TFI Report Classification

Additional Reaction to Fire Classification Report

Centrum stavebního inženýrství a.s.

Test Report: ICL/CR15/11/087

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Reaction to fire classification report No C-rev.1

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Additional reaction to fire classification report No H

Reaction to fire classification report No C

CLASSIFICATION REPORT

Form: KSD-100:10 Page 1 of 3

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Centrum stavebního inženýrství a.s.

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

DELTA Classification Report

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

Classification Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

New European Fire Testing Classification for Construction Products

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

TFI Report Classification

Not all insulation is the same! from fire testing to real fires.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

CERTIFICATE OF APPROVAL No ME 5085

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

Facts about insulation and fires 29 October 2014

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Construction Products Directive

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

BS EN ISO : 2010

BS EN ISO : 2010

Institute of Building Technology. Classification report no: Reaction to Fire acc. PN-EN A1:2010

New European Cable Testing and Classification

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

BCTC CARPET TECHNICAL CENTRE

BS EN ISO : 2010

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

MEDIUM-DENSITY HOUSING # 7. Fire safety

Analysis Report

TEST REPORT. Fire tests of construction products in compliance with the following standard:


White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

BS 476: Part 6: 1989+A1:2009

Appendix A: US Fire Statistics Tables

UK Direction BS7671 BS 8492 BS /01/2018

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Development of a European approach to assess the fire performance of facades

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

FAÇADE FIRE TESTS Towards a new European standard method

Üntel is ready for CPR

Abrasion Resistance of Fluoropolymer and polyester Coatings

Construction Products Regulation (CPR) and BS 6701

Analysis Report

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

TFI Report Reaction to fire test

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Fire Safety Fire Resistant Building Components

IMO Resolution MSC 61(67): Annex 1: Part 2

BS 476: Part 6: 1989+A1:2009

FIRE TUBE Fire protection for process pipes and structural steel

2.2 Factors in design

Classification for burning behavior of building materials and products

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Urbanscape Landscaping Solutions

EFFISUS BRAZE MEMBRANE

Classification of Fire Performance of Wall and Ceiling Lining Materials

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13


Test Report: ICL/H18/9039 Rev 1

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Transcription:

- Restricted Classification report Reaction to fire classification report of product Fibo-Trespo Bathroompanels / Respatex Bathroompanels Author Gunn Hofstad SINTEF NBL as Reaction to fire 2012-07-04

Table of contents 1 Description of the product... 3 2. Test reports and test results in support of this classification... 3 2.1 Test reports... 3 2.2 Test results... 4 3. Classification and field of application... 3.1 Reference... 3.2 Classification... 3.3 Field of application... 4. Limitations... 7 1 2 of 7

1 Description of the product The product is fully described in the test reports in support of the classification listed in Clause 2. Fibo-Trespo Bathroompanels / Respatex Bathroompanels is a waterproof covering system of plywood with high pressure laminate on the front side and a protection laminate on back side. The plywood has 7 layers and the high pressure laminate has a thickness of approximately 0.85 mm and the laminate on the backside has a thickness of approximately 0.73 mm. Total thickness is approximately 10.2 mm. The product is manufactured in different colours, the tested product was the one with the highest content of organic material. The colour code for the product: Decor no.: 3091 F00 White NCS colour code: S 0500-N Before testing the following information was recorded: - Nominal and measured thickness: 10.2 mm - Nominal thickness: 790 kg/m 3. Measured square density and density: respectively 8.04 kg/m 2 and 789 kg/m 3. - Measured density, mineral wool: 14.4 kg/m 3, thickness: 70 mm, euroclass A1 according to NS-EN 13501-1 Sealant: Fibo Seal, Sealant & Construction Adhesive, MS Polymer 2. Test reports and test results in support of this classification 2.1 Test reports Table 1 Test report in support of the classification of Fibo-Trespo Bathroompanels / Respatex Bathroompanels. Name of laboratory Name of sponsor Test report ref. no. Test method SINTEF NBL Fibo Trespo AS, Norway 102010.35/12.03 :2010 SINTEF NBL Fibo Trespo AS, Norway 102010.25/12.034 NS-EN 13823:2010 1 3 of 7

2.2 Test results Table 2 Test results from tests according to, in support of the classification of Fibo-Trespo Bathroompanels / Respatex Bathroompanels. Test method Parameter Number of tests Surface flame attack, front* Surface flame attack, back* Edge flame attack, front* Edge flame attack, back* Edge flame attack, centre* Edge flame attack, centre* with substrate * : : as required to the end use application of the product not applicable Continuous parameter mean (m) Results Compliance parameters 1 4 of 7

Table 3 Test results from tests according to NS-EN 13823, in support of the classification of Fibo- Trespo Bathroompanels / Respatex Bathroompanels. Test method Parameter Number of tests NS-EN 13823 Tested with air gap behind the product FIGRA 0,4MJ [W/s] LFS < edge THR 00s [MJ] 4 Continuous parameter mean (m) 249.4 22.9 Results Compliance parameters SMOGRA [m 2 /s 2 ] TSP 00s [m 2 ] 0** 9.2 Flaming droplets/ particles NS-EN 13823 Tested with insulation behind the product FIGRA 0,4MJ [W/s] LFS < edge THR 00s [MJ] 3 28.0 27.7 SMOGRA [m 2 /s 2 ] TSP 00s [m 2 ] 1.7 7.4 Flaming droplets/ particles NS-EN 13823 Tested with the particle board mounted to the back side FIGRA 0,4MJ [W/s] LFS < edge THR 00s [MJ] 3 231. 21. SMOGRA [m 2 /s 2 ] TSP 00s [m 2 ] 0**.8 Flaming droplets/ particles : **: not applicable Notice that SMOGRA is equal to zero because the threshold level for average smoke production rate was not exceeded. 1 5 of 7

3. Classification and field of application 3.1 Reference This classification has been carried out in accordance with clause of 8, 11 and 15 in NS-EN 13501-1:2007+A1:2009. 3.2 Classification The product Fibo-Trespo Bathroompanels / Respatex Bathroompanels in relation to its external fire performance is classified: D The additional classification in relation to smoke production is: s1 The additional classification in relation to flaming droplets/particles is: d0 The format of the reaction to fire classification for construction products excluding floorings is: Fire behaviour Smoke production Flaming droplets D - s 1, d 0 i.e. D s1, d0 3.3 Field of application This classification is valid for the following end use conditions based on the tests performed and reported in task no. 102010.25/12.034 and 102010.35/12.03: Substrates: Airgap: Any end-use wood based substrates, with thickness thi k, ha i g a de sity kg/m 3. Any end-use substrates of Euroclasses A1 or A2-s1,d0. Any airgap of 40 mm Insulation: Mi eral ool ha i g a o i al de sity 14.4 kg/m 3. Mounting: Mechanically fixed to a timber or metal framework. The framework can be attached to a substrate of wood with thickness, ha i g a de sity kg/ 3 and any substrates having classifications A1 or A2-s1,d0. 1 of 7

Sealant: Colour: Fibo Seal, Sealant & Construction Adhesive, MS Polymer Any colour of the product Fibo-Trespo Bathroompanels / Respatex Bathroompanels 4. Limitations This document does not represent type approval or certification of the product. 1 7 of 7

Technology for a better society www.sintef.no