dimensions NAD 00v NAD 50v Socket " male thread " female thread Socket "TJ " female thread Socket " male thread " male thread Socket " female thread NAD 00v NAD 50v Technical parameters NAD 00v NAD 50v Order number 08800 09809 eating water volume in tank [l] 0 65 Weight [kg] 6 Max. operating temperature / pressure in tank [ ] / [bar] 90 / nsulation thickness (Polyurethane) [mm] eat conductivity of insulation (Polyurethane) [W m K ] 0,0 nsulation order number (Polyurethane) tank component Max. number output of TJ 6/" [ks] [kw] 6 nergy efficiency class (Polyurethane) Standing loss (Polyurethane) [W] 88 Tank dimensions NAD 00v NAD 50v Tank diameter with insulation D 58 58 Total tank height 807 570 Tilting height K 605 Tank height 5 Discharging connection A 6 Z/T circuit socket 576 8 Z/T circuit socket 0 88 Z/T circuit socket 556 08 Sensor pocket socket 8 Sensor pocket socket 95 Sensor pocket socket 08 lange socket J Spacing of user-type suspension R 00 0, 50 7, 68 k d D NAD 00v NAD 50v d D

A A J M Storage tank NAD v (types 500 000) : V : Types: 500, 750, 000 l Modern Neodul insulation can be ordered Suitable as an equalization tank for heating systems with solid fuel boilers The TPK 0/ heating unit can be mounted into the flange We can supply more custom made flanges for the tank The TJ 6/" heating unit can be mounted into the socket Socket dimensions NAD500v NAD750v NAD000v NAD500v NAD000v Socket female thr. Socket female thr. " " Socket male thr. " Socket female thr. " NAD 500, 750, 000v NAD 500v NAD 000v Technical parameters NAD 500v NAD 750v NAD 000v NAD 500v NAD 000v Order number 809 6809 5809 809 809 eating water volume in tank [l] 75 77 999 507 007 Weight [kg] 85 09 6 0 7 Max. operating temperature / pressure in tank [ ] / [bar] 90 / nsulation thickness (Neodul PP) [mm] 80 00 0 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 670 67 Max. number output of TPK 0- [ks] [kw] Max. number output of TJ 6/" [ks] [kw] 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 8 5 65 85 Tank dimensions NAD 500v NAD 750v NAD 000v NAD 500v NAD 000v Tank diameter d 600 750 850 00 00 Total tank height 97 0 05 906 6 Tilting height K 99 05 050 95 80 Tank height 86 895 905 778 07 Discharging connection A 00 90 90 5 5 Z/T circuit socket 70 7 9 50 50 Z/T circuit socket 958 960 980 90 75 Z/T circuit socket 65 66 666 70 000 Sensor pocket socket 505 508 57 600 600 Sensor pocket socket 555 80 90 Sensor pocket socket 97 556 576 895 60 lange socket J 5 6 lange socket M 50 50 k k 5 d 5 d 85 NAD 500, 750, 000v NAD 500, 000v

A A Storage tank NAD v : : Types: 500, 750, 000 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an equalization tank for heating systems with solid fuel boilers The TJ 6/" heating unit can be mounted into the socket Socket dimensions NAD500v NAD750v NAD000v NAD500v NAD000v Socket female thr. Socket female thr. " " Socket male thr. " Socket female thr. " NAD 500, 750, 000v NAD 500v NAD 000v Technical parameters NAD 500v NAD 750v NAD 000v NAD 500v NAD 000v Order number 809 6809 5809 809 809 eating water volume in tank [l] 75 77 999 507 007 Weight [kg] 76 0 9 5 Max. operating temperature / pressure in tank [ ] / [bar] 90 / nsulation thickness (Neodul PP) [mm] 80 00 0 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 6908 69 6909 67 67 Max. number output of TJ 6/" [ks] [kw] 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 8 5 65 85 Tank dimensions NAD 500v NAD 750v NAD 000v NAD 500v NAD 000v Tank diameter d 600 750 850 00 00 Total tank height 965 0 05 906 6 Tilting height K 985 05 050 95 80 Tank height 85 895 905 778 07 Discharging connection A 90 90 90 5 5 Z/T circuit and sensor pocket socket 58 7 9 65 65 Z/T circuit and sensor pocket socket 6 66 666 70 70 Sensor pocket socket 9 508 57 70 000 Sensor pocket socket 5 556 576 600 600 TJ 6/" heating unit socket 6 76 98 80 90 k k d NAD 500, 750, 000v d 85 NAD 500, 000v

A A Storage tank NAD v : V : Types: 00, 500, 750, 000 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an equalization tank for heating systems with solid fuel boilers The TPK 0/ heating unit can be mounted into the flange The TJ 6/" heating unit can be mounted into the socket Socket dimensions NAD 00v NAD 500v NAD 750v NAD 000v Socket female thread Socket female thread " " Socket male thread " NAD 500, 750, 000v NAD 00v Technical parameters NAD 00v NAD 500v NAD 750v NAD 000v Order number 08087 8087 68087 58087 eating water volume in tank [l] 0 75 77 999 Weight [kg] 60 87 0 6 Max. operating temperature / pressure in tank [ ] / [bar] 90 / nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 6900 69 6906 690 Max. number output of TPK 0- [ks] [kw] Max. number output of TJ 6/" [ks] [kw],75 + 9,75+ 9,5+ 9 6+ 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 80 8 5 Tank dimensions NAD 00v NAD 500v NAD 750v NAD 000v Tank diameter d 550 600 750 850 Total tank height 60 965 0 05 Tilting height K 60 985 05 050 Tank height 80 85 895 905 Z/T circuit and sensor pocket socket A 5 58 7 9 Z/T circuit and sensor pocket socket 760 78 7 750 Z/T circuit and sensor pocket socket 75 76 89 08 Z/T circuit and sensor pocket socket 6 66 666 lange socket 57 75 k k d NAD 00v 50 0 50 d 50 NAD 500, 750, 000v 0 50

A J M K Storage tank NAD v : T V : Types: 500, 750, 000 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an equalization tank for heating systems with solid fuel boilers The TJ 6/" heating unit can be mounted into the socket The TPK 0/ heating unit can be mounted into the flange Socket dimensions NAD 500v NAD 750v NAD 000v Socket female thread Socket female thread " " Socket male thread " Socket female thread " Technical parameters NAD 500v NAD 750v NAD 000v Order number 8095 68095 58095 eating water volume in tank [l] 75 77 999 Weight [kg] 0 5 9 Max. operating temperature / pressure in tank [ ] / [bar] 90 / eat transfer surface of exchanger [m ],5 xchanger volume [l] 0,5 Max. operating temperature / pressure in exchanger [ ] / [bar] 0 / 0 nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 Max. number output of TPK 0- [ks] [kw] 6 Max. number output of TJ 6/" [ks] [kw] 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 80 9 Tank dimensions NAD 500v NAD 750v NAD 000v Tank diameter d 600 750 850 Total tank height 965 0 05 Tilting height K 985 05 080 Tank height 85 895 905 Discharging connection A 90 90 90 Z/T circuit and sensor pocket socket 58 7 9 Z/T circuit and sensor pocket socket 96 960 980 Z/T circuit and sensor pocket socket 6 66 666 Sensor pocket socket 9 508 57 Sensor pocket socket 5 556 576 TJ 6/" heating unit socket 95 90 960 eat exchanger socket J 8 68 8 eat exchanger socket K 876 896 90 lange socket M 57 75 k x0 5 d 7 5

A O J K M N Storage tank NAD v5 : T V : Types: 500, 750, 000 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an equalization tank for heating systems with solid fuel boilers and solar systems The TJ 6/" heating unit can be mounted into the socket The TPK 0/ heating unit can be mounted into the socket Socket dimensions NAD 500v5 NAD 750v5 NAD 000v5 Socket female thread Socket female thread " " Socket male thread " Socket female thread " Technical parameters NAD 500v5 NAD 750v5 NAD 000v5 Order number 8086 68086 58086 eating water volume in tank [l] 75 77 999 Weight [kg] 8 56 7 Max. operating temperature / pressure in tank [ ] / [bar] 90 / eat transfer surface of exchanger (top/bottom) [m ],5 /,5 xchanger volume (top/bottom) [l] 0,5 / 0,5 Max. operating temperature/pressure in exchanger [ ] / [bar] 0 / 0 nsulation thickness (Neodul PP) [mm] 80 eatconductivityofinsulation(neodulpp) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 Max. number output of TPK 0- [ks] [kw] Max. number output of TJ 6/" [ks] [kw] 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 8 6 Tank dimensions NAD 500v5 NAD 750v5 NAD 000v5 Tank diameter d 600 750 850 Total tank height 965 0 05 Tilting height K 985 05 080 Tank height 85 895 905 Discharging connection A 90 90 90 Z/T circuit socket 58 7 9 Z/T circuit socket 96 960 980 Z/T circuit socket 6 66 666 Sensor pocket socket 9 508 57 Sensor pocket socket 5 556 576 TJ 6/" heating unit socket 95 90 960 ower heat exchanger socket J 8 68 8 ower heat exchanger socket K 876 896 90 Upper heat exchanger socket M 050 060 08 Upper heat exchanger socket N 578 590 6 lange socket O 57 75 k x0 5 6

A A x0 J Storage tank NADO v : V : Types: 500, 750, 000 l nner W storage tank in volumes of 0 and 00 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as a storage tank for heating systems with solid fuel boilers The TPK 0/ heating unit can be mounted into the flange The TJ 6/" heating unit can be mounted into the socket for 0 l version Socket dimensions NADO 500v NADO 750v NADO 000v Socket female thread Socket female thread " " Socket male thread " Socket female thread " Socket 5 female thread " NADO 500/00v NADO 500/0v Technical parameters NADO 500/0v NADO 750/0v NADO 000/0v NADO 500/00v NADO 750/00v NADO 000/00v Order number 805 6805 5805 8097 68097 58097 eating water volume in tank [l] 75 77 999 75 77 999 Volume of storage tank for W heating [l] 0 0 Weight [kg] 7 5 7 5 66 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temp. / pressure in W storage tank [ ] / [bar] 90 / 6 eat transfer surface of W storage tank [m ],,95 apacity of hot water 0 at storage tank temp. 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/5 90/5 750/5 60/0 90/0 750/0 apacity of hot water 0 at storage tank temp 80 and inlet water 5 / W flow rate* [l] / [l min ] 650/5 70/5 50/5 650/0 70/0 50/0 nsulation thickness (Neodul PP) [mm] 80 eatconductivityofinsulation(neodulpp) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 690 690 6905 Max. number output of TPK 0- [ks] [kw] Max. number output of TJ 6/" [ks] [kw] 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 80 7 0 80 7 0 Tank dimensions NADO 500/0v NADO 750/0v NADO 000/0v NADO 500/00v NADO 750/00v NADO 000/00v Tank diameter d 600 750 850 600 750 850 Total tank height 970 08 00 965 0 05 Tilting height K 990 050 060 985 05 080 Tank height 87 90 96 85 895 905 Discharging connection A 00 00 00 90 90 90 Z/T circuit socket 70 8 97 58 7 9 Z/T circuit socket 958 970 985 96 960 98 Z/T circuit socket 6 656 67 6 66 666 Sensor pocket socket 505 57 5 9 508 57 Sensor pocket socket 55 566 58 5 556 576 lange socket 5 66 8 57 75 TJ 6/" heating unit socket J 97 950 965 95 76 95 k k 5 7 d NADO 500/00v NADO 500/0v d 7

Storage tank NADO v : V : Types: 500, 750 l nner W storage tank in volumes of 00 and 50 The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as a storage tank for heating systems with heat pumps The TJ 6/" heating unit can be mounted into the socket Socket dimensions NADO 500/00v Socket dimensions NADO 750/50v Socket femalethread " Socket femalethread " Socket femalethread " Socket femalethread " Socket male thread " Socket male thread " Socket male thread " Socket male thread " Socket5 femalethread " Sensor pocket 5-50 NADO 500/00v NADO 750/50v Technical parameters NADO 500/00v NADO 750/50v Order number 80 680 eating water volume in tank [l] 75 77 Volume of storage tank for W heating [l] 79 60 Weight [kg] 5 80 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in W storage tank [ ] / [bar] 90 / 6 eat transfer surface of W storage tank [m ],58,5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/0 90/0 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 650/0 70/0 nsulation thickness (Neodul PP) [mm] 80 eatconductivityofinsulation(neodulpp) [W m K ] 0,0 nsulation order number (Neodul PP) 697 695 Max. number output of TJ 6/" [ks] [kw] 9 9 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 80 7 Tank dimensions NADO 500/00v Tank dimensions NADO 750/50v Tank diameter d 650 Tank diameter d 750 Total tank height 8 Total tank height 07 Tilting height K 8 Tilting height K 00 Tank height 69 Tank height 895 Z/T circuit socket 5 Discharging connection A 90 Z/T circuit socket 5 Z/T circuit socket 68 TJ 6/" heating unit socket 8 Z/T circuit socket 65 Sensor pocket socket 58 Z/T circuit socket 8 Sensor pocket socket 06 Z/T circuit socket 6 Sensor pocket socket 5 Sensor pocket socket 68 lange socket J 7 Sensor pocket socket 65 Sensor pocket socket J 060 Sensor pocket socket K 55 TJ 6/" heating unit socket M 65 TJ 6/" heating unit socket N 55 TJ 6/" heating unit socket O 585 lange socket P 8

A P M N O J K J 5 k 5 5 d NADO 500/00v 95 k x d 5 0 0 5 NADO 750/50v 9

Storage tank NADO v : T V : Types: 500, 750, 000 l nner W storage tank in a volume of 0 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an storage tank for heating systems with solid fuel boilers and solar systems The TPK 0/ heating unit can be mounted into the flange The TJ 6/" heating unit can be mounted for tanks with inner storage tank in a volume of 0 l Socket dimensions NADO 500/0v NADO 750/0v NADO 000/0v Socket female thread Socket female thread " " Socket male thread " Socket male thread " Socket 5 female thread " Technical parameters NADO 500/0v NADO 750/0v NADO 000/0v Order number 809 6809 5809 eating water volume in tank [l] 75 77 999 Volume of storage tank for W heating [l] 0 Weight [kg] 68 80 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in W storage tank [ ] / [bar] 90 / 6 eat transfer surface of W storage tank [m ], Max. operating temperature / pressure in exchanger [ ] / [bar] 0 / 0 eat transfer surface of exchanger [m ],5 xchanger volume [l] 0,5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/5 90/5 750/5 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 650/5 70/5 50/5 nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 Max. number output of TPK 0- [ks] [kw] 6 Max. number output of TJ 6/" [ks] [kw] 9 xchanger volume flow rate [m h ] 0, nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 79 6 8 Tank dimensions NADO 500/0v NADO 750/0v NADO 000/0v Tank diameter d 600 750 850 Total tank height 965 0 05 Tilting height K 985 05 080 Discharging connection A 90 90 90 Z/T circuit socket 58 7 9 Z/T circuit socket 96 960 980 Z/T circuit socket 6 66 666 Sensor pocket socket 9 508 57 Sensor pocket socket 5 556 576 Tank height 85 895 905 TJ 6/" heating unit socket 95 90 960 eat exchanger socket J 8 68 8 eat exchanger socket K 876 896 90 lange socket M 57 75 0

A J K M d k 5 95 x0 76 7 NADO 500/0v A J K M N k x0 95 76 7 d NADO 500v

Storage tank NADO v : T V : Types: 500, 750, 000 l nner W storage tank in a volume of 00 l The tank is supplied without insulation Modern Neodul insulation can be ordered Suitable as an storage tank for heating systems with solid fuel boilers and solar systems The TPK 0/ heating unit can be mounted into the flange Socket dimensions NADO 500/00v NADO 750/00v NADO 000/00v Socket female thread Socket female thread " " Socket male thread " Socket female thread " Technical parameters NADO 500/00v NADO 750/00v NADO 000/00v Order number 8088 68088 58088 eating water volume in tank [l] 75 77 999 Volume of storage tank for W heating [l] 9 Weight [kg] 68 95 0 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in W storage tank [ ] / [bar] 90 / 6 eat transfer surface of W storage tank [m ],5 Max. operating temperature / pressure in exchanger [ ] / [bar] 0 / 0 eat transfer surface of exchanger (top / bottom) [m ],5 /,5 xchanger volume (top / bottom) [l] 0,5 / 0,5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/5 90/5 750/5 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 650/5 70/5 50/5 nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 690 690 6905 Max. number output of TPK 0- [ks] [kw] 6 xchanger volume flow rate [m h ] 0, nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 80 7 0 Tank dimensions NADO 500/00v NADO 750/00v NADO 000/00v Tank diameter d 600 750 850 Total tank height 965 0 05 Tilting height K 985 05 080 Tank height 85 895 905 Discharging connection A 90 90 90 Z/T circuit socket 58 7 9 Z/T circuit socket 96 960 980 Z/T circuit socket 6 66 666 Sensor pocket socket 9 508 57 Sensor pocket socket 5 556 576 eat exchanger socket 8 68 8 eat exchanger socket J 876 896 90 eat exchanger socket K 050 06 08 eat exchanger socket M 578 589 6 lange socket O 57 75

Storage tank NADO v6 : T : Types: 00, 500, 750, 000 l eating by W flow in a stainless steel exchanger with an above-average heat transfer surface The tank is available with insulation in a volume of 00 l and without insulation in volumes of 500, 750, and 000 l Modern Neodul insulation can be ordered Various heat sources can be connected such as biomass, coal, gas and electric boilers, heat pumps and solar collectors The TJ 6/" electric cartridges can be mounted into sockets Socket dimensions NADO 00/0v6 NADO 500/5v6 NADO 750/5v6 NADO 000/5v6 Socket female thread Socket male thread " " Socket female thread " Socket female thread " Socket 5 male thread " NADO 00v6 NADO 500, 750,000v6 Technical parameters NADO 00/0v6 NADO 500/5v6 NADO 750/5v6 NADO 000/5v6 Order number 08098 8050 68050 58050 eating water volume in tank [l] 0 75 77 999 xchanger volume pro ohřev TV [l] 0 7 Weight [kg] 06 65 97 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in exchanger TV [ ] / [bar] 90 / 6 Max. operating temperature / pressure in heat exchanger [ ] / [bar] 0 / 0 eat transfer surface of exchanger TV [m ],5 6,5 8,5 0 W exchanger volume flow rate [m h ] 0,6 eat transfer surface of heat exchanger (top / bottom) [m ] /,6 /, /, /, eat exchanger volume (top / bottom) [l] / /8 /8 /5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 0/0 60/0 90/0 750/0 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 50/0 650/0 70/0 50/0 nsulation thickness (Neodul PP) [mm] 60 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) tank component 6957 6958 6959 Max. num. out. of TPK TJ 6/" h. unit with extended cooling section [ks] [kw],5 6 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 97 9 8 Tank dimensions NADO 00/0v6 NADO 500/5v6 NADO 750/5v6 NADO 000/5v6 Tank diameter d 550 600 750 850 Tank diameter with insulation D 670 Total tank height 60 965 0 05 Tilting height K 80 985 05 080 Tank height 658 85 895 905 Discharging connection A 80 90 90 90 Z/T circuit socket 8 58 7 9 Z/T circuit socket 96 008 00 Z/T circuit socket 8 65 670 69 W socket inlet 98 0 0 7 W socket outlet 8 60 670 69 Solar exchanger socket outlet 8 8 60 7 Solar exchanger socket inlet J 756 898 87 97 Sensor pocket socket K 58 8 05 59 Sensor pocket socket M 75 7 75 Sensor pocket socket N 7 09 09 Sensor pocket socket O 8 65 685 667 TJ 6/" heating unit socket P 86 985 007 0 TJ 6/" heating unit socket R 00 5 90 0

A J K M P N O R R 0 0' 5 d k 5 5 NADO 500, 750, 000v6 A-A: A 0 R A K O P J D d R k 5 5 NADO 00v6

Storage tank NADO v7 : T : Types: 500, 750, 000 l W heating in inner storage tank 00 l The tank is supplied without insulation Modern Neodul insulation can be ordered Various heat sources can be connected such as biomass, coal, gas and electric boilers, heat pumps and solar collectors The TJ 6/" heating unit can be mounted into sockets Socket dimensions NADO 500/00v7 NADO 750/00v7 NADO 000/00v7 Socket female thread Socket female thread " " Socket male thread " Socket male thread " Socket 5 female thread " Technical parameters NADO 500/00v7 NADO 750/00v7 NADO 000/00v7 Order number 807 8805 7805 eating water volume in tank [l] 75 77 999 Volume of storage tank for W heating [l] Weight [kg] 75 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in exchanger TV [ ] / [bar] 90 / 6 Max. operating temperature / pressure in heat exchanger [ ] / [bar] 0 / 0 eat transfer surface of W storage tank [m ],9 xchanger volume flow rate [m h ] 0,6 eat transfer surface of heat exchanger [m ],5,, eat exchanger volume [l] 8 5 5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/0 90/0 750/0 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 650/0 70/0 50/0 nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 69 6956 698 Max. num. out. of TPK TJ 6/" h. unit with extended cooling section [ks] [kw] 6 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 76 6 Tank dimensions NADO 500/00v7 NADO 750/00v7 NADO 000/00v7 Tank diameter d 600 790 790 Total tank height 965 95 5 Tilting height K 985 985 0 Discharging connection A 5 5 Z/T circuit socket 9 5 5 Z/T circuit socket 56 580 580 Z/T circuit socket 89 906 906 Z/T circuit socket 6 Z/T circuit socket 558 Z/T circuit socket 609 60 90 Tank height 85 85 5 Sensor pocket socket J 67 6 6 Sensor pocket socket K 680 68 68 Sensor pocket socket M 089 0 0 Sensor pocket socket N 0 Sensor pocket socket O 669 60 89 Solar exchanger socket outlet P 9 Solar exchanger socket inlet R 009 90 90 TJ 6/" heating unit socket S 069 069 5

6 A P J K R M N O S d 95 T T k 5 5 NADO 000/00 v7 d U k 0 75 75 A N P J K R T M O S 5 5 5 5 5 NADO 800/5 v9

Storage tank NADO v9 : T : Types: 800, 000 l eating by W flow in a stainless steel exchanger with an above-average heat transfer surface The tank is supplied without insulation Modern Neodul insulation can be ordered Various heat sources can be connected such as biomass, coal, gas and electric boilers, heat pumps and solar collectors The TJ 6/" heating unit can be mounted into sockets no. Socket dimensions NADO 800/5v9 NADO 000/5v9 Socket male thread " Socket male thread " Socket female thread " Socket female thread " Socket 5 female thread " Technical parameters NADO 800/5v9 NADO 000/5v9 Order number 880 780 eating water volume in tank [l] 80 999 Volume of storage tank for W heating [l] Weight [kg] 75 Max. operating temperature / pressure in tank [ ] / [bar] 90 / Max. operating temperature / pressure in exchanger TV [ ] / [bar] 90 / 6 Max. operating temperature / pressure in heat exchanger [ ] / [bar] 0 / 0 eat transfer surface of exchanger TV [m ] 8,5 W exchanger volume flow rate [m h ] 0,6 eat transfer surface of heat exchanger (top / bottom) [m ], /,, /, eat exchanger volume (top / bottom) [l] 8/5 5/5 apacity of hot water 0 at storage tank temperature 5 and inlet water 5 / W flow rate* [l] / [l min ] 60/0 750/0 apacity of hot water 0 at storage tank temperature 80 and inlet water 5 / W flow rate* [l] / [l min ] 87 / 0 50 / 0 nsulation thickness (Neodul PP) [mm] 80 eat conductivity of insulation (Neodul PP) [W m K ] 0,0 nsulation order number (Neodul PP) 699 699 Max. number output of TPK TJ 6/" heating unit with extended cooling section [ks] [kw] 6 nergy efficiency class (Neodul PP) Standing loss (Neodul PP) [W] 8 8 Tank dimensions NADO 800/5v9 NADO 000/5v9 Tank diameter d 790 790 Total tank height 95 5 Tilting height K 985 80 Stratification column socket A 56 56 Z/T circuit socket 879 95 Z/T circuit socket 09 09 Z/T circuit socket 9 55 W socket inlet 59 59 W socket outlet 599 889 Tank height 85 5 Solar exchanger socket outlet 89 59 Solar exchanger socket inlet J 99 09 Upper exchanger socket outlet K 5 9 Upper exchanger socket inlet M 55 85 Sensor pocket socket N 87 97 Sensor pocket socket O 57 8 Sensor pocket socket P 09 Sensor pocket socket R 9 Sensor pocket socket S 9 50 Sensor pocket socket T 9 5 TJ 6/" heating unit socket U 09 7

8-8 8-8 A A J J Storage tank UKV N : : Types: 00, 500 l The tanks are supplied with insulation Suitable as an equalization tank for heating systems with heat pumps The TJ 6/" heating unit can be mounted into sockets Socket dimensions N UKV 00 N UKV 500 Socket " female thread " female thread Socket " female thread " male thread Socket " female thread " female thread Socket " male thread UKV 00 UKV 500 Technical parameters N UKV 00 N UKV 500 Order number 0807 807 eating water volume in tank [l] 6 70 Weight [kg] 79 0 Max. operating temperature / pressure in tank [ ] / [bar] 90 / 6 nsulation thickness (Polyurethane) [mm] 50 eat conductivity of insulation (Polyurethane) [W m K ] 0,0 Max. number output of TJ 6/" [ks] [kw] 7,5 9 nergy efficiency class (Polyurethane) Standing loss (Polyurethane) [W] 79 96 Tank dimensions N UKV 00 N UKV 500 Tank diameter d 550 600 Tank diameter with insulation D 650 700 Total tank height 580 90 Tilting height K 65 955 Z/T circuit socket A 9 8 Z/T circuit socket 68 Z/T circuit socket 99 68 eating unit socket 09 68 eating unit socket 79 58 Sensor pocket socket 9 8 Sensor pocket socket 76 98 Sensor pocket socket J 99 68 Tank height 90 85 UKV 00 d D UKV 500 d D 8

eat insulation of the utmost quality Neodul PP heat insulation The delivery includes a top cover, flange covers and hole caps The NAD 00 and 50 v tanks are supplied with polyurethane insulation Plastic cover 80 mm cover insulation nsulation 80 mm Standard delivery for larger tanks The first and only category series insulation on the market Standard thickness of insulation is 80 mm xample of heat loss for 500 l tank:.9 kwh/ h with an insulation thickness of 00 mm Neodul PP bottom insulation 9

Original parts from Dražice month warranty period Reliability and high quality uarantee of functionality and safety uaranteed long life dentical components used in manufacturing asy availability throughout the zech Republic Anode with external power supply Used for protection of inner enamel storage tanks and extends their life span Usable up to a volume of 00 l Maintenance free, wear proof To order Diameter ength oat length mm 00 mm 00 mm langed heating units with ceramic body TPK eating flanges Seal eramic element Sheet cover of electrical installation eating flanges Seal eramic element Sheet cover of electrical installation TPK 0 /, kw TPK 0 / 6 kw, 5 9 kw, 8 kw 0

Original parts from Dražice Screw-type electrical heating units of TJ 6/" series TJ 6/" TJ 6/"- TJ 6/"-,5 TJ 6/"-, TJ 6/"-,75 TJ 6/"-,5 TJ 6/"-6 TJ 6/"-7,5 TJ 6/"-9 Order number / / / 000 / / / / 0006 / 0007 / 000 00 00 00 005 006 007 Power consumption [kw],5,,75,5 6 7,5 9 Weight [kg],,,7 /, /, Overalldimensions( /) [mm] 6 /55 6 /550 6 70/ 6 /595 6 /65 6 /665 6 70/80 6 750/865 xtension length / [mm] / 80 / 05 5 / / 50 / 500 / 50 575 / 685 605 / 70 lectrical connection /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ 0V/50z 0V/50z 00V/50z, 00V/50z, 00V/50z, 00V/50z, 00V/50z, 00V/50z, Recomm. circuitbreakervalue [A] 6 6 0 0 0 6 6 0 Degree of protection P Scale of set temperature [ ] 5 7 eat.timeapprox.50l0 60 [h],5,0,7,,0,5,,0 eat.timeapprox.50l5 60 [h],,0,5,,0 0,7 0,6 0,5 xtension lengths are in a tolerance of ± 0 mm. uilt-in electrical heating units of the R, S flange series R, S RU RDU RDU RDU RDU RDU RDW RDW RSW RSW 8-,5 8-,5 8-8-,8 8-5 8-6 8-7,5 8-0 8-8-5 S 77 S 78 Order number 00555 005560 00556 00556 00556 00556 005570 00557 005580 00558 00557 0055 Power consumption [kw],5,5,8 5 6 7,5 0 5 8--6 9,5-,7-9 Weight [kg],,,5,5,5,7, 8,5 Overall dimensions ( ) [mm] 88 560 88 60 88 70 60 70 60 870 xtension length [mm] 50 50 50 50 50 50 50 50 50 60 60 70 lectrical connection /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ /N/P ~ 0V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 00V/ 50z 50z, 50z, 50z, 50z, 50z, 50z, 50z, 50z, 50z, 50z, 50z, Recomm. circuitbreakervalue [A] 6 6 6 0 0 6 6 0 0 5 5 Degree of protection PX P0 eat.timeapprox.00l0 60 [h] 8,0 8,0 6,0 5,0,0,0,5,0,5,,0-,0-,,0-,5-,0 xtension lengths are in a tolerance of ± 0 mm. langed heating units with ceramic body TPK TPK TPK TPK TPK TPK TPK TPK TPK 50-8/, 68-8/, 0-/, 0-/-6 0-/6,6 0-/5-9 0-/8- Order number 009 0055 005 0050 00 005 005 Power consumption [kw],,, --6 6,6 5-7-9 8-0- Weight [kg],, 6,6,6 Overall dimensions ( ) [mm] 85 50 9 55 5 56 5 56 5 56 5 67 5 67 xtension length [mm] 00 00 0 0 0 550 550 lectrical connection /N/P ~ /N/P ~ /N/P ~ /N/P ~ 0V/50z, /N/P ~ 0V/50z, /N/P ~ /N/P ~ 0V/50z 0V/50z 0V/50z /N/P ~ 00V/50z, /N/P ~ 00V/50z, 00V/50z, 00V/50z, Recomm. circuitbreakervalue [A] 6 6 6 0/ 6 0/ 6 0 5 Degree of protection P Scale of set temperature [ ] 5 7 * according to connection method xtension lengths are in a tolerance of ± 0 mm.

Original parts from Dražice Mounting options for built-in electrical units of the R flange series Type RU 8,5 RDU 8,5 RDU 8 RDU 8,8 RDU 8 5 RDU 8 6 RDW 8 7,5 RDW 8 0 RSW 8 RSW 8 5 NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v5 NAD 750 v5 NAD 000 v5 NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 500/00 v NADO 750/00 v NADO 000/00 v NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 500/00 v NADO 750/00 v NADO 000/00 v can only be fitted with the 0/50 reduction flange cannot be fitted Mounting options for individual TPK electrical heating units Type TPK 0 /, kw TPK 0 / 6 kw TPK 0 /5 9 kw TPK 0 /8 kw NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v5 NAD 750 v5 NAD 000 v5 NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 500/00 v NADO 750/00 v NADO 000/00 v NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 500/00 v NADO 750/00 v NADO 000/00 v can be fitted cannot be fitted

Original parts from Dražice Mounting options for individual TJ electrical heating units Type TJ 6/" * TJ 6/",5* TJ 6/", TJ 6/",75* TJ 6/",5* TJ 6/" 6* TJ 6/" 7,5 TJ 6/" 7,5* TJ 6/" 9 TJ 6/" 9* NAD 00 v NAD 50 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 00 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v NAD 750 v NAD 000 v NAD 500 v5 NAD 750 v5 NAD 000 v5 NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 500/00 v NADO 750/50 v NADO 500/0 v NADO 750/0 v NADO 000/0 v NADO 00/0 v6 NADO 500/5 v6 NADO 750/5 v6 NADO 000/5 v6 NADO 500/00 v7 NADO 750/00 v7 NADO 000/00 v7 NADO 800/5 v9 NADO 000/5 v9 UKV 00 UKV 500 * TJ 6/" with extended cold side can be fitted cannot be fitted

ompany history The founding of the future cooperative company dates back to 900, when widow Marie Kyselová put a flour-mill into the company's property, thus establishing a producer cooperative called rain store, artistic cylinder mill and bakery in Dražice nad Jizerou. etween the years 90 and 97, with advice of engineer Karel Novák, professor at the Technical aculty in Prague, the new management headed by Václav Čančík focused on a very perspective production and distribution of electric power. A hydroelectric power plant with two turbines with an output of 00 P was built in 90. n 97, 69 villages with 8, consumers were connected to the Dražice power plant. The company got to its top in the second half of the 90s; it employed 0 employees and owned 8 hydroelectric power plants situated on the Jizera river, a steam-electric power plant, two mills, and a distribution network to which 8 villages with,080 users were connected. The turnover in 90 amounted to amazing three-quarters of billion zechoslovak crowns. n 98, after the forced sale of the distribution networks and the subsequent nationalisation of a large portion of the cooperative's property, the company focused its attention on products and services for people with the specialization in households and sports. ight years later, one of its programmes was the custom production of water heaters under the leadership of the former tradesman Mr. Křovák. At the end of the 980s, the Družstevní kombinát Dražice cooperative produced approximately,000 combined water heaters a year. After the political situation changed in 989, the cooperative was divided to independent trading companies. One of those companies was also a private company called Družstevní závody Dražice strojírna s.r.o., which took over the production of water heaters. An intense development started between the years 99 and 00. The range of products got wider, technologies were modernized and production increased continuously. The fundamental modernization took place at the end of 997 by building an enamelling line. The DZ Dražice company became the largest domestic seller of water heaters and in 99 it started to extend its export; the company exports its products to 6 uropean countries. n 00, the company produced 95,000 heaters. n 00, a new hall was built as in preparation of the construction of a new enamel kiln. That kiln was then built in the summer of 005 and allowed the company to increase the capacity of the enamel plant and to improve the enamelling process. n 005, the range of products was extended with storage tanks and, at the end of the year, new types of OK square-type water heaters were prepared. n that year, the company made 5,000 water heaters and employed 0 employees. n 006, 00% of interest of the DZ Dražice strojírna s.r.o. company were transferred to Swedish company N ndustrier A, which became the sole owner of DZ Dražice. During the summer of 007, the production was extended to two assembly lines and the capacity increased to 50,000 units per year. DZ Dražice also started to offer N heat pumps, as well as N solar systems and through-flow and stainless steel heaters. n the last years the company has focused on further extension of its range of products. n 0, the company extended its products with a water heater with heat pump, a hybrid heater with the option of connecting to photovoltaic panels, an outdoor storage tank. Also, it introduced a heater with smart control and a number of functions (OK SMART). n September 0, at the ortherm exhibition it presented its new model OK SMART VO with the possibility of control using smart phones.

Družstevní závody Dražice-strojírna s.r.o. Dražice 69, 9 7 enátky nad Jizerou Česká republika Tel.: +0/6 70 990 ax: +0/6 70 980 mail: prodej@dzd.cz www.dzd.cz January/08 The current version can be found on www.dzd.cz. The manufacturer reserves the right to changes.