Centeral Station Air Handling Unit

Similar documents
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Double Skin Casing Air Handling Units

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR HANDLING UNITS. Revision AG 16-07

AIR HANDLER SPECIFICATION

1.1 This section applies to air handling units for HVAC Systems.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

EHH SERIES DRAW THROUGH FAN COILS CFM

Double Skin Air Handling Units

Easdale International INFINITY

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

General Catalogue. FORM SSI - G.C (94)

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

39G Air Handling Unit

SECTION AIR HANDLING UNIT

Modular Supply Make-Up Air Unit

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Cert. n Air Conditioning Vulcan Pro Air Handling Units

Advance Release September 2009

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Double Skin Air Handling Units

Air Handling Units. Real HVACR people who understand your needs.

TYPICAL CPA SPECIFICATIONS

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Modular Air Handling Unit

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

YMA Custom Air Handling Units

Modular Heating & Ventilating Unit Model IGX-HV

Air Handling Units. T F E.

ENGINEERING & SERVICE

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

Direct Fired Heater Model AD Specification

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

INTRODUCTION.3 PRODUCT SPECIFICATIONS. 3

Indoor Air Quality. For assured. Double Skin Air Handling Units

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ALL PRODUCTS BROCHURE

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

The ultimate in air handling units: directly and indirectly fired

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

The ultimate in air handling units: directly and indirectly fired

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. Codes and Standards that are Standard at the University:

Plenum Fans. Model HPA. Direct Drive

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

DIVISION 15 MECHANICAL

AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.

SeasonMaker ThinLine Fan-coil Units

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

YMA Air Handling Units

Air Handling Units. direct drive - belt drive - custom built

C13-Series Engineering Guide

VertiCool Aurora Engineering Guide

VERTICAL FAN COIL UNITS

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

39FD, FX. Air Handling Units. 280 l/s to l/s 39FD, FX

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Indirect Gas-Fired Make-Up Air

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

CENTRAL SPLIT UNIT UNIC

MLR SERIES MODULAR AIR HANDLING UNITS

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SeasonMaker ThinLine Fan-coil Units

The ultimate in air handling units: directly and indirectly fired

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Direct Gas-Fired Make-Up Air

SKYPAK II, 3 Ton Series, gives you a

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

SKYPAK II, 3 Ton Series, gives you a

University of Delaware

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Direct Gas-Fired Make-Up Air Models DG and DGX

Transcription:

Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com

The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof top Air Conditioning Units. BASIS OF SELECTION OF DOUBLE SKINNED AIR HANDLING UNITS - CA SERIES MODEL NOMINAL AIR VOLUME FAN DIA / OUTLET COIL FACE WIBD cfm m 3 / hr L / sec mm m 2 m 2 020 1,165 2,000 550 180 / 0.0529 0.22 030 1,757 3,000 830 250 / 0.1036 0.33 045 2,647 4,5000 1,250 280 / 0.1310 0.50 065 3,822 6,500 1,805 315 / 0.1630 0.72 080 4,700 8.000 2,220 355 / 0.2060 0.89 105 6,185 10,5000 2,920 400 / 0.2580 1.16 130 7,645 13,000 3,610 450 / 0.3250 1.44 160 9,400 16,000 4,440 500 / 0.4070 1.77 200 11,750 20,000 5,550 560 / 0.5120 2.22 230 13,530 23,000 6,390 630 / 0.6430 2.56 280 16,455 28,000 7,770 710 / 0.8060 3.11 350 20,600 35,000 9,720 800 / 1.0160 3.88 400 23,530 40,000 11,110 800 / 1.0160 4.44 500 29,415 50,000 13,890 900 / 1.2770 5.56 600 35,300 60.000 16,670 1000 / 1.6080 6.67 700 41,170 70,000 19,440 1000 / 1.6080 7.77 800 47,050 80,000 22,220 1000 / 1.6080 8.88 Detailed fan and coil selections available on request. Non standard - custom designed and built Air Handling Units is WINS`S specialty. - 2 -

Model CA Air Handling Units are designed to give effective treatment of the air and are manufactured incorporating corrosion resistant materials, such as anodised profiles and stainless steel fixings. 1) CASING: Double skinned panels are fixed to an anodized aluminum alloy framework with stainless steel screws, forming a rigid casing enclosing the various air treatment sections such as mixing, filtration, heating, cooling, humidification, supply fan, extract fan. If required, various other sections such as heat recovery, multizone, sound attenuators can be incorporated. Air tight sealing is ensured through a neoprene gasket between the panel and the frame. Depending on the application and the operating environment, there are several options while selecting the composition of the double skinned panels. TYPE CA : Panels are of double skinned construction with insulation between two solid metal sheets. PANEL THICKNESS: 25mm or 50mm. PANEL MATERIALS: INNER SHEET (SOLID) Galvanized steel (plain/prepainted/preplasticised) Peraluman (Al. Alloy) Stainless Steel Sheet Galvanized Steel OUTER SHEET (SOLID) Galvanized steel (plain/prepainted/preplasticised) Peraluman (Al. Alloy) Stainless Steel Sheet Galvanized Steel PANEL INSULATION: MATERIAL DENSITY THERMAL CONDUCTIVITY kg/m 3 watt/m C Pressure injected foam 50 0.0189 Mineral Wool 80 0.0370 ACCOUSTIC PROPERTIES OF CA PANELS OF 25 MM THICKNESS: FREQUENCY 125 250 500 1K 2K 4K Sound Transmission Loss db (STC: 31) 22 24 31 34 38 25 Sound Absorption Coefficient (NRC:0) - - - - - - ACCOUSTIC PROPERTIES OF CA PANELS OF 50 MM THICKNESS: FREQUENCY 125 250 500 1K 2K 4K Sound Transmission Loss db (STC: 35) 25 28 32 35 39 34 Sound Absorption Coefficient (NRC:0) - - - - - - OPTIONAL: Casing type CA constructed with special sealing to meet high pressure Class C leakage rate when tested in accordance with DW/143-3 -

Type CAP: Panels are of double skinned construction with insulation between two 1.0 mm thick metal sheets. The inner sheet is perforated while the outer sheet is solid. PANEL THICKNESS: 25mm or 50mm. ACCOUSTIC PROPERTIES OF CAP PANELS OF 25 MM THICKNESS: FREQUENCY 125 250 500 1K 2K 4K Sound Transmission Loss db (STC: 27) 20 25 30 33 26 51 Sound Absorption Coefficient (NRC: 0.65) 0.18 0.31 0.62 0.80 0.89 0.77 ACCOUSTIC PROPERTIES OF CAP PANELS OF 50 MM THICKNESS: FREQUENCY 125 250 500 1K 2K 4K Sound Transmission Loss db (STC: 29) 21 26 31 35 38 59 Sound Absorption Coefficient (NRC: 0.95) 0.27 0.63 1.05 1.09 1.01 0.93 PANEL MATERIALS: INNER SHEET (PERFORATED) Galvanized steel (plain) Peraluman (Al. Alloy) Galvanized Steel OUTER SHEET (SOLID) Galvanized steel (prepainted/preplasticised) Peraluman (Al. Alloy) Galvanized Steel PANEL INSULATION: MATERIAL DENSITY THERMAL CONDUCTIVITY kg/m 3 watt/m C Mineral Wool 80 0.0370 RECOMMENDATION: In view of their sound absorption characteristics, type CAP panels are recommended for fan sections or where attenuation is required to minimize the noise transmission into the ductwork. - 4 -

2) CONSTRUCTION: a) ACCESS DOORS: For inspection or maintenance of the components in various sections such as filters, fans, motors, coils, etc., double skinned access doors are provided either fully removable or with hinges made of die cast aluminum. b) RETURN/INLET PLENUM: Return/inlet plenums with same construction as unit casing can be supplied with or without opposed blade, volume control damper. c) BASE FRAMES: Units are supplied with a heavy gauge galvanized base frame. This base frame extends under the complete unit if unit is supplied in one section or under each section if unit is supplied in split sections. Optional: Intake Louver d) FILTER SECTION: Filter Banks are designed for easy withdrawal and replacement of filters. Fully sealed filter frames are designed to accommodate various types of filters such as: e) MIXING BOX & DAMPERS: Mixing Boxes are of same construction as the unit casing and are available with two or three dampers arrangement with configuration to suit the plant room ductwork. Dampers are sized for 6.0 m/ sec velocity. Dampers are of opposed airfoil blade type. Airfoil blades are made of aluminum alloy extrusions and are assembled in aluminum alloy framework. Optional - Panel filters - Automatic filters - Bag filters - Absolute filters Filters of specified manufacturer Filter manometers Filter pressure switches - Activated carbon filters - Intertial sand filters - Oil bath filters - Electrostatic filters f) COIL SECTION: Cooling/heating coils are computer selected to obtain specified heat exchange capacities. Cooling coils are of chilled water or direct expansion type, while heating coils are of hot water or steam type. Coils are made of copper tubes, mechanically bonded to aluminum fins, assembled in heavy gauge galvanized frame work. Water and steam coils are complete with galvanized steel headers while DX coils are with copper headers and brass refrigerant distributor. All coils are leak tested under water at 30 bar. Coils are mounted within the coil section to facilitate easy withdrawal. Drain pan made of stainless steel sheets is provided under the cooling coil section with threaded drain outlet. Optional Copper headers for water coils Vinyl coated aluminum fins Copper fins HERESITE coate coils Electro-tinning of Cu/Cu coil after manufacture. Stainless steel coil frame Run aruond coils - 5 -

g) MOISTURE ELIMINATOR: If necessary, moisture eliminators can be fitted after the cooling coil / humidifier section to avoid carry over of moisture. Eliminator blades are made of polypropylene and are assembled within a heavy guage galvanized steel frame. Optional: Eliminator blades made of galvanized sleel / prepainted steel / stainless steel, with frames made of galvanized steel sheets. h) HUMIDIFYING SECTION: Following types of humidifiers are available; Airwasher complete with recirculating pump, water distribution pipework, spray nozzles, inlet strainer, drain pan with overflow and moisture eliminator. Wet deck complete with recirculating pump. Spray coils. Pan and electric resistance. Self generated steam package. Alternatively, blank sections can be supplied to incorporate steam distributor / injector with steam from an external source. i) FAN SECTION: DIDW centrifugal fans with forward curved or backward curved imellers are available with various outlet configurations. Fans and casings are made of corrosion resistant materials or given corrosion resistant finish. All fan wheels and pulleys are statically and dynamically balanced and keyed to the shaft. Fan shafts are made of high quality solid steel and are supported on pregreased sealed for life ball bearings. Fans are driven by TEFC motor located within the unit casing. Fan and motor are mounted on a common base frame with facility to allow easy belt tensioning. Fan & motor assembly is isolated from the unit casing by antivibration mounts and a flame retardant flexible connector on the fan discharge. Optional: Fan casing and impellers hot dip galvanized after manufacture. Inlet guide vanes. Axial fans with variable van control. Fans with anti spark features. Fan casing with drain plugs and inspection doors. Belt guards. Two speed, variable speed or any other special motor. j) HEATER BATTERIES: Electric heater batteries are supplied with sheathed electric resistance heating elements made of finned steel tubes assembled within a galvanized steel frame. Entire assembly is located within the casing of the heating section. EHaters can be supplied with various capacities / stages as required. Optional: Heating elements made of stainless steel / copper tubes. Overheat thermostat or other controls. Terminal block with internal prewiring. 3) OTHER APPLICATIONS: Units can be supplied incorporating the following sections; Face and Bypass. Multizone. Dual duct. Heat recovery. Non standard units can be designed to meet client's constraints and to operate at severe climatic environments. 4) ACCESSORIES: On request, units can be supplied with the following accessories; Weatherproof roof canopy. Inspection window. Bulkhead lights. - 6 -

- 7 -

- 8 -

- 9 -

- 10 -

Nomenclature Type W : Wall Split T : Cassette Split F : Floor Standing U : Universal Split D : Ducted Split H : Horiz. Cond. Unit V : Vert. Cond. Unit P : Roof Top Package L : Chilled Water FUC C : Air Handling Unit AHU K : Window Unit Series Nominal Capacity MB TU/Hx1000 BTU/H Cooling Only - C C A 018 C 1 A R E E: elect. heat optional N: no elect heat R: R-22 N: R-407 C D: R-410 A A: T1 Stand. Ambient B: T3 Hi Ambient Heat pump - H Electncal code : 1 220-240v/ 1ph/50hz 2 208-230v/ 1ph/60hz 3 110-120v/ 1ph/60hz 4 380-420v/ 3ph/50hz 5 200-230v/ 3ph/60hz 6 460v/ 3ph/60hz www.windind.com - 11 -

P.O.Box 741074 - Dallas, Texas 75374 USA Tel. +972 563 9289 - Fax. +972 563 5783 Email : info@windind.com www.windind.com