SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

Similar documents
SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking:

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Installation manual Mini Comfort 50 S/L 07/ V EN

HEAT RECOVERY AIR HANDLING UNIT

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

manual addendum DELPHI Ex

FAN IMPELLERS & FAN CASINGS

TUNNEL FANS STANDARD AND HOT SMOKE

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Technical Data. Dimensions

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Operating instructions

Technical Ventilation

1. GENERAL INTRODUCTION 2. OPERATING CONDITIONS

Domestic & Commercial Fans

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Wind. Service instruction

Turbo. Service Instructions

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

HEATING AND COOLING DEVICE AGC

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

GLEB Kitchen exhaust fan

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

VERSO Air Handling Units

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

INDUSTRIAL AIR FILTRATION SYSTEMS LOCAL FILTER UNITS

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Centrifugal Fans, Non-Overloading, Backward Inclined

RS Chimney Fan for Solid Fuel Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

RS Chimney Fan for Solid Fuel Applications

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Technical Data. Dimensions

KITCHEN EXTRACTORS K Series

DUST COLLECTORS DC 200 DC 230 E DC 250 CF DC 300 DC 350 CF DC 400 DC 450 CF DC 500 E DC 550 CF DC 600

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

CombiBloc Close-coupled centrifugal pumps

When you think safety think Systemair

Operating Instructions

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

Inductive slot sensor

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Annubar Flowmeter Series

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

ROOFMASTER STEF-HT ROOF FAN

Smart encoders & actuators

VERSO Air Handling Units

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Instructions for use PHPC 6.4F AM X

XI'AN KOSUN MACHINERY CO.,LTD.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

Part No KEMPER Filter-Master XL

Vacuum Hose Reel 881 Ex

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Bruksanvisning Directions for use

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

Calm. Service Instructions

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Implementation of ATEX Guidelines

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Operating Instructions

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

AZN ATEX INSTALLATION AND MAINTENANCE

Exp, pressurized systems

Transportation. Distribution

Technical Data. Dimensions

Explosion-proof Immersion Heater Type D-8660

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

CATA WORLDWIDE In over 80 countries

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

INTELLIGENT AXIAL FAN user's manual

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Fan Heaters Type VLEx

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

Transcription:

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

ROOF FANS TABLE OF CONTENT GENERAL SELECTION SVH2/SVV2 GENERAL SELECTION SVK2/EX SVK2 ROOF FANS TYPE SVH2 AND SVV2 Designation Dimensions Technical data ROOF FANS TYPE SVK2 Designation Dimensions Technical data ROOF FANS TYPE EX SVK2 Designation Dimensions Technical data ACCESSORIES MOUNTING EXAMPLES Page 2 Page 2 Page 3 Page 3 Page 4 Page 4 Page 5 Page 5 Page 7 Page 8 Page 11 Page 11 Page 12 Page 13 Page 14 Page 15 GENERAL SELECTION SVH2/SVV2 GENERAL SELECTION SVH2/SVV2 v17.1.0 - Page 2

ROOF FANS TYPE SVH2 and SVV2 Use Roof fans SVH2 type with horizontal outlet and SVV2 type with vertical outlet are suitable for ventilation systems of industrial buildings, workshops, garages, apartment blocks, lavatories, shopping malls and other large spaces for the transport of dust free air and other non-aggressive gases. Technical description Fans have impellers with back-curved blades, which assure good efficiency ratio and low noise level. Impeller and electromotor are dynamically balanced in G 6.3 class by ISO 1940-1. Electromotor with impeller are mounted on the fan casing trough the shock absorbers, which assure vibrations dampening inside a fan casing. Base plate with inlet funnel enables minimal entry losses. Screws on the base plate ensure easy connection of all additional inlet accessories. Protective caps at SVH2 and external casings at SVV2 are made of Al sheet metal. Impellers of both designs are protected against touch with safety mesh. Mesh also prevents animals, leafs or other larger parts to enter the fan. Fans ensure long lasting operation, with long service intervals, for low cost operation and maintenance. Temperature range: - ambient temperature: -15 to 50 C Drive Roof fans type SVH2 and SVV2 have electric motors with external rotor. Standard motors for sizes 250/200 and 315/250 are monophase, one-speed, 230V/50Hz, with integrated thermal protection. Roof fans sizes from 400/315 to 560/500 have three-phase, two-speed, 400V/50Hz motors with thermal protection sensors (TK). Sensor leads must be connected to the external protective device in switchboxes or speed controllers. All electromotors have IP 44 protection. Start, stop and RPM regulation of the fan is possible with one or two speed switch and five speed regulator. Accessories Standard accessories are flexible connections, back draft shutters, roof upstands and silencers. Designation v17.1.0 - Page 3

ROOF FANS TYPE SVH2 and SVV2 SVV2 SVH2 Dimensions Technical data v17.1.0 - Page 4

ROOF FANS TYPE SVH2 and SVV2 NOTE: Sound pressure L pa [dba] is for SVH2. It is defined sideways on 4m distance on an outlet side and 4m under suction side with directivity factor Q=2. Sound pressure correction on pressure side for type SVV2 is -2 dba. v17.1.0 - Page 5

ROOF FANS TYPE SVK2 Use Roof fans type SVK2 with vertical outlet and three phase IEC electromotors are designed for ventilation systems of industrial buildings, kitchen hoods, workshops, garages, laundries and lavatories for air with increased humidity and pollution. Max air temperature is 120 C. Fans are designed for airflow range up to 50.000 m3/h and pressure 2000 Pa. Technical description Fans have welded impellers with back-curved blades, which assure good efficiency ratio and low noise level. They are dynamically balanced in G 6.3 class according ISO 1940-1. Electromotor with impeller are mounted on the fan casing trough the shock absorbers, which assure vibrations dampening inside a fan casing. Base plate with inlet funnel enables minimal entry losses. Screws on the base plate ensure easy connection of all additional inlet accessories. External casings are made of Al sheet metal. Impellers are protected against touch with safety mesh. Mesh also prevents animals, leafs or other larger parts to enter the fan. Fans ensure long lasting operation with long service intervals - low cost operation and maintenance. Temperature range: - ambient temperature: -20 to 50 C Drive SVK2 type roof fans have integrated standard three-phase electro motors 3x400V; 50Hz, IP55, IM V1. For each fan size it is possible to select electromotor between one and two-speed speed. Motors are also equipped with PTC sensors for thermal protection. Start, stop and RPM regulation of the fan is possible with two speed switch or frequency converter, depending of the electromotor power. Accessories Standard accessories are flexible couplings, back draft shutters, roof upstands and silencers. Special design We also produce special SVK2 designs by costumer s demand. Standard designs in production are roof fans for hazardous areas - Ex design (pg. 11) and ODT-SVK2 roof fans - for smoke and heat extraction class F400 according to EN12101-3 (brochure ODT-SVK). Designation v17.1.0 - Page 6

ROOF FANS TYPE SVK2 Dimensions v17.1.0 - Page 7

ROOF FANS TYPE SVK2 Technical data Motors with different RPM and electrical parameters are offered on customer s request. Motors for Ex design are specified at EX SVK2 fan type (page 13). v17.1.0 - Page 8

ROOF FANS TYPE SVK2 v17.1.0 - Page 9

ROOF FANS TYPE SVK2 NOTE: Defined sound pressure L pa [dba] is measured sideways on 4m distance! v17.1.0 - Page 10

ROOF FANS TYPE EX SVK2 Roof fans for hazardous area Explosive composition of gases and fumes with air, which are result of production process, or consequence of malfunction. Mixture ignition with spark or excessive heating of individual parts, can cause explosion or fire. Roof fans type EX SVK2 are designed according to directives, which prevent explosion or fire, due to their operation. Also the customer has to strictly consider all the regulations and guidelines, by selection, mounting, usage and maintenance of the fan. Application The use of the roof fans EX SVK2 is permitted for hazardous zones in industrial areas: - hazardous zone 0: not allowed - hazardous zone 1: Ex II 2G c IIB T4 - hazardous zone 2: Ex II 3G c IIB T4 Technical description Explosion proof EX SVK2 fans are similar to standard SVK2 type, with construction improvements, which conforms to directive 94/9/ES and norm EN 13463-1 & EN 14986. Temperature range: - ambient temperature: -20 to 40 C Drive EX SVK2 fans have standard three-phase electromotors 3x400V; IP55, 50Hz with explosion proof protection II 2G EEx de IIC T4 and PTC sensors for thermal protection. RPM regulation Start, stop and RPM regulation is possible with one or twospeed switch or frequency converter. For switches and frequency converters is mandatory to mount them outside of the hazardous zone. Switches for installation inside of the hazardous zone are available by specific customer s request. Designation example: EX SVK2 560/500-4/6 II 2G c IIB T4 Designation v17.1.0 - Page 11

ROOF FANS TYPE EX SVK2 Dimensions v17.1.0 - Page 12

ROOF FANS TYPE EX SVK2 Technical data Motors with different RPM and electrical parameters are offered on customer s request. v17.1.0 - Page 13

ACCESSORIES v17.1.0 - Page 14

MOUNTING EXAMPLES Roof fan is designed so, that it is ready for mounting without any connection accessories. Following points have to be considered by mounting: Upstand has to be straight, suitable dimensions (see brochure) and stiff enough regarding the weight of the fan. Fan is mounted on the upstand with four nuts or bolts, which have to be suitably sealed. Upstand has to be correctly positioned and mounted on the roof or plate with suitable hydro-insulation, to prevent entry of water inside a building (not shown!). Temperature dilatation has to be considered, especially for accessories. v17.1.0 - Page 15

We reserve the right to changes without prior notice. Almeco Belgium (HQ) ALMECO NV Royennestraat 51 B-7700 Moeskroen +32 (0)56 85.40.80 Almeco The Nederlands ALMECO NEDERLAND BV Postbus 32 NL-5550 AA Valkenswaard +31 (0)40 80.80.000 Almeco France ALMECO FRANCE SARL Rue de Luxembourg 67 FR-59777 Euralille +33 (0)3 28.48.26.68 ALMECO sa Air and water technologies info@almeco.eu - www.almeco.eu