SHALLOW MOUNT HYDRAULIC ROAD BLOCKER/MODEL PROTECTOR

Similar documents
INDEX. 1.1 Main Features Environmental Conditions and Power Requirement Optional Accessories Tyre-Killer Main Parts...

BL41 Extra-long Barrier

IntesisBox BACnet/IP Server - Notifier ID3000 series

CV-350 TCP/IP Access Control System. System Overview

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

Panel Mounted Fault Annunciator Series

BLG77 Rising Fenced Barrier

Engineering Specifications

Controlled access gates especially designed to allow people quick, safe and controlled access to installations of all types.

Professional perimeter intrusion detection system

Tripod Turnstiles. Tripod Turnstile for Public Transport Application

TCR. Features: TISSUE CULTURE

Solution F2. Fire Alarm Control Panels one step ahead.

5736 N. Michigan Road Indianapolis, IN 46228

Panel Mounted Fault Annunciator Series

5736 N. Michigan Road Indianapolis, IN 46228

TURNSTILES REVOLVING DOORS MAN-TRAP CUBICLES VEHICLE BARRIERS SPEEDGATES

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

561-MB48. Intruder Alarm Control Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Mine Automation Technologies. know-how performance reliability

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

G /6000 BTU/Hr. 1172/1758 Watt

Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD. ASSA ABLOY Entrance Systems

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

APPLICATION DATA SHEET

WORLD LEADER IN TEST TECHNOLOGY InterTech is a manufacturer of turnkey automated systems with proven technology for leak and functional testing.

TPF Series Ozone Generators

Safety vacuum drying oven for flammable solvents

N Volt 1800 BTU/Hr. 527 Watt

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

For Complete Fire and Gas Solutions

SPECTRACOOL INDOOR/OUTDOOR

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

NET BARRIER REDUCED RISK FINAL DENIAL VEHICLE BARRIER Model Va-Net-300

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Commend Columns. Security and Communication. Help and Information Points for people in need of assistance. Doors, Gates and Entrances

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

TCC-34. Features: TISSUE CULTURE

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

LAYOUT The system requires no data network. Very simple installation. Only 220V ac power supply indispensable. LEGEND P ET C P COIN BAR PAN KIT CAP

Access Control. Total Perimeter Protection Solutions from one Source

HRX3000. Technical Manual

Machine Protection Door

sintra Sintra is a trademark of Asya Traffic INC.

alarm system VERSA Plus

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

G /6000 BTU/Hr. 1172/1758 Watt

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Different types of Fire Alarm System

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

Universal fault annunciator for panel mounting

561-MB256 plus. Intruder alarm control panel. Performance features

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Technical Manual. Level Alarm Unit CARLA & WIDS

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Complete Boiler Management in a Compact, Affordable System

Specification for Rising Bollards Control System

2 OZONFILT And Bono Zon Ozone Plants

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

Pay Station PKE. Parking System. Intuitive Interface Easy to use. Multifunction Station. Kiosk for different uses

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

INSTALLATION INSTRUCTIONS

Half-Dome. the Design-Tower. Compact

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

K B N 2 PARTS WASHING SYSTEMS

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

N Volt 1800 BTU/Hr. 527 Watt

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

CAESAREA SUBSTATION BATTERY ENERGY STORAGE SYSTEM PREFABRICATED EQUIPMENT CONTAINER SPECIFICATION ATTACHMENT TO ANNEXURE "B"

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Service manual. Type: TD25. Contents

Integrated Security Solutions

DAP III Zone Master User s Guide

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Assembly. Host Sub-D Alarm

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Contents. 30 References

SlimStile BA. Tripod Turnstile for Internal Installation (*)

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Mobile measurement technology for HV components

Transcription:

/MODEL PROTECTOR Technical information: Solid steel construction with hot dib galvanized & RAL coating. Width: Height: Construction height: Electrical engine: Electrical system: Operating time: Operating temperature: Main power: Protection rated: Warranty: From 1.0 to 4.0 meter 550mm 200mm Hydraulic unit with three phase motor PLC system on separate cabinet approx 4.0 to 5.0 second (optional 1.5s with EFO) -40*C to +60*C (optional 70*C) 3x400VAC 50Hz K4 24 months File ver. 5, revised 25.01.2018

MODEL PROTECTOR Installation type: Structure type: Width of blocked space: Height of raised obstacle: PLC (Programmable Logic Controller) type: PLC (Programmable Logic Controller) location: Electro-hydraulical drive unit: Underground Solid steel construction with hot dib galvanized From 1000 mm to 4000 mm Standard is 550 mm MITSUBISHI PLC located in external cabinet (service worldwide) In external cabinet located up to 7 meter away from road blocker In external cabinet up to 7 meter away from road blocker. A lockable weather resistant enclosure/cabinet is provided for the HPU. The desing provides easy access to HPU for maintenance and emergency operations of the hydraulic system. Enclosure is provided in the corrosion resistant coating.

MODEL PROTECTOR Axis load: Standard 8 tones (higher axis load available on request, please Contact our sales department) Operation temperature: From -40 to +60 degree Celsius (higher temperatures available on request, please contact our sales department) Top cover: Made of 6 or 8 mm anti sliperry checker plates hot dip galvanized acc. ISO EN 1461 Standard equipment (included in the basic set): - Guardian panel for operations - Integrated line of photocells - Service keys in cabinet RAISING-STOP-LOWERING - Emergency stop button - Hydraulic Manual Emergency Pump (Manual operation in case of power supply failure, allows to raise and lower the road blockers in case of power failure) - 9 m long Hydraulic Hose and electric wires Emergency manual opening: By integrated hydraulic Manual Emergency Pump Corrosion protection: All steel elements hot dib galvanized, mobile obstacle powder painted to YELLOW/BLACK Control devices: Service keys in cabinet RAISING-STOP-LOWERING Emergency stop button Opening time: Approx. 4-6 seconds Emergency manual opening: By integrated hydraulic pump Corrosion protection: All steel elements hot dib galvanized acc. ISO EN 1461, moving element painted yellow/black strips External cabinet system protection grade: IP 55 Power supply: Resistance to impact: 3x400VAC 50Hz, Very resistance to impact (stop a heavy vehicle launched at high speed) rated by desing to K4 (ASTM F2656-07 M30-P1) standard.

MODEL PROTECTOR OPTIONAL EQUIPMENT Against surcharge, not included in the basic set Emergency Fast Opening (1,5 seconds) by Hydraulic Accumulator 2 channel loops detector UPS (Unlimited Power Supply) allowing to operate a chosen amount of cycles Separate traffic post with LED RED/GREEN light Remote controller Proximity card post Internet online control module TCP/IP Ethernet online control module (LAN) Integration with Milestone, Honeywell (Prowatch) or Bosch (BIS) system

MODEL PROTECTOR ELEMENTS OF SYSTEM The system consist of: - Road Blocker which absorbs the impact - Outside Cabinet with Control Box with drive unit which is to be placed up to 7 meter form the Road Blocker Both elements of the system are connected with 9 metres long electrical cables and 9m long hydraulic hoses, which have to be place into the ground in round connection pipes during mechanical installation.

MODEL PROTECTOR

MODEL PROTECTOR EXTERNAL CABINET WITH DRIVE UNIT & CONTROL UNIT HPU + internal cabinet HPU+ Internal Cabinet IP66 External Cabinet IP55 Internal Cabinet IP66

MODEL PROTECTOR STANDARD EQUIPMENT Control Console MODEL PROTECTOR OPTIONAL EQUIPMENT Proximity Card Reader Loop Detector LED traffic post UPS/ Unlimited Power Supply Safety Photocells Hydraulic Accumulator for Emergency Fast Operations LED traffic light on separate post