E-Flow Pumps. Operating instructions

Similar documents
Zeolite Reactor ZA 509, ZA 512, ZA 616

MCE 400. Operating instruction and Spare parts list

Manuel Guide Lighting Fixtures

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

16" and 20" Economy Incandescent Full Hoods Owner s Manual

100 Series Maxi Internal Filters

CHAETOMAX. 2 in 1 Refugium LED. Owner s Manual 1

Lighting Placement. Adjusting Mounting Legs

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

A. Set-Up with gravel

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

Air Pump Up to 800 gallons

Fold Here. Stamp. Transworld Aquatic Enterprises, Inc 3730 W. Century Blvd #3 Inglewood, CA Phone: (877) JBJLIGHTING.

Clamp 4W Clamp 8W. Owner s Manual

Halo Programmable LED Aquarium Light. Quick Start Guide

AquaReef Cube. Inspiring Excellence in Fish Keeping!

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

SR-60 SR-80 SR-120. Owner s Manual 1

Owner s Manual Compact Fluorescent Lunar Aqualight

Chilller Arctic Instruction Manual

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

LINEAR AIR PUMPS INSTRUCTION MANUAL SERIES PRO TM

MiniMax Sump #7304. Owner s Manual 1

AQUARIUM HEATER RANGE AH-25 / AH-50 AH-100 / AH-200 AH-300

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

Installation & Maintenance Guide

Aquience 1200/1500 R

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

aquamanta the experts in aquatic technology

9 TWIN WINDOW FAN MODEL: FW23-A1 SKU:

HYDROFILL ATO Controller System

Important Safety Instructions 3-4

nova extreme retrofit High Output T5 Lighting Kit

Prime Chiller Mini-Chillers

Motion Sensor Oscillating Heater with Digital Control

TRANSWORLD AQUATIC ENTERPRISES INC.

Heater Upgrade Instructions

IMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS. WARNING To guard against injury, basic safety precautions USA

Prime Chiller 1/10th HP Chiller

gamma pond Ultraviolet Sterilizers

INSTALLATION AND INSTRUCTION MANUAL

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL IMPORTANT SAFETY INSTRUCTIONS

SUBMERSIBLE WATER PUMPS

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

SOUTHERN ENTERPRISES INC.

Operation Manual. Pond Pump Series HJ and CQP

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

HIGH VELOCITY METAL WALL MOUNT FAN 20" AMPS: 1.2 / WATTS: 140 / VOLT: 120 READ AND SAVE THESE INSTRUCTIONS

Electric Fireplace Instruction Manual

INTERRUPTERS. This message about... GROUND FAULT CIRCUIT. ...can save a life!

SolidFlo G2 Solid Handling Pumps Product Manual

Installation Instructions and Homeowner's Manual

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

EF5528RKD Freestanding Electric Fireplace

SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS

INTERRUPTERS. This message about... GROUND FAULT CIRCUIT. ...can save a life!

EF5802R Freestanding Electric Fireplace

Thanks for shopping with Improvements! Springfield Compact Electric Fireplace Item #470279

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

Homeowner s Installation Instructions & Operating Manual

OPERATION & MAINTENANCE INSTRUCTIONS

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

ASSEMBLY AND OPERATION MANUAL

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL

PERSONAL SIZE FIREPLACE

SUBMERSIBLE DIRTY WATER PUMP

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Installation Instructions and Homeowner's Manual

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONES IMPORTANTES CONSERVEZ LES PRESENTES INSTRUCTIONS

150 watt. Features: Watt Motor - 7.5" Stainless Steel Serrated Blade

INFRARED ZONE HEATING SYSTEM

1600 Watt Professional

EFX 200/300/400. aquamanta. the experts in aquatic technology. 4year guarantee. Instruction Manual. >400 Litres

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Gallery Electric Fireplaces

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

8.6" Slicer. Use and Care Instructions. Professional Performance. Includes: 150 watt DC motor 8.6" Stainless Steel conclave blade

20" Air Circulator MODEL: FB50-9HA

Turbo Circulating Fan (DC)

Gallery Electric Fireplaces

OPERATING INSTRUCTIONS

150 WATT. Features: Watt Motor - 7.5" Stainless Steel Serrated Blade

CAUTION SERVICE CENTRE:

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

20 High Velocity Fan with 135 Tilt Head

ECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS

EA0045RC ELECTRIC FIREPLACE

User Manual. Electric Countertop Burners. Models: EB100, EB102 05/2017. Please read and keep these instructions. Indoor use only.

Outdoor Beverage Center

Reflex. Inspiring Excellence in Fish Care!

Transcription:

E-Flow Pumps Operating instructions

IMPORTNT SAFETY INSTRUCTIONS WARNING To guard against injury, basic safety precautions should be observed, including the following. 1) READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2) DANGER To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility for service or discard the appliance. a) If the appliance shows any sign of water leakage, immediately unplug it from the power source. b) Carefully examine the pumps after installation. It should not be plugged in if there is water on parts not interned to be wet. c) Do not operate the pumps if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner. d) To avoid the possibility of the pumps plug or receptacle getting wet, position aquarium stand and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug. A drip-loop, shown in the figure below, should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The drip-loop is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water travelling along the cord and coming in contact with the receptacle. If the plug or socket does get wet, DON T unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the appliance. Then unplug and examine for presence of water in the receptacle. 3) Close supervision is necessary when any appliance is used by or near children. 4) Always unplug an pump from an outlet when not in use, before putting an or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect. 5) Do not use the pump for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition. 6) Make sure an appliance mounted on a tank is securely installed before operating it. 7) Read and observe all the important notices on the appliance. 8) If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should bee taken to arrange the cord so that it will not be tripped over or pulled. 9) This pump has a polarized plug (UK and US version). As safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature. Exception: This instruction may be omitted for an appliance that is not provided with a polarized attachment plug. Removing of the plug invalidates the warranty! SAVE THESE INSTRUCTIONS

E-FLOW PUMPS Type 10, 12 and 16 Deltec E-Flow pumps are brushless motor, true sine wave pumps. They incorporate the lasts technology in energy saving and performance control. They come with a separate controller. The power consumption and performance can be selected with the up/down buttons located on the face of the controller. The pumps revolutions are fully automatically adjusted until the set wattage has been reached (not a mere revolution control). The pump itself can be installed either dry outside the sump or submersed inside the sump or aquarium. The controller is not submersible. See instructions on page 5 Important safety instructions Deltec E-flow pumps are designed /manufactured according to existing technical standards and safety regulations. However there is a potential risk to persons and goods if the pumps or safety instructions are not being observed. Persons under the age of 16 or persons who are unable to understand possible risks or do not fully understand the safety and operating instructions are not allowed to use this pump for safety reasons. Keep these instructions in a safe place where it is accessible at all times. Please read the following instructions very carefully before installing the pump. Should you still have questions please contact your supplier. Installation of the pump - Always unplug the pump during the installation process. - After unpacking check pump, controller and cables for any damage. If any components show signs of damage, do not use the pump. - The pumps are designed for dry or submersible installation in fresh or seawater aquarium systems. - The pumps are not self priming and need to be installed below the water level. - The separate controller must be placed in a dry, cool area, to prevent damage to the electronic control circuits through water or dampness. - To install, place the pump on a firm, even surface. - Never select pipes or hoses smaller in diameter than that of the pumps suction and pressure side fittings. Shut off valves should be selected one size bigger and fitted with reducers down to the normal pipe diameters, since the normal inner shut off valve diameter restricts the flow considerably. - To achieve best performance, plan the piping as short as possible, use slow bends instead of elbows. - On longer pipe installation increase the diameter of the pipes. Instead of 32 mm use 40 mm, etc. - It is good practice to use a straight length of pipe of app 300 mm on the suction side of the pump. This will give a laminar flow into the pump and prevent unwanted noises - Never run the pump dry, this may lead to irreparable damage. -3-

- Never put your fingers into the pump s suction or pressure side with the pump connected to mains electricity. - When using flexible hoses make sure that they are suitable for the pumps performance and do not leach out dangerous substances into the water. - When using non return valves ensure proper function, otherwise there is great danger of the pumps running dry. - If required, use a strainer with app 2-3 mm opening on the suction side. When using finer filtration (sponges etc) make sure that they are always cleaned at short intervals, to prevent cavitations and possible damage to the pump. - Do not operate the pump with a shut off valve on the suction side, partly or fully closed. Installation of the controller Install the controller in a dry, suitably vented place, away from water, dampness and other heat sources like sunlight, artificial light etc. For optimum cooling effect of the controller housing, it is best to mount it vertically. Use the holes in the controller s bracket. Never cover the controller. Resulting overheating could damage the controller Starting the pump Check that the power supply is suitable for the pump. Refer to the pumps label. Use the pump with an electric circuit breaker. Overload protection E-Flow pumps are protected against overloading. If the impeller is blocked the pump is switched off automatically. If the cause of the blockage is removed the pump can be restarted or will start on its own. Power cut new start After a power cut or the pump having being switched off, the pump will assume its old setting when the power comes back on. -4-

Controller panel 1) Remote, red light The pumps can be equipped with a separate multifunction controller (available April 2012). This controller enables the pump to be used in a interval or random mode. Up to four pumps can be controlled with one multifunction controller. If the multifunction controller is used, the red light comes on. 2) Green light It indicates that the power is on. 3) Display a) It shows the set wattage of the pump. b) It shows the faults of the pump with a code, see fault finding next page. 4) Arrow buttons Setting the wattage. -5-

F1 F2 F3 F4 F5 Fault finding with the display code Dry running. Shows when the pump has been started without water, press the up arrow button to start the pump again. Shows excessive temperature inside the controller. The pump performance is automatically reduced to prevent any damage. After the source of the increased temperature has been removed, the pump performance can be selected again with the up/down buttons. Starting error. If the pump rotor is blocked, the pump will switched off after starting. After removal of the blockage the pump can be started again by disconnecting and reconnecting the pump from mains electricity. Rotor blockage during operation. Should the rotor stop during normal operation due to foreign particles. The pump switches off after 3 restarting attempts. Remove the blockage and restart (low voltage) the pump by disconnecting / reconnecting from mains electricity. If the local voltage is too low the pump will switch off automatically. F7 Init Fault. This indicates a fault in the controller. It may be possible in some cases to rectify it by disconnecting / reconnecting the pump from mains electricity. If not the pump has to returned to Deltec for inspection. Technical Data technical data E-Flow 10 E-Flow 12 E-Flow 16 volume max. at 1.1 meter 9.000 litre./h 11.400 litre./h 14.000 litre./h water head max. 6,0 meters 8,0 meters 9,0 meters power consumption max. 80 Watt 130 Watt 180 Watt performance selection electronic, 7 stages electronic, 12 stages electronic, 17 stages voltage 230/240 Volt 230/240 Volt 230/240 Volt inlet diameter 40 mm ø 40 mm ø 50 mm ø outlet diameter 32 mm ø 40 mm ø 40 mm ø dimensions pump (l/w/h) mm 195x132x212 200x135x214 dimensions controller (l/w/h) mm 190x215x65 190x215x65 190x215x65 weight 3,50 kg 3,60 kg -6-

-7- Deltec GmbH

Steller Straße 75 D-27755 Delmenhorst Deutschland / Germany www.deltec-aquaristic.com Deltec GmbH 2012