Horizon Elite Ice Machine Installation Instructions for Harmony Top-mount Applications

Similar documents
Maestro Plus Ice Machine Installation Instructions for Harmony Top-mount Applications

Maestro Plus Ice Machine with RIDE Technology Installation Instructions for Harmony

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Vision

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Vision

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Drop-In

Horizon Ice Machine Installation Instructions to Ice Storage Bin Top-mount Applications

Horizon Ice Machine Installation Instructions for Ice Storage Bin Top-mount Applications

Horizon Ice Machine Models with RIDE Technology Installation Instructions for Vision

Maestro Plus Ice Machine with RIDE Technology Installation Instructions for Vision

ice storage bin RIDE ice & beverage Cornelius PR150 undercounter top mount 3 countertop ice & beverage (by others) drop-in dispenser RIDE (by others)

For use with 1. ice storage bin. Follett Vision undercounter ice & beverage dispenser. Cornelius PR150 undercounter ice & beverage dispenser 2

For use with 1 Install/mount Condenser V/Hz/Ph Item number 4. ice storage bin. Follett Vision undercounter ice & beverage

For use with 1. ice storage bin. Follett Vision undercounter ice and beverage dispenser Cornelius PR150 undercounter ice and beverage dispenser

For use with 1 Install/mount Condenser V/Hz/Ph 1010 series 1410 series. ice storage bin

Use/ application. top. with ice storage bin RIDE. with Follett Vision dispenser RIDE. top. with ice and beverage dispenser (by others) RIDE

Horizon Chewblet ice machine series or 1400 series air-cooled or water-cooled (See model number guide)

Use/ application. top mount. with ice storage bin RIDE. with Follett Vision dispenser RIDE. top mount with. ice and beverage dispenser (by others)

Maestro Plus. Features. self-contained 425 series Chewblet RIDE ice machine

Use/ application. top mount. with ice storage bin RIDE. with Follett Vision dispenser RIDE. with. ice and

Maestro 400 series ice machine Use/ application. top mount. with ice storage bin RIDE. with Follett Vision dispenser RIDE.

Description Follow these instructions to install the Maestro Plus ice machine module into your Symphony FB, CT, and CI dispenser.

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Operation and Service Manual

U.S. Patents 7,263,844, 7,469,548,and 7,469,552. HCD1400RBS shown

Maestro Plus. Features. self-contained C/E 425 series Chewblet RIDE ice machine

HCC/HMC1000A, HCC/HMC1000W Ice Machines

Operation and Service Manual

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

LIST PRICE SCHEDULE. ice machines. ice and water dispensers. ice and beverage dispensers. ice storage and transport

Countertop and Freestanding Ice and Water Dispenser with Chewblet Ice Machine 7CI100A, 7FS100A, 15CI100A, 15FS100A

Contents. Solutions, inspired by ice. Ice machines. Ice storage bins. Ice dispensers

LIST PRICE SCHEDULE. ice machines. ice and water dispensers. ice and beverage dispensers. ice storage and transport

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

effective January 1 ice machines ice and water dispensers ice and beverage dispensers ice storage and transport LIST PRICE SCHEDULE

HCD/HMD/HCF/HMF1000R, HCD/HMD1000N Ice Machines

Undercounter Ice and Water Dispenser with Chewblet Ice Machine 7UC100A, 7UD100A

Countertop and Freestanding Ice and Water Dispenser with Chewblet Ice Machine 7CI100A, 7FS100A

Following installation, please forward this manual to the appropriate operations person.

Undercounter Ice and Water Dispenser with Chewblet Ice Machine E7UC100A, E7UD100A

HCD1000R, HCD1000N Icemakers

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

Symphony Plus 110 Series Ice and Water Dispensers

Ice Pro DB650, EDB650 Automatic Ice Bagging and Dispensing System

Product Manual. Scotsman. Models: 10150, and 10250

ICE/BEVERAGE DISPENSER

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

Symphony Plus 25 and 50 Series Ice and Water Dispensers 25FB425A/W, 50FB425A/W

Symphony Plus Pressurized Water Sanitizing Kit P/N

Horizon Elite Chewblet ice machines superior technology delivering value and reliability

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

Cornelius Installation Guidelines for Ice Settings

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

Follett Chewblet ice machines... environmentally responsible. Chewblet Ice. Cube Ice. What is Chewblet ice?

HCC1400A, HCC1400W Icemakers

Symphony Plus 25 and 50 Series Ice and Water Dispensers 25FB425A/W, 50FB425A/W

UC300. INSTALLATION & SERVICE GUIDE Part Number

User information. Cleaning/descaling and sanitizing

MODELS: TJ45 TJ90 Operator s Manual

Ice and Sparkling Water Dispenser with Chewblet Ice Icemaker 7CI100A, 7FS100A, 15CI100A, 15FS100A

VU155K Integral Cold Carbonation Series Ice and Beverage Dispensers

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

Prodigy and Prodigy Plus Flaked and Nugget Modular Ice Machines. and Prior

U155 Series Ice and Beverage Dispensers

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

LANCER SERIES 4500 IBD25

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

Ice Pro DB1000 Series Automatic Ice Bagging and Dispensing System

110 Series Ice and Water Dispensers

INSTALLATION AND SERVICE MANUAL FOR ICE BEVERAGE DISPENSERS, IBD22 - IBD30 LANCER SERIES 4500

Music to your ears. Follett s Symphony Series ice and water dispensers

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

STARBUCKS UC100 PROGATE

Operator Manual Powdered Beverage Dispensers PIC3, PIC33A, PIC5, PIC6

Water Boilers ME10EN, ME15EN. Table of Contents

SCHWAN INSTALLATION GUIDE

ILLUSTRATED PARTS LIST ENDURO VALVE

Ice and Water Dispensers 25CI400A/W, 25HI400A, 50CI400A/W, 50HI400A

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

Ice and water dispensers. Ice and water dispensers

ICE/BEVERAGE DISPENSER

INSTRUCTION SHEET KIT CONVERSION, PELLET ICE, HEX, FOR THE IBD30 AND FS30 DISPENSERS - INSTALLATION INSTRUCTIONS

Symphony Plus ice and water dispensers. sanitation and patient safety. Exclusive features for

Ice and water dispensers. Ice and water dispensers

Install Guide Billi Quadra & Quadra Plus (Gooseneck)

ICE/BEVERAGE DISPENSER

CAUTION: READ OPERATOR S MANUAL BEFORE USE Electric Kettle

Whynter Countertop Direct Connection Ice Maker and Water Dispenser - Silver

10L Evaporative Cooler with Timer

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Please read the following installation instructions first after purchasing this product or transporting it to another location.

Refresh & Clean Carpet Washer

SLUSH PUPPiE MACHINE Instructions For Use

Installation and User's Manual for Flake and Nugget Ice Machine. Models FME504, FME804, NME454, NME654

INSTALLATION & OPERATING GUIDE

Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Instruction Manual. Portion Cup Cheese Warmer

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Hot Water Dispensers HWD2, HWD3, HWD5. Table of Contents

STORM. Bottom-Load. Water Dispenser User Manual

Transcription:

Horizon Elite Ice Machine Installation Instructions for Harmony Top-mount Applications HCD/HMD710AHT, HCC1010AHT, HCC1410AHT, HCC1010WHT, HCC1410WHT, HMC1010AHT, HMC1410AHT, HMC1010WHT, HMC1410WHT, HCE1010AHT, HCE1410AHT, HCE1010WHT, HCE1410WHT HME1010AHT, HME1410AHT, HME1010WHT, HME1410WHT (See model number configurator on page 2 for details.) rder parts online www.follettice.com Horizon top-mount ice machines fit most countertop dispensers manufactured by Cornelius Lancer SerVend self-contained 801 Church Lane Easton, PA 18040, USA Toll free (877) 612-5086 +1 (610) 252-7301 www.follettice.com 01113323R02

Chewblet Ice Machine Model Number Configurations HC D 1810 A V S Icemaker MC Maestro Chewblet (425 Series) HC Horizon Chewblet (710, 1010, 1410, 1810, 2110 Series) HM Horizon Micro Chewblet Voltage C 208-230/60/1 (icemaking head) Self-contained only. D 115/60/1 (icemaking head) Self-contained and remote. If remote unit, high side is 208-230/60/1. E 230/50/1 (icemaking head) Self-contained only. F 115/60/1 (icemaking head) Remote only. High side is 208-230/60/3. Series 425 up to 425 lbs (193 kg) 710 up to 675 lbs (306 kg) 1010 up to 1061 lbs (482 kg) 1410 up to 1466 lbs (665 kg) 1810 up to 1790 lbs (812 kg) 2110 up to 2039 lbs (925 kg) Condenser A Air-cooled, self-contained W Water-cooled, self-contained R Air-cooled, remote condensing unit N Air-cooled, no condensing unit for connection to parallel rack system Application V Vision H Harmony B Ice storage bin J Drop-in M Ice Manager diverter valve system P Cornelius Profile PR150 Configuration S RIDE (RIDE remote ice delivery equipment) T Top-mount CAUTIN! This appliance should be connected by a qualified person in accordance with applicable codes. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Connect to potable water supply only. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance. This appliance is intended to be used for household and similar applications such as staff kitchen areas in shops, offices and other working environments; farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type environments; catering and similar non-retail applications. WARNING! To avoid a hazard due to instability of the appliance, it must be fixed in accordance with the instructions. 2 self-contained HARMNY TP-MUNT

Read and complete the following 8 installation steps 1 Unpack 2 Site preparation 3 Bin preparation 4 Louvered docking assembly Ice transport tube 5 6 External connection 7 Internal connection 8 Front cover HARMNY TP-MUNT self-contained 3

Unpack 1 Carefully unpack and inspect the contents of your Follett ice machine. 1.1 Unpack ice machine ➌ ➍ ➎ 7/16" 7/16" D NT TILT ICE MACHINE T ACCESS BLTS! CMPRESSR DAMAGE WILL RESULT ➏ ➐ 4 self-contained HARMNY TP-MUNT

Prepare the installation site. 2 Provide drainage, water supply and electrical power to within 6 feet (2m) of ice machine in accordance with local and national codes. utdoor installation is not recommended and will void warranty. Site preparation 2.1 2.1 Installation site requirements 2 ft. x 1" D silicone tubing Minimum 8" radius H_C1010A/W NEMA 6-15 ➍ 3/4" barb x 3/4" FPT ➌ 3/4" MPT x 1" slip 1" Stand pipe/drain ➌ H_D710A NEMA 5-15 H_E1010A/W requires 15A circuit, 1.50 mm 2 wire H_C1410A/W NEMA 6-20 1/4" (6,4 mm) 1' (0,3 m) ➍ H_E1410A/W requires 20A circuit, 4.00 mm 2 wire Electrical H_C1010/1410(A/W)HT 208-230/60 H_D710AHT 115/60 H_E1010/1410(A/W)HT 230/50 Requires dedicated 15A circuit. (H_E1010A/W requires 15A dedicated circuit 1.50 mm 2 wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm 2 wire) Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination. Potable water supply (3/8 push-in internal connection, 3/8 D tubing required) 10-70 psi (69-483kpa) 45 to 90 F (7 to 32 C) Follett recommends the use of an in-line water filtration system (item# 00130286) This equipment is to be installed with adequate backflow protection to comply with applicable federal, state, and local codes Condenser water supply for water-cooled systems ➌ (1/4 FPT inlet, 1/4 FPT outlet) 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.) 45 to 90 F (7 to 32 C) 1.5 gallons per minute (5.68 liters per minute) Drain ➌ (3/4 Barb) Minimum 8 radius on silicone drain line. Drain line from the ice machine must have at least 1/4 per foot pitch (6,4mm/0,3m). HARMNY TP-MUNT self-contained 5

Dispenser preparation Prepare the dispenser. 3 Note: The instructions below only apply to 22" & 30" wide dispensers. 44" wide dispenser instructions may be found with the top kit. 3.1 Top preparation ALL 3.2 Top preparation ALL ➌ All models Remove protective tape from gaskets Apply gaskets. Install coupling through bottom of dispenser top and secure with locking nut ➌ 3.3 Top preparation ALL 3.4 Top preparation CRNELIUS Screw 4" (102mm) extension into bottom of shuttle actuator Cornelius models only Remove protective tape Apply gasket 6 self-contained HARMNY TP-MUNT

3.5 Top preparation LANCER 3.6 Agitation adjust. CRNELIUS N FF Lancer models only Remove protective tape Apply gaskets Cornelius models ED, DB, DF, IDC and FLAVR FUSIN Adjust the agitation timer located on the Cornelius PC board to 1 second on, 1 hour off. Note: See Cornelius manual for more information. 3.7 Agitation adjustments LANCER 4500 SERIES PRESS IN N THIS SIDE T TURN SWITCH FF. RCKER SWITCHES (VIEW LKING DWN) FF 1 2 3 4 5 6 7 8 PRESS IN N THIS SIDE T TURN SWITCH N. SWITCH NUMBER 3 4 AGITATIN TIME 1 SECND 2 SECNDS 3 SECNDS 4 SECNDS = N = FF SWITCH FF SIDE VIEW SWITCH N SWITCH NUMBER 5 6 7 8 N AGITATIN 10 MINUTES 20 MINUTES 30 MINUTES 40 MINUTES 50 MINUTES 60 MINUTES 70 MINUTES 80 MINUTES 90 MINUTES 100 MINUTES 110 MINUTES 120 MINUTES 130 MINUTES 140 MINUTES AGITATIN FREQUENCY 150 MINUTES SIDE VIEW Lancer 4500 series only Adjust the agitation time to 1 second, and the agitation frequency to 150 minutes. See Lancer manual for more information. 3.8 Agitation adjustments LANCER Sensation and Touchpoint No agitation adjustment required HARMNY TP-MUNT self-contained 7

3.9 Agitation adjustments LANCER FS SERIES Initialization Screen (Boot Up nly) Main Menu Major/Minor Config Bonus Key Soda/Plain Water Config Dispense nly PC Mode PC Time Ice Stir ff Ice Stir n Sold ut Carb Sensors Ice Bin Sensors Valve Code Version Number f Valves Lancer FS-16 Ver. 0.200 Sub-Catagory Brands Per Side V:1 L:2 R:1 Bonus Key Setup V:1 T:F M:S B:W Soda/Plain Water V:2 1:S 2:W 3:S 4:W Dispense Delay V:1 B1 DLY1 Set PC Mode Menu ff n n Time (MSEC) 05000 FF Time (MIN) 00150 n Time (MSEC) 01000 Selection Sold ut Sold ut #1 Upper Lower 1000 500 Ice Bin ptic 12 0.104 0.104 34 0.104 0.104 1 2 3 4 n n n n Reload Defaults? Reset Defaults No Yes 1000 Cancel 2nd Sub-Catagory Sold ut #1 ff Sold ut #1 V:1 B:1 Enter Scrolls through Main Menu Press "Enter" to enter sub-catagory Moves curser to right or left Changes value (number/letter) Press "Enter" to enter save changes Press "Cancel" to exit menu Lancer FS series only Hold down cancel and left button to get to hidden menu Type in code 6655 Type in 150 minutes of off time and 1010 milliseconds (1 second of time) as the preferred setting Note: See Lancer manual for more information 3.10 Agitation adjustments SERVEND SerVend models only No agitation adjustment required. 8 self-contained HARMNY TP-MUNT

3.11 Dispenser diverter plate overview (Installation on next page) Single Agitator P/N 307277 Diverter plate (single agitator Cornelius dispensers and left-hand dispense chute on dual-agitator Cornelius dispensers) Dual Agitator P/N 307277 Diverter plate (single agitator Cornelius dispensers and left-hand dispense chute on dual-agitator Cornelius dispensers) P/N 00996207 Diverter plate (right-hand dispense chute on dual-agitator dispensers) HARMNY TP-MUNT self-contained 9

3.12 Dispenser diverter plate installation CRNELIUS ED, DF and DB SERIES GATE MUNTING PLATE STRAGE HPPER FLANGE ETENDS INT STRAGE HPPER THRUGH GATE PENING ICE DIVERTER ICE CHUTE CVER APPLY RTV T THIS SURFACE T SEAL T HPPER GATE MUNTING PLATE 10-32 WASHER GASKET ICE CHUTE Cornelius ED, DF and DB series only These dispensers require the installation of an ice diverter at the dispenser opening. Disassemble chute assembly Discard factory restrictor plate Replace with alternate diverter plate (supplied) 3.13 Agitation adjustments Cornelius IDC and Flavor Fusion These dispensers require modifications for compatibility with Chewblet ice. Agitation times must be set to 1 second N, 1 hour FF and the ice restrictor plate must be adjusted to the fully open position. See your beverage supplier for these modifications. 10 self-contained HARMNY TP-MUNT

Install the louvered docking assembly. Louvered docking assembly 4 BEFRE PRCEEDING Prior to installing the louvered docking assembly, ensure that the drain fitting is oriented (right or left) correctly for your installation. An optional straight drain fitting is also supplied. You may need to remove the back panel of the docking assembly in order to re-orient or change the drain fitting. Replace back panel prior to mounting the docking assembly. 4.1 Louvered docking assembly Mount louvered docking assembly HARMNY TP-MUNT self-contained 11

Ice transport tube Install the ice transport tube. 5 5.1 Ice transport tube installation Hot Water 160 F (71 C) ➌ Install supplied ice transport tube insulation Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers before making connection to ease assembly Connect ice transport tube to coupling on louvered docking station Connect ice transport tube to shuttle actuator ➌ 12 self-contained HARMNY TP-MUNT

External connections Connect utilities to louvered docking assembly. 6 6.1 Air-cooled ice machines only 6.2 Water-cooled ice machines only ➌ ➏ ➐ ➌ ➏ 2 ft. x 1" D silicone tubing Minimum 8" radius ➑ 2 ft. x 1" D silicone tubing Minimum 8" radius 3/4" barb x 3/4" FPT ➍ 3/4" MPT x 1" slip ➎ 1" Stand pipe/drain Rough-in ice machine potable water supply. 3/8 push-in connection will be made at shut-off valve inside machine Remove access panel if necessary. Connect the silicone tubing to the ice machine 3/4 drain barb ➌. Assemble the 3/4 barb x 3/4 FPT to the 3/4 MPT x 1 slip. Connect the other end of the silicone tubing to the 3/4 barb ➍. Connect the 1 slip fitting to the 1 stand pipe/drain ➎. Note: Minimum 8 radius on silicone drain line. Drain line from the ice machine must have at least 1/4 per foot pitch (6,4mm/0,3m). Apply Petrol-gel to barbed drain fitting ➏ Replace access panel. ➎ 3/4" barb x 3/4" FPT ➍ 3/4" MPT x 1" slip 1" Stand pipe/drain Rough-in ice machine potable water supply. 3/8 push-in connection will be made at shut-off valve inside machine Remove access panel if necessary. Connect the silicone tubing to the ice machine 3/4 drain barb ➌. Assemble the 3/4 barb x 3/4 FPT to the 3/4 MPT x 1 slip. Connect the other end of the silicone tubing to the 3/4 barb ➍. Connect the 1 slip fitting to the 1 stand pipe/drain ➎. Note: Minimum 8 radius on silicone drain line. Drain line from the ice machine must have at least 1/4 per foot pitch (6,4mm/0,3m). Connect cooling water supply ➏ and return ➐ Apply Petrol-gel to barbed drain fitting ➑ Replace access panel. HARMNY TP-MUNT self-contained 13

Connect louvered docking assembly to ice machine. CAUTIN Plug must be accessible after final installation. H_E1410A/W 230/50/1 requires a 20A circuit (4.00 mm 2 wire) Air-cooled ice machines follow steps 7.1 through 7.5. Internal connections 7 7.1 Ice transport tube 7.2 Potable water and drain lines Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain fitting Insert ice transport tube all the way into coupling and tighten nut firmly Insert potable water line into valve 7.3 Power cord 7.4 Power cord Remove twist tie Carefully pass cord thru opening and plug into wall outlet For H_E units, install a suitable plug Position plate into opening and secure with supplied screw 14 self-contained HARMNY TP-MUNT

Water-cooled ice machines follow steps 7.6 through 7.12. 7.5 TDS switch 7.6 Cooling lines CLEANER FULL DRAIN CLG HIGH PRES HIGH AMPS SERVICE MAINT/CLEAN LW WATER TIME DELAY SLEEP CYCLE MAKING ICE LW BIN PWER N TDS HIGH LW CLEAN In ut Set the TDS switch on the electrical box: HIGH: for extended service life LW: for low-scale water Install ice machine cooling water lines to louvered docking assembly 7.7 Ice transport tube 7.8 Potable water and drain lines Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain fitting Insert ice transport tube into coupling and tighten nut firmly Insert potable water line into valve HARMNY TP-MUNT self-contained 15

7.9 Cooling lines and power 7.10 Power cord Connect cooling water lines to ice machine (Water "ut" connects to water regulator.) Water valve is set at the factory. D NT remove seal or adjust water valve Remove twist tie Carefully pass cord thru opening and plug into wall outlet For HCE/HME units, install a suitable plug 7.11 Power cord 7.12 TDS switch CLEANER FULL DRAIN CLG HIGH PRES HIGH AMPS SERVICE MAINT/CLEAN LW WATER TIME DELAY SLEEP CYCLE MAKING ICE LW BIN PWER N TDS HIGH CLEAN LW Position plate into opening and secure with supplied screw Set the TDS switch on the electrical box: HIGH: for extended service life LW: for low-scale water 16 self-contained HARMNY TP-MUNT

Front cover Install front cover to ice machine. 8 8.1 Install front cover ➌ Slide ice machine cover over machine ensuring that tabs on back of cover slip under louvers on back of louvered docking assembly Insert and tighten two screws through cover and into louvered docking assembly For air-cooled machines only, install plastic grill ➌ NTICE Ice machine MUST be sanitized prior to operation! Consult peration and Service Manual provided with ice machine for sanitizing instructions. HARMNY TP-MUNT self-contained 17

Long tube run recommendations max. 2 ft (0,6m) 1/4" (6,4mm) 1' (0,3m) Pitch ice transport tube to allow melt water to drain towards ice machine Secure insulated ice transport tube at least every 2 ft (0,6m) to prevent dips or traps 18 self-contained HARMNY TP-MUNT

HARMNY TP-MUNT self-contained 19

Horizon, Horizon Elite, Maestro, Harmony, Ice Manager, SafeCLEAN, Sani-Sponge and Vision are trademarks of Follett LLC. Chewblet, RIDE and Follett are registered trademarks of Follett LLC, registered in the US. 801 Church Lane Easton, PA 18040, USA Toll free (877) 612-5086 +1 (610) 252-7301 www.follettice.com 01113323R02 Follett LLC 4/18