FIRE SAFETY INSPECTION REPORT

Similar documents
FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

Letter of Recognition

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE ASSESSMENT REPORT (FAR)

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE ASSESSMENT REPORT (FAR)

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

ELECTRICAL SAFETY INSPECTION REPORT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Nirmal Chandra Sinha. Supposed to complete(dd/ MM/YYYY) Comments after Physical Inspection

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

January 1, 2014 Mandatory Effective Date

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

ELECTRICAL SAFETY INSPECTION REPORT

Agency for Health Care Administration

MWL Consulting Company

Life Safety - Means of Egress/Exits NFPA 101

TIME KNITWEAR (PVT) LTD.

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

2012 B.C. Building Code Compliance Review (Division B Part 3)

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Agency for Health Care Administration

CHAPTER 7 ALTERATIONS LEVEL

Agency for Health Care Administration

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Residential Care Facilities Requirements

ELECTRICAL SAFETY INSPECTION REPORT

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Large Family Daycare Guideline

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Osceola County Department of Fire Rescue and Emergency Medical Services

INITIAL FIRE SAFETY ASSESSMENT

Plan Review Check List Fire Alarm System

Common Building Code Misinterpretations

22A Belvedere Avenue, Parry Sound Sprinkler System Consulting Review

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Report on First Revisions with Statement June 2014 NFPA 101

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

Business License Pre-inspection Checklist

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

New Facilities. Minimum Requirements

Transcription:

FIRE SAFETY INSPECTION REPORT ABA FASHIONS LTD. SENA KALYAN COMMERCIAL COMPLEX (2ND FLOOR), PLOT # 9, BLOCK # F, TONGI, GAZIPUR March 16, 2014

Accord - Bangladesh RMG Fire Safety Inspection ABA Fashions Ltd. Page 2 SUMMARY ABA Fashions Ltd. was surveyed for fire safety on 3/16/2014 by Hughes Associates, Inc. This summary identifies the major deficiencies that were identified during the inspection. The purpose of this survey was to identify significant fire safety issues and to provide recommendations for remediation based on applicable standards specified by the Accord. The scope of this initial fire safety inspection was limited to the review and identification of major fire safety issues. The inspection did not include identification of minor deficiencies, which will be further addressed as part of follow-up inspections. Table 1 summarizes the major fire safety issues identified during the inspection. Recommendations have been provided to address each issue. An implementation schedule shall be developed by the factory to remediate each of the findings. The specific timing of improvements, including any requested extensions due to design / installation constraints, shall be submitted to the Accord for approval.

Accord - Bangladesh RMG Fire Safety Inspection 3 Table 1. Findings And Recommendations No. Category Finding Recommendation Remediation Timeframe F-1 Fire Rated Construction The utility rooms are not separated by fire-rated construction. - boiler rooms : Levels 2, 3, 4, 6 and 8 - Elec main panel : each level - generator and transformer room : ground floor -elevator shaft and elevator mechanical room: Level 9 Separate the utility rooms by a minimum 2-hr fire-rated construction. Seal and/or protected all openings to maintain the required fire separations Within 3

Accord - Bangladesh RMG Fire Safety Inspection 4 F-2 Fire Rated Construction The exit stairs are not separated from work areas and other spaces on each floor by firerated construction. Provide minimum 1.5-hr fire rated doors and seal all unprotected openings to separate the exit stairs from work areas and other building spaces on all floor levels. Ensure that the fire doors are self-closing and positive latching and that they are provided with fire exit (panic) hardware where serving production floors. Within 3 If fire doors are required to be held open for functional reasons, provide automaticclosing devices tied to the fire alarm system.

Accord - Bangladesh RMG Fire Safety Inspection 5 F-3 Fire Rated Construction Unsealed penetrations and openings are located in exit stair enclosures at the northeast stair on the 2nd floor, at the middle stair on the 3rd floor, and the southwest stair on the 5th floor. Seal all penetrations and openings in exit stair enclosure walls to maintain the fire separation. Within 3

Accord - Bangladesh RMG Fire Safety Inspection 6 F-4 Fire Rated Construction Areas used for combustible storage are not separated by firerated construction at all floors. Provide dedicated storage rooms separated by minimum 1-hr fire-rated construction. Where separate storage rooms are not feasible, provide defined storage areas and limit the storage arrangement as follows: - Maximum height of 2.4m and maximum area of 23m2 - If sprinkler protected: maximum height of 3.66m and maximum area of 93m2 Within 3 Separate areas of unenclosed combustible storage by a minimum clear distance of 3m.

Accord - Bangladesh RMG Fire Safety Inspection 7 F-5 doors / gates with locking features are provided at building exits and exit stairs. All gates/doors were open and unlocked during the inspection. Remove locking features from all egress doors / gates. If locks are required for security reasons, utilize special door locking features complying with NFPA 101. Immediate

Accord - Bangladesh RMG Fire Safety Inspection 8 F-6 Storage was located in the egress path at 4th floor. Keep egress paths and stairs clear of storage. Immediate F-7 Storage was located in the all exit stairs. Remove all storage from exit stairs and egress paths. Immediate

Accord - Bangladesh RMG Fire Safety Inspection 9 F-8 Means of exit discharge on the southwest portion of the building was found to be blocked by parked vehicles. Create a 'no parking' lane so that exiting occupants may reach a safe area of refuge away from the building. Within 1 month

Accord - Bangladesh RMG Fire Safety Inspection 10 F-9 Collapsible gates / sliding doors are provided at building exits and exit stairs Replace all gates / sliding doors along the means of egress with side-hinged, swinging egress doors. Within 3 If locks are required for security reasons, utilize special door locking features complying with NFPA 101.

Accord - Bangladesh RMG Fire Safety Inspection 11 F-10 A single means of egress is provided from the 7th floor office where the occupant load exceeds 49 persons. Provide an additional means of egress. Within 3 F-11 Exit stairs discharge inside the building. Modify stair to discharge directly outside or provide 2-hr fire-rated exit passageway leading directly outside. Within 6

Accord - Bangladesh RMG Fire Safety Inspection 12 F-12 Fire Protection The fire alarm system is antiquated, not a listed system, and does not provide alarm and notification features consistent with acceptable standards. Replace the fire alarm system with a new, listed addressable fire alarm system in accordance with NFPA 72. Design within 4, install within 9

Accord - Bangladesh RMG Fire Safety Inspection 13 F-13 Fire Protection The high-rise building has an occupied floor greater than 23m (75 ft) above grade and is not provided with automatic sprinkler protection. The large occupant loads, heavy fuel loading, and anticipated extended egress times warrant sprinkler protection. Provide automatic sprinkler protection throughout the building in accordance with NFPA 13. Design within 6, install within 12 F-14 Fire Protection Activation of the fire alarm system by a manual fire alarm station provides automatic occupant notification only on the floor of alarm and not throughout the building. Configure the fire alarm system to initiate automatic occupant notification on all floor levels to facilitate wholebuilding evacuation upon any manual fire alarm station activation. Within 1 F-15 Fire Protection Inspection, testing, and maintenance records for the fire alarm system were not available. Inspect, test and maintain the fire alarm system, and keep written records on-site, in accordance with NFPA 72. Within 3 F-16 Fire Protection The fire alarm system does not appear to provide adequate audible notification coverage at 3rd and 9th floors. Provide additional notification appliances such that the fire alarmsystem is audible throughout the building in accordance with NFPA 72. Within 6

Accord - Bangladesh RMG Fire Safety Inspection 14 F-17 Lighting An exit sign is not provided at the 7th floor office exit. Provide exit signs above all exits to the exterior and all doors to the exit stairs. Within 1 month F-18 Lighting Emergency lighting did not function in test mode (burned out, broken, etc.) at the northeast stair on the 4th floor. Reguarly test the emergency lighting system on each floor and replace/repair lights as needed. Within 1 month

Accord - Bangladesh RMG Fire Safety Inspection 15