REMOTE CONTROLLER OWNER S MANUAL

Similar documents
Portable Room Air Conditioner Remote Control for:

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

DVC/DVH 09/12/18/24 Series

SET TEMPERATURE( F) AUTO COOL DRY HEAT TEMP MODE SWING RESET LOCK LED DISPLAY

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR054-RG51B

REMOTE CONTROLLER CR057-RG51Q&J MANUAL

OWNER S & INSTRUCTION MANUAL

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

SPLIT-TYPE ROOM AIR CONDITIONER

REMOTE CONTROL MANUAL

Remote Control Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

OWNER S MANUAL VMH 09/12/18/24

Remote Control Operation Manual Split Type Air Conditioner

Remote Control User Manual

REMOTE CONTROLLER KSWM units

SYSCONTROL RM 52. SYSPLIT Type Remote controller user manual CR090 RG52A A

CONTENTS ,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons...

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR137-RG51F

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM. Quick-Start Guide ON/OFF TEMP MODE SILENCE FP FAN SPEED SWING TIMER ON SWING TIMER OFF SLEEP

AIR CONDITIONER REMOTE CONTROLLER MANUAL

Utopian Portable A/C

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons Auto operation...

SERIES AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

REMOTE CONTROL MANUAL

A IR CONDITIONE R REMOTE CONTROLLER ILLUSTRATION CR087-RG05F2EU

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

CR034-RG36F

Buttons on remote controller

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

CR193-RG70E2(2)BGEU

USER MANUAL MIDEA FAIRWIND

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

Remote Controller Manual

Portable Air Conditioner Instruction Manual

Portable Room Air Conditioner and Heat Pump

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

Operating Functions Temperature Parameters

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR004-RG35/

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Remote Control Instructions


Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Slim Line Ceiling Concealed Ducted Split Systems

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

PORTABLE AIR CONDITIONER

WHYNTER ECO-FRIENDLY 10,000 BTU PORTABLE AIR CONDITIONER

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

Operating Instructions

Hi Wall Split Air Conditioners

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

HEAT CONTROLLER, INC.

BTU Units WORKING PROGRAM MANUAL

CR103-RG57A3. REMOTE CONTROLLER ILLUSTRATION (Function selection)

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

5) Do not start or stop the unit by inserting or pulling out the power plug.

Wall Mounted Mini Split Heat Pump Air Conditioner

9,000 BTU Portable Air Conditioner PE1-09R-30. Model No. PE I-O9R Soleus Air International

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Owner s Manual TABLE OF CONTENTS

WIRED CONTROLLER MANUAL

ENGLISH REMOTE CONTROL MANUAL

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Owner s Manual TABLE OF CONTENTS

WALL MOUNTED AIR CONDITIONER

Inverter Air Conditioner User Manual KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

WORKING PROGRAM. Heating dehumidifying cooling T 27

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Dual-Hose Portable Air Conditioner User Manual

Remote Control Features & Functions

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

Ductless Split Air Conditioner

HMCI 125F-EH MOVABLE TYPE AIR CONDITIONER WITH OZONE-FRIENDLY R410A REFRIGERANT USER S MANUAL CAUTION:

USER MANUAL MPF. EasyCool Portable. MPF08CR71 MPF10CR71 MPF12CR71 MPF14CR71

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

ACCESSORIES INCLUDED

Ductless Split Air Conditioner

REMOTE CONTROLLER RG57

Remote Control Features & Functions

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

PORTABLE AIR CONDITIONER OWNER'S MANUAL. Model: MPM3-12HRN1-BH9 Model: MPM3-14CRN1-B I 6

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

WALL MOUNTED AIR CONDITIONER OWNER S MANUAL

Transcription:

REMOTE CONTROLLER OWNER S MANUAL B-SMA/SMH09/12/18SC Single Zone Mini-Splits B-VMH09/12/18/24/30/36SC-1 Single Zone Inverter Mini-Splits B-VMH09/12/18FC-1 Multi-Flex Inverter Mini-Splits Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com

Owner s Manual Remote Controller Heat Controller, Inc. Table of Contents Using the remote controller... 2 Remote controller specifications... 3 Function buttons... 4 Indicators on LCD display... 6 How to use the buttons... 7 Auto operation... 7 Cooling/Heating/Fan operation... 7 Dehumidifying operation... 8 Swing operation... 8 Timer operation... 9 Ecomony operation... 12 1

Heat Controller, Inc. Remote Controller Owner s Manual Using the Remote Controller Use the remote controller within a distance of 26' 3" (8 meters) from the appliance, pointing it towards the receiver. Reception is confirmed by a beep. receiver housing Remove the battery cover by pressing and sliding it off. 2

Owner s Manual Remote Controller Heat Controller, Inc. an extended period of time. Remote Controller Specifications Model* R51l5BG(C)E, R51l6/BG(C)E, R51l7/BG(C)E, R51l8/BG(C)E, R51l9/BG(C)E; R51l10/BG(C)E, R51l11/BG(C)E, R51l12/BG(C)E; Rated Voltage 3.0V (Dry batteries R03/LR03x2 or (2) AAA) Lowest Voltage of CPU Emitting Signal 2.0V Signal Receiving Range 26'3" (8m) Environment -41 F~140 F (-5 C~60 C) *NOTE: Temperature setting display: Fahrenheit scale ( F): R51l9/BG(C)E; R51l10/BG(C)E, R51l11/BG(C)E, R51l12/BG(C)E Celsius scale ( C): R51l5BG(C)E, R51l6/BG(C)E, R51l7/BG(C)E, R51l8/BG(C)E Performance Feature Indoor setting temperature range: 62 F~88 F (17 C~30 C) Full function of LCD Display (Liquid Crystal Display) 3

Heat Controller, Inc. Remote Controller Owner s Manual Function Buttons AUTO COOL DRY HEAT* FAN *NOTE: Heat pump models only ION and FOLLOW buttons are optional functions. 4

Owner s Manual Remote Controller Heat Controller, Inc. Function Buttons (continued) ECONOMY Button (Sleep Mode) to maintain the most comfortable temperature TIMER OFF Button ION and FOLLOW buttons are optional functions. Press this recessed button to lock all current settings. Use the LOCK mode when you want to prevent settings from being changed accidentally. Press the LOCK button again to cancel the LOCK function. A key symbol will appear on the remote controller display when the lock function is activated. 5

Heat Controller, Inc. Remote Controller Owner s Manual Indicators on LCD Display The temperature setting (from 62 F (17 C) to 88 F (30 C)) or timer setting (0~24h) will be displayed. If FAN mode is selected, there will be no display. A key symbol is displayed when pushing the LOCK button. Push the LOCK button to clear display. 6

Owner s Manual REMOTE CONTROLLER Heat Controller, Inc. How to use the buttons 2 1 3 Auto operation Ensure power is available to the unit. The OPERATION indicator on the display panel of the indoor unit illuminates. 1. Press the MODE button to select Auto. 2. Press the TEMP button to set the desired temperature. The temperature can be set within a range of 62 F (17 C)~88 F (30 C) in 2 F (1 C) increments. 3. Press the ON/OFF button to start the air conditioner. NOTE 1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, Heating and Dehumidifying by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller. 2. In the Auto mode, you can not switch the fan speed. It is automatically controlled in this mode. 3. If the Auto mode is not comfortable for you, the desired mode can be selected manually. 2 1 4 3 Cooling/Heating/Fan Operation Ensure power is available to the unit. 1. Press the MODE button to select COOL, HEAT (cooling & heating models only), or FAN mode. 2. Press the TEMP button to set the desired temperature. The temperature can be set with a rnage of 62 F (17 C)~88 F (30 C) in 2 F (1 C) increments. 3. Press the FAN SPEED button to select the fan speed in four steps Auto, Low, Med or High. 4. Press the ON/OFF button to start the air conditioner. NOTE In the FAN mode, the setting temperature is not displayed in the remote controller. In fan only mode, the fan creates a breeze without cooling or heating the room. To cool or heat the room, cooling or heating modes need to be selected rather than fan only. 7

Heat Controller, Inc. REMOTE CONTROLLER Owner s Manual 2 1 3 Dehumidifying operation Ensure power is available to the unit. The OPERATION indicator on the display panel of the indoor unit illuminates. 1. Press the MODE button to select DRY mode. 2. Press the TEMP button to set the desired temperature. The temperature can be set within a range of 62 F (17 C)~88 F (30 C) in 2 F (1 C) increments. 3. Press the ON/OFF button to start the air conditioner. NOTE In the Dehumidifying mode, you can not switch the fan speed as it is being automatically controlled. Swing operation direction. 1 direction setting feature of the louver is activated. The angle of the louver changes by 6 each time the button is pressed. Keep pressing the button to move the louver to the desired position. 2. By pressing the SWING button without releasing it for 2 seconds, the auto swing feature of the louver activates. The horizontal louver swings up/down automatically. Press it again to stop. NOTE When the louver moves to a position which would affect the cooling and heating effect of the air conditioner, it will automatically change the swing/louver direction. 8

Owner s Manual Remote Controller Heat Controller, Inc. Pressing the TIMER ON button can set the auto-on time of the unit. And pressing the TIMER OFF button can set the auto-off time of the unit.. symbol SEE NOTE. symbol SEE NOTE ON NEXT PAGE. symbol 9

Heat Controller, Inc. Remote Controller Owner s Manual 10

Owner s Manual Remote Controller Heat Controller, Inc. symbol h will 11

Heat Controller, Inc. REMOTE CONTROLLER Owner s Manual ECONOMY (SLEEP MODE) operation When you press the ECONOMY button, the economy/sleep mode running function will be activated, the set temperature will increase (in cooling) or decrease (in heating mode) by 2 F (1 C) over the next 30 minutes and by another 2 F (1 C) after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. (NOTE: On some models, the set temperature will increase (cooling) or decrease (heating) by 2 F (1 C) per hour for 2 hours. This new temperature will be maintained for 5 hours, then the unit turns off.) NOTE: The ECONOMY/SLEEP function is only available under Cooling, Heating and Auto operation. 12

10/2012